Exemple #1
0
def main():

    qtapp = Qt.QApplication(sys.argv)  #setup plot window

    adr = adrcontrol.Adrcontrol(app=qtapp)

    #adr.AutoMag(StartHour = 8, StartMinute = 47, DaysFromNow = 0, Maguptime = 30, Magdowntime = 45, Holdtime = 75)
    #adr.AutoMag(StartHour = 3, StartMinute = 0, DaysFromNow = 3, Maguptime = 30, Magdowntime = 45, Holdtime = 240)
    adr.AutoMag(StartHour=3,
                StartMinute=0,
                DaysFromNow=1,
                Maguptime=30,
                Magdowntime=45,
                Holdtime=240)

    TempLogger.main(sys.argv, app=qtapp, startdata=True, Timerstep=5000)
Exemple #2
0
import adrcontrol

adr = adrcontrol.Adrcontrol()
adr.tempcontrol.PIDSetup()
adr.tempcontrol.SetTemperatureSetPoint(0.060)
Exemple #3
0
def main():

    qtapp = Qt.QApplication(sys.argv)  #setup plot window

    adr = adrcontrol.Adrcontrol(app=qtapp)
    bias_source0 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=0)
    bias_source1 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=1)
    bias_source2 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=2)
    bias_source3 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=3)
    bias_source4 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=4)
    bias_source5 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=5)
    bias_source6 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=6)
    bias_source7 = bluebox.BlueBox(port='vbox',
                                   version=voltage_source_select,
                                   address=bias_address,
                                   channel=7)

    sleep(2)

    print 'Base Warm Up Rate'

    bias_source0.setvolt(0)
    bias_source1.setvolt(0)
    bias_source2.setvolt(0)
    bias_source3.setvolt(0)
    bias_source4.setvolt(0)
    bias_source5.setvolt(0)
    bias_source6.setvolt(0)
    bias_source7.setvolt(0)

    sleep(pause_after_bias_set)

    filepath = root_directory + 'BaseWarmUp'
    adr.MonitorWarmUpRate(minutesToMeasure=minutesToMeasure, filepath=filepath)

    bias_source0.setvolt(normal_volt)
    bias_source1.setvolt(0)
    bias_source2.setvolt(0)
    bias_source3.setvolt(0)
    bias_source4.setvolt(0)
    bias_source5.setvolt(0)
    bias_source6.setvolt(0)
    bias_source7.setvolt(0)

    sleep(pause_after_bias_set)

    print 'One Bay On'
    filepath = root_directory + 'OneBaysOn'
    adr.MonitorWarmUpRate(minutesToMeasure=minutesToMeasure, filepath=filepath)

    bias_source0.setvolt(normal_volt)
    bias_source1.setvolt(normal_volt)
    bias_source2.setvolt(normal_volt)
    bias_source3.setvolt(normal_volt)
    bias_source4.setvolt(0)
    bias_source5.setvolt(0)
    bias_source6.setvolt(0)
    bias_source7.setvolt(0)

    sleep(pause_after_bias_set)

    print 'Four Bays On'
    filepath = root_directory + 'FourBaysOn'
    adr.MonitorWarmUpRate(minutesToMeasure=minutesToMeasure, filepath=filepath)

    bias_source0.setvolt(normal_volt)
    bias_source1.setvolt(normal_volt)
    bias_source2.setvolt(normal_volt)
    bias_source3.setvolt(normal_volt)
    bias_source4.setvolt(normal_volt)
    bias_source5.setvolt(normal_volt)
    bias_source6.setvolt(normal_volt)
    bias_source7.setvolt(normal_volt)

    sleep(pause_after_bias_set)

    print 'Eight Bays On'
    filepath = root_directory + 'EightBaysOn'
    adr.MonitorWarmUpRate(minutesToMeasure=minutesToMeasure, filepath=filepath)