Gsweep_SN_vs_Freq.py
233 lines (188 loc) · 6.44 KB
/
Gsweep_SN_vs_Freq.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
'''
Generic Sweep script
(currently setup for no more than 3 dims)
20/10/2015
- B
'''
# import numpy as np
from time import time, sleep
from parsers import copy_file
from ramp_mod import ramp
from DataStorer import DataStoreSP # , DataStore2Vec, DataStore11Vec
# Drivers
from dummydriver import instrument as dummy
from keithley2000 import instrument as key2000
from AnritzuSig import instrument as AnSigGen
from SRsim import instrument as sim900c
from Sim928 import instrument as sim928c
# from Yoko import instrument as yoko
from AfDigi import instrument as AfDig # Digitizer driver
import gc # Garbage memory collection
from IQcorr import Process as CorrProc # Handle Correlation measurements
# import sys
import os
from AfSgen import instrument as Afsgen_inst
# import logging
thisfile = __file__
filen_0 = '3040_SN1'
folder = 'data_Dec09\\'
if not os.path.exists(folder):
os.makedirs(folder)
sim900 = sim900c('GPIB0::12::INSTR')
vm = key2000('GPIB0::29::INSTR')
# Digitizer setup
lags = 200
BW = 5e5
lsamples = 1e6
corrAvg = 1
f1 = 5.2e9
f2 = 4.6e9
fd = 9.8e9
# Using a bandpass filter in front of both digitizers (3.9-6GHz)
D1 = AfDig(adressDigi='PXI7::13::INSTR', adressLo='PXI7::14::INSTR', LoPosAB=1, LoRef=3,
name='D1 Lags (sec)', cfreq=f1, inputlvl=-10,
start=(-lags / BW), stop=(lags / BW), pt=(lags * 2 + 1),
nSample=lsamples, sampFreq=BW)
D2 = AfDig(adressDigi='PXI8::14::INSTR', adressLo='PXI8::15::INSTR', LoPosAB=0, LoRef=0,
name='D2 Lags (sec)', cfreq=f2, inputlvl=-10,
start=(-lags / BW), stop=(lags / BW), pt=(lags * 2 + 1),
nSample=lsamples, sampFreq=BW)
sgen = Afsgen_inst(adressSig='PXI8::9::INSTR', adressLo='PXI8::10::INSTR',
LoRef=2, name='Signal Gen', start=2e9, stop=6e9, pt=1,
sstep=1e9, stime=0.0)
sgen.set_power(-30)
sgen.output(0)
pFlux = AnSigGen('GPIB0::17::INSTR', name='FluxPump',
start=0.03, stop=0.03, pt=1,
sstep=30e-3, stime=1e-3)
pFlux.set_power_mode(0) # Log(0)/Linear mode in mV (1)
pFlux.set_frequency(fd)
pFlux.sweep_par = 'power' # Power sweep
pFlux.set_power(-50)
pFlux.output(0) # Power OFF (0)/ On (1)
# -20 dB at output
dummyD1D2 = dummy('prober', name='Probe frequency', start=4.5e9, stop=5.8e9, pt=391, sstep=6e9, stime=0.0)
dummyD1D2.D1 = D1
dummyD1D2.D2 = D2
dummyD1D2.sgen = pFlux
dummyD1D2.sweep_par = 'f11'
vBias = sim928c(sim900, name='V 1Mohm', sloti=4,
start=-20.0+0.0017, stop=20.0017, pt=9,
sstep=0.200, stime=0.025)
vBias.set_volt(0.0)
vBias.output(1)
vMag = sim928c(sim900, name='Magnet V R=22.19KOhm', sloti=3,
start=-2.6, stop=-2.6, pt=1,
sstep=0.03, stime=0.020)
vMag.set_volt(0.0)
vMag.output(1)
nothing = dummy('none', name='nothing',
start=0, stop=1, pt=1,
sstep=20e-3, stime=0.0)
DC_check = True
dim_1 = vBias
dim_1.defval = 0.0
dim_2 = dummyD1D2
dim_2.defval = 4e9
dim_3 = vMag
dim_3.defval = 0.0
dim_1.UD = False
recordD12 = True # activates /deactivates all D1 D2 data storage
D12 = CorrProc(D1, D2, pFlux, sgen, lags, BW, lsamples, corrAvg)
D12.doHist2d = False
D12.doBG = False
D12.doRaw = False
D12.doCorrel = True
def sweep_dim_1(obj, value):
ramp(obj, obj.sweep_par, value, obj.sstep, obj.stime)
sleep(0.1)
def sweep_dim_2(obj, value):
ramp(obj, obj.sweep_par, value, obj.sstep, obj.stime)
def sweep_dim_3(obj, value):
ramp(obj, obj.sweep_par, value, obj.sstep, obj.stime)
DS = DataStoreSP(folder, filen_0, dim_1, dim_2, dim_3, 'Vx1k')
DS.ask_overwrite()
copy_file(thisfile, filen_0, folder)
if recordD12:
D12.create_datastore_objs(folder, filen_0, dim_1, dim_2, dim_3)
# CorrProc controls, coordinates D1 and D2 together (also does thes calcs.)
def record_data(kk, jj, ii, back):
'''This function is called with each change in ii,jj,kk
content: what to measure each time
'''
if recordD12:
D12.init_trigger() # Trigger and check D1 & D2
vdata = vm.get_val() # acquire voltage data point
if back is True:
return DS.record_data2(vdata, kk, jj, ii)
DS.record_data(vdata, kk, jj, ii)
if recordD12:
D12.full_aqc(kk, jj, ii) # Records and calc D1 & D2
# if (lsamples/BW > 30):
# save data at each point if it takes longer than 1min per point
# save_recorded()
def save_recorded():
'''
Which functions to call to save the recorded data
'''
DS.save_data() # save Volt data
if recordD12:
D12.data_save() # save Digitizer data
# go to default value and activate output
sweep_dim_1(dim_1, dim_1.defval)
sweep_dim_2(dim_2, dim_2.defval)
sweep_dim_3(dim_3, dim_3.defval)
dim_1.output(1)
dim_2.output(1)
dim_3.output(1)
print 'Executing sweep'
texp = (2.0*dim_3.pt*dim_2.pt*dim_1.pt*(0.032+corrAvg*lsamples/BW)/60.0)
print 'req time (min):' + str(texp)
t0 = time()
try:
for kk in range(dim_3.pt):
sweep_dim_3(dim_3, dim_3.lin[kk])
for jj in range(dim_2.pt):
sweep_dim_2(dim_2, dim_2.lin[jj])
# sweep_dim_1(dim_1, dim_1.start)
sleep(0.2)
print 'Up Trace'
for ii in range(dim_1.pt):
sweep_dim_1(dim_1, dim_1.lin[ii])
record_data(kk, jj, ii, False)
if dim_1.UD is True:
sweep_dim_1(dim_1, dim_1.stop)
sleep(0.1)
print 'Down Trace'
for ii in range((dim_1.pt - 1), -1, -1):
sweep_dim_1(dim_1, dim_1.lin[ii])
record_data(kk, jj, ii, True)
sweep_dim_1(dim_1, dim_1.start)
if DC_check is True:
vBias.get_volt(True) # Introduce some system self checkup
vMag.get_volt(True)
save_recorded()
t1 = time()
t_rem = ((t1 - t0) / (jj + 1) * dim_2.pt * dim_3.pt - (t1 - t0))
print 'req time (h):' + str(t_rem / 3600)
gc.collect()
print 'Measurement Finished'
finally:
print 'Time used min:' + str((time() - t0) / 60)
print 'Sweep back to default'
sweep_dim_1(dim_1, dim_1.defval)
sleep(1)
sweep_dim_2(dim_2, dim_2.defval)
sleep(1)
sweep_dim_3(dim_3, dim_3.defval)
sleep(1)
dim_1.output(0)
sleep(1)
dim_2.output(0)
sleep(1)
dim_3.output(0)
sim900._dconn()
gc.collect()
D1.performClose()
D2.performClose()
print 'done'