Ejemplo n.º 1
0
def phy2phy_SRIOV_FourOvs(cnx_server, isDPDK, nbrCores, isIsolated):
    cpuArray = exp.cpuAllocation(4, nbrCores, isIsolated, True, totalTenantVMs,
                                 TenantVmCores, totalCpuCores)
    exp.HOST_CPU = cpuArray["hostCpu"]
    OvsCpu = cpuArray["ovsCpu"]
    DpdkCpu = cpuArray["ovsDpdk"]
    cpuDpdkPorts = cpuArray["cpuDpdkPorts"]
    OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"]

    exp.NicConfig = ["1", "12"]
    exp.NicType = "mlx"
    exp.isSRIOV = True
    exp.Server_cnx = cnx_server

    exp.pf_index = 0
    exp.pfs = []
    exp.vfs = []

    exp.scsName = "phy2phy_SRIOV_FourOvs_IsDPDK=" + str(
        isDPDK) + "_IsIsolated=" + str(isIsolated)
    logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S")

    exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp)
    exp.Logs("", logTimeStamp)

    if isDPDK:
        exp.IsDPDK = True
        exp.OVS_PATH = exp.dpdk_path
    else:
        exp.IsDPDK = False
        exp.OVS_PATH = exp.nodpdk_path

    exp.PhyPorts = [("enp2s0f0", "12"), ("enp2s0f1", "12")]

    exp.InitialConfig()
    port_1_Vfs = exp.pfs[0][2]
    port_2_Vfs = exp.pfs[1][2]

    exp.MyVfs = [(port_1_Vfs[0], "0", "off", "vswitch-vm"),
                 (port_2_Vfs[0], "0", "off", "vswitch-vm"),
                 (port_1_Vfs[3], "0", "off", "vswitch-vm-2"),
                 (port_2_Vfs[3], "0", "off", "vswitch-vm-2"),
                 (port_1_Vfs[6], "0", "off", "vswitch-vm-3"),
                 (port_2_Vfs[6], "0", "off", "vswitch-vm-3"),
                 (port_1_Vfs[9], "0", "off", "vswitch-vm-4"),
                 (port_2_Vfs[9], "0", "off", "vswitch-vm-4")]

    exp.usedVms = [("vswitch-vm", OvsVMsCpuArray[0], VmRam),
                   ("vswitch-vm-2", OvsVMsCpuArray[1], VmRam),
                   ("vswitch-vm-3", OvsVMsCpuArray[2], VmRam),
                   ("vswitch-vm-4", OvsVMsCpuArray[3], VmRam)]

    if isDPDK:
        OvsVmPorts1 = [(port_1_Vfs[0], True, cpuDpdkPorts),
                       (port_2_Vfs[0], True, cpuDpdkPorts)]

        OvsVmPorts2 = [(port_1_Vfs[3], True, cpuDpdkPorts),
                       (port_2_Vfs[3], True, cpuDpdkPorts)]

        OvsVmPorts3 = [(port_1_Vfs[6], True, cpuDpdkPorts),
                       (port_2_Vfs[6], True, cpuDpdkPorts)]

        OvsVmPorts4 = [(port_1_Vfs[9], True, cpuDpdkPorts),
                       (port_2_Vfs[9], True, cpuDpdkPorts)]
    else:
        OvsVmPorts1 = [(port_1_Vfs[0], False), (port_2_Vfs[0], False)]

        OvsVmPorts2 = [(port_1_Vfs[3], False), (port_2_Vfs[3], False)]

        OvsVmPorts3 = [(port_1_Vfs[6], False), (port_2_Vfs[6], False)]

        OvsVmPorts4 = [(port_1_Vfs[9], False), (port_2_Vfs[9], False)]

    msg = exp.GetScenarioSummary(
        [OvsVmPorts1, OvsVmPorts2, OvsVmPorts3, OvsVmPorts4], OvsCpu, DpdkCpu,
        DpdkMem, isIsolated)
    exp.EmailNotify(msg, "is beeing prepared", logTimeStamp)
    exp.Logs(msg, logTimeStamp)
    exp.Vfsconfig()

    if isDPDK:
        exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu, DpdkMem,
                      DpdkCpu)
        exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu, DpdkMem,
                      DpdkCpu)
        exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu, DpdkMem,
                      DpdkCpu)
        exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu, DpdkMem,
                      DpdkCpu)
    else:
        exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu)
        exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu)
        exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu)
        exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu)
    '''
    OVS Flow Rules for OVS-VM-1:
    
    Note that the VF offset (3) is chosen to be unnecessarily big in order to 
    match in/out port assignment between p2p and p2v for the same number of OvS VMs/instances 
    (same offsets -> same MACs -> same pcaps can be used for measurements) 
    
    '''

    #Flow Rules (1)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.2"
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]]
    exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm", exp.OVS_PATH, "br0")
    '''
    OVS Flow Rules for OVS-VM-2:
    '''
    #Flow Rules (3)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[3]] + ",ip,nw_dst=10.0.0.3"
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[3]]
    exp.addFlowRule("vswitch-vm-2", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm-2", exp.OVS_PATH, "br0")
    '''
    OVS Flow Rules for OVS-VM-3:
    '''
    #Flow Rules (1)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[6]] + ",ip,nw_dst=10.0.0.4"
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[6]]
    exp.addFlowRule("vswitch-vm-3", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm-3", exp.OVS_PATH, "br0")
    '''
    OVS Flow Rules for OVS-VM-4:
    '''

    #Flow Rules (3)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[9]] + ",ip,nw_dst=10.0.0.5"
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[9]]
    exp.addFlowRule("vswitch-vm-4", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm-4", exp.OVS_PATH, "br0")

    exp.EmailNotify(msg, "is ready", logTimeStamp)

    return True
Ejemplo n.º 2
0
def phy2vm2vm2phy_SRIOV_FourOvs(cnx_server, isDPDK, nbrCores, isIsolated):
    cpuArray = exp.cpuAllocation(4, nbrCores, isIsolated, True, totalTenantVMs,
                                 TenantVmCores, totalCpuCores)
    exp.HOST_CPU = cpuArray["hostCpu"]
    OvsCpu = cpuArray["ovsCpu"]
    DpdkCpu = cpuArray["ovsDpdk"]
    cpuDpdkPorts = cpuArray["cpuDpdkPorts"]
    TenantVMsCpuArray = cpuArray["TenantVMsCpuArray"]
    OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"]

    exp.NicConfig = ["1", "12"]
    exp.NicType = "mlx"
    exp.isSRIOV = True
    exp.Server_cnx = cnx_server

    exp.pf_index = 0
    exp.pfs = []
    exp.vfs = []

    exp.scsName = "phy2vm2vm2phy_SRIOV_FourOvs_IsDPDK=" + str(
        isDPDK) + "_IsIsolated=" + str(isIsolated)
    logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S")

    exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp)
    exp.Logs("", logTimeStamp)

    if isDPDK:
        exp.IsDPDK = True
        exp.OVS_PATH = exp.dpdk_path
    else:
        exp.IsDPDK = False
        exp.OVS_PATH = exp.nodpdk_path

    exp.PhyPorts = [("enp2s0f0", "12"), ("enp2s0f1", "12")]

    exp.InitialConfig()
    port_1_Vfs = exp.pfs[0][2]
    port_2_Vfs = exp.pfs[1][2]

    exp.MyVfs = [(port_1_Vfs[0], "0", "off", "vswitch-vm"),
                 (port_2_Vfs[0], "0", "off", "vswitch-vm"),
                 (port_1_Vfs[1], "10", "off", "vswitch-vm"),
                 (port_2_Vfs[1], "10", "off", "vswitch-vm"),
                 (port_1_Vfs[2], "10", "off", "tenant-green-1"),
                 (port_2_Vfs[2], "10", "off", "tenant-green-1"),
                 (port_1_Vfs[3], "0", "off", "vswitch-vm-2"),
                 (port_2_Vfs[3], "0", "off", "vswitch-vm-2"),
                 (port_1_Vfs[4], "20", "off", "vswitch-vm-2"),
                 (port_2_Vfs[4], "20", "off", "vswitch-vm-2"),
                 (port_1_Vfs[5], "20", "off", "tenant-green-2"),
                 (port_2_Vfs[5], "20", "off", "tenant-green-2"),
                 (port_1_Vfs[6], "0", "off", "vswitch-vm-3"),
                 (port_2_Vfs[6], "0", "off", "vswitch-vm-3"),
                 (port_1_Vfs[7], "30", "off", "vswitch-vm-3"),
                 (port_2_Vfs[7], "30", "off", "vswitch-vm-3"),
                 (port_1_Vfs[8], "30", "off", "tenant-green-3"),
                 (port_2_Vfs[8], "30", "off", "tenant-green-3"),
                 (port_1_Vfs[9], "0", "off", "vswitch-vm-4"),
                 (port_2_Vfs[9], "0", "off", "vswitch-vm-4"),
                 (port_1_Vfs[10], "40", "off", "vswitch-vm-4"),
                 (port_2_Vfs[10], "40", "off", "vswitch-vm-4"),
                 (port_1_Vfs[11], "40", "off", "tenant-green-4"),
                 (port_2_Vfs[11], "40", "off", "tenant-green-4")]

    exp.usedVms = [("vswitch-vm", OvsVMsCpuArray[0], VmRam),
                   ("vswitch-vm-2", OvsVMsCpuArray[1], VmRam),
                   ("vswitch-vm-3", OvsVMsCpuArray[2], VmRam),
                   ("vswitch-vm-4", OvsVMsCpuArray[3], VmRam),
                   ("tenant-green-1", TenantVMsCpuArray[0], VmRam),
                   ("tenant-green-2", TenantVMsCpuArray[1], VmRam),
                   ("tenant-green-3", TenantVMsCpuArray[2], VmRam),
                   ("tenant-green-4", TenantVMsCpuArray[3], VmRam)]

    if isDPDK:
        OvsVmPorts1 = [(port_1_Vfs[0], True, cpuDpdkPorts),
                       (port_2_Vfs[0], True, cpuDpdkPorts),
                       (port_1_Vfs[1], True, cpuDpdkPorts),
                       (port_2_Vfs[1], True, cpuDpdkPorts)]

        OvsVmPorts2 = [(port_1_Vfs[3], True, cpuDpdkPorts),
                       (port_2_Vfs[3], True, cpuDpdkPorts),
                       (port_1_Vfs[4], True, cpuDpdkPorts),
                       (port_2_Vfs[4], True, cpuDpdkPorts)]

        OvsVmPorts3 = [(port_1_Vfs[6], True, cpuDpdkPorts),
                       (port_2_Vfs[6], True, cpuDpdkPorts),
                       (port_1_Vfs[7], True, cpuDpdkPorts),
                       (port_2_Vfs[7], True, cpuDpdkPorts)]

        OvsVmPorts4 = [(port_1_Vfs[9], True, cpuDpdkPorts),
                       (port_2_Vfs[9], True, cpuDpdkPorts),
                       (port_1_Vfs[10], True, cpuDpdkPorts),
                       (port_2_Vfs[10], True, cpuDpdkPorts)]
    else:
        OvsVmPorts1 = [(port_1_Vfs[0], False), (port_2_Vfs[0], False),
                       (port_1_Vfs[1], False), (port_2_Vfs[1], False)]

        OvsVmPorts2 = [(port_1_Vfs[3], False), (port_2_Vfs[3], False),
                       (port_1_Vfs[4], False), (port_2_Vfs[4], False)]

        OvsVmPorts3 = [(port_1_Vfs[6], False), (port_2_Vfs[6], False),
                       (port_1_Vfs[7], False), (port_2_Vfs[7], False)]

        OvsVmPorts4 = [(port_1_Vfs[9], False), (port_2_Vfs[9], False),
                       (port_1_Vfs[10], False), (port_2_Vfs[10], False)]

    msg = exp.GetScenarioSummary(
        [OvsVmPorts1, OvsVmPorts2, OvsVmPorts3, OvsVmPorts4], OvsCpu, DpdkCpu,
        DpdkMem, isIsolated)
    exp.EmailNotify(msg, "is beeing prepared", logTimeStamp)
    exp.Logs(msg, logTimeStamp)
    exp.Vfsconfig()

    if isDPDK:
        exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu, DpdkMem,
                      DpdkCpu)
        exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu, DpdkMem,
                      DpdkCpu)
        exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu, DpdkMem,
                      DpdkCpu)
        exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu, DpdkMem,
                      DpdkCpu)
    else:
        exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu)
        exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu)
        exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu)
        exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu)
    '''
    OVS Flow Rules for OVS-VM-1:
    '''
    # Flow Rules (1)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.2"
    action = "mod_dl_dst:" + exp.GetMacByVf(
        port_1_Vfs[2]) + "," + exp.VfsMatch[port_1_Vfs[1]]
    exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action)

    # Flow Rules (2)
    match = "in_port=" + exp.VfsMatch[port_2_Vfs[1]]
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]]
    exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm", exp.OVS_PATH, "br0")
    '''
    OVS Flow Rules for OVS-VM-2:
    '''
    #Flow Rules (3)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[3]] + ",ip,nw_dst=10.0.0.3"
    action = "mod_dl_dst:" + exp.GetMacByVf(
        port_1_Vfs[5]) + "," + exp.VfsMatch[port_1_Vfs[4]]
    exp.addFlowRule("vswitch-vm-2", exp.OVS_PATH, "br0", match, action)

    #Flow Rules (4)
    match = "in_port=" + exp.VfsMatch[port_2_Vfs[4]]
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[3]]
    exp.addFlowRule("vswitch-vm-2", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm-2", exp.OVS_PATH, "br0")
    '''
    OVS Flow Rules for OVS-VM-3:
    '''
    #Flow Rules (1)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[6]] + ",ip,nw_dst=10.0.0.4"
    action = "mod_dl_dst:" + exp.GetMacByVf(
        port_1_Vfs[8]) + "," + exp.VfsMatch[port_1_Vfs[7]]
    exp.addFlowRule("vswitch-vm-3", exp.OVS_PATH, "br0", match, action)

    #Flow Rules (2)
    match = "in_port=" + exp.VfsMatch[port_2_Vfs[7]]
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[6]]
    exp.addFlowRule("vswitch-vm-3", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm-3", exp.OVS_PATH, "br0")
    '''
    OVS Flow Rules for OVS-VM-4:
    '''

    #Flow Rules (3)
    match = "in_port=" + exp.VfsMatch[port_1_Vfs[9]] + ",ip,nw_dst=10.0.0.5"
    action = "mod_dl_dst:" + exp.GetMacByVf(
        port_1_Vfs[11]) + "," + exp.VfsMatch[port_1_Vfs[10]]
    exp.addFlowRule("vswitch-vm-4", exp.OVS_PATH, "br0", match, action)

    #Flow Rules (4)
    match = "in_port=" + exp.VfsMatch[port_2_Vfs[10]]
    action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[9]]
    exp.addFlowRule("vswitch-vm-4", exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules("vswitch-vm-4", exp.OVS_PATH, "br0")

    exp.startL2Frwd(4)

    exp.EmailNotify(msg, "is ready", logTimeStamp)

    return True
Ejemplo n.º 3
0
def phy2phy_Baseline(cnx_server, isDPDK, nbrCores):
    cpuArray = exp.cpuAllocation(1, nbrCores, True, False, totalTenantVMs,
                                 TenantVmCores, totalCpuCores)
    exp.HOST_CPU = cpuArray["hostCpu"]
    OvsCpu = cpuArray["ovsCpu"]
    DpdkCpu = cpuArray["ovsDpdk"]
    cpuDpdkPorts = cpuArray["cpuDpdkPorts"]
    DpdkMem = str(
        (nbrCores - 1) *
        1024)  # for multiple cores need to allocate proportional memory

    exp.NicType = "mlx"
    exp.isSRIOV = False
    exp.Server_cnx = cnx_server

    exp.scsName = "phy2phy_Baseline" + "_IsDPDK=" + str(isDPDK)
    logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S")

    if isDPDK:
        exp.IsDPDK = True
        exp.OVS_PATH = exp.dpdk_path
    else:
        exp.IsDPDK = False
        exp.OVS_PATH = exp.nodpdk_path

    if isDPDK:
        exp.PhyPorts = [("enp2s0f0", "br0", True, cpuDpdkPorts),
                        ("enp2s0f1", "br0", True, cpuDpdkPorts)]
    else:
        exp.PhyPorts = [("enp2s0f0", "br0"), ("enp2s0f1", "br0")]

    msg = exp.GetScenarioSummary([], OvsCpu, DpdkCpu, DpdkMem)
    exp.EmailNotify(msg, "is beeing prepared", logTimeStamp)
    exp.Logs(msg, logTimeStamp)
    exp.InitialConfig(isDPDK)

    if isDPDK:
        exp.ConfigOVS(exp.Server_cnx, "br0", " ", OvsCpu, DpdkMem, DpdkCpu)
    else:
        exp.ConfigOVS(exp.Server_cnx, "br0", " ", OvsCpu)

    exp.VirPortConfig()
    '''
    OVS Flow Rules:

    '''
    # Flow Rules (1)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.2"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (2)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.3"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (3)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.4"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (4)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.5"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    exp.showFlowRules(exp.Server_cnx, exp.OVS_PATH, "br0")

    exp.EmailNotify(msg, "is ready", logTimeStamp)

    return True
Ejemplo n.º 4
0
def phy2vm2vm2phy_Baseline(cnx_server, isDPDK, nbrCores):
    cpuArray = exp.cpuAllocation(1, nbrCores, True, False, totalTenantVMs,
                                 TenantVmCores, totalCpuCores)
    exp.HOST_CPU = cpuArray["hostCpu"]
    OvsCpu = cpuArray["ovsCpu"]
    DpdkCpu = cpuArray["ovsDpdk"]
    cpuDpdkPorts = cpuArray["cpuDpdkPorts"]
    TenantVMsCpuArray = cpuArray["TenantVMsCpuArray"]

    exp.NicType = "mlx"
    exp.isSRIOV = False
    exp.Server_cnx = cnx_server

    exp.scsName = "phy2vm2vm2phy_Baseline" + "_IsDPDK=" + str(isDPDK)
    logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S")

    if isDPDK:
        exp.IsDPDK = True
        exp.OVS_PATH = exp.dpdk_path
    else:
        exp.IsDPDK = False
        exp.OVS_PATH = exp.nodpdk_path

    exp.VirtualPorts = [("1", "br0", "tenant-green-1"),
                        ("2", "br0", "tenant-green-1"),
                        ("4", "br0", "tenant-green-2"),
                        ("5", "br0", "tenant-green-2"),
                        ("7", "br0", "tenant-green-3"),
                        ("8", "br0", "tenant-green-3"),
                        ("10", "br0", "tenant-green-4"),
                        ("11", "br0", "tenant-green-4")]

    exp.usedVms = [("tenant-green-1", TenantVMsCpuArray[0], VmRam),
                   ("tenant-green-2", TenantVMsCpuArray[1], VmRam),
                   ("tenant-green-3", TenantVMsCpuArray[2], VmRam),
                   ("tenant-green-4", TenantVMsCpuArray[3], VmRam)]

    if isDPDK:
        exp.PhyPorts = [("enp2s0f0", "br0", True, cpuDpdkPorts),
                        ("enp2s0f1", "br0", True, cpuDpdkPorts)]
    else:
        exp.PhyPorts = [("enp2s0f0", "br0"), ("enp2s0f1", "br0")]

    msg = exp.GetScenarioSummary([], OvsCpu, DpdkCpu, DpdkMem)
    exp.EmailNotify(msg, "is beeing prepared", logTimeStamp)
    exp.Logs(msg, logTimeStamp)

    exp.InitialConfig(isDPDK)

    if isDPDK:
        exp.ConfigOVS(exp.Server_cnx, "br0", " ", OvsCpu, DpdkMem, DpdkCpu)
    else:
        exp.ConfigOVS(exp.Server_cnx, "br0", " ", OvsCpu)

    exp.VirPortConfig()
    '''
    OVS Flow Rules:

    '''
    # Flow Rules (1)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.2"
    action = "vnet1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (2)
    match = "in_port=vnet2"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (3)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.3"
    action = "vnet4"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (4)
    match = "in_port=vnet5"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (1)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.4"
    action = "vnet7"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (2)
    match = "in_port=vnet8"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (1)
    match = "in_port=enp2s0f0,ip,nw_dst=10.0.0.5"
    action = "vnet10"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # Flow Rules (2)
    match = "in_port=vnet11"
    action = "enp2s0f1"
    exp.addFlowRule(exp.Server_cnx, exp.OVS_PATH, "br0", match, action)

    # show Flow rules of br0
    exp.showFlowRules(exp.Server_cnx, exp.OVS_PATH, "br0")

    exp.startL2Frwd(nbrOvs=1,
                    nicType="e1000",
                    tenantCount=4,
                    vswitchMode="Baseline_4Tenants")
    exp.SetBridging("tenant-green-1", exp.VirPortsMatch["1"],
                    exp.VirPortsMatch["2"])
    exp.SetBridging("tenant-green-2", exp.VirPortsMatch["4"],
                    exp.VirPortsMatch["5"])
    exp.SetBridging("tenant-green-3", exp.VirPortsMatch["7"],
                    exp.VirPortsMatch["8"])
    exp.SetBridging("tenant-green-4", exp.VirPortsMatch["10"],
                    exp.VirPortsMatch["11"])
    exp.EmailNotify(msg, "is ready", logTimeStamp)

    return True