def test_01_Devcat(self): l_dev = b'\x02\x04' l_ret = utilDecode._devcat(l_dev, self.m_obj) self.assertEqual(self.m_obj.DevCat, 0x0204) # l_dev = MSG_50 # l_c = l_dev[5:7] # print(FormatBytes(l_c)) l_ret = utilDecode._devcat(l_dev[5:7], self.m_obj) self.assertEqual(self.m_obj.DevCat, 0x0204)
def test_01_Devcat(self): l_dev = b'\x02\x04' l_ret = utilDecode._devcat(l_dev, self.m_obj) self.assertEqual(self.m_obj.DevCat, 0x0204) # l_dev = MSG_50 # l_c = l_dev[5:7] # print(FormatBytes(l_c)) l_ret = utilDecode._devcat(l_dev[5:7], self.m_obj) self.assertEqual(self.m_obj.DevCat, 0x0204)
def test_01_Devcat(self): l_dev = b'\x02\x04' _l_ret = utilDecode._devcat(l_dev, self.m_obj) # print(PrettyFormatAny.form(_l_ret, 'D1-01-A - xxx')) self.assertEqual(self.m_obj.DevCat, 0x0204) # l_dev = MSG_50 # l_c = l_dev[5:7] # print(FormatBytes(l_c)) _l_ret = utilDecode._devcat(l_dev[5:7], self.m_obj) self.assertEqual(self.m_obj.DevCat, 0x0204)
def decode_53(p_controller_obj): """Insteon All-Linking completed (10 bytes). See p 245(258) of 2007 developers guide. """ l_message = p_controller_obj._Message l_link_code = l_message[2] l_link_group = l_message[3] l_from_id = l_message[4:7] utilDecode._devcat(l_message[7:9], p_controller_obj) LOG.info('All-Linking completed {}, Group:{}, From:{} '.format(l_link_code, l_link_group, l_from_id)) return False
def decode_0x53(p_pyhouse_obj, p_controller_obj): """Insteon All-Linking completed (10 bytes). See p 247(260) of 2009 developers guide. [0] = 0x02 [1] = 0x53 [2] = LinkCode - 0=PLM is Responder, 1=PLM is Controller, FF=Deleted [3] = LinkGroup [4-6] = from address [7-8] = DevCat [9] = Firmwear Version """ l_message = p_controller_obj._Message l_msg = Insteon_utils.decode_link_code(l_message[2]) l_link_group = l_message[3] l_from_id = l_message[4:7] l_device_obj = utilDecode.get_obj_from_message(p_pyhouse_obj, l_from_id) utilDecode._devcat(l_message[7:9], p_controller_obj) _l_version = l_message[9] LOG.info('All-Linking completed - Link Code:{}, Group:{}, From:{} '.format(l_msg, l_link_group, l_device_obj.Name))
def decode_0x50(self, p_pyhouse_obj, p_device_obj, p_controller_obj): """ @param p_device_obj: is the Device (GDO, Motion...) we are decoding. A Standard-length INSTEON message is received from either a Controller or Responder that you are ALL-Linked to. See p 233(246) of 2009 developers guide. [0] = x02 [1] = 0x50 [2-4] = from address [5-7] = to address / group [8] = message flags [9] = command 1 [10] = command 2 """ l_device = SensorMessage(p_device_obj.Name, p_device_obj.RoomName, 'Generic ') l_mqtt_topic = 'security/' l_mqtt_msg = 'security ' if p_device_obj.DeviceSubType == 1: l_mqtt_msg += 'Garage Door: ' l_device.Type = 'Garage Door' l_mqtt_topic += 'garage_door' elif p_device_obj.DeviceSubType == 2: l_mqtt_msg += 'Motion Sensor: ' l_device.Type = 'Motion Sensor' l_mqtt_topic += 'motion_sensor' # l_message = p_controller_obj._Message l_firmware = l_message[7] l_flags = utilDecode._decode_message_flag(l_message[8]) l_cmd1 = l_message[9] l_cmd2 = l_message[10] l_data = [l_cmd1, l_cmd2] l_mqtt_msg += 'Fm:"{}"; Flg:{}; C1:{:#x},{:#x}; '.format(p_device_obj.Name, l_flags, l_cmd1, l_cmd2) if l_message[8] & 0xE0 == 0x80: # 100 - SB [Broadcast] l_mqtt_msg += utilDecode._devcat(l_message[5:7], p_device_obj) elif l_message[8] & 0xE0 == 0xC0: # 110 - SA Broadcast = all link broadcast of group id l_group = l_message[7] l_mqtt_msg += 'A-L-brdcst-Gp:"{}","{}"; '.format(l_group, l_data) if l_cmd1 == MESSAGE_TYPES['cleanup_success']: # 0x06 l_mqtt_msg += 'CleanupSuccess with {} failures; '.format(l_cmd2) elif l_cmd1 == MESSAGE_TYPES['engine_version']: # 0x0D p_device_obj.EngineVersion = l_cmd2 l_mqtt_msg += 'Engine-version:"{}"; '.format(l_cmd2) elif l_cmd1 == MESSAGE_TYPES['id_request']: # 0x10 p_device_obj.FirmwareVersion = l_firmware l_mqtt_msg += 'Request-ID-From:"{}"; '.format(p_device_obj.Name) elif l_cmd1 == MESSAGE_TYPES['on']: # 0x11 if p_device_obj.DeviceSubType == 1: # The status turns on when the Garage Door goes closed l_mqtt_msg += 'Garage Door Closed; '.format(p_device_obj.Name) p_device_obj.Status = 'Close' l_device.Status = 'Garage Door Closed.' elif p_device_obj.DeviceSubType == 2: l_mqtt_msg += 'Motion Detected; '.format(p_device_obj.Name) l_device.Status = 'Motion Detected.' else: l_mqtt_msg += 'Unknown SubType {} for Device; '.format(p_device_obj.DeviceSubType, p_device_obj.Name) if ((l_message[8] & 0xE0) >> 5) == 6: p_pyhouse_obj.APIs.Computer.MqttAPI.MqttPublish(l_mqtt_topic, l_device) # /security elif l_cmd1 == MESSAGE_TYPES['off']: # 0x13 if p_device_obj.DeviceSubType == 1: l_mqtt_msg += 'Garage Door Opened; '.format(p_device_obj.Name) p_device_obj.Status = 'Opened' l_device.Status = 'Garage Door Opened.' elif p_device_obj.DeviceSubType == 2: l_mqtt_msg += 'NO Motion; '.format(p_device_obj.Name) l_device.Status = 'Motion Stopped.' else: l_mqtt_msg += 'Unknown SubType {} for Device; '.format(p_device_obj.DeviceSubType, p_device_obj.Name) if ((l_message[8] & 0xE0) >> 5) == 6: p_pyhouse_obj.APIs.Computer.MqttAPI.MqttPublish(l_mqtt_topic, l_device) # /security LOG.info('Security {}'.format(l_mqtt_msg)) Insteon_utils.update_insteon_obj(p_pyhouse_obj, p_device_obj) return
def _decode_0x50(self, p_controller_obj): """ Insteon Standard Message Received (11 bytes) A Standard-length INSTEON message is received from either a Controller or Responder that you are ALL-Linked to. See p 233(246) of 2009 developers guide. [0] = x02 [1] = 0x50 [2-4] = from address [5-7] = to address / group [8] = message flags [9] = command 1 [10] = command 2 """ l_mqtt = False l_message = p_controller_obj._Message l_device_obj = utilDecode.get_obj_from_message(self.m_pyhouse_obj, l_message[2:5]) l_device_obj.BrightnessPct = '?' if l_device_obj.DeviceType == 2: # HVAC Type DecodeHvac().decode_0x50(self.m_pyhouse_obj, l_device_obj, p_controller_obj) return if l_device_obj.DeviceType == 3: # Security Type DecodeSecurity().decode_0x50(self.m_pyhouse_obj, l_device_obj, p_controller_obj) return l_flags = utilDecode._decode_message_flag(l_message[8]) l_cmd1 = l_message[9] l_cmd2 = l_message[10] l_data = [l_cmd1, l_cmd2] l_debug_msg = 'Fm:"{}"; Flg:{}; C1:{:#x},{:#x}; '.format(l_device_obj.Name, l_flags, l_cmd1, l_cmd2) # # Break down bits 7(msb), 6, 5 into message type # if l_message[8] & 0xE0 == 0x80: # 100 - SB [Broadcast] l_debug_msg += utilDecode._devcat(l_message[5:7], l_device_obj) elif l_message[8] & 0xE0 == 0xC0: # 110 - SA Broadcast = all link broadcast of group id l_group = l_message[7] l_debug_msg += 'A-L-brdcst-Gp:"{}","{}"; '.format(l_group, l_data) try: if l_cmd1 == MESSAGE_TYPES['product_data_request']: # 0x03 l_debug_msg += " Product-data-request." elif l_cmd1 == MESSAGE_TYPES['cleanup_success']: # 0x06 l_debug_msg += 'CleanupSuccess with {} failures; '.format(l_cmd2) elif l_cmd1 == MESSAGE_TYPES['engine_version']: # 0x0D l_device_obj.EngineVersion = l_cmd2 l_debug_msg += 'Engine-version:"{}(i-{})"; '.format(l_cmd2, l_cmd2 + 1) elif l_cmd1 == MESSAGE_TYPES['id_request']: # 0x10 l_device_obj.FirmwareVersion = l_cmd2 l_debug_msg += 'Request-ID:"{}"; '.format(l_device_obj.FirmwareVersion) elif l_cmd1 == MESSAGE_TYPES['on']: # 0x11 l_device_obj.BrightnessPct = 100 l_mqtt = True l_debug_msg += 'Turn ON; '.format(l_device_obj.Name) elif l_cmd1 == MESSAGE_TYPES['off']: # 0x13 l_device_obj.BrightnessPct = 0 l_mqtt = True l_debug_msg += 'Turn OFF; '.format(l_device_obj.Name) elif l_cmd1 == MESSAGE_TYPES['status_request']: # 0x19 l_device_obj.BrightnessPct = l_level = utilDecode.decode_light_brightness(l_cmd2) l_debug_msg += 'Status of light:"{}"-level:"{}"; '.format(l_device_obj.Name, l_level) elif l_message[8] & 0xE0 == 0x80 and l_cmd1 == 0x01: l_debug_msg += ' Device-Set-Button-Pressed ' elif l_message[8] & 0xE0 == 0x80 and l_cmd1 == 0x02: l_debug_msg += ' Controller-Set-Button-Pressed ' else: l_debug_msg += '\n\tUnknown-type -"{}"; '.format(FormatBytes(l_message)) l_device_obj.BrightnessPct = utilDecode.decode_light_brightness(l_cmd2) l_mqtt = True except AttributeError as e_err: LOG.error('ERROR decoding 0x50 record {}'.format(e_err)) Insteon_utils.update_insteon_obj(self.m_pyhouse_obj, l_device_obj) p_controller_obj.Ret = True LOG.info('{}'.format(l_debug_msg)) if l_mqtt: self.m_pyhouse_obj.APIs.Computer.MqttAPI.MqttPublish('lighting/status/debug', l_device_obj) # /lig return
def _decode_50_record(self, p_controller_obj): """ Insteon Standard Message Received (11 bytes) A Standard-length INSTEON message is received from either a Controller or Responder that you are ALL-Linked to. See p 233(246) of developers guide. [0] = x02 [1] = 0x50 [2-4] = from address [5-7] = to address / group [8] = message flags [9] = command 1 [10] = command 2 """ l_message = p_controller_obj._Message l_device_obj = utilDecode.get_obj_from_message(self.m_pyhouse_obj, l_message[2:5]) l_flags = utilDecode._decode_message_flag(l_message[8]) l_cmd1 = l_message[9] l_cmd2 = l_message[10] l_data = [l_cmd1, l_cmd2] # print(PrettyFormatAny.form(l_device_obj, 'Insteon_decoder 156 - Device')) if l_device_obj.DeviceType == 2: Insteon_HVAC.ihvac_utility().decode_50_record(self.m_pyhouse_obj, l_device_obj, p_controller_obj) return self.check_for_more_decoding(p_controller_obj, True) l_debug_msg = 'Std Msg fm: {}; Cmd1:{:#x}, Cmd2:{:#x}; '.format(l_device_obj.Name, l_cmd1, l_cmd2) # Break down bits 7(msb), 6, 5 into message type if l_message[8] & 0xE0 == 0x80: # Broadcast/NAK Message (100) l_debug_msg += utilDecode._devcat(l_message[5:7], l_device_obj) elif l_message[8] & 0xE0 == 0xC0: # (110) all link broadcast of group id l_group = l_message[7] l_debug_msg += "All-Link broadcast - Group:{}, Data:{}; ".format(l_group, l_data) LOG.info("== 50B All-link Broadcast Group:{}, Data:{} ==".format(l_group, l_data)) # try: if l_cmd1 == MESSAGE_TYPES['product_data_request']: # 0x03 l_debug_msg += " product data request. - Should never happen - S/B 51 response" elif l_cmd1 == MESSAGE_TYPES['engine_version']: # 0x0D l_engine_id = l_cmd2 l_device_obj.EngineVersion = l_engine_id l_debug_msg += "Engine version is: {}; ".format(l_engine_id) self._publish(self.m_pyhouse_obj, l_device_obj) elif l_cmd1 == MESSAGE_TYPES['id_request']: # 0x10 l_debug_msg += "Request ID From: {}; ".format(l_device_obj.Name) # LOG.info("Got an ID request. Light:{}".format(l_device_obj.Name,)) elif l_cmd1 == MESSAGE_TYPES['on']: # 0x11 l_device_obj.CurLevel = 100 l_debug_msg += "Device:{} turned Full ON ; ".format(l_device_obj.Name) self._publish(self.m_pyhouse_obj, l_device_obj) elif l_cmd1 == MESSAGE_TYPES['off']: # 0x13 l_device_obj.CurLevel = 0 l_debug_msg += "Light:{} turned Full OFF; ".format(l_device_obj.Name) self._publish(self.m_pyhouse_obj, l_device_obj) elif l_cmd1 == MESSAGE_TYPES['status_request']: # 0x19 l_level = int(((l_cmd2 + 2) * 100) / 256) l_device_obj.CurLevel = l_level l_debug_msg += "Status of light:{} is level:{}; ".format(l_device_obj.Name, l_level) LOG.info("PLM:{} Got Light Status From:{}, Level is:{} ".format(p_controller_obj.Name, l_device_obj.Name, l_level)) elif l_cmd1 >= MESSAGE_TYPES['thermostat_temp_up'] and l_cmd1 <= MESSAGE_TYPES['thermostat_report']: # 0x6e _l_ret1 = Insteon_HVAC.ihvac_utility().decode_50_record(l_device_obj, l_cmd1, l_cmd2) pass elif l_cmd1 >= 0x68 and l_cmd1 <= 0x75: # 0x6e _l_ret1 = Insteon_HVAC.ihvac_utility().decode_50_record(l_device_obj, l_cmd1, l_cmd2) pass elif l_message[8] & 0xE0 == 0x80 and l_cmd1 == 01: l_debug_msg += ' Device Set Button Pressed ' elif l_message[8] & 0xE0 == 0x80 and l_cmd1 == 02: l_debug_msg += ' Controller Set Button Pressed ' else: l_debug_msg += "\n\tUnknown type - last command was {} - {}; ".format(l_device_obj._Command1, PrintBytes(l_message)) LOG.warn('Decoding 50 tyoe {}'.format(l_debug_msg)) except AttributeError as e_err: LOG.error('ERROR decoding 50 record {}'.format(e_err)) l_ret = True LOG.info('50 Resp; {}'.format(l_debug_msg)) return self.check_for_more_decoding(p_controller_obj, l_ret)
def _decode_50_record(self, p_controller_obj): """ Insteon Standard Message Received (11 bytes) A Standard-length INSTEON message is received from either a Controller or Responder that you are ALL-Linked to. See p 233(246) of developers guide. [0] = x02 [1] = 0x50 [2-4] = from address [5-7] = to address / group [8] = message flags [9] = command 1 [10] = command 2 """ l_message = p_controller_obj._Message l_device_obj = utilDecode.get_obj_from_message(self.m_pyhouse_obj, l_message[2:5]) l_flags = utilDecode._decode_message_flag(l_message[8]) l_cmd1 = l_message[9] l_cmd2 = l_message[10] l_data = [l_cmd1, l_cmd2] # print(PrettyFormatAny.form(l_device_obj, 'Insteon_decoder 156 - Device')) if l_device_obj.DeviceType == 2: Insteon_HVAC.ihvac_utility().decode_50_record( self.m_pyhouse_obj, l_device_obj, p_controller_obj) return self.check_for_more_decoding(p_controller_obj, True) l_debug_msg = 'Std Msg fm: {}; Cmd1:{:#x}, Cmd2:{:#x}; '.format( l_device_obj.Name, l_cmd1, l_cmd2) # Break down bits 7(msb), 6, 5 into message type if l_message[8] & 0xE0 == 0x80: # Broadcast/NAK Message (100) l_debug_msg += utilDecode._devcat(l_message[5:7], l_device_obj) elif l_message[ 8] & 0xE0 == 0xC0: # (110) all link broadcast of group id l_group = l_message[7] l_debug_msg += "All-Link broadcast - Group:{}, Data:{}; ".format( l_group, l_data) LOG.info("== 50B All-link Broadcast Group:{}, Data:{} ==".format( l_group, l_data)) # try: if l_cmd1 == MESSAGE_TYPES['product_data_request']: # 0x03 l_debug_msg += " product data request. - Should never happen - S/B 51 response" elif l_cmd1 == MESSAGE_TYPES['engine_version']: # 0x0D l_engine_id = l_cmd2 l_device_obj.EngineVersion = l_engine_id l_debug_msg += "Engine version is: {}; ".format(l_engine_id) self._publish(self.m_pyhouse_obj, l_device_obj) elif l_cmd1 == MESSAGE_TYPES['id_request']: # 0x10 l_debug_msg += "Request ID From: {}; ".format( l_device_obj.Name) # LOG.info("Got an ID request. Light:{}".format(l_device_obj.Name,)) elif l_cmd1 == MESSAGE_TYPES['on']: # 0x11 l_device_obj.CurLevel = 100 l_debug_msg += "Device:{} turned Full ON ; ".format( l_device_obj.Name) self._publish(self.m_pyhouse_obj, l_device_obj) elif l_cmd1 == MESSAGE_TYPES['off']: # 0x13 l_device_obj.CurLevel = 0 l_debug_msg += "Light:{} turned Full OFF; ".format( l_device_obj.Name) self._publish(self.m_pyhouse_obj, l_device_obj) elif l_cmd1 == MESSAGE_TYPES['status_request']: # 0x19 l_level = int(((l_cmd2 + 2) * 100) / 256) l_device_obj.CurLevel = l_level l_debug_msg += "Status of light:{} is level:{}; ".format( l_device_obj.Name, l_level) LOG.info( "PLM:{} Got Light Status From:{}, Level is:{} ".format( p_controller_obj.Name, l_device_obj.Name, l_level)) elif l_cmd1 >= MESSAGE_TYPES[ 'thermostat_temp_up'] and l_cmd1 <= MESSAGE_TYPES[ 'thermostat_report']: # 0x6e _l_ret1 = Insteon_HVAC.ihvac_utility().decode_50_record( l_device_obj, l_cmd1, l_cmd2) pass elif l_cmd1 >= 0x68 and l_cmd1 <= 0x75: # 0x6e _l_ret1 = Insteon_HVAC.ihvac_utility().decode_50_record( l_device_obj, l_cmd1, l_cmd2) pass elif l_message[8] & 0xE0 == 0x80 and l_cmd1 == 01: l_debug_msg += ' Device Set Button Pressed ' elif l_message[8] & 0xE0 == 0x80 and l_cmd1 == 02: l_debug_msg += ' Controller Set Button Pressed ' else: l_debug_msg += "\n\tUnknown type - last command was {} - {}; ".format( l_device_obj._Command1, PrintBytes(l_message)) LOG.warn('Decoding 50 tyoe {}'.format(l_debug_msg)) except AttributeError as e_err: LOG.error('ERROR decoding 50 record {}'.format(e_err)) l_ret = True LOG.info('50 Resp; {}'.format(l_debug_msg)) return self.check_for_more_decoding(p_controller_obj, l_ret)