Example #1
0
def calibrate_readout(device, qubit_id, qubit_readout_pulse, transition='01', ignore_other_qubits=None):
    adc, mnames = device.setup_adc_reducer_iq(qubit_id, raw=True)
    nums = int(device.get_qubit_constant(qubit_id=qubit_id, name='readout_background_nums'))
    old_nums = adc.get_adc_nums()
    adc.set_adc_nop(int(device.get_sample_global('readout_adc_points')))
    if ignore_other_qubits is None:
        ignore_other_qubits = (device.get_qubit_constant(qubit_id=qubit_id, name='readout_calibration_ignore_other_qubits') == 'True')
    print ('ignore_other_qubits', ignore_other_qubits)

    other_qubit_pulse_sequence = []
    references = {}
    if not ignore_other_qubits:
        for other_qubit_id in device.get_qubit_list():
            if other_qubit_id != qubit_id:
                half_excited_pulse = excitation_pulse.get_excitation_pulse(device, other_qubit_id,
                                                                           rotation_angle=np.pi / 2.)
                references[('other_qubit_pulse', other_qubit_id)] = half_excited_pulse.id
                other_qubit_pulse_sequence.extend(half_excited_pulse.get_pulse_sequence(0))

    qubit_excitation_pulse = excitation_pulse.get_excitation_pulse(device, qubit_id, rotation_angle=np.pi)
    metadata = {'qubit_id': qubit_id,
                'averages': nums,
                'ignore_other_qubits': ignore_other_qubits}

    references.update({'readout_pulse': qubit_readout_pulse.id,
                       'excitation_pulse': qubit_excitation_pulse.id,
                       'delay_calibration': device.modem.delay_measurement.id})

    classifier = single_shot_readout.single_shot_readout(adc=adc,
                                                         prepare_seqs=[device.pre_pulses + other_qubit_pulse_sequence,
                                                                       device.pre_pulses + other_qubit_pulse_sequence + qubit_excitation_pulse.get_pulse_sequence(
                                                                           0)],
                                                         ro_seq=device.trigger_readout_seq + qubit_readout_pulse.get_pulse_sequence(),
                                                         pulse_generator=device.pg,
                                                         ro_delay_seq=None,
                                                         _readout_classifier=readout_classifier.binary_linear_classifier(),
                                                         adc_measurement_name='Voltage')

    classifier.readout_classifier.cov_mode = 'equal'

    try:
        adc.set_adc_nums(nums)
        measurement = device.sweeper.sweep(classifier,
                                           measurement_type='readout_calibration',
                                           metadata=metadata,
                                           references=references)
    except:
        raise
    finally:
        adc.set_adc_nums(old_nums)

    return measurement
Example #2
0
def readout_Zgate_scan(device, qubit_id, qubit_readout_pulse, Zgate, amplitudes,  transition='01', ignore_other_qubits=None):
    adc, mnames = device.setup_adc_reducer_iq(qubit_id, raw=True)
    nums = int(device.get_qubit_constant(qubit_id=qubit_id, name='readout_background_nums'))
    old_nums = adc.get_adc_nums()
    adc.set_adc_nop(int(device.get_sample_global('readout_adc_points')))
    if ignore_other_qubits is None:
        ignore_other_qubits = (device.get_qubit_constant(qubit_id=qubit_id, name='readout_calibration_ignore_other_qubits') == 'True')
    print ('ignore_other_qubits', ignore_other_qubits)

    other_qubit_pulse_sequence = []
    references = {}
    if not ignore_other_qubits:
        for other_qubit_id in device.get_qubit_list():
            if other_qubit_id != qubit_id:
                half_excited_pulse = excitation_pulse.get_excitation_pulse(device, other_qubit_id,
                                                                           rotation_angle=np.pi / 2.)
                references[('other_qubit_pulse', other_qubit_id)] = half_excited_pulse.id
                other_qubit_pulse_sequence.extend(half_excited_pulse.get_pulse_sequence(0)[0])

    qubit_excitation_pulse = excitation_pulse.get_excitation_pulse(device, qubit_id, rotation_angle=np.pi)
    metadata = {'qubit_id': qubit_id,
                'averages': nums,
                'ignore_other_qubits': ignore_other_qubits}

    references.update({'readout_pulse': qubit_readout_pulse.id,
                       'excitation_pulse': qubit_excitation_pulse.id,
                       'delay_calibration': device.modem.delay_measurement.id,
                      'Zgate': Zgate.id},
                      )

    classifier = single_shot_readout.single_shot_readout(adc=adc,
                                                         prepare_seqs=[
                                                             device.pre_pulses + other_qubit_pulse_sequence,
                                                             device.pre_pulses + other_qubit_pulse_sequence + qubit_excitation_pulse.get_pulse_sequence(0)],
                                                         ro_seq=device.trigger_readout_seq + qubit_readout_pulse.get_pulse_sequence(),
                                                         control_seq=None,
                                                         # pulse_generator=device.pg,
                                                         ro_delay_seq=None,
                                                         _readout_classifier=readout_classifier.binary_linear_classifier(),
                                                         adc_measurement_name='Voltage')

    def set_Zgate_amplitude(x):
        channel_amplitudes1_ = channel_amplitudes.channel_amplitudes(device,
                                                                     **{Zgate.metadata[
                                                                            'carrier_name']: x})
        print(channel_amplitudes1_)

        pulse_seq1 = excitation_pulse.get_rect_cos_pulse_sequence(device=device,
                                                                  channel_amplitudes=channel_amplitudes1_,
                                                                  tail_length=float(Zgate.metadata['tail_length']),
                                                                  length=float(qubit_readout_pulse.metadata['length']),
                                                                  phase=0.0)

        classifier.ro_seq =  device.trigger_readout_seq + device.pg.parallel(pulse_seq1,qubit_readout_pulse.get_pulse_sequence())

    classifier.readout_classifier.cov_mode = 'equal'

    try:
        adc.set_adc_nums(nums)
        measurement = device.sweeper.sweep(classifier,
                                           (amplitudes, set_Zgate_amplitude, 'amplitude', 'Voltage'),
                                           measurement_type='readout_Zgate_scan',
                                           metadata=metadata,
                                           references=references)
    except:
        raise
    finally:
        adc.set_adc_nums(old_nums)

    return measurement
    # classifier.repeat_samples = 2
Example #3
0
def readout_fidelity_scan(device, qubit_id, readout_pulse_lengths, readout_pulse_amplitudes,
                          recalibrate_excitation=True, ignore_other_qubits=False, channel_amplitudes=None):
    adc, mnames = device.setup_adc_reducer_iq(qubit_id, raw=True)
    nums = int(device.get_qubit_constant(qubit_id=qubit_id, name='readout_background_nums'))
    adc.set_adc_nop(int(device.get_sample_global('readout_adc_points')))
    old_nums = adc.get_adc_nums()

    readout_channel = [i for i in device.get_qubit_readout_channel_list(qubit_id).keys()][0]

    other_qubit_pulse_sequence = []
    references = {'frequency_controls': device.get_frequency_control_measurement_id(qubit_id=qubit_id)}
    if hasattr(device.awg_channels[readout_channel], 'get_calibration_measurement'):
        references['channel_calibration'] = device.awg_channels[readout_channel].get_calibration_measurement()

    if not ignore_other_qubits:
        for other_qubit_id in device.get_qubit_list():
            if other_qubit_id != qubit_id:

                '''Warning'''
                #TODO
                half_excited_pulse = excitation_pulse.get_excitation_pulse(device, other_qubit_id,
                                                                           rotation_angle=np.pi / 2.,
                                                                           recalibrate=recalibrate_excitation)
                references[('other_qubit_pulse', other_qubit_id)] = half_excited_pulse.id
                other_qubit_pulse_sequence.extend(half_excited_pulse.get_pulse_sequence(0))

    '''Warning'''
    # TODO
    qubit_excitation_pulse = excitation_pulse.get_excitation_pulse(device, qubit_id, rotation_angle=np.pi, channel_amplitudes_override=channel_amplitudes,
                                                                   recalibrate=recalibrate_excitation)
    metadata = {'qubit_id': qubit_id,
                'averages': nums,
                'channel': readout_channel,
                'ignore_other_qubits': ignore_other_qubits}

    # print ('len(readout_pulse_lengths): ', len(readout_pulse_lengths))
    if len(readout_pulse_lengths) == 1:
        metadata['length'] = str(readout_pulse_lengths[0])

    references.update({'excitation_pulse': qubit_excitation_pulse.id,
                       'delay_calibration': device.modem.delay_measurement.id})

    #TODO
    exitation_channel = [i for i in device.get_qubit_excitation_channel_list(qubit_id).keys()][0]
    ex_channel = device.awg_channels[exitation_channel]
    if ex_channel.is_iq():
        control_seq_id = ex_channel.parent.sequencer_id
    else:
        control_seq_id = ex_channel.channel//2
    ex_sequencers = []
    for seq_id in device.pre_pulses.seq_in_use:
        if seq_id != control_seq_id:
            ex_seq = zi_scripts.SIMPLESequence(sequencer_id=seq_id, awg=device.modem.awg,
                                               awg_amp=1, use_modulation=True, pre_pulses = [])
        else:
            ex_seq = zi_scripts.SIMPLESequence(sequencer_id=seq_id, awg=device.modem.awg,
                                               awg_amp=1, use_modulation=True, pre_pulses=[], control=True)
            control_sequence = ex_seq

        device.pre_pulses.set_seq_offsets(ex_seq)
        device.pre_pulses.set_seq_prepulses(ex_seq)
        ex_seq.start()
        ex_sequencers.append(ex_seq)
    sequence_control.set_preparation_sequence(device, ex_sequencers, other_qubit_pulse_sequence+
                                                                       qubit_excitation_pulse.get_pulse_sequence(0))

    '''Warning'''
    #readout_sequencer = sequence_control.define_readout_control_seq(device, readout_channel)
    #raise ValueError('fallos')
    re_channel = device.awg_channels[readout_channel]
    readout_sequencer = zi_scripts.READSequence(re_channel.parent.sequencer_id, device.modem.awg)

    def_frag, play_frag = device.pg.readout_rect(channel=readout_channel, length=readout_pulse_lengths[0],
                                                 amplitude=readout_pulse_amplitudes[0])
    readout_sequencer.add_readout_pulse(def_frag, play_frag)
    readout_sequencer.stop()
    device.modem.awg.set_sequence(readout_sequencer.params['sequencer_id'], readout_sequencer)
    readout_sequencer.set_delay(device.modem.trigger_channel.delay)
    readout_sequencer.start()

    classifier = single_shot_readout.single_shot_readout(device=device,
                                                         adc=adc,
                                                         prepare_seqs=[other_qubit_pulse_sequence,
                                                                       other_qubit_pulse_sequence +
                                                                       qubit_excitation_pulse.get_pulse_sequence(0)],
                                                         ex_seqs=ex_sequencers,
                                                         ro_seq=readout_sequencer,
                                                         control_seq=control_sequence,
                                                         #pulse_generator=device.pg,
                                                         ro_delay_seq=None,
                                                         _readout_classifier=readout_classifier.binary_linear_classifier(),
                                                         adc_measurement_name='Voltage',
                                                         dbg_storage=False)

    classifier.readout_classifier.cov_mode = 'equal'

    # setters for sweep
    readout_amplitude = 0
    readout_length = 0

    class ParameterSetter:
        def __init__(self):
            self.readout_amplitude = 0
            self.readout_length = 0
            self.channel = readout_channel

        def set_readout_amplitude(self, x):
            #nonlocal readout_amplitude
            self.readout_amplitude = x
            #classifier.ro_seq = device.trigger_readout_seq + [
            #    device.pg.p(readout_channel, readout_length, device.pg.rect, readout_amplitude)]
            classifier.ro_seq.set_awg_amp(x)

        def set_readout_length(self, x):
            #nonlocal readout_length
            self.readout_length = x
            #classifier.ro_seq = device.trigger_readout_seq + [
            #    device.pg.p(readout_channel, readout_length, device.pg.rect, readout_amplitude)]
            classifier.ro_seq.awg.stop_seq(classifier.ro_seq.params['sequencer_id'])
            def_frag, play_frag = device.pg.readout_rect(channel=self.channel,
                                                        length=self.readout_length,
                                                        amplitude=self.readout_amplitude)
            classifier.ro_seq.clear_readout_pulse()
            classifier.ro_seq.add_readout_pulse(def_frag, play_frag)
            device.modem.awg.set_sequence(classifier.ro_seq.params['sequencer_id'], classifier.ro_seq)
            classifier.ro_seq.awg.start_seq(classifier.ro_seq.params['sequencer_id'])

    setter = ParameterSetter()

    try:
        adc.set_adc_nums(nums)
        measurement = device.sweeper.sweep(classifier,
                                           (readout_pulse_lengths, setter.set_readout_length, 'length', 's'),
                                           (readout_pulse_amplitudes, setter.set_readout_amplitude, 'amplitude', ''),
                                           measurement_type='readout_fidelity_scan',
                                           metadata=metadata,
                                           references=references)
    except:
        raise
    finally:
        adc.set_adc_nums(old_nums)

    return measurement
Example #4
0
def calibrate_readout(device, qubit_id, qubit_readout_pulse, transition='01', ignore_other_qubits=None):
    adc, mnames = device.setup_adc_reducer_iq(qubit_id, raw=True)
    nums = int(device.get_qubit_constant(qubit_id=qubit_id, name='readout_background_nums'))
    old_nums = adc.get_adc_nums()
    adc.set_adc_nop(int(device.get_sample_global('readout_adc_points')))
    if ignore_other_qubits is None:
        ignore_other_qubits = (device.get_qubit_constant(qubit_id=qubit_id, name='readout_calibration_ignore_other_qubits') == 'True')
    print ('ignore_other_qubits', ignore_other_qubits)

    other_qubit_pulse_sequence = []
    references = {}
    if not ignore_other_qubits:
        for other_qubit_id in device.get_qubit_list():
            if other_qubit_id != qubit_id:
                # TODO
                '''Warning'''
                half_excited_pulse = excitation_pulse.get_excitation_pulse(device, other_qubit_id,
                                                                           rotation_angle=np.pi / 2.)
                references[('other_qubit_pulse', other_qubit_id)] = half_excited_pulse.id
                other_qubit_pulse_sequence.extend(half_excited_pulse.get_pulse_sequence(0))
    # TODO
    '''Warning'''
    qubit_excitation_pulse = excitation_pulse.get_excitation_pulse(device, qubit_id, rotation_angle=np.pi)
    metadata = {'qubit_id': qubit_id,
                'averages': nums,
                'ignore_other_qubits': ignore_other_qubits}

    references.update({'readout_pulse': qubit_readout_pulse.id,
                       'excitation_pulse': qubit_excitation_pulse.id,
                       'delay_calibration': device.modem.delay_measurement.id})

    #TODO
    exitation_channel = [i for i in device.get_qubit_excitation_channel_list(qubit_id).keys()][0]
    ex_channel = device.awg_channels[exitation_channel]
    if ex_channel.is_iq():
        control_seq_id = ex_channel.parent.sequencer_id
    else:
        control_seq_id = ex_channel.channel//2
    ex_sequencers = []
    for seq_id in device.pre_pulses.seq_in_use:
        if seq_id != control_seq_id:
            ex_seq = zi_scripts.SIMPLESequence(sequencer_id=seq_id, awg=device.modem.awg,
                                               awg_amp=1, use_modulation=True, pre_pulses = [])
        else:
            ex_seq = zi_scripts.SIMPLESequence(sequencer_id=seq_id, awg=device.modem.awg,
                                               awg_amp=1, use_modulation=True, pre_pulses=[], control=True)
            control_sequence = ex_seq

        device.pre_pulses.set_seq_offsets(ex_seq)
        device.pre_pulses.set_seq_prepulses(ex_seq)
        ex_seq.start()
        ex_sequencers.append(ex_seq)
    sequence_control.set_preparation_sequence(device, ex_sequencers, other_qubit_pulse_sequence+
                                                                       qubit_excitation_pulse.get_pulse_sequence(0))

    '''Warning'''
    #readout_sequencer = sequence_control.define_readout_control_seq(device, readout_channel)
    #raise ValueError('fallos')

    readout_sequencer = sequence_control.define_readout_control_seq(device, qubit_readout_pulse)
    readout_sequencer.start()

    classifier = single_shot_readout.single_shot_readout(device=device,
                                                         adc=adc,
                                                         prepare_seqs=[other_qubit_pulse_sequence,
                                                                       other_qubit_pulse_sequence +
                                                                       qubit_excitation_pulse.get_pulse_sequence(0)],
                                                         ex_seqs=ex_sequencers,
                                                         ro_seq=readout_sequencer,
                                                         control_seq = control_sequence,
                                                         #pulse_generator=device.pg,
                                                         ro_delay_seq=None,
                                                         _readout_classifier=readout_classifier.binary_linear_classifier(),
                                                         adc_measurement_name='Voltage',
                                                         dbg_storage=False)

    classifier.readout_classifier.cov_mode = 'equal'

    try:
        adc.set_adc_nums(nums)
        measurement = device.sweeper.sweep(classifier,
                                           measurement_type='readout_calibration',
                                           metadata=metadata,
                                           references=references)
    except:
        raise
    finally:
        adc.set_adc_nums(old_nums)

    return measurement
Example #5
0
def readout_fidelity_scan(device, qubit_id, readout_pulse_lengths, readout_pulse_amplitudes,
                          recalibrate_excitation=True, ignore_other_qubits=False, channel_amplitudes=None):
    adc, mnames = device.setup_adc_reducer_iq(qubit_id, raw=True)
    nums = int(device.get_qubit_constant(qubit_id=qubit_id, name='readout_background_nums'))
    adc.set_adc_nop(int(device.get_sample_global('readout_adc_points')))
    old_nums = adc.get_adc_nums()

    readout_channel = [i for i in device.get_qubit_readout_channel_list(qubit_id).keys()][0]

    other_qubit_pulse_sequence = []
    references = {'frequency_controls': device.get_frequency_control_measurement_id(qubit_id=qubit_id)}
    if hasattr(device.awg_channels[readout_channel], 'get_calibration_measurement'):
        references['channel_calibration'] = device.awg_channels[readout_channel].get_calibration_measurement()

    if not ignore_other_qubits:
        for other_qubit_id in device.get_qubit_list():
            if other_qubit_id != qubit_id:
                half_excited_pulse = excitation_pulse.get_excitation_pulse(device, other_qubit_id,
                                                                           rotation_angle=np.pi / 2.,
                                                                           recalibrate=recalibrate_excitation)
                references[('other_qubit_pulse', other_qubit_id)] = half_excited_pulse.id
                other_qubit_pulse_sequence.extend(half_excited_pulse.get_pulse_sequence(0))

    qubit_excitation_pulse = excitation_pulse.get_excitation_pulse(device, qubit_id, rotation_angle=np.pi, channel_amplitudes_override=channel_amplitudes,
                                                                   recalibrate=recalibrate_excitation)
    metadata = {'qubit_id': qubit_id,
                'averages': nums,
                'channel': readout_channel,
                'ignore_other_qubits': ignore_other_qubits}

    # print ('len(readout_pulse_lengths): ', len(readout_pulse_lengths))
    if len(readout_pulse_lengths) == 1:
        metadata['length'] = str(readout_pulse_lengths[0])

    references.update({'excitation_pulse': qubit_excitation_pulse.id,
                       'delay_calibration': device.modem.delay_measurement.id})

    classifier = single_shot_readout.single_shot_readout(adc=adc,
                                                         prepare_seqs=[device.pre_pulses + other_qubit_pulse_sequence,
                                                                       device.pre_pulses + other_qubit_pulse_sequence +
                                                                       qubit_excitation_pulse.get_pulse_sequence(0)],
                                                         ro_seq=device.trigger_readout_seq,
                                                         pulse_generator=device.pg,
                                                         ro_delay_seq=None,
                                                         _readout_classifier=readout_classifier.binary_linear_classifier(),
                                                         adc_measurement_name='Voltage',
                                                         dbg_storage=False)

    classifier.readout_classifier.cov_mode = 'equal'

    # setters for sweep
    readout_amplitude = 0
    readout_length = 0

    def set_readout_amplitude(x):
        nonlocal readout_amplitude
        readout_amplitude = x
        classifier.ro_seq = device.trigger_readout_seq + [
            device.pg.p(readout_channel, readout_length, device.pg.rect, readout_amplitude)]

    def set_readout_length(x):
        nonlocal readout_length
        readout_length = x
        classifier.ro_seq = device.trigger_readout_seq + [
            device.pg.p(readout_channel, readout_length, device.pg.rect, readout_amplitude)]

    try:
        adc.set_adc_nums(nums)
        measurement = device.sweeper.sweep(classifier,
                                           (readout_pulse_lengths, set_readout_length, 'length', 's'),
                                           (readout_pulse_amplitudes, set_readout_amplitude, 'amplitude', ''),
                                           measurement_type='readout_fidelity_scan',
                                           metadata=metadata,
                                           references=references)
    except:
        raise
    finally:
        adc.set_adc_nums(old_nums)

    return measurement