import os
from datetime import datetime, timedelta
from com.ericsson.xn.commons import caseutils
from com.ericsson.xn.x.pm.PmCommons import PmBaseFunc

sep = os.sep
module_name = os.path.split(os.path.abspath(__file__))[1][:-3]
# Pre of the test case
caseutils.pre_test_case(module_name, 'pm_automation')

root_dir = os.path.dirname(os.path.abspath(__file__)).split(
    'x' + sep + 'pm' + sep + 'test_cases', 1)[0]
ne_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                               'nes' + sep + 'ltehss.cfg')
counter_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                    'counters' + sep + 'ltehss.cfg')
me_counter_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                  'me_counters' + sep + 'ltehss.cfg')
me_types_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                'me_types' + sep + 'ltehss.cfg')
server_info_path = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                    'execute_conf.cfg')
t_now = datetime.now()
end_time = t_now + timedelta(minutes=-(t_now.minute % 5 + 14))
str_end_time = end_time.strftime('%Y-%m-%d %H:%M') + ":00"
PmBaseFunc.check_pm_accurate(ne_info_cfg, counter_info_cfg, server_info_path,
                             str_end_time, 2, 12, me_counter_cfg, me_types_cfg)

# Post of the test case
caseutils.post_test_case()
Beispiel #2
0
# -*- coding: utf-8 -*-

import os
from datetime import datetime, timedelta
from com.ericsson.xn.commons import caseutils
from com.ericsson.xn.x.pm.PmCommons import PmBaseFunc

sep = os.sep
module_name = os.path.split(os.path.abspath(__file__))[1][:-3]
# Pre of the test case
caseutils.pre_test_case(module_name, 'pm_automation')

root_dir = os.path.dirname(os.path.abspath(__file__)).split(
    'x' + sep + 'pm' + sep + 'test_cases', 1)[0]
ne_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                               'nes' + sep + 'pgw.cfg')
counter_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                    'counters' + sep + 'pgw.cfg')
# me_counter_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'me_counters' + sep + 'ltehss.cfg')
server_info_path = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                    'execute_conf.cfg')
t_now = datetime.now()
end_time = t_now + timedelta(minutes=-(t_now.minute % 5 + 14))
str_end_time = end_time.strftime('%Y-%m-%d %H:%M') + ":00"
PmBaseFunc.check_pm_accurate(ne_info_cfg, counter_info_cfg, server_info_path,
                             str_end_time, 1)

# Post of the test case
caseutils.post_test_case()
# -*- coding: utf-8 -*-

import os
from datetime import datetime, timedelta
from com.ericsson.xn.commons import caseutils
from com.ericsson.xn.x.pm.PmCommons import PmBaseFunc

sep = os.sep
module_name = os.path.split(os.path.abspath(__file__))[1][:-4]
# Pre of the test case
caseutils.pre_test_case(module_name, 'pm_automation')

root_dir = os.path.dirname(os.path.abspath(__file__)).split('x' + sep + 'pm' + sep + 'test_cases', 1)[0]
ne_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'nes' + sep + 'imshss.cfg')
counter_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'counters' + sep + 'imshss.cfg')
me_counter_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'me_counters' + sep + 'imshss.cfg')
me_types_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'me_types' + sep + 'imshss.cfg')
server_info_path = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'execute_conf.cfg')
t_now = datetime.now()
end_time = t_now + timedelta(minutes=-(t_now.minute % 5 + 14))
str_end_time = end_time.strftime('%Y-%m-%d %H:%M') + ":00"
PmBaseFunc.check_pm_accurate(ne_info_cfg, counter_info_cfg, server_info_path, str_end_time, 4, 12,
                             me_counter_cfg, me_types_cfg)

# Post of the test case.
caseutils.post_test_case()
Beispiel #4
0
# -*- coding: utf-8 -*-

import os
from datetime import datetime, timedelta
from com.ericsson.xn.commons import caseutils
from com.ericsson.xn.x.pm.PmCommons import PmBaseFunc

sep = os.sep
module_name = os.path.split(os.path.abspath(__file__))[1][:-3]
# Pre of the test case
caseutils.pre_test_case(module_name, 'pm_automation')

root_dir = os.path.dirname(os.path.abspath(__file__)).split('x' + sep + 'pm' + sep + 'test_cases', 1)[0]
ne_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'nes' + sep + 'mme.cfg')
counter_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'counters' + sep + 'mme.cfg')
# me_counter_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'me_counters' + sep + 'ltehss.cfg')
server_info_path = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'execute_conf.cfg')
t_now = datetime.now()
end_time = t_now + timedelta(minutes=-(t_now.minute % 5 + 14))
str_end_time = end_time.strftime('%Y-%m-%d %H:%M') + ":00"
PmBaseFunc.check_pm_accurate(ne_info_cfg, counter_info_cfg, server_info_path, str_end_time, 1)

# Post of the test case
caseutils.post_test_case()
Beispiel #5
0
# -*- coding: utf-8 -*-

import os
from datetime import datetime, timedelta
from com.ericsson.xn.commons import caseutils
from com.ericsson.xn.x.pm.PmCommons import PmBaseFunc

sep = os.sep
module_name = os.path.split(os.path.abspath(__file__))[1][:-3]
# Pre of the test case
caseutils.pre_test_case(module_name, 'pm_automation')

root_dir = os.path.dirname(os.path.abspath(__file__)).split('x' + sep + 'pm' + sep + 'test_cases', 1)[0]
ne_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'nes' + sep + 'sbc.cfg')
counter_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'counters' + sep + 'sbc.cfg')
# me_counter_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'me_counters' + sep + 'ltehss.cfg')
server_info_path = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'execute_conf.cfg')
PmBaseFunc.check_sbc_pm(ne_info_cfg, counter_info_cfg, server_info_path, 1, 3)

# Post of the test case
caseutils.post_test_case()
# -*- coding: utf-8 -*-

import os
from datetime import datetime, timedelta
from com.ericsson.xn.commons import caseutils
from com.ericsson.xn.x.pm.PmCommons import PmBaseFunc

sep = os.sep
module_name = os.path.split(os.path.abspath(__file__))[1][:-3]
# Pre of the test case
caseutils.pre_test_case(module_name, 'pm_automation')

root_dir = os.path.dirname(os.path.abspath(__file__)).split(
    'x' + sep + 'pm' + sep + 'test_cases', 1)[0]
ne_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                               'nes' + sep + 'sbc.cfg')
counter_info_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                    'counters' + sep + 'sbc.cfg')
# me_counter_cfg = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep + 'me_counters' + sep + 'ltehss.cfg')
server_info_path = os.path.normpath(root_dir + sep + 'x' + sep + 'pm' + sep +
                                    'execute_conf.cfg')
PmBaseFunc.check_sbc_pm(ne_info_cfg, counter_info_cfg, server_info_path, 1, 3)

# Post of the test case
caseutils.post_test_case()