Esempio n. 1
0
    l = LED()  # 实例化led对象
    l.t = 1.5  # 闪灯间隔为1.5s
    t = threading.Thread(target=configure)
    t.start()  # 开启启动flask的web服务器的线程,不然主函数无法向下运行
    if os.path.isfile('settings.txt'):  # 有配置文件则读取配置文件
        with open('settings.txt', 'r') as f:
            settings = eval(f.read())
       
        while True:  # 连接wifi并自动重连
            ret = wifi_connect(settings['ssid'], settings['psw'])
            if ret:
                os.system('sh ./route.sh')  # 网络配置脚本
                break
        l.t = 0.8  # 闪灯变快以示完成
        while True:  # 连接打印机并自动重连,同时自动判定波特率
            ret = p.connect(115200)
            if ret:
                break
            ret = p.connect(250000)
            if ret:
                break
            time.sleep(5)
        l.t = 0.1  # 闪灯变快以示完成
        while True:  # 连接服务器并自动重连
            ret = u.connect(settings['ip'], settings['eid'], settings['pw'])
            if ret:
                break
            time.sleep(5)
        l.stop()  # 灯常亮以示全部完成

Esempio n. 2
0
def main(radius, com_port, hot_cal):

    # Check for existing options
    try:
        opts = load_opts()
    except Exception:
        opts = {}

    radius = opts['radius'] = radius or opts.get('radius')
    com_port = opts['com_port'] = com_port or opts.get('com_port')
    hot_cal = opts['hot_cal'] = hot_cal or opts.get('hot_cal')
    cal_report = opts.setdefault('cal_report', [])

    if radius is None:
        radius = opts['radius'] = click.prompt(
            "Enter the radius of the probe points:", type=float)
    if com_port is None:
        com_port = opts['com_port'] = click.prompt(
            "Enter the COM port to connect to the printer")

    # Save options for future calls
    save_opts(opts)

    # Start calibration process
    choice = click.confirm(
        "Do you want to start the calibration process with a radius of {}mm?".
        format(radius))
    if not choice:
        return

    printer = Printer(com_port)
    printer.connect()
    printer.send_command(b"M80")  # Power supply on
    printer.send_command(b"G28")  # home
    if hot_cal is not None:
        hclim = [30, 100]
        if not isinstance(
                hot_cal,
            (int, float)) or hot_cal < hclim[0] or hot_cal > hclim[1]:
            click.echo(
                "hot_cal should be a number between {} and {}".format(*hclim))
            return
        click.echo("Warming up to {}C".format(hot_cal))
        printer.send_command("M190 S{}".format(hot_cal).encode())

    while True:
        printer.update_printer_geometry()
        tuner = Tuner(*printer.for_tuner(radius))

        probe_pts = tuner.get_probe_points()

        # Obtain Z height errors
        for i, point in enumerate(probe_pts):
            probe_num = 0

            z_err = 0

            last_z_err = 0
            last_operation = "start"

            initial_z = 1

            click.echo("\n2 to lower, 5 to finish, 8 to erase previous")

            while probe_num < num_probes:
                if last_operation in ["start", "set_z_err"]:
                    # Go to the probe point
                    if last_operation == "start":
                        z = initial_z
                    else:
                        z = -last_z_err * num_probes + feeler_gage_thickness + 0.2
                    printer.probe_point(point[0], point[1], z=z)
                    last_operation = "go to probe"

                pch = ""
                while pch not in probe_choices:
                    pch = msvcrt.getch()
                if pch == b"2":
                    printer.send_command(b"G91")  # Set relative mode
                    printer.send_command(b"G1 Z-0.05")
                    printer.send_command(b"G90")  # set absolute mode
                elif pch == b"5":
                    last_operation = "set_z_err"
                    printer.get_current_position()

                    click.echo("z_err: {:.2f}".format(printer.z -
                                                      feeler_gage_thickness))
                    last_z_err = -(printer.z -
                                   feeler_gage_thickness) / num_probes
                    z_err += last_z_err
                    probe_num += 1
                elif pch == b"8":
                    if last_operation != "undo":
                        z_err -= last_z_err
                        last_z_err = 0
                        probe_num -= 1
                    last_operation = "undo"

            click.echo("Average z_err for point: {:.3f}".format(z_err))

            probe_pts[i][2] = z_err

        printer.home()
        click.echo("\nZ errors:")
        pp = pprint.PrettyPrinter(indent=4)
        pp.pprint(probe_pts)

        tuner.set_probe_errors(probe_pts)

        cmd, dev_before, dev_after = tuner.calc()

        cal_report.append({
            'datetime':
            datetime.datetime.now().replace(microsecond=0).isoformat(),
            'dev_before':
            dev_before,
            'dev_after':
            dev_after,
            'cmds':
            cmd,
            'saved':
            False
        })
        save_opts(opts)

        click.echo("Commands to run for correction:\n{}\n{}".format(*cmd))

        choice = click.confirm("Deviation: {} (before: {}), do you want "
                               "to run another calibration round?".format(
                                   dev_after, dev_before))
        if not choice:
            save_choice = click.confirm(
                "Do you want to save the result of this calibration to Flash?")
            if save_choice:
                click.echo("Saving to Flash with M500 command")
                cal_report[-1]['saved'] = True
                save_opts(opts)
                printer.send_command(b"M500")

            click.echo("Exiting")
            printer.send_command("G28")
            printer.send_command("M81")  # Turn printer off
            return

        # Apply configuration
        printer.send_command(cmd[0].encode())
        printer.send_command(cmd[1].encode())