Notifications
You must be signed in to change notification settings - Fork 0
/
io_thread.py
160 lines (125 loc) · 4.32 KB
/
io_thread.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
from directnet import KSNetClient
from traceback import print_exc
from queue import Queue
from threading import Thread
from power_link import PowerLink
from datetime import datetime
import time
class IOThread(Thread):
queue = Queue()
TEMPERATURES = (
'V2162', # za TC
'V2166', # do topeni
'V2172', # v akumulacce
'V2156', # venku
'V2216', # tlak vody
)
VARIABLES = (
'V1773', # pozadovana teplota
'V1776', # maximalni teplota
'V2244', # offset teploty add
'V2245', # offset teploty sub
)
BITS = (
'C30', # TC
'C31', # Podlahy
'C32', # Topeni
'C24', # do podlah
'C26', # do akumulacky
'C25', # z akumulacky
'C40', # plna automatika
'C41', # automatika topi do nadrze
'S14', # temperovani
'C15', # HDO
'C33', # Nautila
)
def __init__(self, datasource=None, **kwargs):
"""
:type datasource: DataSource
"""
super().__init__(**kwargs)
self.datasource = datasource
self.stopped = False
self.stopping = False
self.directnet = None
self.powerlink = None
self.last_sync = datetime.now()
def run(self):
while not self.stopped:
function, kwargs = self.queue.get()
try:
function(**kwargs)
except Exception:
print_exc()
self.queue.task_done()
def connect(self):
self.directnet = KSNetClient('10.0.0.209', 28784)
def connect_power(self):
self.powerlink = PowerLink()
def make_stop(self):
self.stopped = True
def stop(self):
self.queue.put([self.make_stop, {}])
self.queue.join()
self.stopping = True
self.join()
def add(self, method, **kwargs):
if not self.stopping:
self.queue.put([method, kwargs])
def on_timer(self):
if self.stopping:
return
timeout = (datetime.now() - self.last_sync).total_seconds()
print("Cycle duration", timeout)
if timeout < 10:
print("Sleeping", 10 - timeout)
time.sleep(10 - timeout)
print("Timer ticking ...")
self.last_sync = datetime.now()
self.add(self.read_temperatures)
self.add(self.read_bits)
self.add(self.measured)
self.add(self.on_timer)
def read_temperatures(self):
print("Reading temperatures")
temperatures = self.datasource.temperatures
variables = self.datasource.variables
if self.directnet:
for index, address in enumerate(self.TEMPERATURES):
temperatures[index] = self.directnet.read_int(address)
for index, address in enumerate(self.VARIABLES):
variables[index] = self.directnet.read_int(address)
print("Reading power")
if self.powerlink:
power = self.read_power()
temperatures[len(self.TEMPERATURES):] = power
print("Read temperatures", self.datasource.temperatures)
self.datasource.temperatures = temperatures
self.datasource.variables = variables
self.datasource.temperatures_changed.emit()
self.datasource.variables_changed.emit()
def read_bits(self):
print("Reading bits")
bits = self.datasource.bits
if self.directnet:
for index, address in enumerate(self.BITS):
bits[index] = self.directnet.read_bit(address)
print("Read bits", self.datasource.bits)
self.datasource.bits = bits
self.datasource.bits_changed.emit()
def read_power(self):
data = self.powerlink.read()
try:
total = data['1.8.0']
actual = data['31.7']*data['32.7']*data['33.7'] + data['51.7']*data['52.7']*data['53.7'] + data['71.7']*data['72.7']*data['73.7']
except Exception as e:
print('Error calculating power', e, data)
# raise e
return [0, 0]
return [actual, total]
def measured(self):
self.datasource.measured.emit()
def write_bit(self, index, value):
self.directnet.write_bit(self.BITS[index], value)
def write_variable(self, index, value):
self.directnet.write_int(self.VARIABLES[index], value)