Пример #1
0
 def calibrate(self):
     self.logSomething('Kalibracja!')
     self.dialog = CalibrateDialogController()
     self.dialog.calibrateGetValue.clicked.connect(self.dialogGetValueClicked)
     self.dialog.calibrateInsertValue.clicked.connect(self.dialogInsertValueClicked)
     self.dialog.calibrate.clicked.connect(self.dialogCalibrateClicked)
     self.dialog.show()
Пример #2
0
class MainWindowController(QtWidgets.QMainWindow, Ui_MainWindow, metaclass=FinalMeta):
    ser = serial.Serial
    thread = None
    alive = threading.Event()
    file = None
    dev = None
    epWrite = None
    epRead = None
    dialog = None
    helpDialog = None
    authorsDialog = None
    message = []
    manualWorkData = ["0","0"]
    testDataFrame = ["0","0"]
    loadTest = [[],[],[]]
    underWorkFlag = False
    isManualWork =False
    timer = None
    timerIterator = 0

    def __init__(self, parent=None):
        super(MainWindowController, self).__init__(parent)
        self.setupUi(self)
        self.fill_ports_list()
        self.connectSignals()
        self.manualWorkStateChanged(False)
        self.terminal.clear()
        self.tabWidget.widget(1).setEnabled(False)
        self.logSomething("Aby zobaczyc dostepne komendy wpisz: help")

    def fill_ports_list(self):
        for portname in Functions.SerialFunctions.enumerateSerialPorts():
            self.uartPortList.addItem(portname)

    def connectSignals(self):
        self.saveToFile.stateChanged.connect(self.saveToFileStateChanged)
        self.connectButton.clicked.connect(self.connectButtonPushed)
        self.stopButton.clicked.connect(self.stopButtonAction)
        self.manualWork.stateChanged.connect(self.manualWorkStateChanged)
        self.calibrateTens.clicked.connect(self.calibrate)
        self.actionZamknij.triggered.connect(self.closeWindow)
        self.actionPomoc.triggered.connect(self.helpClicked)
        self.actionAutorzy.triggered.connect(self.authorsClicked)
        self.quickSend.clicked.connect(self.interpretLineMessage)
        self.quickMessage.returnPressed.connect(self.interpretLineMessage)
        self.rescanButton.clicked.connect(self.rescanButtonClicked)
        self.actionManual.clicked.connect(self.actionManualClicked)
        self.engOneMin.clicked.connect(self.engOneMinClicked)
        self.engOnePlus.clicked.connect(self.engOnePlusClicked)
        self.engTwoMin.clicked.connect(self.engTwoMinClicked)
        self.engTwoPlus.clicked.connect(self.engTwoPlusClicked)
        self.engBothMin.clicked.connect(self.engBothMinClicked)
        self.engBothPlus.clicked.connect(self.engBothPlusClicked)

    def actionManualClicked(self):
        if self.actionManual.text() == "START":
            self.manualWorkData[0] = str(self.engOneInit.value())
            self.manualWorkData[1] = str(self.engTwoInit.value())
            if self.checkAndSendParameters(self.poleNumber.text(), self.poleNumberTwo.text(), self.safetyTime.value()):
                self.actionManual.setText("STOP")
                self.logSomething('Start pracy manualnej')
        else:
            Utils.ComunicationUtils.sendStop(self.ser)
            self.actionManual.setText("START")
            self.logSomething('Stop pracy manualnej')

    def rescanButtonClicked(self):
        self.uartPortList.clear()
        for portname in Functions.SerialFunctions.enumerateSerialPorts():
            self.uartPortList.addItem(portname)

    def saveToFileStateChanged(self, state):
        if state == 0:
            self.groupBox.setEnabled(False)
            self.logSomething('Zapisywanie plikow wylaczone')
        else:
            self.groupBox.setEnabled(True)
            self.logSomething('Zapisywanie plikow wlaczone')

    def manualWorkStateChanged(self, state):
        if state == 0:
            if not self.underWorkFlag:
                self.manualGroupBox.setEnabled(False)
                self.logSomething('Praca manualna wylaczona')
            else:
                self.logSomething('Nie mozna zmieniac stanu pracy manualnej podczas trwania testu.')
        else:
            if not self.underWorkFlag:
                self.manualGroupBox.setEnabled(True)
                self.logSomething('Praca manualna wlaczona')
                self.isManualWork = True
            else:
                self.logSomething('Nie mozna zmieniac stanu pracy manualnej podczas trwania testu.')

    def connectButtonPushed(self):
        if self.usb_hid.isHidden():
            self.uartConnection(self.uartPortList.currentText(), int(self.uartBaudRateList.currentText()))
        else:
            self.usbHIDConnection(self.vendorID.text(), self.productID.text())

    def uartConnection(self, cur_item, baudrate):
        if self.connectButton.text() == u"Połącz":
            self.connectButton.setText(u"Rozłącz")
            if cur_item is not None:
                fullname = Functions.SerialFunctions.fullPortName(cur_item)
                try:
                    self.tabWidget.setEnabled(False)
                    self.ser = serial.Serial(port=fullname, baudrate=baudrate, timeout=None, writeTimeout=3)
                    self.logSomething('Otwarto port %s' % cur_item)
                    self.StartThread()
                except SerialException as e:
                    self.logSomething('%s error:\n %s' % (cur_item, e))
                    self.tabWidget.setEnabled(True)
                    self.connectButton.setText(u"Połącz")

        else:
            self.connectButton.setText(u"Połącz")
            if self.ser.isOpen():
                self.StopThread()
                self.tabWidget.setEnabled(True)
                self.ser.close()
                self.logSomething('Zamknieto port %s' % cur_item)
                self.ser = None

    def usbHIDConnection(self, vendorIDText, productIDText):
        if vendorIDText is not "" and productIDText is not "" and len(vendorIDText) is 4 and len(productIDText) is 4:
            vendorId = Functions.MiscFunctions.stringToHex(vendorIDText)  # 0x477
            productId = Functions.MiscFunctions.stringToHex(productIDText)  # 0x5620
            if self.connectButton.text() == u"Połącz":
                self.connectButton.setText(u"Rozłącz")
                self.tabWidget.setEnabled(False)
                self.dev = usb.core.find(idVendor=vendorId, idProduct=productId)
                if self.dev is None:
                    raise ValueError('Device not found')
                # get an endpoint instance
                cfg = self.dev.get_active_configuration()
                intf = cfg[(0, 0)]
                self.epWrite = intf[1]
                self.epRead = intf[0]
                assert self.epWrite is not None
                assert self.epRead is not None
                self.StartThread()

            else:
                self.connectButton.setText(u"Połącz")
                self.tabWidget.setEnabled(True)
                self.dev = None
                self.epRead = None
                self.epWrite = None
                self.StopThread()

        elif self.vendorID.text() is "" or self.productID.text() is "":
            self.logSomething('Please, fill all fileds needed to connect via USB HID.')
        else:
            self.logSomething('VendorId or ProductId have incorrect structure. It should consist of 4 characters.')

    def calibrate(self):
        self.logSomething('Kalibracja!')
        self.dialog = CalibrateDialogController()
        self.dialog.calibrateGetValue.clicked.connect(self.dialogGetValueClicked)
        self.dialog.calibrateInsertValue.clicked.connect(self.dialogInsertValueClicked)
        self.dialog.calibrate.clicked.connect(self.dialogCalibrateClicked)
        self.dialog.show()

    def stopButtonAction(self):
        if self.connectButton.text() == u"Rozłącz":
            Utils.ComunicationUtils.sendEmergencyStop(self.ser)
            self.logSomething("Stop awaryjny")
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")

    def StartThread(self):
        """Start the receiver thread"""
        self.thread = threading.Thread(target=self.CommunicationThread)
        self.thread.setDaemon(1)
        self.alive.set()
        self.thread.start()
        self.ser.rts = True
        self.ser.dtr = True

    def StopThread(self):
        """Stop the receiver thread, wait until it's finished."""
        if self.thread is not None:
            self.alive.clear()  # clear alive event for thread
            self.thread.join()  # wait until thread has finished
            self.thread = None

    def CommunicationThread(self):
        """\
        Thread that handles the incoming traffic.
        """
        if self.usb_hid.isHidden():
            Utils.ComunicationUtils.sendConnected(self.ser)
        while self.alive.isSet():
            if self.usb_hid.isHidden():
                data_left = self.ser.inWaiting()
                b = self.ser.read(data_left)
                if len(b) > 0:
                    for i in range(0, len(b)):
                        if type(b[i]) == int:
                            byte = b[i]
                        elif type(b[i]) == str:
                            byte = ord(b[i])
                        if Utils.ComunicationUtils.isStartFrame(byte):
                            self.message = [byte]
                        elif Utils.ComunicationUtils.isStopFrame(byte):
                            self.message.append(byte)
                            self.dataRecieved(self.message)
                        elif len(self.message) > 500:
                            self.message = []
                        else:
                            self.message.append(byte)
            else:
                try:
                    data = self.dev.read(self.epRead, 1000)
                    # print data
                    sret = ''.join([chr(x) for x in data])
                    # print sret
                    self.logSomething(sret)
                except usb.core.USBError as e:
                    data = None
                    if e.args == ('Operation timed out',):
                        continue

    def writeToFile(self, pwm1=None, pwm2 = None, speed1=None, speed2=None, current1=None, current2=None, voltage=None,pressure=None):
        if self.file is not None:
            self.file.write(pwm1)
            self.file.write(';')
            self.file.write(pwm2)
            if (self.saveSpeed.isChecked() or self.saveCurrent.isChecked() or self.saveVoltage.isChecked() or self.savePressure.isChecked()):
                self.file.write(';')
            if self.saveSpeed.isChecked() and speed1 is not None and speed2 is not None:
                self.file.write(speed1)
                self.file.write(';')
                self.file.write(speed2)
                if (self.saveCurrent.isChecked() or self.saveVoltage.isChecked() or self.savePressure.isChecked()):
                    self.file.write(';')
            if self.saveCurrent.isChecked() and current1 is not None and current2 is not None:
                self.file.write(current1)
                self.file.write(';')
                self.file.write(current2)
                if (self.saveVoltage.isChecked() or self.savePressure.isChecked()):
                    self.file.write(';')
            if self.saveVoltage.isChecked() and voltage is not None:
                self.file.write(voltage)
                if (self.savePressure.isChecked()):
                    self.file.write(';')
            if self.savePressure.isChecked() and pressure is not None:
                self.file.write(pressure)
            self.file.write('\n')

    def dialogGetValueClicked(self):
        if self.connectButton.text() == u"Rozłącz":
            Utils.ComunicationUtils.sendGetValue(self.ser)
            self.logSomething("Wyslano rzadanie podania wartosci z tensometru")
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")

    def dialogInsertValueClicked(self):
        self.logSomething("Dodano pomiar!")

    def dialogCalibrateClicked(self):
        if self.connectButton.text() == u"Rozłącz":
            if self.dialog.a is not None:
                Utils.ComunicationUtils.sendFunctionParameters(self.ser, self.dialog.a, self.dialog.b)
                self.logSomething("Wyslano parametry funkcji: y=" + str(self.dialog.a) + "x+" + str(self.dialog.b))
                file = open("config.txt", 'w')
                file.write("ParamA="+str(self.dialog.a)+"\n")
                file.write("ParamB="+str(self.dialog.b)+"\n")
                file.close()
            else:
                self.logSomething("Za malo pomiarow")
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")

    def logSomething(self, string):
        self.terminal.appendPlainText(datetime.now().strftime("%H:%M:%S.%f") + ': ' + string)
        self.terminal.selectAll()
        cursor = self.terminal.textCursor()
        cursor.clearSelection()
        self.terminal.setTextCursor(cursor)
        self.terminal.verticalScrollBar().setValue(self.terminal.verticalScrollBar().maximum())

    def dataRecieved(self, data):
        # string = "[%s]" % ", ".join(map(str, data))
        # self.logSomething(string)
        if (data[1] & Utils.ComunicationUtils.FUNCTION_MASK) == Utils.ComunicationUtils.MEASURE:
            self.getMeassuresAndSaveThem(data)
        elif (data[1] & Utils.ComunicationUtils.FUNCTION_MASK) == Utils.ComunicationUtils.CALIBRATE_GET_VALUE:
            self.logSomething('Otrzymano wartosc')
            self.putValueToCalibrateDialog(data)
        elif (data[1] & Utils.ComunicationUtils.FUNCTION_MASK) == Utils.ComunicationUtils.SET_TEST_PARAMS:
            self.openFileAndStartTest()
        elif (data[1] & Utils.ComunicationUtils.FUNCTION_MASK) == Utils.ComunicationUtils.CONNECTION:
            self.connectedToDevice()
        elif (data[1] & Utils.ComunicationUtils.FUNCTION_MASK) == Utils.ComunicationUtils.START_TEST:
            self.startTestRecieved()
        elif (data[1] & Utils.ComunicationUtils.FUNCTION_MASK) == Utils.ComunicationUtils.STOP_TEST:
            self.testStopped()
        else:
            self.logSomething('Nieznany komunikat')

    def startTestRecieved (self):
        self.logSomething('Start testu')
        self.underWorkFlag = True
        if self.isManualWork:
            Utils.ComunicationUtils.sendPWMFrame(self.ser,self.manualWorkData)
        else:
            self.timerIterator = 0
            self.testDataFrame = [self.loadTest[0][self.timerIterator],self.loadTest[1][self.timerIterator]]
            Utils.ComunicationUtils.sendPWMFrame(self.ser,self.testDataFrame)
            self.timer = threading.Timer(float(self.loadTest[2][self.timerIterator])/1000,self.timerInterrupt)
            self.timer.start()

    def timerInterrupt (self):
        self.timer.cancel()
        self.timerIterator += 1
        if self.timerIterator < len(self.loadTest[0]):
            self.testDataFrame = [self.loadTest[0][self.timerIterator],self.loadTest[1][self.timerIterator]]
            Utils.ComunicationUtils.sendPWMFrame(self.ser,self.testDataFrame)
            self.timer = threading.Timer(float(self.loadTest[2][self.timerIterator])/1000,self.timerInterrupt)
            self.timer.start()
        elif self.timerIterator == len(self.loadTest[0]):
            Utils.ComunicationUtils.sendStop(self.ser)

    def testStopped (self):
        self.groupBox.setEnabled(True)
        self.saveToFile.setEnabled(True)
        self.logSomething("Koniec testu")
        if self.file is not None:
            self.logSomething('Zamknieto plik')
            self.file.close()
            self.file = None
        if self.actionManual.text() == "STOP":
            self.actionManual.setText("START")
        self.underWorkFlag = False

    def connectedToDevice (self):
        self.logSomething("Podlaczono do urzadzenia")
        try:
            f = open("config.txt",'r')
            self.logSomething("Wczytano plik konfiguracyjny.")
            firstLine = f.readline()
            splitOne = firstLine.split("=")
            paramA = float(splitOne[1])
            secondLine = f.readline()
            splitTwo = secondLine.split("=")
            paramB = float(splitTwo[1])
            Utils.ComunicationUtils.sendFunctionParameters(self.ser, paramA, paramB)
            f.close()
        except FileNotFoundError as e:
            self.logSomething("Nie znaleziono pliku konfiguracyjnego.")
            self.logSomething('Przed rozpoczeciem testow skalibruj tensometr.')

    def openFileAndStartTest (self):
        if self.groupBox.isEnabled():
            self.groupBox.setEnabled(False)
            self.saveToFile.setEnabled(False)
            if self.fileName.text() is not None and self.fileName.text() != "":
                filename = self.fileName.text() + ".txt"
                self.file = open(filename, 'w')
                self.writeToFile('pwm1', 'pwm2', 'n1', 'n2', 'I1', 'I2', 'U', 'm')
            else:
                self.logSomething("Test zostanie zapisany z nazwa aktualnej daty")
                self.file = open(datetime.now().strftime("%y%m%d%H%M%S") + ".txt", 'w')
                self.writeToFile('pwm1', 'pwm2', 'n1', 'n2', 'I1', 'I2', 'U', 'm')
        Utils.ComunicationUtils.sendStartTest(self.ser)

    def checkAndSendParameters(self, poleNumberText, poleNumberTwoText, safetyTime):
        if self.connectButton.text() == u"Rozłącz":
            if self.poleNumber is not None:
                pNumber = int(poleNumberText)
                pNumber2 = int(poleNumberTwoText)
            if pNumber > 1:
                Utils.ComunicationUtils.sendTestParameters(self.ser, pNumber, pNumber2, safetyTime)
                self.logSomething("Parametry testu wyslane")
                return True
            else:
                self.logSomething("Zla wartosc liczby par biegunow")
                return False
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")
            return False

    def putValueToCalibrateDialog(self, data):
        i = data[1] & Utils.ComunicationUtils.NUMBER_MASK
        i += 2
        meassure = 0
        # meassure = (data[2] & Utils.ComunicationUtils.DATA_MASK)+((data[3] & Utils.ComunicationUtils.DATA_MASK)<<7)+((data[4] & Utils.ComunicationUtils.DATA_MASK)<<14)
        for j in range(2, i):
            jumpBit = (7 * (j - 2))
            parsedData = (data[j] & Utils.ComunicationUtils.DATA_MASK)
            meassure += parsedData << jumpBit
        self.dialog.measure = meassure
        self.dialog.measurements.setText(str(meassure))

    def getMeassuresAndSaveThem(self, data):
        i = data[1] & Utils.ComunicationUtils.NUMBER_MASK
        i += 2
        n1 = 0
        n2 = 0
        for j in range(2, i):
            if j < 2 + ((i - 2) / 2):
                jumpBit = (7 * (j - 2))
                parsedData = (data[j] & Utils.ComunicationUtils.DATA_MASK)
                n1 += parsedData << jumpBit
            else:
                jumpBit = int(7 * (j - 2 - ((i - 2) / 2)))
                parsedData = (data[j] & Utils.ComunicationUtils.DATA_MASK)
                n2 += parsedData << jumpBit
        oldI = i
        i += data[i] & Utils.ComunicationUtils.NUMBER_MASK
        i += 1
        i1 = ((data[oldI + 1] & Utils.ComunicationUtils.DATA_MASK) + float("{0:.2f}".format((
        (data[oldI + 2] & Utils.ComunicationUtils.DATA_MASK) / 100 - int((
        (data[oldI + 2] & Utils.ComunicationUtils.DATA_MASK) / 100))))))
        i2 = ((data[oldI + 3] & Utils.ComunicationUtils.DATA_MASK) + float("{0:.2f}".format(((
        (data[oldI + 4] & Utils.ComunicationUtils.DATA_MASK) / 100)- int((
        (data[oldI + 4] & Utils.ComunicationUtils.DATA_MASK) / 100))))))
        v = ((data[oldI + 5] & Utils.ComunicationUtils.DATA_MASK) + float("{0:.2f}".format((
        (data[oldI + 6] & Utils.ComunicationUtils.DATA_MASK) / 100- int((
        (data[oldI + 6] & Utils.ComunicationUtils.DATA_MASK) / 100))))))
        oldI = i + 1
        i += data[i] & Utils.ComunicationUtils.NUMBER_MASK
        i += 1
        p = 0
        #PWM1 i PWM2 w ramce z naciskiem
        for j in range(oldI+1, oldI+4):
            jumpBit = (7 * (j - (oldI+1)))
            parsedData = (data[j] & Utils.ComunicationUtils.DATA_MASK)
            p += parsedData << jumpBit
        if (data[oldI] & Utils.ComunicationUtils.DATA_MASK) == 0x01:
            p*=(-1)
        pwm1 = (data[oldI+4] & Utils.ComunicationUtils.DATA_MASK)
        pwm2 = (data[oldI+5] & Utils.ComunicationUtils.DATA_MASK)
        self.printMeasuresInLabels(str(pwm1), str(pwm2), str(n1), str(n2), str(i1), str(i2), str(v), str(p))
        self.writeToFile(str(pwm1), str(pwm2), str(n1), str(n2), str(i1), str(i2), str(v), str(p))

    def closeWindow(self):
        self.close()

    def helpClicked(self):
        self.helpDialog = HelpDialogController()
        self.helpDialog.show()

    def authorsClicked(self):
        self.auhtorsDialog = AuthorsDialogController()
        self.auhtorsDialog.show()

    def printMeasuresInLabels(self, pwm1, pwm2, speed1, speed2, current1, current2, voltage, pressure):
        self.PWMFirstMeter.setText(pwm1)
        self.PWMSecondMeter.setText(pwm2)
        self.speedMeterN1.setText(speed1)
        self.speedMeterN2.setText(speed2)
        self.currentMeterI1.setText(current1)
        self.currentMeterI2.setText(current2)
        self.voltageMeter.setText(voltage)
        self.pressureMeter.setText(pressure)

    def interpretLineMessage(self):
        message = self.quickMessage.text()
        self.logSomething("CMD: " + message)
        spl = message.split(' ')
        if spl[0] == Utils.CommandUtils.CONNECT_COMMAND:
            self.interpretConnectComman(spl)
        elif spl[0] == Utils.CommandUtils.START_COMMAND:
            self.interpretStartCommand(spl)
        elif spl[0] == Utils.CommandUtils.HELP_COMMAND:
            self.interpretHelpCommand(spl)
        elif spl[0] == Utils.CommandUtils.LOAD_COMMAND:
            self.interpretLoadCommand(spl)
        elif spl[0] == Utils.CommandUtils.STOP_COMMAND:
            self.interpretStopCommand(spl)
        elif spl[0] == Utils.CommandUtils.CLEAR_COMMAND:
            self.interpretClearCommand(spl)
        elif spl[0] == "crash":
            crashThisShit()
        else:
            self.logSomething("Bledna komenda")
        self.quickMessage.clear()

    def interpretClearCommand(self,spl):
        if len(spl) is 1:
            self.terminal.clear()
        else:
            self.logSomething("Bledna liczba przesylanych danych")

    def interpretConnectComman(self, spl):
        if len(spl) is 4:
            if spl[1] == "uart":
                self.uartConnection(spl[2], spl[3])
            elif spl[1] == "usb":
                self.usbHIDConnection(spl[2], spl[3])
            else:
                self.logSomething("Bledne parametry")
        else:
            self.logSomething("Bledna liczba przesylanych danych")

    def interpretStartCommand(self, spl):
        if len(spl) is 2:
            if spl[1] == "manual" and not self.underWorkFlag:
                if not self.manualWork.isChecked():
                    self.manualWork.setChecked(True)
                if self.actionManual.text() == "START":
                    self.manualWorkData[0] = str(self.engOneInit.value())
                    self.manualWorkData[1] = str(self.engTwoInit.value())
                    if self.checkAndSendParameters(self.poleNumber.text(), self.poleNumberTwo.text(), self.safetyTime.value()):
                        self.actionManual.setText("STOP")
                        self.logSomething('Start pracy manualnej')
            elif spl[1] == "test" and not self.underWorkFlag:
                if len(self.loadTest[0]) > 0:
                    if self.manualWork.isChecked():
                        self.manualWork.setChecked(False)
                    if self.isManualWork:
                        self.isManualWork = False
                    if self.checkAndSendParameters(self.poleNumber.text(), self.poleNumberTwo.text(), self.safetyTime.value()):
                        self.logSomething('Start testu')
                else:
                    self.logSomething('Test nie zostal zaladowany, lub zaladowal sie blednie')

        else:
            self.logSomething("Bledna liczba przesylanych danych")

    def interpretHelpCommand(self, spl):
        if len(spl) is 1:
            self.logSomething("Pierwszy czlon to komenda, kolejne czlony to parametry")
            self.logSomething("connect [uart,usb] [serialport,vendorId] [baudrate,productId] - polaczenie do portu")
            self.logSomething("load [file.txt, absolut_path\\file.txt] - wczytanie testu z pliku")
            self.logSomething("start [manual, test] - start testu lub pracy manualnej")
            self.logSomething("stop [manual] - stop pracy manualnej")
            self.logSomething("clear - czyszcenie termianala")
        else:
            self.logSomething("Bledna liczba przesylanych danych")

    def interpretLoadCommand(self,spl):
        if len(spl) is 2:
            try:
                f = open(spl[1],'r')
                self.logSomething("Wczytano test z pliku.")
                testText = f.read()
                commands = testText.split(' ')
                if self.checkIfCommandsHaveCorrectShape(commands):
                    for i in range(0,len(commands)):
                        pwmFirst = commands[i].split(',')[0][1:]
                        pwmSecond = commands[i].split(',')[1]
                        time = commands[i].split(',')[2][:-1]
                        if  self.checkIfParamsAreCorrect(pwmFirst,pwmSecond,time,i):
                            if i is 0:
                                self.loadTest = [[],[],[]]
                            self.loadTest[0].append(pwmFirst)
                            self.loadTest[1].append(pwmSecond)
                            self.loadTest[2].append(time)
                            if i is len(commands)-1:
                                self.logSomething("Parametry testu zostaly wczytane poprawnie.")


            except FileNotFoundError as e:
                self.logSomething("Nie znaleziono pliku.")

        else:
            self.logSomething("Bledna liczba przesylanych danych")

    def interpretStopCommand(self,spl):
        if len(spl) is 2:
            if spl[1] == "manual":
                if self.actionManual.text() == "STOP":
                    Utils.ComunicationUtils.sendStop(self.ser)
                    self.actionManual.setText("START")
                    self.logSomething('Stop pracy manualnej')
        else:
            self.logSomething("Bledna liczba przesylanych danych")

    def checkIfParamsAreCorrect(self,pwmFirst,pwmSecond,time,i):
        if int(pwmFirst) < 0 or int(pwmFirst) > 100:
            self.logSomething("Blad: W "+ (i+1) + " komendzie 1 parametr jest niepoprawny.")
            return False
        if int(pwmSecond) < 0 or int(pwmSecond) > 100:
            self.logSomething("Blad: W "+ (i+1) + " komendzie 2 parametr jest niepoprawny.")
            return False
        if int(time) < 100:
            self.logSomething("Blad: W "+ (i+1) + " komendzie 3 parametr jest niepoprawny.")
            return False
        return True

    def checkIfCommandsHaveCorrectShape(self,commands):
        for i in range(0,len(commands)):
            if len(commands[i].split(',')) is not 3:
                self.logSomething("Blad: " +(i+1)+ " komenda jest niepoprawna.")
                return False
            if commands[i][0] != "[" and commands[i][len(commands[i])-1] != "]":
                self.logSomething("Blad: " +(i+1)+ " komenda jest niepoprawna.")
                return False
            return True

    def engOneMinClicked(self):
        self.manualWorkData[0] = self.manualEquation(self.manualWorkData[0], self.engOneJump.value(), True)
        self.sendManualDataWork()

    def engOnePlusClicked(self):
        self.manualWorkData[0] = self.manualEquation(self.manualWorkData[0], self.engOneJump.value(), False)
        self.sendManualDataWork()

    def engTwoMinClicked(self):
        self.manualWorkData[1] = self.manualEquation(self.manualWorkData[1], self.engTwoJump.value(), True)
        self.sendManualDataWork()

    def engTwoPlusClicked(self):
        self.manualWorkData[1] = self.manualEquation(self.manualWorkData[1], self.engTwoJump.value(), False)
        self.sendManualDataWork()

    def engBothMinClicked(self):
        self.doubleManualEquation(True)
        self.sendManualDataWork()

    def engBothPlusClicked(self):
        self.doubleManualEquation(False)
        self.sendManualDataWork()

    def manualEquation(self, data, jump, sub):
        if self.connectButton.text() == u"Rozłącz":
            if sub:
                number = int(data) - jump
                if number < 0:
                    number = 0
                data = str(number)
                return data
            else:
                number = int(data) + jump
                if number > 100:
                    number = 100
                data = str(number)
                return data
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")
            return data

    def doubleManualEquation(self, sub):
        if self.connectButton.text() == u"Rozłącz":
            if sub:
                number1 = int(self.manualWorkData[0]) - self.engBothJump.value()
                number2 = int(self.manualWorkData[1]) - self.engBothJump.value()
                if number1 < 0:
                    number1 = 0
                if number2 < 0:
                    number2 = 0
                self.manualWorkData[0] = str(number1)
                self.manualWorkData[1] = str(number2)
            else:
                number1 = int(self.manualWorkData[0]) + self.engBothJump.value()
                number2 = int(self.manualWorkData[1]) + self.engBothJump.value()
                if number1 > 100:
                    number1 = 100
                if number2 > 100:
                    number2 = 100
                self.manualWorkData[0] = str(number1)
                self.manualWorkData[1] = str(number2)
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")

    def sendManualDataWork(self):
        if self.connectButton.text() == u"Rozłącz":
            Utils.ComunicationUtils.sendPWMFrame(self.ser, self.manualWorkData)
        else:
            self.logSomething("Polaczenie nie zostalo nawiazane")

    def closeEvent(self,event):
        self.logSomething('Program zostal zamkniety')
        if self.file is not None:
            self.logSomething('Zamknieto plik')
            self.file.close()
            self.file = None
        if self.connectButton.text() == u"Rozłącz":
            self.connectButtonPushed()