ABOUT THIS PACKAGE

This package was created for the purpose of automating the tasks of finding yields for Magnesium isotopes between Mg 32 - Mg 40 with LISE++. It is meant to be ran after installing LISE++ on your computer. The target audience is meant to be members of the lifetime grout at NCSL/FRIB.

However, anyone interested is also allowed to run this package.

If you do not have LISE++ installed on your computer, you can go to the following link to install LISE++

For general information about LISE++, go to the following website

Follow the instructions that come with the installation of LISE++ to utilize this package. After LISE++ has been installed, make sure to have a shortcut (the logo) on your desktop as this package utilizes on finding the icon on your desktop. When running the package, make sure the LISE++ icon is visible on your desktop. That is the way it is currently set up, future updates will work on ridding the dependence on the icon to run the script.

Future updates will include the ability to use any isotope on the nuclear chart that LISE++ offers and update to the FRIB configuration as the Coupled Cyclotron Facility (CCF) was shutdow November 15th, 2020.

A link to a video presentation can be found at:

INFORMATION ABOUT RUNNING SCRIPT:

  • Currently, only tested on Windows OS.

The automation scripts were written in python 3. If you do not have python 3 installed, you will need to install it as certain functions are only available in python 3. A quick gooogle search on how to install python 3 for Windows will provide the information you need.

To check if you have python installed, go to your windows terminal and type:

python

This should open python. If an error is invoked, you will need to install python 3.

The following modules are required to run:

  • pyautogui
  • pyperclip
  • pandas
  • os
  • platform
  • time
  • numpy
  • argparse

If they are not installed, they can be installed via the following command in your windows terminal:

pip install (example: pip install pyautogui)

If that does not work, try the following:

py -m pip install

If you do not have pip installed, proceed to the following link to donwload pip:

There are two files that are responsible for all of tasks regarding LISE++

  • implementation_file.py
    • Implementation file containing all of functions that are called by main_start.py
  • main_start.py
    • The function to be called in the top-most directory on terminal to begin the process. The command to run the script is as follows:

      python -m nuclear_gamma_tracker.auto_4_lise.py -FLAG <isotope_start> <isotope_end> <wedge_start> <wedge_end> <FP_width> -v

        - '-FLAG'	   : Flag that tells the script if LISE++ is open or not. These have to be specified. You have two options:
        					`-f` : It is the first time you are opening LISE++
        					`-nf`: Not the first time you are opening LISE++ 
        - Isotope start : Which Magnesium isotope you want to start with 
        - Isotope end   : Which Magnesium isotope you want to end with
        - Wedge start   : The starting wedge thickness at the I2 plane
        - Wedge end     : The terminating wedge thickness at the I2 plane
        - FP width      : The slit width of the focal plane slits at (used to control momentum acceptance of beam)
        - '-v'		: An optional argument that improves verbose output when command is run on terminal (as a double check) 
      
    • To view more information as to what the parser requires when calling main_start.py witht the command above, run the following from the top most directory:

      • python -m nuclear_gamma_tracker.main_start.py -h

To run with a conda environment

To create conda environment with requirements file that is provided:

  • conda env create --prefix ./envs --file environment.yml
  • conda activate

To get out of the environment once you are done:

  • conda deactivate

To remove the environment from your machine (if you wish to do so):

  • conda remove --name NAME_OF_ENVIRONMENT --all

DATA STORAGE

  • The data is saved in individual .csv files for each corresponding Magnesium isotope in the same folder the scripts are in. It is then required from that the user visually inspects the .csv files to find best compromise between intensity and purity.

  • The intermediate files "data.txt" and "pps_data.txt" are files that are created with the sole purpose of being reused. They are created when the script is originally executed and keeps being updated corresponding to each isotope. It is safe to delete these two files once you are done with the analysis.

GENERAL INFORMATION

  • It is recommended to set all NSCL and FRIB files to have a momentum acceptance of 1% (dp/p = 1%) at the I2_Slits and the pre-separator focal plane (I4_PS_FP), respectively.

  • To allow for largest intenisty possible on the FRIB/LISE++ configuration, the pre-separator slits (PS_Wedge_Slits) are set to the aperture limit, 135 mm. Wedges and momentum acceptances were later adjusted downstream to yield optimal purity results without large comprimise to intensity.

  • FRIB intensities should be 2-3 orders of magnitude greater than NSCL intensities, roughly speaking.