Skip to content

naupaka/storcli-check

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

27 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

storcli-check

storcli_check.py is a Python 2.4-compatible script that will check your MegaRAID adapter for issues and send a report by email. It's designed to be self contained and easily added to a cron job. The only file you need from this repo is src/storcli_check.py.

Usage

The following command-line parameters are optional:

  • --mailto: Comma-separated list of emails to send the report to (e.g. "first1.last1@example.com,first2.other2@example.com")
  • --mailserver: The hostname of the SMTP server to use (e.g. "mailhost.example.com")
  • --force: Force the script to send the report even if everything's fine (useful for weekly status)
  • --mailfrom: The user the email will seem to come from. The default is <username>@<hostname>.
  • --mailcc: Comma-separated list of emails to CC the report to (e.g. "first1.last1@example.com,first2.other2@example.com")

NOTE: If --mailto and --mailserver are ommited, the HTML report will be printed on stdout according to the use of --force.

General Information

The script is a relatively simple parser and reporter for the storcli /cx show all command. It checks to ensure that the controller's status is "optimal", all virtual drives are "optimal", and all physical drives are "online", "unconfigured good", "dedicated hot spare", or "global hot spare".

The Report

The report that is emailed contains some controller information, the list of VDs, and the list of PDs. Any errors found during parsing are also reported. You will also find a zip file the contains the output from show all, show events, and also the MegaSAS.log file that storcli generates (one info and event file for each controller).

Real World

I'm using this script to check the state of my LSI controller on a XenServer hypervisor. It was a lot easier than trying to figure out how to pass the controller to a guest VM and using MegaRAID Storage Manager, get MSM snmp installed and running on the hypervisor, etc. The requirements for this script are pretty minimal (in my opinion), and it is working in my lab.

I have it periodically running via cron. It's working so far! I run the defaults every 10 minutes (doesn't send logs if everything's ok), and --force the report once per week:

*/10 * * *  *   root /usr/local/bin/storcli-check --to=me@example.com --mailserver=mailhost.example.com 2>/dev/null
0  8  *  *  mon root /usr/local/bin/storcli-check --to=me@example.com --mailserver=mailhost.example.com --force 2>/dev/null

Caveats

  • SMTP authentication: the SMTP mail server we are running does not require authentication if the FROM and TO domains are local. Therefore, I didn't add authentication to sendmail().
  • Any offline drive will be an error: In my particular case, all of my PDs are part of a volume. If that's not the case in your configuration, you may want to modify which PD states are OK in your configuration.
  • The script was tested with storcli64 version 1.15.05. Other versions will most likely work, but may cause issues with the regular expressions.

Configuration

If you find that the defaults don't work for you, you should be able to make modifications in the Configuration section of the source. I don't use any type of config file. The section is near the top of the script.

Events

An attempt is made to report possible event problems. The following command is run for each controller:

/cx show events filter=warning,critical,fatal

If this command returns anything, the script will consider the controller to be in an error state. The script never clears the events. This means that you may get spammed depending on how often you: a) run the script; b) how quickly you address the issue; c) how soon you clear the events.

Here's an example of a sequence of events that will be reported by this script:

seqNum: 0x0000cf1a
Time: Tue Jun  2 18:02:08 2015

Code: 0x000000fb
Class: 2
Locale: 0x01
Event Description: VD 00/0 is now DEGRADED
Event Data:
===========
Target Id: 0


seqNum: 0x0000cf1d
Time: Tue Jun  2 18:03:11 2015

Code: 0x000000fc
Class: 3
Locale: 0x01
Event Description: VD 00/0 is now OFFLINE
Event Data:
===========
Target Id: 0


seqNum: 0x0000cf20
Time: Tue Jun  2 18:03:35 2015

Code: 0x000000fb
Class: 2
Locale: 0x01
Event Description: VD 00/0 is now DEGRADED
Event Data:
===========
Target Id: 0

In this mock-scenario, we had two drives go offline, which brought the VD offline. We then replaced one of the drives, which moved the VD back into the DEGRADED state. Then we replaced the second drive, which moved the VD back into the OPTIMAL state. Notice, however, the OPTIMAL event was not captured. It doesn't show up since that event is not warning or above.

It's not a perfect system, but it serves its purpose. You'll need to clear the event log of the offending controller to get the report to stop spamming your email.