0
def createBrick(brickName,
                mountPoint,
                devNameList,
                fsType=DEFAULT_FS_TYPE,
                raidParams={}):
    def _getDeviceList(devNameList):
        return [
            blivetEnv.devicetree.getDeviceByName(devName.split("/")[-1])
            for devName in devNameList
        ]

    def _createPV(deviceList, alignment):
        for dev in deviceList:
            # bz#1178705: Blivet always creates pv with 1MB dataalignment
            # Workaround: Till blivet fixes the issue, we use lvm pvcreate
            rc, out, err = commands.execCmd([
                _pvCreateCommandPath.cmd, '--dataalignment',
                '%sk' % alignment, dev.path
            ])
            if rc:
                raise ge.GlusterHostStorageDevicePVCreateFailedException(
                    dev.path, alignment, rc, out, err)
        _reset_blivet(blivetEnv)
        return _getDeviceList([dev.name for dev in deviceList])

    def _createVG(vgName, deviceList, stripeSize):
        # bz#1198568: Blivet always creates vg with 1MB stripe size
        # Workaround: Till blivet fixes the issue, use vgcreate command
        devices = ','.join([device.path for device in deviceList])
        rc, out, err = commands.execCmd([
            _vgCreateCommandPath.cmd, '-s',
            '%sk' % stripeSize, vgName, devices
        ])
        if rc:
            raise ge.GlusterHostStorageDeviceVGCreateFailedException(
                vgName, devices, stripeSize, rc, out, err)
        blivetEnv.reset()
        return blivetEnv.devicetree.getDeviceByName(vgName)

    def _createThinPool(poolName, vg, alignment, poolMetaDataSize,
                        poolDataSize):
        metaName = "meta-%s" % poolName
        vgPoolName = "%s/%s" % (vg.name, poolName)
        metaLv = LVMLogicalVolumeDevice(metaName,
                                        parents=[vg],
                                        size=blivet.size.Size(
                                            '%d KiB' % poolMetaDataSize))
        poolLv = LVMLogicalVolumeDevice(poolName,
                                        parents=[vg],
                                        size=blivet.size.Size('%d KiB' %
                                                              poolDataSize))
        blivetEnv.createDevice(metaLv)
        blivetEnv.createDevice(poolLv)
        blivetEnv.doIt()

        # bz#1100514: LVM2 currently only supports physical extent sizes
        # that are a power of 2. Till that support is available we need
        # to use lvconvert to achive that.
        # bz#1179826: blivet doesn't support lvconvert functionality.
        # Workaround: Till the bz gets fixed, lvconvert command is used
        rc, out, err = commands.execCmd([
            _lvconvertCommandPath.cmd, '--chunksize',
            '%sK' % alignment, '--thinpool', vgPoolName, '--poolmetadata',
            "%s/%s" % (vg.name, metaName), '--poolmetadataspar', 'n', '-y'
        ])

        if rc:
            raise ge.GlusterHostStorageDeviceLVConvertFailedException(
                vg.path, alignment, rc, out, err)
        rc, out, err = commands.execCmd(
            [_lvchangeCommandPath.cmd, '--zero', 'n', vgPoolName])
        if rc:
            raise ge.GlusterHostStorageDeviceLVChangeFailedException(
                vgPoolName, rc, out, err)
        _reset_blivet(blivetEnv)
        return blivetEnv.devicetree.getDeviceByName(poolLv.name)

    if os.path.ismount(mountPoint):
        raise ge.GlusterHostStorageMountPointInUseException(mountPoint)

    vgName = "vg-" + brickName
    poolName = "pool-" + brickName
    poolDataSize = 0
    count = 0
    raidType = raidParams.get('type')
    metaDataSizeKib = DEFAULT_METADATA_SIZE_KB
    if raidType == '6':
        count = raidParams['pdCount'] - 2
        alignment = raidParams['stripeSize'] * count
        chunkSize = alignment
    elif raidType == '10':
        count = raidParams['pdCount'] / 2
        alignment = raidParams['stripeSize'] * count
        chunkSize = DEFAULT_CHUNK_SIZE_KB
    else:  # Device type is JBOD
        alignment = DEFAULT_CHUNK_SIZE_KB
        chunkSize = DEFAULT_CHUNK_SIZE_KB

    blivetEnv = blivet.Blivet()
    _reset_blivet(blivetEnv)

    # get the devices list from the device name
    deviceList = _getDeviceList(devNameList)

    # raise an error when any device not actually found in the given list
    notFoundList = set(devNameList).difference(
        set([dev.name for dev in deviceList]))
    if notFoundList:
        raise ge.GlusterHostStorageDeviceNotFoundException(notFoundList)

    # raise an error when any device is used already in the given list
    inUseList = set(devNameList).difference(
        set([not _canCreateBrick(dev) or dev.name for dev in deviceList]))
    if inUseList:
        raise ge.GlusterHostStorageDeviceInUseException(inUseList)

    pvDeviceList = _createPV(deviceList, alignment)
    vg = _createVG(vgName, pvDeviceList, alignment)
    # The following calculation is based on the redhat storage performance doc
    # http://docbuilder.usersys.redhat.com/22522
    # /#chap-Configuring_Red_Hat_Storage_for_Enhancing_Performance

    # create ~16GB metadata LV (metaDataSizeKib) that has a size which is
    # a multiple of RAID stripe width if it is > minimum vg size
    # otherwise allocate a minimum of 0.5% of the data device size
    # and create data LV (poolDataSize) that has a size which is
    # a multiple of stripe width.
    vgSizeKib = int(_getDeviceSize(vg, 'KiB'))
    if _getDeviceSize(vg) < MIN_VG_SIZE:
        metaDataSizeKib = vgSizeKib * MIN_METADATA_PERCENT
    poolDataSize = vgSizeKib - metaDataSizeKib

    metaDataSizeKib = (metaDataSizeKib - (metaDataSizeKib % alignment))
    poolDataSize = (poolDataSize - (poolDataSize % alignment))

    # Creating a thin pool from the data LV and the metadata LV
    # lvconvert --chunksize alignment --thinpool VOLGROUP/thin_pool
    #     --poolmetadata VOLGROUP/metadata_device_name
    pool = _createThinPool(poolName, vg, chunkSize, metaDataSizeKib,
                           poolDataSize)
    thinlv = LVMThinLogicalVolumeDevice(brickName,
                                        parents=[pool],
                                        size=vg.size,
                                        grow=True)
    blivetEnv.createDevice(thinlv)
    blivetEnv.doIt()

    if fsType != DEFAULT_FS_TYPE:
        log.error("fstype %s is currently unsupported" % fsType)
        raise ge.GlusterHostStorageDeviceMkfsFailedException(
            thinlv.path, alignment, raidParams.get('stripeSize', 0), fsType)

    format = blivet.formats.getFormat(DEFAULT_FS_TYPE,
                                      device=thinlv.path,
                                      mountopts=DEFAULT_MOUNT_OPTIONS)
    format._defaultFormatOptions = ["-f", "-i", "size=512", "-n", "size=8192"]
    if raidParams.get('type') == '6':
        format._defaultFormatOptions += [
            "-d", "sw=%s,su=%sk" % (count, raidParams.get('stripeSize'))
        ]
    blivetEnv.formatDevice(thinlv, format)
    blivetEnv.doIt()

    try:
        os.makedirs(mountPoint)
    except OSError as e:
        if errno.EEXIST != e.errno:
            errMsg = "[Errno %s] %s: '%s'" % (e.errno, e.strerror, e.filename)
            raise ge.GlusterHostStorageDeviceMakeDirsFailedException(
                err=[errMsg])
    thinlv.format.setup(mountpoint=mountPoint)
    blivetEnv.doIt()

    # bz#1230495: lvm devices are invisible and appears only after vgscan
    # Workaround: Till the bz gets fixed, We use vgscan to refresh LVM devices
    rc, out, err = commands.execCmd([_vgscanCommandPath.cmd])
    if rc:
        raise ge.GlusterHostStorageDeviceVGScanFailedException(rc, out, err)
    fstab.FsTab().add(thinlv.path,
                      mountPoint,
                      DEFAULT_FS_TYPE,
                      mntOpts=[DEFAULT_MOUNT_OPTIONS])
    return _getDeviceDict(thinlv)
Example #2
0
def createBrick(brickName,
                mountPoint,
                devNameList,
                fsType=DEFAULT_FS_TYPE,
                raidParams={}):
    def _getDeviceList(devNameList):
        return [
            blivetEnv.devicetree.getDeviceByName(devName.split("/")[-1])
            for devName in devNameList
        ]

    def _makePartition(deviceList):
        pvDeviceList = []
        doPartitioning = False
        for dev in deviceList:
            if dev.type not in ['disk', 'dm-multipath']:
                pvDeviceList.append(dev)
            else:
                blivetEnv.initializeDisk(dev)
                part = blivetEnv.newPartition(fmt_type="lvmpv",
                                              grow=True,
                                              parents=[dev])
                blivetEnv.createDevice(part)
                pvDeviceList.append(part)
                doPartitioning = True

        if doPartitioning:
            blivet.partitioning.doPartitioning(blivetEnv)
        return pvDeviceList

    def _createPV(deviceList, alignment=0):
        def _createAlignedPV(deviceList, alignment):
            for dev in deviceList:
                rc, out, err = lvm._createpv([dev.path],
                                             metadataSize=0,
                                             options=('--dataalignment',
                                                      '%sK' % alignment))
                if rc:
                    raise ge.GlusterHostStorageDevicePVCreateFailedException(
                        dev.path, alignment, rc, out, err)

            blivetEnv.reset()
            return _getDeviceList([dev.name for dev in deviceList])

        if alignment:
            blivetEnv.doIt()
            return _createAlignedPV(deviceList, alignment)

        for dev in deviceList:
            lvmpv = blivet.formats.getFormat("lvmpv", device=dev.path)
            blivetEnv.formatDevice(dev, lvmpv)

        blivet.partitioning.doPartitioning(blivetEnv)
        return deviceList

    def _createVG(vgName, deviceList, stripeSize=0):
        if stripeSize:
            vg = LVMVolumeGroupDevice(vgName,
                                      peSize=blivet.size.Size('%s KiB' %
                                                              stripeSize),
                                      parents=deviceList)
        else:
            vg = LVMVolumeGroupDevice(vgName, parents=deviceList)

        blivetEnv.createDevice(vg)
        return vg

    def _createThinPool(poolName,
                        vg,
                        alignment=0,
                        poolMetaDataSize=0,
                        poolDataSize=0):
        if not alignment:
            # bz#1180228: blivet doesn't handle percentage-based sizes properly
            # Workaround: Till the bz gets fixed, we take only 99% size from vg
            pool = LVMThinPoolDevice(poolName,
                                     parents=[vg],
                                     size=(vg.size * 99 / 100),
                                     grow=True)
            blivetEnv.createDevice(pool)
            return pool
        else:
            metaName = "meta-%s" % poolName
            vgPoolName = "%s/%s" % (vg.name, poolName)
            metaLv = LVMLogicalVolumeDevice(metaName,
                                            parents=[vg],
                                            size=blivet.size.Size(
                                                '%d KiB' % poolMetaDataSize))
            poolLv = LVMLogicalVolumeDevice(poolName,
                                            parents=[vg],
                                            size=blivet.size.Size(
                                                '%d KiB' % poolDataSize))
            blivetEnv.createDevice(metaLv)
            blivetEnv.createDevice(poolLv)
            blivetEnv.doIt()

            # bz#1100514: LVM2 currently only supports physical extent sizes
            # that are a power of 2. Till that support is available we need
            # to use lvconvert to achive that.
            # bz#1179826: blivet doesn't support lvconvert functionality.
            # Workaround: Till the bz gets fixed, lvconvert command is used
            rc, out, err = utils.execCmd([
                _lvconvertCommandPath.cmd, '--chunksize',
                '%sK' % alignment, '--thinpool', vgPoolName, '--poolmetadata',
                "%s/%s" % (vg.name, metaName), '--poolmetadataspar', 'n', '-y'
            ])

            if rc:
                raise ge.GlusterHostStorageDeviceLVConvertFailedException(
                    vg.path, alignment, rc, out, err)

            rc, out, err = utils.execCmd(
                [_lvchangeCommandPath.cmd, '--zero', 'n', vgPoolName])
            if rc:
                raise ge.GlusterHostStorageDeviceLVChangeFailedException(
                    vgPoolName, rc, out, err)

            blivetEnv.reset()
            return blivetEnv.devicetree.getDeviceByName(poolLv.name)

    vgName = "vg-" + brickName
    poolName = "pool-" + brickName
    alignment = 0
    chunkSize = 0
    poolDataSize = 0
    count = 0
    metaDataSize = DEFAULT_METADATA_SIZE_KB
    if raidParams.get('type') == '6':
        count = raidParams['pdCount'] - 2
        alignment = raidParams['stripeSize'] * count
        chunkSize = alignment
    elif raidParams.get('type') == '10':
        count = raidParams['pdCount'] / 2
        alignment = raidParams['stripeSize'] * count
        chunkSize = DEFAULT_CHUNK_SIZE_KB

    blivetEnv = blivet.Blivet()
    blivetEnv.reset()

    deviceList = _getDeviceList(devNameList)

    notFoundList = set(devNameList).difference(
        set([dev.name for dev in deviceList]))
    if notFoundList:
        raise ge.GlusterHostStorageDeviceNotFoundException(notFoundList)

    inUseList = set(devNameList).difference(
        set([not _canCreateBrick(dev) or dev.name for dev in deviceList]))
    if inUseList:
        raise ge.GlusterHostStorageDeviceInUseException(inUseList)

    pvDeviceList = _makePartition(deviceList)
    pvDeviceList = _createPV(pvDeviceList, alignment)
    vg = _createVG(vgName, pvDeviceList, raidParams.get('stripeSize', 0))

    # The following calculation is based on the redhat storage performance doc
    # http://docbuilder.usersys.redhat.com/22522
    # /#chap-Configuring_Red_Hat_Storage_for_Enhancing_Performance

    if alignment:
        vgSizeKib = int(vg.size.convertTo(spec="KiB"))
        if vg.size.convertTo(spec='MiB') < MIN_VG_SIZE:
            metaDataSize = vgSizeKib * MIN_METADATA_PERCENT
        poolDataSize = vgSizeKib - metaDataSize
        metaDataSize = (metaDataSize - (metaDataSize % alignment))
        poolDataSize = (poolDataSize - (poolDataSize % alignment))

    pool = _createThinPool(poolName, vg, chunkSize, metaDataSize, poolDataSize)
    thinlv = LVMThinLogicalVolumeDevice(brickName,
                                        parents=[pool],
                                        size=pool.size,
                                        grow=True)
    blivetEnv.createDevice(thinlv)
    blivetEnv.doIt()

    if fsType != DEFAULT_FS_TYPE:
        log.error("fstype %s is currently unsupported" % fsType)
        raise ge.GlusterHostStorageDeviceMkfsFailedException(
            thinlv.path, alignment, raidParams.get('stripeSize', 0), fsType)

    format = blivet.formats.getFormat(DEFAULT_FS_TYPE, device=thinlv.path)
    if alignment:
        format._defaultFormatOptions = [
            "-f", "-K", "-i", "size=512", "-d",
            "sw=%s,su=%sk" % (count, raidParams.get('stripeSize')), "-n",
            "size=8192"
        ]
    blivetEnv.formatDevice(thinlv, format)
    blivetEnv.doIt()

    try:
        os.makedirs(mountPoint)
    except OSError as e:
        if errno.EEXIST != e.errno:
            errMsg = "[Errno %s] %s: '%s'" % (e.errno, e.strerror, e.filename)
            raise ge.GlusterHostStorageDeviceMakeDirsFailedException(
                err=[errMsg])
    thinlv.format.setup(mountpoint=mountPoint)
    blivetEnv.doIt()
    fstab.FsTab().add(thinlv.path, mountPoint, DEFAULT_FS_TYPE)
    return _getDeviceDict(thinlv)