Example #1
0
def pingLan():
    if lanIP == dbOneIp and lanIP != dbTwoIp:
        portOK = chkPort(dbTwoIp, int(3307))
        if not portOK:
            doPing(dbTwoIp, int(3307))
        else:
            if sDb.read(telIP, "lanAlarm") == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
                sub = "DBTX LanIP is OK: %s" % ps1
                msg = "DateTime: %s\n 备库: %s, 网络与端口恢复正常." % (getTimeNow(), dbTwoIp)
                saveLog.info(msg)
                sendMail(sub, msg)
                sDb.update(telIP, "lanAlarm", "ON")
    elif lanIP != dbOneIp and lanIP == dbTwoIp:
        portOK = chkPort(dbOneIp, int(3306))
        if not portOK:
            doPing(dbOneIp, int(3306))
        else:
            if sDb.read(telIP, "lanAlarm") == "OFF":
                sub = "DBTX LanIP is OK: %s" % ps1
                msg = "DateTime: %s\n 备库: %s, 网络与端口恢复正常." % (getTimeNow(), dbTwoIp)
                saveLog.info(msg)
                sendMail(sub, msg)
                sDb.update(telIP, "lanAlarm", "ON")
    else:
        pass
Example #2
0
 def getDisk(self):
     mountPoints, diskTotal = [], 0          #diskTotal累加
     parts = psutil.disk_partitions()        #分区信息
     for p in parts:
         mp = str(p).split(",")[1].split("=")[1]
         mountPoints.append(mp)
     for x in mountPoints:
         pTotal = psutil.disk_usage(x.strip("'")).total      #单个分区容量
         diskTotal += pTotal
     diskTotal = changeUnit(int(diskTotal))
     rootSize, rootRate = psutil.disk_usage('/').free, psutil.disk_usage('/').percent    #获取/分区的剩余空间和使用率
     writeToFile("totalDisk", diskTotal)
     writeToFile("rootSize", changeUnit(int(rootSize)))
     writeToFile("rootRate", rootRate)
     if float(rootRate) > float(85):
         """ON开关,防止多次重复报警;报警一次之后设为关闭"""
         if self.sDb.read(self.telIP, "rootAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
             sub = "DBTX ROOT partition Alarm:%s" % self.ps1
             msg = "DateTime: %s\n根分区已使用%s%%, 超过85%%, 请警惕!!!" % (getTimeNow(), rootRate)
             saveLog.warning(msg)
             sendMail(sub, msg)
             self.sDb.update(self.telIP, "rootAlarm", "OFF")    ## 报警后,将开关置为"OFF"
     else:
         if self.sDb.read(self.telIP, "rootAlarm") == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
             sub = "DBTX ROOT partition is OK:%s" % self.ps1
             msg = "DateTime: %s\n根分区可用空间充足%s." % (getTimeNow(), changeUnit(int(rootSize)))
             saveLog.info(msg)
             sendMail(sub, msg)
             self.sDb.update(self.telIP, "rootAlarm", "ON")     ## 使用率不足85%时,将开关置为"ON"
Example #3
0
def doPing(tIP, dbPort):
    if dbPort == 3307:
        mString = "备库-%s-3307端口不通" % tIP
    else:
        mString = "主库-%s-3306端口不通" % tIP
    p = subprocess.Popen("ping -c7 %s" % tIP,shell=True,stdout=subprocess.PIPE,stderr=subprocess.PIPE)
    pResult = p.stdout.read()
    lossRate = pResult.split("---")[-1].split(",")[2].split()[0]  ## 取丢包率
    if float(lossRate[:-1]) > 20:
        sub = "DBTX LanIP Alarm: %s" % ps1
        msg = "DateTime: %s\n%s, ICMP-Ping丢包率:%s%% !!!" % (getTimeNow(), mString, lossRate)
    else:
        sub = "DBTX LanIP-Port Alarm: %s" % ps1
        msg = "DateTime: %s\n%s, ICMP-Ping正常,可能是MySQL挂了或者防火墙对应端口没有开启 !!!" % (getTimeNow(), mString)
    saveLog.error(msg)

    if sDb.read(telIP, "lanAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
        sendMail(sub, msg)
        sDb.update(telIP, "lanAlarm", "OFF")    ## 报警后,将开关置为"OFF"
Example #4
0
 def getNginxStatus(self):
     try:
         if os.path.exists("/usr/local/nginx/logs/nginx.pid"):
             fObj = open("/usr/local/nginx/logs/nginx.pid")
             ngxMainPid = fObj.read().strip()
             fObj.close()
         else:
             ngxMainPid = 0
         pids = getProcessID("nginx")
         if ngxMainPid:
             if not pids or len(pids) < 8:
                 wp = ""
                 res = os.popen("ps -C nginx -o pid,cmd").readlines()
                 for l in res:
                     wp += "\n" + l.strip()
                 if self.sDb.read(telIP, "ngxAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                     sub = "DBTX Nginx Alarm: %s" % ps1
                     msg = "Datetime: %s\nNginx主进程PID:%s\nWorker_processes:%s\n少于10个!!" % (getTimeNow(), ngxMainPid, wp)
                     saveLog.warning(msg)
                     sendMail(sub, msg)
                     self.sDb.update(telIP, "ngxAlarm", "OFF")
             else:
                 if self.sDb.read(telIP, "ngxAlarm") == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
                     sub = "DBTX Nginx is OK: %s" % ps1
                     msg = "Datetime: %s\nNginx主进程恢复开启状态." % (getTimeNow())
                     saveLog.info(msg)
                     sendMail(sub, msg)
                     self.sDb.update(telIP, "ngxAlarm", "ON")
         else:
             if self.sDb.read(telIP, "ngxAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                 sub = "DBTX Nginx Alarm: %s" % ps1
                 msg = "Datetime: %s\nNginx主进程挂了!!" % (getTimeNow())
                 saveLog.warning(msg)
                 sendMail(sub, msg)
                 self.sDb.update(telIP, "ngxAlarm", "OFF")
     except Exception,err:
         saveLog.warning("getNginxStatus, %s" % str(err))
Example #5
0
def appCpuAnalyze(srvPidStatus, srvFlag, sDb):
    from dbtx.Merge.etc import ps1
    corMuser = "******"
    tNowCpu = topNow()
    if not sDb.exists(srvFlag, "ct"):  ## Redis库中不存在该服区标识,初始化游戏程序占用CPU达到95%的次数
        sDb.intAppCpuCt(srvFlag)

    for app in srvPidStatus:
        appName = app.split("_")[0]
        if srvPidStatus[app][app+"_status"] == 0 or "Snapshot" in app:     ## 如果app状态异常,不检测CPU,MEM信息,忽略掉Snapshot
            continue
        appPid = srvPidStatus[app][app+"_pid"].split()
        for pid in appPid:   ## CellApp,GateApp,CopyApp会有多个进程ID
            nCpu, appCount = tNowCpu[pid], int(sDb.read(appName, srvFlag))
            if float(nCpu) > 95.5:   ## CPU使用率都大于95%时,count+1
                appCount += 1
                sDb.update(appName, srvFlag, appCount)     ## 将新的count值更新到Redis库
            else:
                sDb.update(appName, srvFlag, 0)            ## 如果没有超过95%,则置为0

            if int(appCount) >= 8:
                if sDb.read(srvFlag, "isFixing") == "OFF":         ## 如果维护标识为"OFF"
                    if sDb.read(srvFlag, "appCpuAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                        sub = "DBTX App-CPU Alarm: %s" % ps1
                        msg = "DateTime: %s\n%s CPU使用率连续五次达到95%%, 进程ID为: %s !!!" % (getTimeNow(), app, pid)
                        saveLog.warning(msg)
                        sendMail(sub, msg, corMuser)
##                        sDb.updateDb(mulDb, srvFlag, "appCpuAlarm", "OFF")    ## 报警后,将开关置为"OFF"
                        sDb.update(appName, srvFlag, 0)                                       ## 报警后,重置count值

            if "DbCacheApp_"+srvFlag == app:
                proc = psutil.Process(int(pid))
                shr = proc.get_ext_memory_info()[2]
                if float(shr) > 1932735283.2:    ## DbCacheApp共享内存大于1.8G时,报警
                    if sDb.read(srvFlag, "isFixing") == "OFF":         ## 如果维护标识为"OFF"
                        if sDb.read(srvFlag, "appShrAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                            sub = "DBTX DbCacheApp-SHR Alarm: %s" % ps1
                            msg = "DateTime: %s\n%s DbCacheApp 共享内存达到红色警戒,当前占用共享内存: %s !!!" % (getTimeNow(), srvFlag, changeUnit(shr))
                            saveLog.warning(msg)
                            sendMail(sub, msg, corMuser)
                            sDb.update(srvFlag, "appShrAlarm", "OFF")    ## 报警后,将开关置为"OFF"
                else:
                    if sDb.read(srvFlag, "isFixing") == "OFF":         ## 如果维护标识为"OFF"
                        if sDb.read(srvFlag, "appShrAlarm") == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
                            sub = "DBTX DbCacheApp-SHR Alarm: %s" % ps1
                            msg = "DateTime: %s\n%s DbCacheApp 占用共享内存恢复到正常水平: %s ." % (getTimeNow(), srvFlag, changeUnit(shr))
                            saveLog.warning(msg)
                            sendMail(sub, msg, corMuser)
                            sDb.update(srvFlag, "appShrAlarm", "ON")
Example #6
0
def gateAnalyze(srvFlag, nowNu, sDb):
    from dbtx.Merge.etc import ps1
    pubFile = "/opt/dbtx/" + str(srvFlag) + "/config/public_config.xml"
    pubObj = open(pubFile)
    fixGateNum = ''.join([ l.strip().split(">")[1].split("<")[0] for l in pubObj.readlines() if "<GateNum>" in l])
    pubObj.close()
    corMuser = "******"

    if int(nowNu) < int(fixGateNum):
        if sDb.read(srvFlag, "isFixing") == "OFF":         ## 如果维护标识为"OFF"
            if sDb.read(srvFlag, "appNumAlarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                sub = "DBTX GateApps Alarm: %s" % ps1
                msg = "DateTime: %s\n%s 预设开启 %s 个GateApp,当前只有 %s 个,挂了 %s 个 !!!" % (getTimeNow(), srvFlag, fixGateNum, nowNu, (int(fixGateNum)-int(nowNu)))
                saveLog.warning(msg)
                sendMail(sub, msg, corMuser)
                sDb.update(srvFlag, "appNumAlarm", "OFF")    ## 报警后,将开关置为"OFF"
    else:
        if sDb.read(srvFlag, "isFixing") == "OFF":         ## 如果维护标识为"OFF"
            if sDb.read(srvFlag, "appNumAlarm") == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
                sub = "DBTX GateApps is OK: %s" % ps1
                msg = "DateTime: %s\n%s GateApp Numbers正常." % (getTimeNow(), srvFlag)
                saveLog.warning(msg)
                sendMail(sub, msg, corMuser)
                sDb.update(srvFlag, "appNumAlarm", "ON")
Example #7
0
        redisData["connects_rate"] = (int(redisData["total_connects"]) - int(last_connects)) / float(60)
        redisData["command_rate"] = (int(redisData["total_commands"]) - int(last_commands)) / float(60)

        fZbx = str(redisData).strip("{}").replace(",","\n").replace("'","")   ## 转换成zabbix需要的格式
        fObj = open(rZbx,'w')
        fObj.write(fZbx)
        fObj.close()
    except Exception,err:
        saveLog.error("getRedisBaseInfo(): %s" % str(err))

    ## 分析数据,必要时报警: 1, 使用内存大于1G; 2, 命中率低于20%
    if int(redisData["used_memory"]) > 1073741824:
        sDb = opRedis()    ## 实例化 Redis库操作类
        if sDb.read(telIP, "rRateAlarm") == "ON":
            sub = "DBTX Redis Memory Alarm: %s" % ps1
            msg = "DateTime: %s\nRedis使用内存为: %s, 超过1G,请警惕 !!!" % (getTimeNow(), changeUnit(int(redisData["used_memory"])))
            saveLog.warning(msg)
            sendMail(sub, msg)
            sDb.update(telIP, "rRateAlarm", "OFF")    ## 报警后,将开关置为"OFF"
    else:
        sDb = opRedis()    ## 实例化 Redis库操作类
        if sDb.read(telIP, "rRateAlarm") == "OFF":
            sub = "DBTX Redis Memory is OK: %s" % ps1
            msg = "DateTime: %s\nRedis使用内存情况正常: %s." % (getTimeNow(), changeUnit(int(redisData["used_memory"])))
            saveLog.info(msg)
            sendMail(sub, msg)
            sDb.update(telIP, "rRateAlarm", "ON")

##    if totalHits != 0 and redisData["hit_rate"] < 20:
##        sDb = opShelveDb()    ## 实例化 shelve库操作类
##        if sDb.readDb(pubDb, telIP, "rRateAlarm") == "ON":
Example #8
0
 def getServerTime(self):
     nowTime = getTimeNow()
     self.data_for_post += "server_time=%s&" % nowTime
Example #9
0
        nowTime = getTimeNow()
        self.data_for_post += "server_time=%s&" % nowTime


    def getDbStatus(self):
        ## 检查MySQL状态, 1 正常, 0 异常
        try:
            db1Status = chkPort(dbOneIp, db1Port)
            db2Status = chkPort(dbTwoIp, db2Port)
        except Exception, err:
            saveLog.error("getDbStatus() Error Occur : %s" % err)
        if db1Status:
            db1_status = 1
            if self.sDb.read(telIP, "db1Alarm") == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
                sub = "DBTX DB1 mysql is OK: %s" % ps1
                msg = "DateTime: %s\n主库-%s-3306端口 is up" % (getTimeNow(), dbOneIp)
                saveLog.info(msg)
                sendMail(sub, msg)
                self.sDb.update(telIP, "db1Alarm", "ON")
##            statusAnalyze("3306")    ## 获取其它性能数据,zabbix成图或报警
        else:
            db1_status = 0
            try:
                if self.sDb.read(telIP, "db1Alarm") == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                    sub = "DBTX DB1 mysql Alarm: %s" % ps1
                    msg = "DateTime: %s\n主库-%s-3306端口 DOWN 了,请查看日志 !!!" % (getTimeNow(), dbOneIp)
                    saveLog.warning(msg)
                    sendMail(sub, msg)
                    self.sDb.update(telIP, "db1Alarm", "OFF")    ## 报警后,将开关置为"OFF"
            except Exception, err:
                saveLog.error("db1Alarm() Error Occur : %s" % str(err))
Example #10
0
         if fixSwStat == "OFF":        ## 如果维护标识为"OFF"
             if appSwStat == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                 sub = "DBTX AppService Alarm: %s" % ps1
                 msg = "DateTime: %s\n%s 挂啦 !!!" % (getTimeNow(), srvStatus['Error'])
                 saveLog.warning(msg)
                 sendMail(sub, msg, mUser)
                 self.sDb.update(srvFlag, "appAlarm", "OFF")
     except Exception, err:
         saveLog.warning("app_status is 2,get switch status error occured.")
 elif srvStatus['Error'] and not srvStatus['Success']:  ## 全部处于关闭状态
     app_status = 0
     try:
         if fixSwStat == "OFF":        ## 如果维护标识为"OFF"
             if appSwStat == "ON":     ## 状态为"NO"且开关为"ON"时,报故障
                 sub = "DBTX AppService is Down: %s" % ps1
                 msg = "DateTime: %s\n%s AppService  关闭 !!!" % (getTimeNow(), srvFlag)
                 saveLog.warning(msg)
                 sendMail(sub, msg, mUser)
                 self.sDb.update(srvFlag, "appAlarm", "OFF")
     except Exception, err:
         saveLog.warning("app_status is 0,get switch status error occured.")
 elif not srvStatus['Error'] and srvStatus['Success']:  ## 全部处于开启状态
     app_status = 1
     appCpuAnalyze(srvPidStatus,srvFlag,self.sDb)
     self.getSrvVer(srvPidStatus)
     gateAnalyze(srvFlag,GateAppCount,self.sDb)
     try:
         if fixSwStat == "OFF":        ## 如果维护标识为"OFF"
             if appSwStat == "OFF":    ## 状态OK且开关为"OFF"时,报恢复
                 sub = "DBTX AppService is OK: %s" % ps1
                 msg = "DateTime: %s\n%s AppService  恢复开启 !!!" % (getTimeNow(), srvFlag)