def _get_extended_error_info(self): r'''_get_extended_error_info Returns detailed information about the last error that occurred in the current thread during a call to one of the NI-ModInst methods. When one of the other methods returns a negative value as its return value, immediately call this method to get detailed information about the error. Because error information is stored on a thread-by-thread basis, be sure to call this method in the same thread that called the method that returned an error. The extended error information is returned as a string. To find out the length of the error information string before you allocate a buffer for it, call this method and pass 0 as the errorInfoBufferSize parameter or NULL as the errorInfo parameter. When you do this, the method returns the size of the buffer required to hold the error information string as its return value. You can then allocate an appropriately sized string character buffer and call this method again. Returns: error_info (str): The character buffer into which the error information string is copied. ''' error_info_buffer_size_ctype = _visatype.ViInt32() # case S170 error_info_ctype = None # case C050 error_code = self._library.niModInst_GetExtendedErrorInfo(error_info_buffer_size_ctype, error_info_ctype) errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=True) error_info_buffer_size_ctype = _visatype.ViInt32(error_code) # case S180 error_info_ctype = (_visatype.ViChar * error_info_buffer_size_ctype.value)() # case C060 error_code = self._library.niModInst_GetExtendedErrorInfo(error_info_buffer_size_ctype, error_info_ctype) errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=True) return error_info_ctype.value.decode(self._encoding)
def _get_installed_device_attribute_vi_string(self, index, attribute_id): r'''_get_installed_device_attribute_vi_string Returns a string property specified by the attributeID parameter for a device specified by the handle and index parameters. The handle parameter is expected to be a valid handle returned by _open_installed_devices_session. Therefore, it acts as a handle to a list of installed devices. The index parameter specifies for which device in the list you want the property. To find out the length of the device name string before you allocate a buffer for it, simply call this method and pass 0 as the attributeValueBufferSize parameter or NULL as the attributeValue parameter. When you do this, the method returns the size of the buffer required to hold the property value string as its return value. You can then allocate an appropriately sized character buffer and call this method again. Args: index (int): A zero-based index that specifies the device for which you want the property. This index parameter should be between 0 and (deviceCount - 1), inclusive, where deviceCount is the number of installed devices returned by _open_installed_devices_session. attribute_id (int): The ID of the string property you want to query. Valid Values device_name--the name of the device, which can be used to open an instrument driver session for that device device_model--the model of the device (for example, NI PXI-5122) serial_number--the serial number of the device Returns: attribute_value (str): The character buffer into which the property value string is copied. ''' handle_ctype = _visatype.ViSession(self._handle) # case S110 index_ctype = _visatype.ViInt32(index) # case S150 attribute_id_ctype = _visatype.ViInt32(attribute_id) # case S150 attribute_value_buffer_size_ctype = _visatype.ViInt32() # case S170 attribute_value_ctype = None # case C050 error_code = self._library.niModInst_GetInstalledDeviceAttributeViString( handle_ctype, index_ctype, attribute_id_ctype, attribute_value_buffer_size_ctype, attribute_value_ctype) errors.handle_error(self, error_code, ignore_warnings=True, is_error_handling=False) attribute_value_buffer_size_ctype = _visatype.ViInt32( error_code) # case S180 attribute_value_ctype = ( _visatype.ViChar * attribute_value_buffer_size_ctype.value)() # case C060 error_code = self._library.niModInst_GetInstalledDeviceAttributeViString( handle_ctype, index_ctype, attribute_id_ctype, attribute_value_buffer_size_ctype, attribute_value_ctype) errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False) return attribute_value_ctype.value.decode(self._encoding)
def _get_installed_device_attribute_vi_int32(self, index, attribute_id): r'''_get_installed_device_attribute_vi_int32 Returns an integer property specified by the attributeID parameter for a device specified by the handle and index parameters. The handle parameter is expected to be a valid handle returned by _open_installed_devices_session. It therefore acts as a handle to a list of installed devices. The index parameter specifies the device in the list for which you want the property. Args: index (int): A zero-based index that specifies the device for which you want the property. This index parameter should be between 0 and (deviceCount - 1), inclusive, where deviceCount is the number of installed devices returned by _open_installed_devices_session. attribute_id (int): The ID of the integer property you want to query. Valid Values Slot Number--the slot (for example, in a PXI chassis) in which the device is installed. This property can only be queried for PXI devices installed in a chassis that has been properly identified in MAX. Chassis Number--the number of the chassis in which the device is installed. This property can only be queried for PXI devices installed in a chassis that has been properly identified in MAX. Bus Number--the bus on which the device has been enumerated. Socket Number--the socket number on which the device has been enumerated. Notes The bus number and socket number can be used to form a VISA resource string for this device, of the form "PXI::::INSTR". Traditional NI-DAQ devices do not support the chassis number, bus number, and socket number properties. Returns: attribute_value (int): A pointer to a signed 32-bit integer variable that receives the value of the requested property. ''' handle_ctype = _visatype.ViSession(self._handle) # case S110 index_ctype = _visatype.ViInt32(index) # case S150 attribute_id_ctype = _visatype.ViInt32(attribute_id) # case S150 attribute_value_ctype = _visatype.ViInt32() # case S220 error_code = self._library.niModInst_GetInstalledDeviceAttributeViInt32( handle_ctype, index_ctype, attribute_id_ctype, None if attribute_value_ctype is None else (ctypes.pointer(attribute_value_ctype))) errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False) return int(attribute_value_ctype.value)
def _get_error_description(self, error_code): '''_get_error_description Returns the error description. ''' # We hand-maintain the code that calls into self._library rather than leverage code-generation # because niModInst_GetExtendedErrorInfo() does not properly do the IVI-dance. # See https://github.com/ni/nimi-python/issues/166 error_info_buffer_size_ctype = _visatype.ViInt32() # case S170 error_info_ctype = None # case C050 error_code = self._library.niModInst_GetExtendedErrorInfo(error_info_buffer_size_ctype, error_info_ctype) if error_code <= 0: return "Failed to retrieve error description." error_info_buffer_size_ctype = _visatype.ViInt32(error_code) # case S180 error_info_ctype = (_visatype.ViChar * error_info_buffer_size_ctype.value)() # case C060 # Note we don't look at the return value. This is intentional as niModInst returns the # original error code rather than 0 (VI_SUCCESS). self._library.niModInst_GetExtendedErrorInfo(error_info_buffer_size_ctype, error_info_ctype) return error_info_ctype.value.decode("ascii")
def _open_installed_devices_session(self, driver): r'''_open_installed_devices_session Creates a handle to a list of installed devices supported by the specified driver. Call this method and pass in the name of an NI instrument driver, such as "NI-SCOPE". This method searches the system and constructs a list of all the installed devices that are supported by that driver, and then returns both a handle to this list and the number of devices found. The handle is used with other methods to query for properties such as device name and model, and to safely discard the list when finished. Note This handle reflects the system state when the handle is created (that is, when you call this method. If you remove devices from the system or rename them in Measurement & Automation Explorer (MAX), this handle may not refer to an accurate list of devices. You should destroy the handle using _close_installed_devices_session and create a new handle using this method. Args: driver (str): A string specifying the driver whose supported devices you want to find. This string is not case-sensitive. Some examples are: NI-SCOPE niScope NI-FGEN niFgen NI-HSDIO niHSDIO NI-DMM niDMM NI-SWITCH niSwitch Note If you use the empty string for this parameter, NI-ModInst creates a list of all Modular Instruments devices installed in the system. Returns: handle (int): A pointer to a ViSession variable that receives the value of the NI-ModInst session handle. This value acts as a handle to the list of installed devices and is used in other NI-ModInst methods. device_count (int): A pointer to an integer variable that receives the number of devices found in the system that are supported by the driver specified in the driver parameter. ''' driver_ctype = ctypes.create_string_buffer( driver.encode(self._encoding)) # case C020 handle_ctype = _visatype.ViSession() # case S220 device_count_ctype = _visatype.ViInt32() # case S220 error_code = self._library.niModInst_OpenInstalledDevicesSession( driver_ctype, None if handle_ctype is None else (ctypes.pointer(handle_ctype)), None if device_count_ctype is None else (ctypes.pointer(device_count_ctype))) errors.handle_error(self, error_code, ignore_warnings=False, is_error_handling=False) return int(handle_ctype.value), int(device_count_ctype.value)