def testPubSubStaticConf(): logger = TapLogger("pubsub_server_test.tap") pubsubserver = PubSubServer(DEFAULT_URI, NID_CONFIGURATION, NID_START_STOP, NID_STATUS) defaultXml2Restore = False try: # secure channel connection pubsubserver.connect() # # TC 1 : Test with Static Publisher and Subscriber configuration => subscriber variables change through Pub/Sub # logger.begin_section("TC 1 : Subscriber variables change through Pub/Sub") # Set Publisher variables and test change in Subscriber variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT, 8500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger) sleep(STATIC_CONF_PUB_INTERVAL) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT)) logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT)) # Set Publisher variables and test change in Subscriber variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT, 5800, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -30, logger) sleep(STATIC_CONF_PUB_INTERVAL) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint is changed ', 5800 == pubsubserver.getValue(NID_SUB_UINT)) logger.add_test('Subscriber int is changed ', -30 == pubsubserver.getValue(NID_SUB_INT)) # # TC 2 : Pub-Sub server is stopped => no change in Subscriber variables # logger.begin_section("TC 2 : Pub-Sub server is stopped") pubsubserver.stop() logger.add_test('PubSub Module is stopped' , not pubsubserver.isStart()) helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT, 7777, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, 123654, logger) sleep(STATIC_CONF_PUB_INTERVAL) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint is changed ', 5800 == pubsubserver.getValue(NID_SUB_UINT)) logger.add_test('Subscriber int is changed ', -30 == pubsubserver.getValue(NID_SUB_INT)) # # TC 3 : Pub-Sub server is restarted => Subscriber variables changed # logger.begin_section("TC 3 : Pub-Sub server is restarted") pubsubserver.start() logger.add_test('PubSub Module is started' , pubsubserver.isStart()) sleep(STATIC_CONF_PUB_INTERVAL) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint is changed ', 7777 == pubsubserver.getValue(NID_SUB_UINT)) logger.add_test('Subscriber int is changed ', 123654 == pubsubserver.getValue(NID_SUB_INT)) # # TC 4 : Change Pub-Sub server configuration => configuration cannot be changed in static mode # logger.begin_section("TC 4 : Change Pub-Sub server configuration") # Change Pub-Sub configuration node and check file is not change helpConfigurationChangeAndStart(pubsubserver, XML_SUBSCRIBER_ONLY, logger, static=True) # Check Pub-Sub module is still running helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT, 1245, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, 9874, logger) sleep(STATIC_CONF_PUB_INTERVAL) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint is changed ', 1245 == pubsubserver.getValue(NID_SUB_UINT)) logger.add_test('Subscriber int is changed ', 9874 == pubsubserver.getValue(NID_SUB_INT)) finally: pubsubserver.disconnect() logger.add_test('Not connected to OPCUA Server', not pubsubserver.isConnected()) logger.finalize_report()
translate_browse_paths_to_node_ids_tests(client, logger) finally: client.disconnect() print('Disconnected') # tests with several connexions headerString = "******************* Beginning {0} tests with several connexions *********************" client2 = create_client() for sp in [SecurityPolicy, security_policies.SecurityPolicyBasic256]: logger.begin_section("security policy {0}".format( re.split("#", sp.URI)[-1])) try: # secure channel connection secure_channels_connect(client, sp) secure_channels_connect(client2, sp) # Read/Write tests print(headerString.format("Read/Write")) attribute_write_values_two_clients_tests(client, client2, logger) finally: client.disconnect() client2.disconnect() print('Disconnected') logger.finalize_report() sys.exit(1 if logger.has_failed_tests else 0)
def testPubSubDynamicConf(): logger = TapLogger("pubsub_server_test.tap") pubsubserver = PubSubServer(DEFAULT_URI, NID_CONFIGURATION, NID_START_STOP, NID_STATUS) defaultXml2Restore = False try: # backup of default XML file copyfile(DEFAULT_XML_PATH, DEFAULT_XML_PATH + ".bakup") defaultXml2Restore = True # secure channel connection pubsubserver.connect() # # TC 1 : Test with Publisher only configuration => only pub variables change # logger.begin_section("TC 1 : Publisher only") helpConfigurationChangeAndStart(pubsubserver, XML_PUBLISHER_ONLY, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) # Set Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 1500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -50, logger) sleep(DYN_CONF_PUB_INTERVAL_1000) logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 2 : Test with Subscriber only configuration => no variables change # logger.begin_section("TC 2 : Subscriber only") # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpConfigurationChangeAndStart(pubsubserver, XML_SUBSCRIBER_ONLY, logger) sleep(DYN_CONF_PUB_INTERVAL_1000) logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 3 : Test with Publisher and Subscriber configuration => subscriber variables change through Pub/Sub # logger.begin_section("TC 3 : Publisher Subscriber Loop") # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -50 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 4 : Stop Pub/Sub module => subscriber variables do not change # logger.begin_section("TC 4 : Publisher Subscriber Loop") # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', -50 == pubsubserver.getValue(NID_SUB_INT)) # Start to change Subscriber variables pubsubserver.start() helpTestStopStart(pubsubserver, True, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 6500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -600 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 5 : Test with Publisher and Subscriber configuration. DataType is NULL # => subscriber variables change through Pub/Sub # logger.begin_section("TC 5 : Publisher Subscriber Loop (DataType is Null)") # Init Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 8500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_NULL, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 6 : Test with Publisher and Subscriber configuration => subscriber variables change through Pub/Sub # logger.begin_section("TC 6 : Test with Publisher and Subscriber configuration (MQTT) => subscriber variables change through Pub/Sub") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_MQTT, logger) sleep(DYN_CONF_PUB_INTERVAL_1000) # Init Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 8500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger) helpTestSetValue(pubsubserver, NID_PUB_STRING, "Test MQTT From Publisher", logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpTestSetValue(pubsubserver, NID_SUB_STRING, "Test MQTT Not set", logger) sleep(DYN_CONF_PUB_INTERVAL_1000) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT)) logger.add_test('Subscriber string is changed ', "Test MQTT From Publisher" == pubsubserver.getValue(NID_SUB_STRING)) sleep(DYN_CONF_PUB_INTERVAL_1000) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 7 : Test with configuration message not consistent between the one on Publisher # and the one on Subscriber => subscriber variables do not change # logger.begin_section("TC 7 : Publisher Subscriber not consistent") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_MESSAGE_NOT_COMPATIBLE, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT)) # # TC 8 : Test with a bad formed configuration => Pub/Sub status is 0 # logger.begin_section("TC 8 : Bad formed configuration") helpConfigurationChange(pubsubserver, XML_PUBSUB_BAD_FORMED_CONFIGURATION, logger) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) logger.add_test('Start Server', True) pubsubserver.start() status = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status) # # TC 9 : Start and Stop empty configuration # logger.begin_section("TC 9 : Empty configuration") helpConfigurationChange(pubsubserver, XML_EMPTY, logger) status = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status) # # TC 10 : Test with message configured with security mode encrypt and sign for publisher # but no security for subscriber => subscriber variables do not change # logger.begin_section("TC 10 : Security mode not consistent - message is encrypt and sign but no security for subscriber") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_FAIL_1, logger, possibleFail=True) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT)) expStatus = 3 # Error state retrievedStatus = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus) # # TC 11 : Test with message configured with security mode encrypt and sign for publisher # but only sign for subscriber => subscriber variables do not change # logger.begin_section("TC 11 : Security mode not consistent - message is encrypt and sign but only sign mode for subscriber") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_FAIL_2, logger, possibleFail=True) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT)) expStatus = 3 # Error state retrievedStatus = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus) # # TC 12 : Test with message configured with security mode sign for publisher # but encrypt and sign for subscriber => subscriber variables do not change # logger.begin_section("TC 12 : Security mode not consistent - message is sign but sign and encrypt for subscriber") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_FAIL_3, logger, possibleFail=True) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT)) expStatus = 3 # Error state retrievedStatus = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus) # # TC 13 : Test with message configured with security mode sign and encrypt # for both publisher and subscriber => subscriber variables change # logger.begin_section("TC 13 : Security mode sign and encrypt") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_ENCRYPT_SIGN_SUCCEED, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 852, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, 2658, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 852 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', 2658 == pubsubserver.getValue(NID_SUB_INT)) # # TC 14 : Test with message configured with security mode sign # for both publisher and subscriber => subscriber variables change # logger.begin_section("TC 14 : Security mode sign") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_SIGN_SUCCEED, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 528, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, 7896, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 528 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', 7896 == pubsubserver.getValue(NID_SUB_INT)) # # TC 15 : Test with message configured with security mode sign only # for publisher => subscriber variables do not change # logger.begin_section("TC 15 : Security mode sign only publisher") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_SIGN_FAIL_4, logger, possibleFail=True) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 456, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, 789, logger) sleep(DYN_CONF_PUB_INTERVAL_200) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT)) expStatus = 3 # Error state retrievedStatus = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus) finally: # restore default XML file if defaultXml2Restore: move(DEFAULT_XML_PATH + ".bakup", DEFAULT_XML_PATH) pubsubserver.disconnect() logger.add_test('Not connected to OPCUA Server', not pubsubserver.isConnected()) logger.finalize_report()
def testPubSubDynamicConf(): logger = TapLogger("pubsub_server_test.tap") pubsubserver = PubSubServer(DEFAULT_URI, NID_CONFIGURATION, NID_START_STOP, NID_STATUS) defaultXml2Restore = False try: # backup of default XML file copyfile(DEFAULT_XML_PATH, DEFAULT_XML_PATH + ".bakup") defaultXml2Restore = True # secure channel connection pubsubserver.connect() # # TC 1 : Test with Publisher only configuration => only pub variables change # logger.begin_section("TC 1 : Publisher only") helpConfigurationChangeAndStart(pubsubserver, XML_PUBLISHER_ONLY, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) # Set Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 1500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -50, logger) sleep(.400) logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 2 : Test with Subscriber only configuration => no variables change # logger.begin_section("TC 2 : Subscriber only") # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpConfigurationChangeAndStart(pubsubserver, XML_SUBSCRIBER_ONLY, logger) sleep(.400) logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 3 : Test with Publisher and Subscriber configuration => subscriber variables change through Pub/Sub # logger.begin_section("TC 3 : Publisher Subscriber Loop") # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP, logger) sleep(.400) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -50 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 4 : Stop Pub/Sub module => subscriber variables do not change # logger.begin_section("TC 4 : Publisher Subscriber Loop") # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(.400) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', -50 == pubsubserver.getValue(NID_SUB_INT)) # Start to change Subscriber variables pubsubserver.start() helpTestStopStart(pubsubserver, True, logger) sleep(.400) logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 6500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -600 == pubsubserver.getValue(NID_SUB_INT)) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) # # TC 5 : Test with Publisher and Subscriber configuration. DataType is NULL # => subscriber variables change through Pub/Sub # logger.begin_section("TC 5 : Publisher Subscriber Loop (DataType is Null)") # Init Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 8500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_NULL, logger) sleep(.400) logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT)) # # TC 6 : Test with configuration message not consistent between the one on Publisher # and the one on Subscriber => subscriber variables do not change # logger.begin_section("TC 6 : Publisher Subscriber not consistent") helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_MESSAGE_NOT_COMPATIBLE, logger) # Init Subscriber variables helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger) helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger) helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger) # Change Publisher variables helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger) helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger) helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger) sleep(.400) logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL)) logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16)) logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT)) # # TC 7 : Test with a bad formed configuration => Pub/Sub status is 0 # logger.begin_section("TC 7 : Bad formed configuration") helpConfigurationChange(pubsubserver, XML_PUBSUB_BAD_FORMED_CONFIGURATION, logger) pubsubserver.stop() helpTestStopStart(pubsubserver, False, logger) logger.add_test('Start Server', True) pubsubserver.start() status = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status) # # TC 8 : Start and Stop empty configuration # logger.begin_section("TC 8 : Empty configuration") helpConfigurationChange(pubsubserver, XML_EMPTY, logger) status = pubsubserver.getStatus() logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status) finally: # restore default XML file if defaultXml2Restore: move(DEFAULT_XML_PATH + ".bakup", DEFAULT_XML_PATH) pubsubserver.disconnect() logger.add_test('Not connected to OPCUA Server', not pubsubserver.isConnected()) logger.finalize_report()