Example #1
0
def setup(instname=None,reload=False):
    """
    setup('mar')
    setup instrument reduction parameters from instname_parameter.xml file

    if the instrument has already been defined, does nothing unless
    reload = True is specified
    """

    global Reducer
    if instname == None :
        instname = config['default.instrument']


    if not (Reducer is None) :
        old_name=Reducer.prop_man.instr_name
        if  old_name.upper()[0:3] == instname.upper()[0:3] :
            if not reload :
               return  # has been already defined

    Reducer = DRC.setup_reducer(instname,reload)
Example #2
0
def setup(instname=None,reload=False):
    """
    setup('mar')
    setup instrument reduction parameters from instname_parameter.xml file

    if the instrument has already been defined, does nothing unless
    reload = True is specified
    """

    global Reducer
    if instname == None :
        instname = config['default.instrument']


    if not (Reducer is None) :
        old_name=Reducer.prop_man.instr_name;
        if  old_name.upper()[0:3] == instname.upper()[0:3] :
            if not reload :
               return  # has been already defined

    Reducer = DRC.setup_reducer(instname,reload)
Example #3
0
def setup(instname=None,reload=False):
    """
    setup('mar')
    setup instrument reduction parameters from instname_parameter.xml file

    if the instrument has already been defined, does nothing unless
    reload = True is specified
    """

    global Reducer
    if instname == None :
        instname = config['default.instrument']


    if not (Reducer is None) :
        if  Reducer.instr_name.upper()[0:3] == instname.upper()[0:3] :
            if not reload :
                # reinitialize idf parameters to defaults.
                Reducer.init_idf_params(True);
                return  # has been already defined

    Reducer = DRC.setup_reducer(instname)
Example #4
0
tiny=1e-10
huge=1e10

v_out_lo = 0.01
v_out_hi = 100.

vv_lo = 0.1
vv_hi = 2.0
vv_sig = 0.0

sv_sig = 3.3
sv_hi = 1.5
sv_lo = 0.0
s_zero = True

reducer = reduction.setup_reducer('MAPS')
diag_mask = reducer.diagnose(white, sample=sample, tiny=tiny, huge=huge, 
                             van_out_lo=v_out_lo, van_out_hi=v_out_hi,
                             van_lo=vv_lo, van_hi=vv_hi, van_sig=vv_sig,
                             samp_lo=sv_lo, samp_hi=sv_hi, samp_sig=sv_sig, samp_zero=s_zero)
Load("/home/pf9/code/systemtests/Data/MAP17269.raw", OutputWorkspace="MAP17269")
#print "***have mask"
#sample_ws = mtd[sample]
#print "***applying mask"
#MaskDetectors(sample_ws, MaskedWorkspace=diag_mask)
#print "***mask applied"
	
# Save the masked spectra nmubers to a simple ASCII file for comparison
#self.saved_diag_file = os.path.join(mtd.settings['defaultsave.directory'], 'CurrentDirectInelasticDiag.txt')
#handle = file(self.saved_diag_file, 'w')
#for index in range(sample_ws.getNumberHistograms()):