Notifications
You must be signed in to change notification settings - Fork 1
/
Digilinus.py
executable file
·169 lines (146 loc) · 4.55 KB
/
Digilinus.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
#!/usr/bin/python
# -*- coding: utf-8 -*-
# Sensors used
# 28.571AB8010000 ute-stugan
# 28.7EF3FE000000 inne-stugan
#
# Creation: 02.01.2013
# Last Update: 07.04.2015
#
# Copyright (c) 2013-2015 by Georg Kainzbauer <http://www.gtkdb.de>
#
# This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation; either version 2 of the License, or
# (at your option) any later version.
#
# import sys module
# CREATE table digitemp (
# dtKey int(11) NOT NULL auto_increment,
# time timestamp NOT NULL,
# temp1 decimal(3,1) NOT NULL,
# temp2 decimal(3,1) NOT NULL,
# PRIMARY KEY (dtKey),
# KEY time_key (time)
# );
#
# GRANT SELECT,INSERT ON digitemp.* TO digitemp@localhost
# IDENTIFIED BY 'password';
import sys
import string, os
import MySQLdb
timefmt = '%Y-%m-%d %H:%M:%S'
import time
import re
from byteport.clients import ByteportHttpClient
import socket
import fcntl
import struct
# Byteport setup
NAMESPACE = "GoldenSpace"
API_KEY = "b43cb5709b37ff3125195b54"
uid = "Digilinus" # Set default value
# System setup
DEBUG_ON = 'NO' # For debugging, print temperature, sensors etc
POLL_INTERVAL = 30 # Normally 30 Minutes, to be adjusted!
# Mysql setup
DB_HOST = 'localhost'
DB_NAME = 'Digitemp'
DB_USER = 'Digitemp'
DB_PASSWD = 'Digitemp'
#DB_TABLE = 'Digitemp'
DB_TABLE = 'DigiTable'
DB_PORT = 3333 # Not used now
# Connect to the database
try:
cxn=MySQLdb.connect(host=DB_HOST,user=DB_USER,passwd=DB_PASSWD, db="Digitemp")
# cxn=MySQLdb.connect(host=DB_HOST,user=DB_USER,passwd=DB_PASSWD, db="Digitemp", port=int(DB_PORT))
cursor=cxn.cursor()
print "Database connected"
except cxn.Error, e:
print "Problem connecting to database"
sys.exit(-1)
try:
cursor.execute("CREATE TABLE IF NOT EXISTS DigiTable(dtKey INT PRIMARY KEY NOT NULL AUTO_INCREMENT,\
DTimeStamp timestamp NOT NULL,\
OutTemp float(3,1) NOT NULL,\
InTemp float(3,1) NOT NULL)")
# ENGINE=InnoDB)")
print "Table defined: ", DB_TABLE
except cxn.Error, err:
print("Failed creating table: {}".format(err))
sys.exit(-1)
# SensorList [SensorName, FileName, Temperature value (set default)]
SensorList = ['OutTemp', '/mnt/1wire/28.571AB8010000/temperature', -99,
'InTemp', '/mnt/1wire/28.7EF3FE000000/temperature', -99]
print(" -----------------------------------------------------")
print(" %s " % ("Defined sensors"))
print(" %-8s %s" % ( SensorList[0], SensorList[1]))
print(" %-8s %s" % ( SensorList[3], SensorList[4]))
print(" -----------------------------------------------------")
print
client = ByteportHttpClient(NAMESPACE, API_KEY, uid, initial_heartbeat=False)
# print header for results table
print(" Date | Sensor | Temperature")
print(" -----------------------------------------------------")
OutTemp = -99
InTemp = -99
#while True:
now = time.strftime("%c") #Read time for sensor reading
# Setup filenames etc.
OutSensor = SensorList[0]
OutFileName = SensorList[1]
InSensor = SensorList[3]
InFileName = SensorList[4]
# Read Outdoor sensor
OutTemp = -99
try:
MyFile = open(OutFileName)
except:
print ("Unable to open file: ", OutFileName)
try:
OutTemp = float(MyFile.readline())
MyFile.close()
except:
MyFile.close()
# Read Indoor sensor
InTemp = -99
try:
MyFile = open(InFileName)
except:
print ("Unable to open file: ", InFileName)
try:
InTemp = float(MyFile.readline())
MyFile.close()
except:
MyFile.close()
# Print all temperature values, debug purpose...
#print("Pre- %s %s %+4.2f" % (now, "OutTemp", OutTemp))
#print("Pre- %s %s %+4.2f" % (now, "InTemp", InTemp))
if OutTemp != -99:
# print(" %s %s %+4.1f" % (now, "OutTemp", OutTemp))
try:
client.store({"OutTemp": OutTemp}) # Store value in Byteport
except:
print("Failed storing in Byteport:")
else:
print("No reading %s %s %+4.1f" % (now, "OutTemp", OutTemp))
if InTemp != -99:
# print(" %s %s %+4.1f" % (now, "InTemp ", InTemp))
try:
client.store({"InTemp": InTemp}) # Store value in Byteport
except:
print("Failed storing in Byteport:")
else:
print("No reading %s %s %+4.1f" % (now, "InTemp ", InTemp))
# Add the reading to the database
try:
sql = "INSERT INTO DigiTable (InTemp, OutTemp) VALUES (%+3.1f, %+3.1f)"
cursor.execute( sql % (InTemp, OutTemp))
cxn.commit()
except cxn.Error, err:
print("Failed storing in Mysql table: {}".format(err))
# Set poll interval, number of seconds
# time.sleep(POLL_INTERVAL*60)
# quit python script
sys.exit(0)