def stop_metrics_process():

    if telhandler.is_running(is_lad=False):
        #Stop the telegraf and ME services
        tel_out, tel_msg = telhandler.stop_telegraf_service(is_lad=False)
        if tel_out:
            HUtilObject.log(tel_msg)
        else:
            HUtilObject.error(tel_msg)

        #Delete the telegraf and ME services
        tel_rm_out, tel_rm_msg = telhandler.remove_telegraf_service()
        if tel_rm_out:
            HUtilObject.log(tel_rm_msg)
        else:
            HUtilObject.error(tel_rm_msg)

    if me_handler.is_running(is_lad=False):
        me_out, me_msg = me_handler.stop_metrics_service(is_lad=False)
        if me_out:
            HUtilObject.log(me_msg)
        else:
            HUtilObject.error(me_msg)

        me_rm_out, me_rm_msg = me_handler.remove_metrics_service(is_lad=False)
        if me_rm_out:
            HUtilObject.log(me_rm_msg)
        else:
            HUtilObject.error(me_rm_msg)

    pids_filepath = os.path.join(os.getcwd(), 'amametrics.pid')

    # kill existing telemetry watcher
    if os.path.exists(pids_filepath):
        with open(pids_filepath, "r") as f:
            for pids in f.readlines():
                kill_cmd = "kill " + pids
                run_command_and_log(kill_cmd)
                run_command_and_log("rm " + pids_filepath)
def metrics_watcher(hutil_error, hutil_log):
    """
    Watcher thread to monitor metric configuration changes and to take action on them
    """

    # check every 30 seconds
    sleepTime = 30

    # sleep before starting the monitoring.
    time.sleep(sleepTime)
    last_crc = None
    me_msi_token_expiry_epoch = None

    while True:
        try:
            if os.path.isfile(MdsdCounterJsonPath):
                f = open(MdsdCounterJsonPath, "r")
                data = f.read()

                if (data != ''):
                    crc = hashlib.sha256(data).hexdigest()
                    generate_token = False
                    me_token_path = os.path.join(
                        os.getcwd(),
                        "/config/metrics_configs/AuthToken-MSI.json")

                    if me_msi_token_expiry_epoch is None or me_msi_token_expiry_epoch == "":
                        if os.path.isfile(me_token_path):
                            with open(me_token_path, "r") as f:
                                authtoken_content = f.read()
                                if authtoken_content and "expires_on" in authtoken_content:
                                    me_msi_token_expiry_epoch = authtoken_content[
                                        "expires_on"]
                                else:
                                    generate_token = True
                        else:
                            generate_token = True

                    if me_msi_token_expiry_epoch:
                        currentTime = datetime.datetime.now()
                        token_expiry_time = datetime.datetime.fromtimestamp(
                            int(me_msi_token_expiry_epoch))
                        if token_expiry_time - currentTime < datetime.timedelta(
                                minutes=30):
                            # The MSI Token will expire within 30 minutes. We need to refresh the token
                            generate_token = True

                    if generate_token:
                        generate_token = False
                        msi_token_generated, me_msi_token_expiry_epoch, log_messages = me_handler.generate_MSI_token(
                        )
                        if msi_token_generated:
                            hutil_log(
                                "Successfully refreshed metrics-extension MSI Auth token."
                            )
                        else:
                            hutil_error(log_messages)

                    if (crc != last_crc):
                        hutil_log("Start processing metric configuration")
                        hutil_log(data)

                        json_data = json.loads(data)

                        telegraf_config, telegraf_namespaces = telhandler.handle_config(
                            json_data,
                            "udp://127.0.0.1:" +
                            metrics_constants.ama_metrics_extension_udp_port,
                            "unix:///var/run/mdsd/default_influx.socket",
                            is_lad=False)

                        me_handler.setup_me(is_lad=False)

                        start_telegraf_out, log_messages = telhandler.start_telegraf(
                            is_lad=False)
                        if start_telegraf_out:
                            hutil_log("Successfully started metrics-sourcer.")
                        else:
                            hutil_error(log_messages)

                        start_metrics_out, log_messages = me_handler.start_metrics(
                            is_lad=False)
                        if start_metrics_out:
                            hutil_log(
                                "Successfully started metrics-extension.")
                        else:
                            hutil_error(log_messages)

                        last_crc = crc

                    telegraf_restart_retries = 0
                    me_restart_retries = 0
                    max_restart_retries = 10

                    # Check if telegraf is running, if not, then restart
                    if not telhandler.is_running(is_lad=False):
                        if telegraf_restart_retries < max_restart_retries:
                            telegraf_restart_retries += 1
                            hutil_log(
                                "Telegraf binary process is not running. Restarting telegraf now. Retry count - {0}"
                                .format(telegraf_restart_retries))
                            tel_out, tel_msg = telhandler.stop_telegraf_service(
                                is_lad=False)
                            if tel_out:
                                hutil_log(tel_msg)
                            else:
                                hutil_error(tel_msg)
                            start_telegraf_out, log_messages = telhandler.start_telegraf(
                                is_lad=False)
                            if start_telegraf_out:
                                hutil_log(
                                    "Successfully started metrics-sourcer.")
                            else:
                                hutil_error(log_messages)
                        else:
                            hutil_error(
                                "Telegraf binary process is not running. Failed to restart after {0} retries. Please check telegraf.log"
                                .format(max_restart_retries))
                    else:
                        telegraf_restart_retries = 0

                    # Check if ME is running, if not, then restart
                    if not me_handler.is_running(is_lad=False):
                        if me_restart_retries < max_restart_retries:
                            me_restart_retries += 1
                            hutil_log(
                                "MetricsExtension binary process is not running. Restarting MetricsExtension now. Retry count - {0}"
                                .format(me_restart_retries))
                            me_out, me_msg = me_handler.stop_metrics_service(
                                is_lad=False)
                            if me_out:
                                hutil_log(me_msg)
                            else:
                                hutil_error(me_msg)
                            start_metrics_out, log_messages = me_handler.start_metrics(
                                is_lad=False)

                            if start_metrics_out:
                                hutil_log(
                                    "Successfully started metrics-extension.")
                            else:
                                hutil_error(log_messages)
                        else:
                            hutil_error(
                                "MetricsExtension binary process is not running. Failed to restart after {0} retries. Please check /var/log/syslog for ME logs"
                                .format(max_restart_retries))
                    else:
                        me_restart_retries = 0

        except IOError as e:
            hutil_error(
                'I/O error in monitoring metrics. Exception={0}'.format(e))

        except Exception as e:
            hutil_error('Error in monitoring metrics. Exception={0}'.format(e))

        finally:
            time.sleep(sleepTime)
Exemple #3
0
def start_mdsd(configurator):
    """
    Start mdsd and monitor its activities. Report if it crashes or emits error logs.
    :param configurator: A valid LadConfigAll object that was obtained by create_core_components_config().
                         This will be used for configuring rsyslog/syslog-ng/fluentd/in_syslog/out_mdsd components
    :return: None
    """
    # This must be done first, so that extension enable completion doesn't get delayed.
    write_lad_pids_to_file(g_lad_pids_filepath, os.getpid())

    # Need 'HeartBeat' instead of 'Daemon'
    waagent_ext_event_type = wala_event_type_for_telemetry(g_ext_op_type)

    # mdsd http proxy setting
    proxy_config = get_mdsd_proxy_config(waagent.HttpProxyConfigString,
                                         g_ext_settings, hutil.log)
    if proxy_config:
        # Add MDSD_http_proxy to current environment. Child processes will inherit its value.
        os.environ['MDSD_http_proxy'] = proxy_config

    copy_env = os.environ.copy()
    # Add MDSD_CONFIG_DIR as an env variable since new mdsd master branch LAD doesnt create this dir
    mdsd_config_cache_dir = os.path.join(g_ext_dir, "config")
    copy_env["MDSD_CONFIG_DIR"] = mdsd_config_cache_dir

    # We then validate the mdsd config and proceed only when it succeeds.
    xml_file = os.path.join(g_ext_dir, 'xmlCfg.xml')
    tmp_env_dict = {
    }  # Need to get the additionally needed env vars (SSL_CERT_*) for this mdsd run as well...
    g_dist_config.extend_environment(tmp_env_dict)
    added_env_str = ' '.join('{0}={1}'.format(k, tmp_env_dict[k])
                             for k in tmp_env_dict)
    config_validate_cmd = '{0}{1}{2} -v -c {3} -r {4}'.format(
        added_env_str, ' ' if added_env_str else '', g_mdsd_bin_path, xml_file,
        g_ext_dir)
    config_validate_cmd_status, config_validate_cmd_msg = RunGetOutput(
        config_validate_cmd)
    if config_validate_cmd_status is not 0:
        # Invalid config. Log error and report success.
        g_lad_log_helper.log_and_report_invalid_mdsd_cfg(
            g_ext_op_type, config_validate_cmd_msg,
            read_file_to_string(xml_file))
        return

    # Start OMI if it's not running.
    # This shouldn't happen, but this measure is put in place just in case (e.g., Ubuntu 16.04 systemd).
    # Don't check if starting succeeded, as it'll be done in the loop below anyway.
    omi_running = RunGetOutput("/opt/omi/bin/service_control is-running",
                               should_log=False)[0] is 1
    if not omi_running:
        hutil.log("OMI is not running. Restarting it.")
        RunGetOutput("/opt/omi/bin/service_control restart")

    log_dir = hutil.get_log_dir()
    err_file_path = os.path.join(log_dir, 'mdsd.err')
    info_file_path = os.path.join(log_dir, 'mdsd.info')
    warn_file_path = os.path.join(log_dir, 'mdsd.warn')
    # Need to provide EH events and Rsyslog spool path since the new mdsd master branch LAD doesnt create the directory needed
    eh_spool_path = os.path.join(log_dir, 'eh')

    update_selinux_settings_for_rsyslogomazuremds(RunGetOutput, g_ext_dir)

    mdsd_stdout_redirect_path = os.path.join(g_ext_dir, "mdsd.log")
    mdsd_stdout_stream = None

    g_dist_config.extend_environment(copy_env)

    # Now prepare actual mdsd cmdline.
    command = '{0} -A -C -c {1} -R -r {2} -e {3} -w {4} -S {7} -o {5}{6}'.format(
        g_mdsd_bin_path, xml_file, g_mdsd_role_name,
        err_file_path, warn_file_path, info_file_path,
        g_ext_settings.get_mdsd_trace_option(), eh_spool_path).split(" ")

    try:
        start_watcher_thread()

        num_quick_consecutive_crashes = 0
        mdsd_crash_msg = ''

        while num_quick_consecutive_crashes < 3:  # We consider only quick & consecutive crashes for retries

            RunGetOutput('rm -f ' + g_mdsd_file_resources_prefix +
                         '.pidport')  # Must delete any existing port num file
            mdsd_stdout_stream = open(mdsd_stdout_redirect_path, "w")
            hutil.log("Start mdsd " + str(command))
            mdsd = subprocess.Popen(command,
                                    cwd=g_ext_dir,
                                    stdout=mdsd_stdout_stream,
                                    stderr=mdsd_stdout_stream,
                                    env=copy_env)

            write_lad_pids_to_file(g_lad_pids_filepath, os.getpid(), mdsd.pid)

            last_mdsd_start_time = datetime.datetime.now()
            last_error_time = last_mdsd_start_time
            omi_installed = True  # Remembers if OMI is installed at each iteration
            telegraf_restart_retries = 0
            me_restart_retries = 0
            max_restart_retries = 10
            # Continuously monitors mdsd process
            while True:
                time.sleep(30)
                if " ".join(get_lad_pids()).find(str(mdsd.pid)) < 0 and len(
                        get_lad_pids()) >= 2:
                    mdsd.kill()
                    hutil.log("Another process is started, now exit")
                    return
                if mdsd.poll() is not None:  # if mdsd has terminated
                    time.sleep(60)
                    mdsd_stdout_stream.flush()
                    break

                # mdsd is now up for at least 30 seconds. Do some monitoring activities.
                # 1. Mitigate if memory leak is suspected.
                mdsd_memory_leak_suspected, mdsd_memory_usage_in_KB = check_suspected_memory_leak(
                    mdsd.pid, hutil.error)
                if mdsd_memory_leak_suspected:
                    g_lad_log_helper.log_suspected_memory_leak_and_kill_mdsd(
                        mdsd_memory_usage_in_KB, mdsd, waagent_ext_event_type)
                    break
                # 2. Restart OMI if it crashed (Issue #128)
                omi_installed = restart_omi_if_crashed(omi_installed, mdsd)
                # 3. Check if there's any new logs in mdsd.err and report
                last_error_time = report_new_mdsd_errors(
                    err_file_path, last_error_time)
                # 4. Check if telegraf is running, if not, then restart
                if not telhandler.is_running(is_lad=True):
                    if telegraf_restart_retries < max_restart_retries:
                        telegraf_restart_retries += 1
                        hutil.log(
                            "Telegraf binary process is not running. Restarting telegraf now. Retry count - {0}"
                            .format(telegraf_restart_retries))
                        tel_out, tel_msg = telhandler.stop_telegraf_service(
                            is_lad=True)
                        if tel_out:
                            hutil.log(tel_msg)
                        else:
                            hutil.error(tel_msg)
                        start_telegraf_out, log_messages = telhandler.start_telegraf(
                            is_lad=True)
                        if start_telegraf_out:
                            hutil.log("Successfully started metrics-sourcer.")
                        else:
                            hutil.error(log_messages)
                    else:
                        hutil.error(
                            "Telegraf binary process is not running. Failed to restart after {0} retries. Please check telegraf.log at {1}"
                            .format(max_restart_retries, log_dir))
                else:
                    telegraf_restart_retries = 0
                # 5. Check if ME is running, if not, then restart
                if enable_metrics_ext:
                    if not me_handler.is_running(is_lad=True):
                        if me_restart_retries < max_restart_retries:
                            me_restart_retries += 1
                            hutil.log(
                                "MetricsExtension binary process is not running. Restarting MetricsExtension now. Retry count - {0}"
                                .format(me_restart_retries))
                            me_out, me_msg = me_handler.stop_metrics_service(
                                is_lad=True)
                            if me_out:
                                hutil.log(me_msg)
                            else:
                                hutil.error(me_msg)
                            start_metrics_out, log_messages = me_handler.start_metrics(
                                is_lad=True)
                            if start_metrics_out:
                                hutil.log(
                                    "Successfully started metrics-extension.")
                            else:
                                hutil.error(log_messages)
                        else:
                            hutil.error(
                                "MetricsExtension binary process is not running. Failed to restart after {0} retries. Please check /var/log/syslog for ME logs"
                                .format(max_restart_retries))
                    else:
                        me_restart_retries = 0
                    # 6. Regenerate the MSI auth token required for ME if it is nearing expiration
                    # Generate/regenerate MSI Token required by ME
                    global me_msi_token_expiry_epoch
                    generate_token = False
                    me_token_path = g_ext_dir + "/config/metrics_configs/AuthToken-MSI.json"

                    if me_msi_token_expiry_epoch is None or me_msi_token_expiry_epoch == "":
                        if os.path.isfile(me_token_path):
                            with open(me_token_path, "r") as f:
                                authtoken_content = json.loads(f.read())
                                if authtoken_content and "expires_on" in authtoken_content:
                                    me_msi_token_expiry_epoch = authtoken_content[
                                        "expires_on"]
                                else:
                                    generate_token = True
                        else:
                            generate_token = True

                    if me_msi_token_expiry_epoch:
                        currentTime = datetime.datetime.now()
                        token_expiry_time = datetime.datetime.fromtimestamp(
                            float(me_msi_token_expiry_epoch))
                        if token_expiry_time - currentTime < datetime.timedelta(
                                minutes=30):
                            # The MSI Token will expire within 30 minutes. We need to refresh the token
                            generate_token = True

                    if generate_token:
                        generate_token = False
                        msi_token_generated, me_msi_token_expiry_epoch, log_messages = me_handler.generate_MSI_token(
                        )
                        if msi_token_generated:
                            hutil.log(
                                "Successfully refreshed metrics-extension MSI Auth token."
                            )
                        else:
                            hutil.error(log_messages)

            # Out of the inner while loop: mdsd terminated.
            if mdsd_stdout_stream:
                mdsd_stdout_stream.close()
                mdsd_stdout_stream = None

            # Check if this is NOT a quick crash -- we consider a crash quick
            # if it's within 30 minutes from the start time. If it's not quick,
            # we just continue by restarting mdsd.
            mdsd_up_time = datetime.datetime.now() - last_mdsd_start_time
            if mdsd_up_time > datetime.timedelta(minutes=30):
                mdsd_terminated_msg = "MDSD terminated after " + str(mdsd_up_time) + ". "\
                                      + tail(mdsd_stdout_redirect_path) + tail(err_file_path)
                hutil.log(mdsd_terminated_msg)
                num_quick_consecutive_crashes = 0
                continue

            # It's a quick crash. Log error and add an extension event.
            num_quick_consecutive_crashes += 1

            mdsd_crash_msg = "MDSD crash(uptime=" + str(
                mdsd_up_time) + "):" + tail(mdsd_stdout_redirect_path) + tail(
                    err_file_path)
            hutil.error("MDSD crashed:" + mdsd_crash_msg)

        # mdsd all 3 allowed quick/consecutive crashes exhausted
        hutil.do_status_report(waagent_ext_event_type, "error", '1',
                               "mdsd stopped: " + mdsd_crash_msg)
        # Need to tear down omsagent setup for LAD before returning/exiting if it was set up earlier
        oms.tear_down_omsagent_for_lad(RunGetOutput, False)
        try:
            waagent.AddExtensionEvent(name=hutil.get_name(),
                                      op=waagent_ext_event_type,
                                      isSuccess=False,
                                      version=hutil.get_extension_version(),
                                      message=mdsd_crash_msg)
        except Exception:
            pass

    except Exception as e:
        if mdsd_stdout_stream:
            hutil.error("Error :" + tail(mdsd_stdout_redirect_path))
        errmsg = "Failed to launch mdsd with error: {0}, traceback: {1}".format(
            e, traceback.format_exc())
        hutil.error(errmsg)
        hutil.do_status_report(waagent_ext_event_type, 'error', '1', errmsg)
        waagent.AddExtensionEvent(name=hutil.get_name(),
                                  op=waagent_ext_event_type,
                                  isSuccess=False,
                                  version=hutil.get_extension_version(),
                                  message=errmsg)
    finally:
        if mdsd_stdout_stream:
            mdsd_stdout_stream.close()
Exemple #4
0
def main(command):
    init_globals()

    global g_ext_op_type
    global me_msi_token_expiry_epoch

    g_ext_op_type = get_extension_operation_type(command)
    waagent_ext_event_type = wala_event_type_for_telemetry(g_ext_op_type)

    if not check_for_supported_waagent_and_distro_version():
        return

    try:
        hutil.log("Dispatching command:" + command)

        if g_ext_op_type is waagent.WALAEventOperation.Disable:
            if g_dist_config.use_systemd():
                RunGetOutput(
                    'systemctl stop mdsd-lde && systemctl disable mdsd-lde')
            else:
                stop_mdsd()
            oms.tear_down_omsagent_for_lad(RunGetOutput, False)

            #Stop the telegraf and ME services
            tel_out, tel_msg = telhandler.stop_telegraf_service(is_lad=True)
            if tel_out:
                hutil.log(tel_msg)
            else:
                hutil.error(tel_msg)

            me_out, me_msg = me_handler.stop_metrics_service(is_lad=True)
            if me_out:
                hutil.log(me_msg)
            else:
                hutil.error(me_msg)

            hutil.do_status_report(g_ext_op_type, "success", '0',
                                   "Disable succeeded")

        elif g_ext_op_type is waagent.WALAEventOperation.Uninstall:
            if g_dist_config.use_systemd():
                RunGetOutput(
                    'systemctl stop mdsd-lde && systemctl disable mdsd-lde ' +
                    '&& rm /lib/systemd/system/mdsd-lde.service')
            else:
                stop_mdsd()
            # Must remove lad-mdsd package first because of the dependencies
            cmd_exit_code, cmd_output = g_dist_config.remove_lad_mdsd()
            if cmd_exit_code != 0:
                hutil.error(
                    'lad-mdsd remove failed. Still proceeding to uninstall. '
                    'Exit code={0}, Output={1}'.format(cmd_exit_code,
                                                       cmd_output))
            oms.tear_down_omsagent_for_lad(RunGetOutput, True)

            #Stop the telegraf and ME services
            tel_out, tel_msg = telhandler.stop_telegraf_service(is_lad=True)
            if tel_out:
                hutil.log(tel_msg)
            else:
                hutil.error(tel_msg)

            me_out, me_msg = me_handler.stop_metrics_service(is_lad=True)
            if me_out:
                hutil.log(me_msg)
            else:
                hutil.error(me_msg)

            #Delete the telegraf and ME services
            tel_rm_out, tel_rm_msg = telhandler.remove_telegraf_service()
            if tel_rm_out:
                hutil.log(tel_rm_msg)
            else:
                hutil.error(tel_rm_msg)

            me_rm_out, me_rm_msg = me_handler.remove_metrics_service(
                is_lad=True)
            if me_rm_out:
                hutil.log(me_rm_msg)
            else:
                hutil.error(me_rm_msg)

            hutil.do_status_report(g_ext_op_type, "success", '0',
                                   "Uninstall succeeded")

        elif g_ext_op_type is waagent.WALAEventOperation.Install:
            # Install dependencies (omsagent, which includes omi, scx).
            configurator = create_core_components_configs()
            dependencies_err, dependencies_msg = setup_dependencies_and_mdsd(
                configurator)
            if dependencies_err != 0:
                g_lad_log_helper.report_mdsd_dependency_setup_failure(
                    waagent_ext_event_type, dependencies_msg)
                hutil.do_status_report(g_ext_op_type, "error", '-1',
                                       "Install failed")
                return

            #Start the Telegraf and ME services on Enable after installation is complete
            start_telegraf_out, log_messages = telhandler.start_telegraf(
                is_lad=True)
            if start_telegraf_out:
                hutil.log("Successfully started metrics-sourcer.")
            else:
                hutil.error(log_messages)

            if enable_metrics_ext:
                # Generate/regenerate MSI Token required by ME
                msi_token_generated, me_msi_token_expiry_epoch, log_messages = me_handler.generate_MSI_token(
                )
                if msi_token_generated:
                    hutil.log(
                        "Successfully generated metrics-extension MSI Auth token."
                    )
                else:
                    hutil.error(log_messages)

                start_metrics_out, log_messages = me_handler.start_metrics(
                    is_lad=True)
                if start_metrics_out:
                    hutil.log("Successfully started metrics-extension.")
                else:
                    hutil.error(log_messages)

            if g_dist_config.use_systemd():
                install_lad_as_systemd_service()
            hutil.do_status_report(g_ext_op_type, "success", '0',
                                   "Install succeeded")

        elif g_ext_op_type is waagent.WALAEventOperation.Enable:
            if hutil.is_current_config_seq_greater_inused():
                configurator = create_core_components_configs()
                dependencies_err, dependencies_msg = setup_dependencies_and_mdsd(
                    configurator)
                if dependencies_err != 0:
                    g_lad_log_helper.report_mdsd_dependency_setup_failure(
                        waagent_ext_event_type, dependencies_msg)
                    hutil.do_status_report(g_ext_op_type, "error", '-1',
                                           "Enabled failed")
                    return

                #Start the Telegraf and ME services on Enable after installation is complete
                start_telegraf_out, log_messages = telhandler.start_telegraf(
                    is_lad=True)
                if start_telegraf_out:
                    hutil.log("Successfully started metrics-sourcer.")
                else:
                    hutil.error(log_messages)

                if enable_metrics_ext:
                    # Generate/regenerate MSI Token required by ME
                    generate_token = False
                    me_token_path = g_ext_dir + "/metrics_configs/AuthToken-MSI.json"

                    if me_msi_token_expiry_epoch is None or me_msi_token_expiry_epoch == "":
                        if os.path.isfile(me_token_path):
                            with open(me_token_path, "r") as f:
                                authtoken_content = f.read()
                                if authtoken_content and "expires_on" in authtoken_content:
                                    me_msi_token_expiry_epoch = authtoken_content[
                                        "expires_on"]
                                else:
                                    generate_token = True
                        else:
                            generate_token = True

                    if me_msi_token_expiry_epoch:
                        currentTime = datetime.datetime.now()
                        token_expiry_time = datetime.datetime.fromtimestamp(
                            me_msi_token_expiry_epoch)
                        if token_expiry_time - currentTime < datetime.timedelta(
                                minutes=30):
                            # The MSI Token will expire within 30 minutes. We need to refresh the token
                            generate_token = True

                    if generate_token:
                        generate_token = False
                        msi_token_generated, me_msi_token_expiry_epoch, log_messages = me_handler.generate_MSI_token(
                        )
                        if msi_token_generated:
                            hutil.log(
                                "Successfully refreshed metrics-extension MSI Auth token."
                            )
                        else:
                            hutil.error(log_messages)

                    start_metrics_out, log_messages = me_handler.start_metrics(
                        is_lad=True)
                    if start_metrics_out:
                        hutil.log("Successfully started metrics-extension.")
                    else:
                        hutil.error(log_messages)

            if g_dist_config.use_systemd():
                install_lad_as_systemd_service()
                RunGetOutput('systemctl enable mdsd-lde')
                mdsd_lde_active = RunGetOutput(
                    'systemctl status mdsd-lde')[0] is 0
                if not mdsd_lde_active or hutil.is_current_config_seq_greater_inused(
                ):
                    RunGetOutput('systemctl restart mdsd-lde')
            else:
                # if daemon process not runs
                lad_pids = get_lad_pids()
                hutil.log("get pids:" + str(lad_pids))
                if len(lad_pids
                       ) != 2 or hutil.is_current_config_seq_greater_inused():
                    stop_mdsd()
                    start_daemon()
            hutil.set_inused_config_seq(hutil.get_seq_no())
            hutil.do_status_report(
                g_ext_op_type, "success", '0',
                "Enable succeeded, extension daemon started")
            # If the -daemon detects a problem, e.g. bad configuration, it will overwrite this status with a more
            # informative one. If it succeeds, all is well.

        elif g_ext_op_type is "Daemon":
            configurator = create_core_components_configs()
            if configurator:
                start_mdsd(configurator)

        elif g_ext_op_type is waagent.WALAEventOperation.Update:
            hutil.do_status_report(g_ext_op_type, "success", '0',
                                   "Update succeeded")

    except Exception as e:
        hutil.error(
            "Failed to perform extension operation {0} with error:{1}, {2}".
            format(g_ext_op_type, e, traceback.format_exc()))
        hutil.do_status_report(
            g_ext_op_type, 'error', '0',
            'Extension operation {0} failed:{1}'.format(g_ext_op_type, e))