def runTest(self):
        white = "MAP17186.raw"
        sample = "MAP17269.raw"

        # Libisis values to check against
        tiny = 1e-10
        huge = 1e10

        v_out_lo = 0.01
        v_out_hi = 100.0

        vv_lo = 0.1
        vv_hi = 2.0
        vv_sig = 0.0

        sv_sig = 3.3
        sv_hi = 1.5
        sv_lo = 0.0
        s_zero = True

        reducer = reduction.setup_reducer("MAPS")
        # parameters which explicitly affect diagnostics
        #
        reducer.prop_man.wb_integr_range = [20, 300]
        reducer.prop_man.bkgd_range = [12000, 18000]
        diag_mask = reducer.diagnose(
            white,
            sample,
            tiny=tiny,
            huge=huge,
            van_out_lo=v_out_lo,
            van_out_hi=v_out_hi,
            van_lo=vv_lo,
            van_hi=vv_hi,
            van_sig=vv_sig,
            samp_lo=sv_lo,
            samp_hi=sv_hi,
            samp_sig=sv_sig,
            samp_zero=s_zero,
            hard_mask_file=None,
        )

        sample = reducer.get_run_descriptor(sample)
        sample_ws = sample.get_workspace()
        MaskDetectors(Workspace=sample_ws, MaskedWorkspace=diag_mask)

        # Save the masked spectra nmubers to a simple ASCII file for comparison
        self.saved_diag_file = os.path.join(config["defaultsave.directory"], "CurrentDirectInelasticDiag.txt")
        handle = file(self.saved_diag_file, "w")
        for index in range(sample_ws.getNumberHistograms()):
            if sample_ws.getDetector(index).isMasked():
                spec_no = sample_ws.getSpectrum(index).getSpectrumNo()
                handle.write(str(spec_no) + "\n")
        handle.close
Esempio n. 2
0
    def runTest(self):
        white = 'MAP17186.raw'
        sample = 'MAP17269.raw'

        # Libisis values to check against
        tiny = 1e-10
        huge = 1e10

        v_out_lo = 0.01
        v_out_hi = 100.

        vv_lo = 0.1
        vv_hi = 2.0
        vv_sig = 0.0

        sv_sig = 3.3
        sv_hi = 1.5
        sv_lo = 0.0
        s_zero = True

        reducer = reduction.setup_reducer('MAPS')
        # parameters which explicitly affect diagnostics
        #
        reducer.prop_man.wb_integr_range = [20, 300]
        reducer.prop_man.bkgd_range = [12000, 18000]
        diag_mask = reducer.diagnose(white,
                                     sample,
                                     tiny=tiny,
                                     huge=huge,
                                     van_out_lo=v_out_lo,
                                     van_out_hi=v_out_hi,
                                     van_lo=vv_lo,
                                     van_hi=vv_hi,
                                     van_sig=vv_sig,
                                     samp_lo=sv_lo,
                                     samp_hi=sv_hi,
                                     samp_sig=sv_sig,
                                     samp_zero=s_zero,
                                     hard_mask_file=None)

        sample = reducer.get_run_descriptor(sample)
        sample_ws = sample.get_workspace()
        ms.MaskDetectors(Workspace=sample_ws, MaskedWorkspace=diag_mask)

        # Save the masked spectra nmubers to a simple ASCII file for comparison
        self.saved_diag_file = os.path.join(ms.config['defaultsave.directory'],
                                            'CurrentDirectInelasticDiag.txt')
        with open(self.saved_diag_file, 'w') as handle:
            spectrumInfo = sample_ws.spectrumInfo()
            for index in range(sample_ws.getNumberHistograms()):
                if spectrumInfo.isMasked(index):
                    spec_no = sample_ws.getSpectrum(index).getSpectrumNo()
                    handle.write(str(spec_no) + '\n')
Esempio n. 3
0
def setup(instname=None,reload=False):
    """
    setup('mar')
    setup instrument reduction parameters from instname_parameter.xml file

    if the instrument has already been defined, does nothing unless
    reload = True is specified
    """

    global Reducer
    if instname is None :
        instname = config['default.instrument']

    if not (Reducer is None or Reducer.prop_man is None):
        old_name=Reducer.prop_man.instr_name
        if  old_name.upper()[0:3] == instname.upper()[0:3] :
            if not reload :
                return  # has been already defined

    Reducer = DRC.setup_reducer(instname,reload)
Esempio n. 4
0
def setup(instname=None,reload=False):
    """
    setup('mar')
    setup instrument reduction parameters from instname_parameter.xml file

    if the instrument has already been defined, does nothing unless
    reload = True is specified
    """

    global Reducer
    if instname is None :
        instname = config['default.instrument']

    if not (Reducer is None or Reducer.prop_man is None):
        old_name=Reducer.prop_man.instr_name
        if  old_name.upper()[0:3] == instname.upper()[0:3] :
            if not reload :
                return  # has been already defined

    Reducer = DRC.setup_reducer(instname,reload)