def vm2vm_SRIOV_Dynamic_Container(cnx_server, isDPDK, nbrCores, isIsolated, numVMs=1, numCont=1, numTenants=4): # sanity checks if numVMs > 4: print("[ERROR] Currently, only 4 VM instances are available.") return False elif numCont > 2: print( "[ERROR] The number of possible OVS containers is limited by the number of available cores: 2 cores per l2fwd session, 2 sessions per OVS instance => limit=3" ) return False elif numCont % numVMs != 0: print( "[ERROR] Number of containers should be a multiple of number of VMs." ) return False elif numTenants % numCont != 0: print( "[ERROR] Number of Flow Rules has to be a multiple of the number of Containers." ) return False elif numVMs < 1 or numCont < 1: return False exp.isContainer = True cpuArray = exp.cpuAllocation(2, nbrCores, isIsolated, True, 2, l2fwdCpuCores, totalCpuCores) exp.isContainer = False exp.HOST_CPU = cpuArray["hostCpu"] OvsCpu = cpuArray["ovsCpu"] DpdkCpu = cpuArray["ovsDpdk"] cpuDpdkPorts = cpuArray["cpuDpdkPorts"] TenantVMsCpuArray = cpuArray["TenantVMsCpuArray"] OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"] num_vfs = str(numCont * 3) exp.NicConfig = ["1", num_vfs] exp.NicType = "mlx" exp.isSRIOV = True exp.Server_cnx = cnx_server exp.pf_index = 0 exp.pfs = [] exp.vfs = [] exp.scsName = "vm2vm_SRIOV_Dynamic_Container" + "_IsDPDK=" + str( isDPDK) + "_IsIsolated=" + str(isIsolated) logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S") # exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp) exp.Logs("", logTimeStamp) exp.IsDPDK = isDPDK if isDPDK: exp.OVS_PATH = exp.dpdk_path else: exp.OVS_PATH = exp.nodpdk_path exp.PhyPorts = [("enp2s0f0", num_vfs), ("enp2s0f1", num_vfs)] exp.InitialConfig() exp.isContainer = True port_1_Vfs = exp.pfs[0][2] port_2_Vfs = exp.pfs[1][2] exp.MyVfs = [] for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 print("[*] VM INDEX: " + str(vm_idx)) vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" print(" => VM : " + vm) exp.MyVfs.append((port_1_Vfs[i * 5], "0", "off", vm, i)) exp.MyVfs.append((port_2_Vfs[i * 5], "0", "off", vm, i)) for l in range(0, 2): vlan = str((i * 2 + l + 1) * 10) # tenant_vm = "tenant-green-{}".format(i*2 + l + 1) tenant_vm = "tenant-green-{}".format(l + 1) exp.MyVfs.append( (port_1_Vfs[i * 5 + l * 2 + 1], vlan, "off", vm, i)) exp.MyVfs.append( (port_2_Vfs[i * 5 + l * 2 + 1], vlan, "off", vm, i)) exp.MyVfs.append( (port_1_Vfs[i * 5 + l * 2 + 2], vlan, "off", tenant_vm)) exp.MyVfs.append( (port_2_Vfs[i * 5 + l * 2 + 2], vlan, "off", tenant_vm)) exp.usedVms = [("vswitch-vm-container", OvsVMsCpuArray[0], VmRam)] for i in range(1, numVMs): exp.usedVms.append(("vswitch-vm-container-{}".format(i + 1), OvsVMsCpuArray[i], VmRam)) for i in range(0, 2): exp.usedVms.append( ("tenant-green-{}".format(i + 1), TenantVMsCpuArray[i], str(2929688 * numCont))) if isDPDK: ovs_ports = [] for i in range(0, numCont): ovs_ports.append([(port_1_Vfs[i * 5], True, cpuDpdkPorts), (port_2_Vfs[i * 5], True, cpuDpdkPorts), (port_1_Vfs[i * 5 + 1], True, cpuDpdkPorts), (port_2_Vfs[i * 5 + 1], True, cpuDpdkPorts), (port_1_Vfs[i * 5 + 3], True, cpuDpdkPorts), (port_2_Vfs[i * 5 + 3], True, cpuDpdkPorts)]) else: ovs_ports = [] for i in range(0, numCont): ovs_ports.append([(port_1_Vfs[i * 5], False), (port_2_Vfs[i * 5], False), (port_1_Vfs[i * 5 + 1], False), (port_2_Vfs[i * 5 + 1], False), (port_1_Vfs[i * 5 + 3], False), (port_2_Vfs[i * 5 + 3], False)]) msg = exp.GetScenarioSummary([a for a in ovs_ports], OvsCpu, DpdkCpu, DpdkMem, isIsolated) # exp.EmailNotify(msg, "is beeing prepared", logTimeStamp) exp.Logs(msg, logTimeStamp) exp.Vfsconfig() if isDPDK: for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" exp.ConfigOVS(vm, "br0", ovs_ports[i], OvsCpu, DpdkMem, DpdkCpu, ContNum=i, VMNum=vm_idx) else: for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" exp.ConfigOVS(vm, "br0", ovs_ports[i], OvsCpu, ContNum=i, VMNum=vm_idx) for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" match = "in_port={},ip,nw_dst=10.0.0.{}".format( exp.VfsMatch[port_1_Vfs[i * 5]], (i + 1) * 2) action = "mod_dl_dst:{},{}".format( exp.GetMacByVf(port_1_Vfs[i * 5 + 2]), exp.VfsMatch[port_1_Vfs[i * 5 + 1]]) exp.addFlowRule(vm, exp.OVS_PATH, "br0", match, action) match = "in_port={}".format(exp.VfsMatch[port_2_Vfs[i * 5 + 1]]) action = "mod_dl_dst:{},{}".format( exp.GetMacByVf(port_1_Vfs[i * 5 + 4]), exp.VfsMatch[port_1_Vfs[i * 5 + 3]]) exp.addFlowRule(vm, exp.OVS_PATH, "br0", match, action) match = "in_port={}".format(exp.VfsMatch[port_2_Vfs[i * 5 + 3]]) action = "mod_dl_dst:{},{}".format(outDestMac, exp.VfsMatch[port_2_Vfs[i * 5]]) exp.addFlowRule(vm, exp.OVS_PATH, "br0", match, action) exp.showFlowRules(vm, exp.OVS_PATH, "br0") tenant = "tenant-green-{}".format(1) mac = exp.GetMacByVf(port_2_Vfs[i * 5 + 1]) exp.patchMAC(tenant, "./container/l2fwd-FourOvsVm-container-{}".format(i + 1), mac) tenant = "tenant-green-{}".format(2) mac = exp.GetMacByVf(port_2_Vfs[i * 5 + 3]) exp.patchMAC(tenant, "./container/l2fwd-FourOvsVm-container-{}".format(i + 1), mac) exp.startL2Frwd(numCont, vswitchMode="v2v_container", tenantCount=numCont) # exp.EmailNotify(msg, "is ready", logTimeStamp) return True
def phy2vm2vm2phy_SRIOV_Dynamic_Container(cnx_server, isDPDK, nbrCores, isIsolated, numVMs=1, numCont=1, numTenants=4): # sanity checks if numVMs > 4: print("[ERROR] Currently, only 4 VM instances are available.") return False elif numCont > 24: print( "[ERROR] The maximum number of configurable containers is 24 as the PF's totalvfs is 64." ) return False elif numCont % numVMs != 0: print( "[ERROR] Number of containers should be a multiple of number of VMs." ) return False elif numTenants % numCont != 0: print( "[ERROR] Number of Tenants has to be a multiple of the number of Containers." ) return False elif numVMs < 1 or numCont < 1: return False # 2 cores per l2fwd session, all running on one tenant VM exp.isContainer = True cpuArray = exp.cpuAllocation(numVMs, nbrCores, isIsolated, True, 1, l2fwdCpuCores, totalCpuCores) exp.isContainer = False exp.HOST_CPU = cpuArray["hostCpu"] OvsCpu = cpuArray["ovsCpu"] DpdkCpu = cpuArray["ovsDpdk"] cpuDpdkPorts = cpuArray["cpuDpdkPorts"] TenantVMsCpuArray = cpuArray["TenantVMsCpuArray"] OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"] # upper bound derived from p2v, results in same offsets for in/out ports num_vfs = str(numTenants * 2 + numCont) offset = int(num_vfs) / numCont exp.NicConfig = ["1", num_vfs] exp.NicType = "mlx" exp.isSRIOV = True exp.Server_cnx = cnx_server exp.pf_index = 0 exp.pfs = [] exp.vfs = [] exp.scsName = "phy2vm2vm2phy_SRIOV_Dynamic_Container" + "_IsDPDK=" + str( isDPDK) + "_IsIsolated=" + str(isIsolated) + "_numVMs=" + str( numVMs) + "_numCont=" + str(numCont) logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S") # exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp) exp.Logs("", logTimeStamp) exp.IsDPDK = isDPDK if isDPDK: # exp.OVS_PATH = exp.dpdk_path print("Container mode currently does not support DPDK.") return exp.PhyPorts = [("enp2s0f0", num_vfs), ("enp2s0f1", num_vfs)] exp.InitialConfig() # set isContainer only now to make sure that OvS is also stopped on the host (container stopping/cleaning is done in ConfigOVS) exp.isContainer = True port_1_Vfs = exp.pfs[0][2] port_2_Vfs = exp.pfs[1][2] exp.MyVfs = [] for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 print("[*] VM INDEX: " + str(vm_idx)) vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" tenant_vm = "tenant-green-1" print(" => VM : " + vm) # in/out VF per container exp.MyVfs.append((port_1_Vfs[i * offset], "0", "off", vm, i)) exp.MyVfs.append((port_2_Vfs[i * offset], "0", "off", vm, i)) for f in range(0, numTenants / numCont): vlan = str(((numTenants / numCont) * i + f + 1) * 10) # tenant specific gateway VFs exp.MyVfs.append( (port_1_Vfs[i * offset + f * 2 + 1], vlan, "off", vm, i)) exp.MyVfs.append( (port_2_Vfs[i * offset + f * 2 + 1], vlan, "off", vm, i)) exp.MyVfs.append( (port_1_Vfs[i * offset + f * 2 + 2], vlan, "off", tenant_vm)) exp.MyVfs.append( (port_2_Vfs[i * offset + f * 2 + 2], vlan, "off", tenant_vm)) exp.usedVms = [("vswitch-vm-container", OvsVMsCpuArray[0], VmRam)] for i in range(1, numVMs): exp.usedVms.append(("vswitch-vm-container-{}".format(i + 1), OvsVMsCpuArray[i], VmRam)) # allocate some base memory for the VM and 1GB + some overhead per tenant, as each l2fwd application needs at least one 1GB hugepage exp.usedVms.append(("tenant-green-{}".format(1), TenantVMsCpuArray[0], str(488281 + 1074219 * numTenants))) if isDPDK: return else: ovs_ports = [] for i in range(0, numCont): p = [(port_1_Vfs[i * offset], False), (port_2_Vfs[i * offset], False)] for f in range(0, numTenants / numCont): p.append((port_1_Vfs[i * offset + f * 2 + 1], False)) p.append((port_2_Vfs[i * offset + f * 2 + 1], False)) ovs_ports.append(p) msg = exp.GetScenarioSummary([a for a in ovs_ports], OvsCpu, DpdkCpu, DpdkMem, isIsolated) # exp.EmailNotify(msg, "is beeing prepared", logTimeStamp) exp.Logs(msg, logTimeStamp) exp.Vfsconfig() if isDPDK: return else: for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" exp.ConfigOVS(vm, "br0", ovs_ports[i], OvsCpu, ContNum=i, VMNum=vm_idx) # add flow rules for each container for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" for f in range(0, numTenants / numCont): match = "in_port={},ip,nw_dst=10.0.0.{}".format( exp.VfsMatch[port_1_Vfs[i * offset]], (numTenants / numCont) * i + f + 2) action = "mod_dl_dst:{},{}".format( exp.GetMacByVf(port_1_Vfs[i * offset + f * 2 + 2]), exp.VfsMatch[port_1_Vfs[i * offset + f * 2 + 1]]) exp.addFlowRule(vm, exp.OVS_PATH, "br0", match, action, ContNum=i) match = "in_port={}".format(exp.VfsMatch[port_2_Vfs[i * offset + f * 2 + 1]]) action = "mod_dl_dst:{},{}".format( outDestMac, exp.VfsMatch[port_2_Vfs[i * offset]]) exp.addFlowRule(vm, exp.OVS_PATH, "br0", match, action, ContNum=i) # adjust MAC address in l2fwd binary on tenant vm tenant = "tenant-green-1" mac = exp.GetMacByVf(port_2_Vfs[i * offset + f * 2 + 1]) exp.patchMAC( tenant, "./container/l2fwd-container-{}".format( (numTenants / numCont) * i + 1), mac) exp.showFlowRules(vm, exp.OVS_PATH, "br0", ContNum=i) exp.startL2Frwd(numCont, vswitchMode="p2v_container", tenantCount=numCont) print("[*] Offset: {}".format(offset)) print("[*] in/out MACs: ") for i in range(0, numCont): print(" Container ID: {}".format(i)) print(" IPs: 10.0.0.{}".format( range(i * (numTenants / numCont) + 2, (i + 1) * (numTenants / numCont) + 2))) print(" {}".format(exp.GetMacByVf(port_1_Vfs[i * offset]))) print(" {}".format(exp.GetMacByVf(port_2_Vfs[i * offset]))) # exp.EmailNotify(msg, "is ready", logTimeStamp) return True
def phy2phy_SRIOV_Dynamic_Container(cnx_server, isDPDK, nbrCores, isIsolated=False, numVMs=1, numCont=1, numTenants=4): # sanity checks if numVMs > 4: print("[ERROR] Currently, only 4 VM instances are available.") return False elif numCont > 64 // 3: print( "[ERROR] The maximum number of configurable containers is 21 as the PF's totalvfs is 64." ) # not correct return False elif numCont % numVMs != 0: print( "[ERROR] Number of containers should be a multiple of number of VMs." ) return False elif numTenants % numCont != 0: print( "[ERROR] Number of Flow Rules has to be a multiple of the number of Containers." ) return False elif numVMs < 1 or numCont < 1: return False cpuArray = exp.cpuAllocation(numVMs, nbrCores, isIsolated, True, totalTenantVMs, 2, totalCpuCores) exp.HOST_CPU = cpuArray["hostCpu"] OvsCpu = cpuArray["ovsCpu"] DpdkCpu = cpuArray["ovsDpdk"] cpuDpdkPorts = cpuArray["cpuDpdkPorts"] OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"] # upper bound derived from p2v, results in same offsets for in/out ports num_vfs = str(numTenants * 2 + numCont) offset = int(num_vfs) / numCont exp.NicConfig = ["1", num_vfs] exp.NicType = "mlx" exp.isSRIOV = True exp.Server_cnx = cnx_server exp.pf_index = 0 exp.pfs = [] exp.vfs = [] exp.scsName = "phy2phy_SRIOV_Dynamic_Container" + "_IsDPDK=" + str( isDPDK) + "_IsIsolated=" + str(isIsolated) + "_numVMs=" + str( numVMs) + "_numCont=" + str(numCont) logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S") # exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp) exp.Logs("", logTimeStamp) exp.isDPDK = isDPDK if isDPDK: # exp.OVS_PATH = exp.dpdk_path print("Container mode currently does not support DPDK.") return exp.PhyPorts = [("enp2s0f0", num_vfs), ("enp2s0f1", num_vfs)] exp.InitialConfig() # set isContainer only now to make sure that OvS is also stopped on the host (container stopping/cleaning is done in ConfigOVS) exp.isContainer = True port_1_Vfs = exp.pfs[0][2] port_2_Vfs = exp.pfs[1][2] exp.MyVfs = [] for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 print("[*] VM INDEX: " + str(vm_idx)) vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" print(" => VM : " + vm) exp.MyVfs.append((port_1_Vfs[i * offset], "0", "off", vm, i)) exp.MyVfs.append((port_2_Vfs[i * offset], "0", "off", vm, i)) exp.usedVms = [("vswitch-vm-container", OvsVMsCpuArray[0], VmRam)] for i in range(1, numVMs): exp.usedVms.append(("vswitch-vm-container-{}".format(i + 1), OvsVMsCpuArray[i], VmRam)) if isDPDK: pass else: ovs_ports = [] for i in range(0, numCont): ovs_ports.append([(port_1_Vfs[i * offset], False), (port_2_Vfs[i * offset], False)]) msg = exp.GetScenarioSummary([a for a in ovs_ports], OvsCpu, DpdkCpu, DpdkMem, isIsolated) # exp.EmailNotify(msg, "is beeing prepared", logTimeStamp) exp.Logs(msg, logTimeStamp) exp.Vfsconfig() if isDPDK: pass else: for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" exp.ConfigOVS(vm, "br0", ovs_ports[i], OvsCpu, ContNum=i, VMNum=vm_idx) # add flow rules for each container for i in range(0, numCont): vm_idx = int(float(i) / numCont * numVMs) + 1 vm = "vswitch-vm-container-{}".format( vm_idx) if vm_idx != 1 else "vswitch-vm-container" for f in range(0, numTenants / numCont): match = "in_port={},ip,nw_dst=10.0.0.{}".format( exp.VfsMatch[port_1_Vfs[i * offset]], (i * (numTenants / numCont)) + 2 + f) action = "mod_dl_dst:{},{}".format( outDestMac, exp.VfsMatch[port_2_Vfs[i * offset]]) exp.addFlowRule(vm, exp.OVS_PATH, "br0", match, action, ContNum=i) exp.showFlowRules(vm, exp.OVS_PATH, "br0", ContNum=i) print("[*] Offset: {}".format(offset)) print("[*] in/out MACs: ") for i in range(0, numCont): print(" Container ID: {}".format(i)) print(" IPs: 10.0.0.{}".format( range(i * (numTenants / numCont) + 2, (i + 1) * (numTenants / numCont) + 2))) print(" {}".format(exp.GetMacByVf(port_1_Vfs[i * offset]))) print(" {}".format(exp.GetMacByVf(port_2_Vfs[i * offset]))) # exp.EmailNotify(msg, "is ready", logTimeStamp) return True
def phy2phy_SRIOV_FourOvs(cnx_server, isDPDK, nbrCores, isIsolated): cpuArray = exp.cpuAllocation(4, nbrCores, isIsolated, True, totalTenantVMs, TenantVmCores, totalCpuCores) exp.HOST_CPU = cpuArray["hostCpu"] OvsCpu = cpuArray["ovsCpu"] DpdkCpu = cpuArray["ovsDpdk"] cpuDpdkPorts = cpuArray["cpuDpdkPorts"] OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"] exp.NicConfig = ["1", "12"] exp.NicType = "mlx" exp.isSRIOV = True exp.Server_cnx = cnx_server exp.pf_index = 0 exp.pfs = [] exp.vfs = [] exp.scsName = "phy2phy_SRIOV_FourOvs_IsDPDK=" + str( isDPDK) + "_IsIsolated=" + str(isIsolated) logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S") exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp) exp.Logs("", logTimeStamp) if isDPDK: exp.IsDPDK = True exp.OVS_PATH = exp.dpdk_path else: exp.IsDPDK = False exp.OVS_PATH = exp.nodpdk_path exp.PhyPorts = [("enp2s0f0", "12"), ("enp2s0f1", "12")] exp.InitialConfig() port_1_Vfs = exp.pfs[0][2] port_2_Vfs = exp.pfs[1][2] exp.MyVfs = [(port_1_Vfs[0], "0", "off", "vswitch-vm"), (port_2_Vfs[0], "0", "off", "vswitch-vm"), (port_1_Vfs[3], "0", "off", "vswitch-vm-2"), (port_2_Vfs[3], "0", "off", "vswitch-vm-2"), (port_1_Vfs[6], "0", "off", "vswitch-vm-3"), (port_2_Vfs[6], "0", "off", "vswitch-vm-3"), (port_1_Vfs[9], "0", "off", "vswitch-vm-4"), (port_2_Vfs[9], "0", "off", "vswitch-vm-4")] exp.usedVms = [("vswitch-vm", OvsVMsCpuArray[0], VmRam), ("vswitch-vm-2", OvsVMsCpuArray[1], VmRam), ("vswitch-vm-3", OvsVMsCpuArray[2], VmRam), ("vswitch-vm-4", OvsVMsCpuArray[3], VmRam)] if isDPDK: OvsVmPorts1 = [(port_1_Vfs[0], True, cpuDpdkPorts), (port_2_Vfs[0], True, cpuDpdkPorts)] OvsVmPorts2 = [(port_1_Vfs[3], True, cpuDpdkPorts), (port_2_Vfs[3], True, cpuDpdkPorts)] OvsVmPorts3 = [(port_1_Vfs[6], True, cpuDpdkPorts), (port_2_Vfs[6], True, cpuDpdkPorts)] OvsVmPorts4 = [(port_1_Vfs[9], True, cpuDpdkPorts), (port_2_Vfs[9], True, cpuDpdkPorts)] else: OvsVmPorts1 = [(port_1_Vfs[0], False), (port_2_Vfs[0], False)] OvsVmPorts2 = [(port_1_Vfs[3], False), (port_2_Vfs[3], False)] OvsVmPorts3 = [(port_1_Vfs[6], False), (port_2_Vfs[6], False)] OvsVmPorts4 = [(port_1_Vfs[9], False), (port_2_Vfs[9], False)] msg = exp.GetScenarioSummary( [OvsVmPorts1, OvsVmPorts2, OvsVmPorts3, OvsVmPorts4], OvsCpu, DpdkCpu, DpdkMem, isIsolated) exp.EmailNotify(msg, "is beeing prepared", logTimeStamp) exp.Logs(msg, logTimeStamp) exp.Vfsconfig() if isDPDK: exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu, DpdkMem, DpdkCpu) exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu, DpdkMem, DpdkCpu) exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu, DpdkMem, DpdkCpu) exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu, DpdkMem, DpdkCpu) else: exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu) exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu) exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu) exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu) ''' OVS Flow Rules for OVS-VM-1: Note that the VF offset (3) is chosen to be unnecessarily big in order to match in/out port assignment between p2p and p2v for the same number of OvS VMs/instances (same offsets -> same MACs -> same pcaps can be used for measurements) ''' #Flow Rules (1) match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.2" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm", exp.OVS_PATH, "br0") ''' OVS Flow Rules for OVS-VM-2: ''' #Flow Rules (3) match = "in_port=" + exp.VfsMatch[port_1_Vfs[3]] + ",ip,nw_dst=10.0.0.3" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[3]] exp.addFlowRule("vswitch-vm-2", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm-2", exp.OVS_PATH, "br0") ''' OVS Flow Rules for OVS-VM-3: ''' #Flow Rules (1) match = "in_port=" + exp.VfsMatch[port_1_Vfs[6]] + ",ip,nw_dst=10.0.0.4" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[6]] exp.addFlowRule("vswitch-vm-3", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm-3", exp.OVS_PATH, "br0") ''' OVS Flow Rules for OVS-VM-4: ''' #Flow Rules (3) match = "in_port=" + exp.VfsMatch[port_1_Vfs[9]] + ",ip,nw_dst=10.0.0.5" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[9]] exp.addFlowRule("vswitch-vm-4", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm-4", exp.OVS_PATH, "br0") exp.EmailNotify(msg, "is ready", logTimeStamp) return True
def phy2phy_SRIOV_OneOvs(cnx_server, isDPDK, nbrCores): cpuArray = exp.cpuAllocation(1, nbrCores, True, True, totalTenantVMs, TenantVmCores, totalCpuCores) exp.HOST_CPU = cpuArray["hostCpu"] OvsCpu = cpuArray["ovsCpu"] DpdkCpu = cpuArray["ovsDpdk"] cpuDpdkPorts = cpuArray["cpuDpdkPorts"] OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"] exp.NicConfig = ["1", "9"] exp.NicType = "mlx" exp.isSRIOV = True exp.Server_cnx = cnx_server exp.pf_index = 0 exp.pfs = [] exp.vfs = [] exp.scsName = "phy2phy_SRIOV_OneOvs_IsDPDK=" + str(isDPDK) logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S") # exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp) exp.Logs("", logTimeStamp) if isDPDK: exp.IsDPDK = True exp.OVS_PATH = exp.dpdk_path else: exp.IsDPDK = False exp.OVS_PATH = exp.nodpdk_path exp.PhyPorts = [("enp2s0f0", "9"), ("enp2s0f1", "9")] exp.InitialConfig() port_1_Vfs = exp.pfs[0][2] port_2_Vfs = exp.pfs[1][2] exp.MyVfs = [(port_1_Vfs[0], "0", "off", "vswitch-vm"), (port_2_Vfs[0], "0", "off", "vswitch-vm")] exp.usedVms = [("vswitch-vm", OvsVMsCpuArray[0], VmRam)] if isDPDK: OvsVmPorts1 = [(port_1_Vfs[0], True, cpuDpdkPorts), (port_2_Vfs[0], True, cpuDpdkPorts)] else: OvsVmPorts1 = [(port_1_Vfs[0], False), (port_2_Vfs[0], False)] msg = exp.GetScenarioSummary([OvsVmPorts1], OvsCpu, DpdkCpu, DpdkMem) # exp.EmailNotify(msg, "is beeing prepared", logTimeStamp) exp.Logs(msg, logTimeStamp) exp.Vfsconfig() if isDPDK: exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu, DpdkMem, DpdkCpu) else: exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu) ''' OVS Flow Rules for OVS-VM-1: ''' # Flow Rules (1) match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.2" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.3" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.4" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.5" action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm", exp.OVS_PATH, "br0") # exp.EmailNotify(msg, "is ready", logTimeStamp) return True
def phy2vm2vm2phy_SRIOV_FourOvs(cnx_server, isDPDK, nbrCores, isIsolated): cpuArray = exp.cpuAllocation(4, nbrCores, isIsolated, True, totalTenantVMs, TenantVmCores, totalCpuCores) exp.HOST_CPU = cpuArray["hostCpu"] OvsCpu = cpuArray["ovsCpu"] DpdkCpu = cpuArray["ovsDpdk"] cpuDpdkPorts = cpuArray["cpuDpdkPorts"] TenantVMsCpuArray = cpuArray["TenantVMsCpuArray"] OvsVMsCpuArray = cpuArray["OvsVMsCpuArray"] exp.NicConfig = ["1", "12"] exp.NicType = "mlx" exp.isSRIOV = True exp.Server_cnx = cnx_server exp.pf_index = 0 exp.pfs = [] exp.vfs = [] exp.scsName = "phy2vm2vm2phy_SRIOV_FourOvs_IsDPDK=" + str( isDPDK) + "_IsIsolated=" + str(isIsolated) logTimeStamp = datetime.now().strftime("%Y-%m-%d_%H-%M-%S") exp.EmailNotify(InitMessage, "is beeing prepared", logTimeStamp) exp.Logs("", logTimeStamp) if isDPDK: exp.IsDPDK = True exp.OVS_PATH = exp.dpdk_path else: exp.IsDPDK = False exp.OVS_PATH = exp.nodpdk_path exp.PhyPorts = [("enp2s0f0", "12"), ("enp2s0f1", "12")] exp.InitialConfig() port_1_Vfs = exp.pfs[0][2] port_2_Vfs = exp.pfs[1][2] exp.MyVfs = [(port_1_Vfs[0], "0", "off", "vswitch-vm"), (port_2_Vfs[0], "0", "off", "vswitch-vm"), (port_1_Vfs[1], "10", "off", "vswitch-vm"), (port_2_Vfs[1], "10", "off", "vswitch-vm"), (port_1_Vfs[2], "10", "off", "tenant-green-1"), (port_2_Vfs[2], "10", "off", "tenant-green-1"), (port_1_Vfs[3], "0", "off", "vswitch-vm-2"), (port_2_Vfs[3], "0", "off", "vswitch-vm-2"), (port_1_Vfs[4], "20", "off", "vswitch-vm-2"), (port_2_Vfs[4], "20", "off", "vswitch-vm-2"), (port_1_Vfs[5], "20", "off", "tenant-green-2"), (port_2_Vfs[5], "20", "off", "tenant-green-2"), (port_1_Vfs[6], "0", "off", "vswitch-vm-3"), (port_2_Vfs[6], "0", "off", "vswitch-vm-3"), (port_1_Vfs[7], "30", "off", "vswitch-vm-3"), (port_2_Vfs[7], "30", "off", "vswitch-vm-3"), (port_1_Vfs[8], "30", "off", "tenant-green-3"), (port_2_Vfs[8], "30", "off", "tenant-green-3"), (port_1_Vfs[9], "0", "off", "vswitch-vm-4"), (port_2_Vfs[9], "0", "off", "vswitch-vm-4"), (port_1_Vfs[10], "40", "off", "vswitch-vm-4"), (port_2_Vfs[10], "40", "off", "vswitch-vm-4"), (port_1_Vfs[11], "40", "off", "tenant-green-4"), (port_2_Vfs[11], "40", "off", "tenant-green-4")] exp.usedVms = [("vswitch-vm", OvsVMsCpuArray[0], VmRam), ("vswitch-vm-2", OvsVMsCpuArray[1], VmRam), ("vswitch-vm-3", OvsVMsCpuArray[2], VmRam), ("vswitch-vm-4", OvsVMsCpuArray[3], VmRam), ("tenant-green-1", TenantVMsCpuArray[0], VmRam), ("tenant-green-2", TenantVMsCpuArray[1], VmRam), ("tenant-green-3", TenantVMsCpuArray[2], VmRam), ("tenant-green-4", TenantVMsCpuArray[3], VmRam)] if isDPDK: OvsVmPorts1 = [(port_1_Vfs[0], True, cpuDpdkPorts), (port_2_Vfs[0], True, cpuDpdkPorts), (port_1_Vfs[1], True, cpuDpdkPorts), (port_2_Vfs[1], True, cpuDpdkPorts)] OvsVmPorts2 = [(port_1_Vfs[3], True, cpuDpdkPorts), (port_2_Vfs[3], True, cpuDpdkPorts), (port_1_Vfs[4], True, cpuDpdkPorts), (port_2_Vfs[4], True, cpuDpdkPorts)] OvsVmPorts3 = [(port_1_Vfs[6], True, cpuDpdkPorts), (port_2_Vfs[6], True, cpuDpdkPorts), (port_1_Vfs[7], True, cpuDpdkPorts), (port_2_Vfs[7], True, cpuDpdkPorts)] OvsVmPorts4 = [(port_1_Vfs[9], True, cpuDpdkPorts), (port_2_Vfs[9], True, cpuDpdkPorts), (port_1_Vfs[10], True, cpuDpdkPorts), (port_2_Vfs[10], True, cpuDpdkPorts)] else: OvsVmPorts1 = [(port_1_Vfs[0], False), (port_2_Vfs[0], False), (port_1_Vfs[1], False), (port_2_Vfs[1], False)] OvsVmPorts2 = [(port_1_Vfs[3], False), (port_2_Vfs[3], False), (port_1_Vfs[4], False), (port_2_Vfs[4], False)] OvsVmPorts3 = [(port_1_Vfs[6], False), (port_2_Vfs[6], False), (port_1_Vfs[7], False), (port_2_Vfs[7], False)] OvsVmPorts4 = [(port_1_Vfs[9], False), (port_2_Vfs[9], False), (port_1_Vfs[10], False), (port_2_Vfs[10], False)] msg = exp.GetScenarioSummary( [OvsVmPorts1, OvsVmPorts2, OvsVmPorts3, OvsVmPorts4], OvsCpu, DpdkCpu, DpdkMem, isIsolated) exp.EmailNotify(msg, "is beeing prepared", logTimeStamp) exp.Logs(msg, logTimeStamp) exp.Vfsconfig() if isDPDK: exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu, DpdkMem, DpdkCpu) exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu, DpdkMem, DpdkCpu) exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu, DpdkMem, DpdkCpu) exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu, DpdkMem, DpdkCpu) else: exp.ConfigOVS("vswitch-vm", "br0", OvsVmPorts1, OvsCpu) exp.ConfigOVS("vswitch-vm-2", "br0", OvsVmPorts2, OvsCpu) exp.ConfigOVS("vswitch-vm-3", "br0", OvsVmPorts3, OvsCpu) exp.ConfigOVS("vswitch-vm-4", "br0", OvsVmPorts4, OvsCpu) ''' OVS Flow Rules for OVS-VM-1: ''' # Flow Rules (1) match = "in_port=" + exp.VfsMatch[port_1_Vfs[0]] + ",ip,nw_dst=10.0.0.2" action = "mod_dl_dst:" + exp.GetMacByVf( port_1_Vfs[2]) + "," + exp.VfsMatch[port_1_Vfs[1]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) # Flow Rules (2) match = "in_port=" + exp.VfsMatch[port_2_Vfs[1]] action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[0]] exp.addFlowRule("vswitch-vm", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm", exp.OVS_PATH, "br0") ''' OVS Flow Rules for OVS-VM-2: ''' #Flow Rules (3) match = "in_port=" + exp.VfsMatch[port_1_Vfs[3]] + ",ip,nw_dst=10.0.0.3" action = "mod_dl_dst:" + exp.GetMacByVf( port_1_Vfs[5]) + "," + exp.VfsMatch[port_1_Vfs[4]] exp.addFlowRule("vswitch-vm-2", exp.OVS_PATH, "br0", match, action) #Flow Rules (4) match = "in_port=" + exp.VfsMatch[port_2_Vfs[4]] action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[3]] exp.addFlowRule("vswitch-vm-2", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm-2", exp.OVS_PATH, "br0") ''' OVS Flow Rules for OVS-VM-3: ''' #Flow Rules (1) match = "in_port=" + exp.VfsMatch[port_1_Vfs[6]] + ",ip,nw_dst=10.0.0.4" action = "mod_dl_dst:" + exp.GetMacByVf( port_1_Vfs[8]) + "," + exp.VfsMatch[port_1_Vfs[7]] exp.addFlowRule("vswitch-vm-3", exp.OVS_PATH, "br0", match, action) #Flow Rules (2) match = "in_port=" + exp.VfsMatch[port_2_Vfs[7]] action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[6]] exp.addFlowRule("vswitch-vm-3", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm-3", exp.OVS_PATH, "br0") ''' OVS Flow Rules for OVS-VM-4: ''' #Flow Rules (3) match = "in_port=" + exp.VfsMatch[port_1_Vfs[9]] + ",ip,nw_dst=10.0.0.5" action = "mod_dl_dst:" + exp.GetMacByVf( port_1_Vfs[11]) + "," + exp.VfsMatch[port_1_Vfs[10]] exp.addFlowRule("vswitch-vm-4", exp.OVS_PATH, "br0", match, action) #Flow Rules (4) match = "in_port=" + exp.VfsMatch[port_2_Vfs[10]] action = "mod_dl_dst:" + outDestMac + "," + exp.VfsMatch[port_2_Vfs[9]] exp.addFlowRule("vswitch-vm-4", exp.OVS_PATH, "br0", match, action) exp.showFlowRules("vswitch-vm-4", exp.OVS_PATH, "br0") exp.startL2Frwd(4) exp.EmailNotify(msg, "is ready", logTimeStamp) return True