def _init_ppc(net, v_start, delta_start, calculate_voltage_angles):
    # initialize ppc voltages
    net.res_bus.vm_pu = v_start
    net.res_bus.vm_pu[net.bus.index[net.bus.in_service == False]] = np.nan
    net.res_bus.va_degree = delta_start
    # select elements in service and convert pandapower ppc to ppc
    net._options = {}
    _add_ppc_options(net,
                     check_connectivity=False,
                     init_vm_pu="results",
                     init_va_degree="results",
                     trafo_model="t",
                     copy_constraints_to_ppc=False,
                     mode="pf",
                     enforce_q_lims=False,
                     calculate_voltage_angles=calculate_voltage_angles,
                     r_switch=0.0,
                     recycle=dict(_is_elements=False, ppc=False, Ybus=False))
    net["_is_elements"] = _select_is_elements_numba(net)
    ppc, ppci = _pd2ppc(net)

    # do dc power flow for phase shifting transformers
    if np.any(net.trafo.shift_degree):
        vm_backup = ppci["bus"][:, 7].copy()
        ppci["bus"][:, [2, 3]] = 0.
        ppci = _run_dc_pf(ppci)
        ppci["bus"][:, 7] = vm_backup

    return ppc, ppci
Ejemplo n.º 2
0
def _pd2ppc_zero(net):
    """
    Builds the ppc data structure for zero impedance system. Includes the impedance values of
    lines and transformers, but no load or generation data.

    For short-circuit calculation, the short-circuit impedance of external grids is also considered.
    """
    # select elements in service (time consuming, so we do it once)
    net["_is_elements"] = aux._select_is_elements_numba(net)

    ppc = _init_ppc(net)
    # init empty ppci
    ppci = copy.deepcopy(ppc)
    _build_bus_ppc(net, ppc)
    _build_gen_ppc(net, ppc)
    _add_ext_grid_sc_impedance_zero(net, ppc)
    _build_branch_ppc_zero(net, ppc)

    # adds auxilary buses for open switches at branches
    _switch_branches(net, ppc)

    # add auxilary buses for out of service buses at in service lines.
    # Also sets lines out of service if they are connected to two out of service buses
    _branches_with_oos_buses(net, ppc)
    if hasattr(net, "_isolated_buses"):
        ppc["bus"][net._isolated_buses, 1] = 4.
    # generates "internal" ppci format (for powerflow calc) from "external" ppc format and updates the bus lookup
    # Note: Also reorders buses and gens in ppc
    ppci = _ppc2ppci(ppc, ppci, net)
    net._ppc0 = ppc
    return ppc, ppci
Ejemplo n.º 3
0
def _init_ppc(net, v_start, delta_start, calculate_voltage_angles):
    # select elements in service and convert pandapower ppc to ppc
    net._options = {}
    _add_ppc_options(net,
                     check_connectivity=False,
                     init_vm_pu=v_start,
                     init_va_degree=delta_start,
                     trafo_model="pi",
                     mode="pf",
                     enforce_q_lims=False,
                     calculate_voltage_angles=calculate_voltage_angles,
                     switch_rx_ratio=2,
                     recycle=dict(_is_elements=False, ppc=False, Ybus=False))
    net["_is_elements"] = _select_is_elements_numba(net)
    _add_auxiliary_elements(net)
    ppc, ppci = _pd2ppc(net)

    # do dc power flow for phase shifting transformers
    if np.any(net.trafo.shift_degree):
        vm_backup = ppci["bus"][:, 7].copy()
        ppci["bus"][:, [2, 3]] = 0.
        ppci = _run_dc_pf(ppci)
        ppci["bus"][:, 7] = vm_backup

    return ppc, ppci
Ejemplo n.º 4
0
def _update_ppc(net):
    """
    Updates P, Q values of the ppc with changed values from net

    @param _is_elements:
    @return:
    """
    # select elements in service (time consuming, so we do it once)
    net["_is_elements"] = aux._select_is_elements_numba(net)

    recycle = net["_options"]["recycle"]
    # get the old ppc and lookup
    ppc = net["_ppc"]
    ppci = copy.deepcopy(ppc)
    # adds P and Q for loads / sgens in ppc['bus'] (PQ nodes)
    _calc_pq_elements_and_add_on_ppc(net, ppc)
    # adds P and Q for shunts, wards and xwards (to PQ nodes)
    _calc_shunts_and_add_on_ppc(net, ppc)
    # updates values for gen
    _update_gen_ppc(net, ppc)
    # check if any generators connected to the same bus have different voltage setpoints
    _check_voltage_setpoints_at_same_bus(ppc)

    if not recycle["Ybus"]:
        # updates trafo and trafo3w values
        _update_trafo_trafo3w_ppc(net, ppc)

    # get OOS buses and place them at the end of the bus array (so that: 3
    # (REF), 2 (PV), 1 (PQ), 4 (OOS))
    oos_busses = ppc['bus'][:, BUS_TYPE] == NONE
    # there are no OOS busses in the ppci
    ppci['bus'] = ppc['bus'][~oos_busses]
    # select in service elements from ppc and put them in ppci
    brs = ppc["internal"]["branch_is"]
    gs = ppc["internal"]["gen_is"]
    ppci["branch"] = ppc["branch"][brs]
    ppci["gen"] = ppc["gen"][gs]

    return ppc, ppci
Ejemplo n.º 5
0
def _pd2ppc(net, sequence=None):
    """
    Converter Flow:
        1. Create an empty pypower datatructure
        2. Calculate loads and write the bus matrix
        3. Build the gen (Infeeder)- Matrix
        4. Calculate the line parameter and the transformer parameter,
           and fill it in the branch matrix.
           Order: 1st: Line values, 2nd: Trafo values
        5. if opf: make opf objective (gencost)
        6. convert internal ppci format for pypower powerflow / 
        opf without out of service elements and rearanged buses

    INPUT:
        **net** - The pandapower format network
        **sequence** - Used for three phase analysis
        ( 0 - Zero Sequence
          1 - Positive Sequence
          2 - Negative Sequence
        ) 

    OUTPUT:
        **ppc** - The simple matpower format network. Which consists of:
                  ppc = {
                        "baseMVA": 1., *float*
                        "version": 2,  *int*
                        "bus": np.array([], dtype=float),
                        "branch": np.array([], dtype=np.complex128),
                        "gen": np.array([], dtype=float),
                        "gencost" =  np.array([], dtype=float), only for OPF
                        "internal": {
                              "Ybus": np.array([], dtype=np.complex128)
                              , "Yf": np.array([], dtype=np.complex128)
                              , "Yt": np.array([], dtype=np.complex128)
                              , "branch_is": np.array([], dtype=bool)
                              , "gen_is": np.array([], dtype=bool)
                              }
        **ppci** - The "internal" pypower format network for PF calculations
        
    """
    # select elements in service (time consuming, so we do it once)
    net["_is_elements"] = aux._select_is_elements_numba(net, sequence=sequence)

    # Gets network configurations
    mode = net["_options"]["mode"]
    check_connectivity = net["_options"]["check_connectivity"]
    calculate_voltage_angles = net["_options"]["calculate_voltage_angles"]

    ppc = _init_ppc(net, mode=mode, sequence=sequence)

    # generate ppc['bus'] and the bus lookup
    _build_bus_ppc(net, ppc)
    if sequence == 0:
        from pandapower.pd2ppc_zero import _add_ext_grid_sc_impedance_zero, _build_branch_ppc_zero
        # Adds external grid impedance for 3ph and sc calculations in ppc0
        _add_ext_grid_sc_impedance_zero(net, ppc)
        # Calculates ppc0 branch impedances from branch elements
        _build_branch_ppc_zero(net, ppc)
    else:
        # Calculates ppc1/ppc2 branch impedances from branch elements
        _build_branch_ppc(net, ppc)

    # Adds P and Q for loads / sgens in ppc['bus'] (PQ nodes)
    if mode == "sc":
        _add_gen_impedances_ppc(net, ppc)
        _add_motor_impedances_ppc(net, ppc)
    else:
        _calc_pq_elements_and_add_on_ppc(net, ppc, sequence=sequence)
        # adds P and Q for shunts, wards and xwards (to PQ nodes)
        _calc_shunts_and_add_on_ppc(net, ppc)

    # adds auxilary buses for open switches at branches
    _switch_branches(net, ppc)

    # Adds auxilary buses for in service lines with out of service buses.
    # Also deactivates lines if they are connected to two out of service buses
    _branches_with_oos_buses(net, ppc)

    if check_connectivity:
        if sequence in [None, 1, 2]:
            # sets islands (multiple isolated nodes) out of service
            if "opf" in mode:
                net["_isolated_buses"], _, _ = aux._check_connectivity_opf(ppc)
            else:
                net["_isolated_buses"], _, _ = aux._check_connectivity(ppc)
            net["_is_elements_final"] = aux._select_is_elements_numba(
                net, net._isolated_buses, sequence)
        else:
            ppc["bus"][net._isolated_buses, BUS_TYPE] = NONE
        net["_is_elements"] = net["_is_elements_final"]
    else:
        # sets buses out of service, which aren't connected to branches / REF buses
        aux._set_isolated_buses_out_of_service(net, ppc)

    _build_gen_ppc(net, ppc)

    if "pf" in mode:
        _check_for_reference_bus(ppc)

    aux._replace_nans_with_default_limits(net, ppc)

    # generates "internal" ppci format (for powerflow calc)
    # from "external" ppc format and updates the bus lookup
    # Note: Also reorders buses and gens in ppc
    ppci = _ppc2ppci(ppc, net)

    if mode == "pf":
        # check if any generators connected to the same bus have different voltage setpoints
        _check_voltage_setpoints_at_same_bus(ppc)
        if calculate_voltage_angles:
            _check_voltage_angles_at_same_bus(net, ppci)

    if mode == "opf":
        # make opf objective
        ppci = _make_objective(ppci, net)

    return ppc, ppci
Ejemplo n.º 6
0
def _pd2ppc(net):
    """
    Converter Flow:
        1. Create an empty pypower datatructure
        2. Calculate loads and write the bus matrix
        3. Build the gen (Infeeder)- Matrix
        4. Calculate the line parameter and the transformer parameter,
           and fill it in the branch matrix.
           Order: 1st: Line values, 2nd: Trafo values
        5. if opf: make opf objective (gencost)
        6. convert internal ppci format for pypower powerflow / opf without out of service elements and rearanged buses

    INPUT:
        **net** - The pandapower format network

    OUTPUT:
        **ppc** - The simple matpower format network. Which consists of:
                  ppc = {
                        "baseMVA": 1., *float*
                        "version": 2,  *int*
                        "bus": np.array([], dtype=float),
                        "branch": np.array([], dtype=np.complex128),
                        "gen": np.array([], dtype=float),
                        "gencost" =  np.array([], dtype=float), only for OPF
                        "internal": {
                              "Ybus": np.array([], dtype=np.complex128)
                              , "Yf": np.array([], dtype=np.complex128)
                              , "Yt": np.array([], dtype=np.complex128)
                              , "branch_is": np.array([], dtype=bool)
                              , "gen_is": np.array([], dtype=bool)
                              }
        **ppci** - The "internal" pypower format network for PF calculations
    """
    # select elements in service (time consuming, so we do it once)
    use_numba = ("numba" in net["_options"] and net["_options"]["numba"] and
                 (net["_options"]["recycle"] is None or
                  not net["_options"]["recycle"]["_is_elements"]))
    #use_numba = False
    if use_numba:
        net["_is_elements"] = aux._select_is_elements_numba(net)
    else:
        net["_is_elements"] = aux._select_is_elements(net)

    # get options
    mode = net["_options"]["mode"]
    check_connectivity = net["_options"]["check_connectivity"]

    ppc = _init_ppc(net)

    if mode == "opf":
        # additional fields in ppc
        ppc["gencost"] = np.array([], dtype=float)

    # init empty ppci
    ppci = copy.deepcopy(ppc)
    # generate ppc['bus'] and the bus lookup
    _build_bus_ppc(net, ppc)
    # generate ppc['gen'] and fills ppc['bus'] with generator values (PV, REF nodes)
    _build_gen_ppc(net, ppc)
    # generate ppc['branch'] and directly generates branch values
    _build_branch_ppc(net, ppc)
    # adds P and Q for loads / sgens in ppc['bus'] (PQ nodes)
    if mode == "sc":
        _add_gen_impedances_ppc(net, ppc)
        _add_motor_impedances_ppc(net, ppc)
    else:
        _calc_loads_and_add_on_ppc(net, ppc)
        # adds P and Q for shunts, wards and xwards (to PQ nodes)
        _calc_shunts_and_add_on_ppc(net, ppc)

    # adds auxilary buses for open switches at branches
    _switch_branches(net, ppc)

    # add auxilary buses for out of service buses at in service lines.
    # Also sets lines out of service if they are connected to two out of service buses
    _branches_with_oos_buses(net, ppc)

    # sets buses out of service, which aren't connected to branches / REF buses
    if check_connectivity:
        isolated_nodes, _, _ = aux._check_connectivity(ppc)
        if use_numba:
            net["_is_elements"] = aux._select_is_elements_numba(net, isolated_nodes)
        else:
            aux._create_ppc2pd_bus_lookup(net)
            aux._remove_isolated_elements_from_is_elements(net, isolated_nodes)
#             ToDo: The reverse lookup (ppc2pd) needs to be updated in ppc2ppci!
    else:
        aux._set_isolated_buses_out_of_service(net, ppc)

    # generates "internal" ppci format (for powerflow calc) from "external" ppc format and updates the bus lookup
    # Note: Also reorders buses and gens in ppc
    ppci = _ppc2ppci(ppc, ppci, net)

    if mode == "opf":
        # make opf objective
        ppci = _make_objective(ppci, net)

    return ppc, ppci
Ejemplo n.º 7
0
def _pd2ppc(net):
    """
    Converter Flow:
        1. Create an empty pypower datatructure
        2. Calculate loads and write the bus matrix
        3. Build the gen (Infeeder)- Matrix
        4. Calculate the line parameter and the transformer parameter,
           and fill it in the branch matrix.
           Order: 1st: Line values, 2nd: Trafo values
        5. if opf: make opf objective (gencost)
        6. convert internal ppci format for pypower powerflow / opf without out of service elements and rearanged buses

    INPUT:
        **net** - The pandapower format network

    OUTPUT:
        **ppc** - The simple matpower format network. Which consists of:
                  ppc = {
                        "baseMVA": 1., *float*
                        "version": 2,  *int*
                        "bus": np.array([], dtype=float),
                        "branch": np.array([], dtype=np.complex128),
                        "gen": np.array([], dtype=float),
                        "gencost" =  np.array([], dtype=float), only for OPF
                        "internal": {
                              "Ybus": np.array([], dtype=np.complex128)
                              , "Yf": np.array([], dtype=np.complex128)
                              , "Yt": np.array([], dtype=np.complex128)
                              , "branch_is": np.array([], dtype=bool)
                              , "gen_is": np.array([], dtype=bool)
                              }
        **ppci** - The "internal" pypower format network for PF calculations
    """
    # select elements in service (time consuming, so we do it once)
    net["_is_elements"] = aux._select_is_elements_numba(net)

    # get options
    mode = net["_options"]["mode"]
    check_connectivity = net["_options"]["check_connectivity"]
    calculate_voltage_angles = net["_options"]["calculate_voltage_angles"]

    ppc = _init_ppc(net, mode=mode)

    # generate ppc['bus'] and the bus lookup
    _build_bus_ppc(net, ppc)
    # generate ppc['branch'] and directly generates branch values
    _build_branch_ppc(net, ppc)
    # adds P and Q for loads / sgens in ppc['bus'] (PQ nodes)
    if mode == "sc":
        _add_gen_impedances_ppc(net, ppc)
        _add_motor_impedances_ppc(net, ppc)
    else:
        _calc_pq_elements_and_add_on_ppc(net, ppc)
        # adds P and Q for shunts, wards and xwards (to PQ nodes)
        _calc_shunts_and_add_on_ppc(net, ppc)

    # adds auxilary buses for open switches at branches
    _switch_branches(net, ppc)

    # add auxilary buses for out of service buses at in service lines.
    # Also sets lines out of service if they are connected to two out of service buses
    _branches_with_oos_buses(net, ppc)

    if check_connectivity:
        # sets islands (multiple isolated nodes) out of service
        if "opf" in mode:
            isolated_nodes, _, _ = aux._check_connectivity_opf(ppc)
        else:
            isolated_nodes, _, _ = aux._check_connectivity(ppc)
        net["_is_elements"] = aux._select_is_elements_numba(
            net, isolated_nodes)

    # sets buses out of service, which aren't connected to branches / REF buses
    aux._set_isolated_buses_out_of_service(net, ppc)

    _build_gen_ppc(net, ppc)

    if "pf" in mode:
        _check_for_reference_bus(ppc)

    aux._replace_nans_with_default_limits(net, ppc)

    # generates "internal" ppci format (for powerflow calc) from "external" ppc format and updates the bus lookup
    # Note: Also reorders buses and gens in ppc
    ppci = _ppc2ppci(ppc, net)

    if mode == "pf":
        # check if any generators connected to the same bus have different voltage setpoints
        _check_voltage_setpoints_at_same_bus(ppc)
        if calculate_voltage_angles:
            _check_voltage_angles_at_same_bus(net, ppci)

    if mode == "opf":
        # make opf objective
        ppci = _make_objective(ppci, net)

    return ppc, ppci