else: import ConfigParser # Import configuration parser class. from logger import Logger # Import logger class. from biochem import Biochem # Import biochecmistry class. #--------------------- G.007 fluidics sub-system initialization ------------------------ config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() # get current time logger = Logger(config) # initialize logger object biochem = Biochem( 'WL1', int(sys.argv[1]), logger ) # Initialize biochemistry object - cycle-name and flowcell-number need to be passed. #--------------------------------------------------------------------------------------- # FLUIDICS SUB-SYSTEM FUNCTIONS #--------------------------------------------------------------------------------------- logger.info('***\t*\t--> Started %s method execution - fluidics_utils.py' % sys.arg[2]) if method is 'clean_V1_to_syringe': biochem.clean_V1_to_syringe() elif method is 'clean_V2_to_syringe': biochem.clean_V2_to_syringe()
import ConfigParser # Import configuration parser class. from logger import Logger # Import logger class. from biochem import Biochem # Import biochecmistry class. #--------------------- G.007 fluidics sub-system initialization ------------------------ config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() # get current time logger = Logger(config) # initialize logger object print '\n' biochem = Biochem( 'WL1', 0, logger ) # Initialize biochemistry object - cycle-name and flowcell-number need to be passed. logger.info('---\t-\t--> Started %s method execution - device_utils.py' % sys.argv[1]) method = sys.argv[1] # set method to second argument #--------------------------------------------------------------------------------------- # TEMPERATURE CONTROL #--------------------------------------------------------------------------------------- if method == 'set_to_temperature_control1': biochem.mux.set_to_temperature_control1() elif method == 'set_to_temperature_control2': biochem.mux.set_to_temperature_control2()
if len(sys.argv) < 3: print '\n--> Error: not correct input!\n--> Usage: python ' + \ 'biochem_utils.py flowcell-number method\n' sys.exit() else: import ConfigParser from biochem import Biochem config = ConfigParser.ConfigParser() config.readfp(open(os.environ['POLONATOR_PATH'] + '/config_files/sequencing.cfg')) home_dir = os.environ['HOME'] + config.get("communication","home_dir") # Initialize biochemistry object - cycle-name and flowcell-number # need to be set later biochem = Biochem('WL1', int(sys.argv[1])) method = sys.argv[2] log.info("---\t-\t--> Started %s method execution - biochem_utils.py" % \ (method)) # usage: biochem_utils.py fcnum cycle_ligation cyclename # cyclename must be a valid cyclename that has a nonamer/hyb # valve/port mapping in sequencing.cfg # cyclename can be either 3 or 4 chars in length if method == 'cycle_ligation': biochem.flowcell = int(sys.argv[1]) biochem.cycle_name = sys.argv[3] biochem.cycle = biochem.cycle_name[0:3] biochem.cycle_ligation()
else: import ConfigParser # Import configuration parser class. from logger import Logger # Import logger class. from biochem import Biochem # Import biochecmistry class. #--------------------- Walkameter fluidics sub-system initialization ------------------- config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() # get current time print '\n' logger = Logger(config) # initialize logger object biochem = Biochem(logger) # Initialize biochemistry object: cycle-number need to be passed. #--------------------------------------------------------------------------------------- # FLUIDICS SUB-SYSTEM FUNCTIONS #--------------------------------------------------------------------------------------- logger.info('*\t--> Started %s method execution - biochem_utils.py' % sys.argv[1]) method = (sys.argv[1]) # assign name of requested method if method == 'capping_1': biochem.capping_1() elif method == 'capping_2': biochem.capping_2()
else: import ConfigParser # Import configuration parser class. from logger import Logger # Import logger class. from biochem import Biochem # Import biochecmistry class. #--------------------- G.007 fluidics sub-system initialization ------------------------ config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() # get current time logger = Logger(config) # initialize logger object biochem = Biochem('WL1', int(sys.argv[1]), logger) # Initialize biochemistry object - cycle-name and flowcell-number need to be passed. #--------------------------------------------------------------------------------------- # FLUIDICS SUB-SYSTEM FUNCTIONS #--------------------------------------------------------------------------------------- logger.info('***\t*\t--> Started %s method execution - fluidics_utils.py' % sys.arg[2]) if method is 'clean_V1_to_syringe': biochem.clean_V1_to_syringe() elif method is 'clean_V2_to_syringe': biochem.clean_V2_to_syringe() elif method is 'clean_flowcell_and_syringe': biochem.clean_flowcell_and_syringe()
For: G.007 polony sequencer design [fluidics software] at the Church Lab - Genetics Department, Harvard Medical School. Purpose: polony_sequencing.py performs a polony sequencing biochemistry consisting of given number of cycles of iteration (26) This software may be used, modified, and distributed freely, but this header may not be modified and must appear at the top of this file. ------------------------------------------------------------------------------- """ import sys from biochem import Biochem # Import biochecmistry class. #--------------------------- Configuration input handling ------------------------------ if len(sys.argv) < 3: print '\n--> Error: not correct input!\n--> Usage: python polony_sequencing.py cycle-name flowcell-number\n' sys.exit() #--------------------- G.007 fluidics sub-system initialization ------------------------ t0 = time.time() # Get current time. biochem = Biochem( sys.argv[1], int(sys.argv[2]) ) # Initialize biochemistry object - cycle-name and flowcell-number need to be passed. #-------------------------- Alternating cycle iterations ------------------------------- biochem.run() # Run polony sequencing cycle(s).
if (installed_flowcells == 1): for cycle_number in range(0, cycle_list_length): cycle_list[cycle_number] = cycle_list[cycle_number].strip() logger.info("---\t-\t--> Cycle_list key: %s" % \ cycle_list[cycle_number]) logger.info("---\t-\t--> Cycle number: %i" % cycle_number) cycle_list2 = cycle_list # if(cycle_list[cycle_number] == 'abc'): if(1): time.sleep(0.1) else: # print cycle_list[cycle_number] biochem = Biochem(cycle_list[cycle_number], flowcell, logger) biochem.start() while(biochem.isAlive()): session.parse_read_string('y.ob[2]=1', '>') session.parse_read_string('y.ob[2]=0', '>') time.sleep(1) if(cycle_list[cycle_number] == 'abc'): time.sleep(0.1) else: # print cycle_list[cycle_number] imager = PolonatorImager.Imager(cycle_list[cycle_number], \ flowcell) imager.start()
import commands import ConfigParser from logger import Logger from biochem import Biochem print '\nINFO\t *\t--> START PRIMER WALKING MAIN - walking_main.py\n' t0 = time.time() # get current time config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) cycle_iter = eval(config.get("cycle_constants", "cycle_iter")) logger = Logger(config) # initialize logger object biochem = Biochem(logger) # initialize biochemistry object if biochem.speech_option == 1: commands.getstatusoutput('mplayer -ao pulse ../../../speech/welcome.wav') commands.getstatusoutput('mplayer -ao pulse ../../../speech/start.wav') logger.info("*\t--> Started primer walking") while (biochem.cycle < cycle_iter): biochem.cycle += 1 if biochem.speech_option == 1: commands.getstatusoutput('mplayer -ao pulse ../../../speech/cycle_' + str(biochem.cycle) + '.wav') biochem.run()
#!/usr/local/bin/python import sys import time import ConfigParser from logger import Logger from biochem import Biochem config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() logger = Logger(config) b = Biochem('WL1', 0, logger) #b.mux.discrete_valve4_open() b.mux.discrete_valve4_close()
Genetics Department, Harvard Medical School. Purpose: polony_sequencing.py performs a polony sequencing biochemistry consisting of given number of cycles of iteration (26) This software may be used, modified, and distributed freely, but this header may not be modified and must appear at the top of this file. ------------------------------------------------------------------------------- """ import sys from biochem import Biochem # Import biochecmistry class. #--------------------------- Configuration input handling ---------------------- if len(sys.argv) < 3: print '\n--> Error: not correct input!\n--> Usage: python ' + \ 'polony_sequencing.py cycle-name flowcell-number\n' sys.exit() #--------------------- G.007 fluidics sub-system initialization ---------------- t0 = time.time() # Get current time. # Initialize biochemistry object - cycle-name and flowcell-number need to # be passed. biochem = Biochem(sys.argv[1], int(sys.argv[2])) #-------------------------- Alternating cycle iterations ----------------------- biochem.run() # Run polony sequencing cycle(s).
#--------------------------- Configuration input handling ------------------------------ if len(sys.argv) < 3: print '\n--> Error: not correct input!\n--> Usage: python biochem_test.py cycle-name flowcell-number\n' sys.exit() #--------------------- G.007 fluidics sub-system initialization ------------------------ config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() # get current time logger = Logger(config) # initialize logger object print '\n' biochem = Biochem(sys.argv[1], int(sys.argv[2]), logger) # Initialize biochemistry object - cycle-name and flowcell-number need to be passed. #--------------------------------------------------------------------------------------- # BIOCHEMISTRY CONTROL #--------------------------------------------------------------------------------------- logger.info('***\t*\t--> Started biochemistry object testing - biochem_test.py') #--------------------------------- Initialization -------------------------------------- #biochem.syringe_pump_init() #biochem.reagent_block_init() # Set reagent block cooler to constant temperature, 4 Celsius degrees. #biochem.rotary_valve1_init() # Initialize reagent start points in ten port rotary valve V1. #biochem.rotary_valve2_init() # Initialize reagent start points in ten port rotary valve V2. #biochem.rotary_valve3_init() # Initialize reagent start points in ten port rotary valve V3.
cycle_number_bio = 0 flowcell = 0 cycle_number_im = 0 if (installed_flowcells == 1): for cycle_number in range(0, cycle_list_length): cycle_list[cycle_number] = cycle_list[cycle_number].strip() logger.info("---\t-\t--> Cycle_list key: %s" % cycle_list[cycle_number]) logger.info("---\t-\t--> Cycle number: %i" % cycle_number) cycle_list2 = cycle_list if (cycle_list[cycle_number] == 'AM1g'): time.sleep(0.1) else: biochem = Biochem(cycle_list[cycle_number], flowcell, logger) biochem.start() while (biochem.isAlive()): session.parse_read_string('y.ob[2]=1', '>') session.parse_read_string('y.ob[2]=0', '>') time.sleep(0.1) # if(cycle_list[cycle_number] == 'WL1'): # time.sleep(0.1) # else: # imager = PolonatorImager.Imager(cycle_list[cycle_number], flowcell) # imager.start() # # while(imager.isAlive()): # session.parse_read_string('y.ob[1]=1', '>')
else: import ConfigParser # Import configuration parser class. from logger import Logger # Import logger class. from biochem import Biochem # Import biochecmistry class. #--------------------- G.007 fluidics sub-system initialization ------------------------ config = ConfigParser.ConfigParser() config.readfp(open('config.txt')) t0 = time.time() # get current time logger = Logger(config) # initialize logger object print '\n' biochem = Biochem('WL1', int(sys.argv[1]), logger) # Initialize biochemistry object - cycle-name and flowcell-number need to be passed. #--------------------------------------------------------------------------------------- # FLUIDICS SUB-SYSTEM FUNCTIONS #--------------------------------------------------------------------------------------- logger.info('---\t-\t--> Started %s method execution - biochem_utils.py' % sys.argv[2]) method = sys.argv[2] # set method to second argument if method == 'clean_V1_to_syringe': biochem.clean_V1_to_syringe() elif method == 'clean_V2_to_syringe': biochem.clean_V2_to_syringe() elif method == 'clean_flowcell_and_syringe':