Skip to content

dews/exoedge-modbus

Repository files navigation

Description

image

This project is a Modbus source for Exosite's ExoSense which uses ExoEdge.

Install

From Source

pip install -r requirements.txt
python setup.py install

From PyPi

The wheel for this hasn't been published yet.

pip install exoedge_modbus

ExoEdge Configuration

In order to start using this Modbus source, start the edged daemon with your desired parameters. For more information on edged, visit ExoEdge on PyPi.

Example

$ cat modbus-test1.ini
[device]
murano_host = mqtt://f5330e5s8cho0000.m2.exosite.io/
murano_id = modbus-test1
$ edged -i modbus-test1.ini go

ExoSense Configuration

Below is an example config_io settings that illustrates how Modbus RTU data can be sent to ExoSense via ExoEdge.

{
  "channels": {
    "001": {
      "display_name": "Input Register 1",
      "description": "Input Register 1.",
      "channel_name": "001",
      "properties": {
        "data_unit": "NUMBER",
        "data_type": "TEMPERATURE",
        "min": null,
        "max": null,
        "precision": null,
        "device_diagnostic": false
      },
      "protocol_config": {
        "timeout": null,
        "report_on_change": false,
        "report_rate": 2000,
        "application": "Modbus_RTU",
        "app_specific_config": {
          "byte_endianness": "big",
          "register_range": "INPUT_REGISTER",
          "register_offset": "0002",
          "register_count": 1,
          "register_endianness": "big",
          "bitmask": "0xffffffff",
          "slave_id": 1,
          "evaluation_mode": "unsigned"
        },
        "sample_rate": 2000,
        "input_raw": {},
        "offset": 0,
        "interface": "/dev/ttyM0",
        "down_sample": "ACT"
      }
    }
  }
}

Below is the config_applications configuration needed for the config_io above:

{
  "applications": {
    "Modbus_RTU": {
      "application_display_name": "Modbus RTU",
      "interfaces": [
          {
            "interface": "/dev/ttyM0",
            "baud_rate": 19200,
            "stop_bits": 1,
            "data_bits": 7,
            "parity": "none"
          }
      ]
    }
  }
}

Below is a config_io example for Modbus_TCP:

{
  "channels": {
    "1": {
      "display_name": "Input Register 1",
      "description": "One-second intervals of input register 1.",
      "properties": {
        "max": null,
        "precision": null,
        "data_type": "BINARY",
        "min": null
      },
      "protocol_config": {
        "application": "Modbus_TCP",
        "report_on_change": false,
        "report_rate": 1000,
        "sample_rate": 1000,
        "down_sample": "ACT",
        "app_specific_config": {
          "ip_address": "192.168.11.139",
          "port": 5020,
          "register_range": "INPUT_REGISTER",
          "register_offset": 0,
          "register_count": 1,
          "byte_endianness": "big",
          "register_endianness": "big",
          "evaluation_mode": "string-ascii",
          "bitmask": "0x0000"
        }
      }
    }
  }
}

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages