def gate_scan_with_c_optimize():
    if repeated_red_scans(gate_scan=True, gate_range=(0,1200),pts=19):
        qt.get_setup_instrument('GreenAOM').set_power(20e-6)
        qt.get_setup_instrument('c_optimiz0r').optimize(xyz_range=[.2,.2,.5], cnt=1, int_time=50, max_cycles=20)
        qt.get_setup_instrument('c_optimiz0r').optimize(xyz_range=[.05,.1,.2], cnt=1, int_time=50, max_cycles=20)
        qt.get_setup_instrument('optimiz0r').optimize(cnt=1, dims=['x','y'], cycles=3, int_time=50)
        qt.get_setup_instrument('GreenAOM').set_power(0e-6)
        repeated_red_scans(gate_scan=True, gate_range=(0,-1200),pts=19)
    def __init__(self, name='LT1', red_labjack_dac_nr=6, yellow_labjack_dac_nr = 0, red_wm_channel = 6, yellow_wm_channel = 2):
        LaserFrequencyScan.__init__(self, name)
        
        self.adwin = qt.get_setup_instrument('adwin')
        self.physical_adwin=qt.get_setup_instrument('physical_adwin_lt2')
        self.mw = qt.get_setup_instrument('SMB100')
        self.labjack= qt.get_setup_instrument('labjack')

        self.set_red_laser_voltage = lambda x: self.labjack.__dict__['set_bipolar_dac'+str(red_labjack_dac_nr)](x)
        self.get_red_laser_voltage = lambda : self.labjack.__dict__['get_bipolar_dac'+str(red_labjack_dac_nr)]()
        self.set_red_power = qt.get_setup_instrument('NewfocusAOM').set_power


        self.set_yellow_laser_voltage = lambda x: self.labjack.__dict__['set_bipolar_dac'+str(yellow_labjack_dac_nr)](x)
        self.get_yellow_laser_voltage = lambda : self.labjack.__dict__['get_bipolar_dac'+str(yellow_labjack_dac_nr)]()
        self.set_yellow_power = qt.get_setup_instrument('YellowAOM').set_power

        self.set_repump_power = qt.get_setup_instrument('GreenAOM').set_power

        self.get_frequency = lambda x : self.physical_adwin.Get_FPar(x+40)
        self.get_counts = self.adwin.measure_counts
        self.counter_channel = 0
        self.red_wm_channel = red_wm_channel
        self.red_voltage_frequency_relation_sign = -1


        self.yellow_voltage_frequency_relation_sign = 1
        self.yellow_wm_channel = yellow_wm_channel

        self.max_v = 9.
        self.min_v = -9.

        self.set_gate_voltage = lambda x: qt.get_setup_instrument('ivvi').set_dac2(x)
def gate_scan_with_c_optimize():
    if repeated_red_scans(gate_scan=True, gate_range=(0, 1200), pts=19):
        qt.get_setup_instrument('GreenAOM').set_power(20e-6)
        qt.get_setup_instrument('c_optimiz0r').optimize(xyz_range=[.2, .2, .5],
                                                        cnt=1,
                                                        int_time=50,
                                                        max_cycles=20)
        qt.get_setup_instrument('c_optimiz0r').optimize(
            xyz_range=[.05, .1, .2], cnt=1, int_time=50, max_cycles=20)
        qt.get_setup_instrument('optimiz0r').optimize(cnt=1,
                                                      dims=['x', 'y'],
                                                      cycles=3,
                                                      int_time=50)
        qt.get_setup_instrument('GreenAOM').set_power(0e-6)
        repeated_red_scans(gate_scan=True, gate_range=(0, -1200), pts=19)
    def __init__(self, name='LT4', red_labjack_dac_nr=4, yellow_labjack_dac_nr = 2, red_wm_channel = 8, yellow_wm_channel = 2):
        LaserFrequencyScan.__init__(self, name)
        
        self.adwin = qt.get_setup_instrument('adwin')
        self.physical_adwin=qt.get_setup_instrument('physical_adwin')
        self.mw = qt.get_setup_instrument('SMB100')
        self.labjack= qt.get_setup_instrument('labjack')
        self.wavemeter=qt.instruments['wavemeter']
        self.newfocus = qt.instruments['NewfocusAOM']
        self.set_red_laser_voltage = lambda x: self.labjack.__dict__['set_bipolar_dac'+str(red_labjack_dac_nr)](x)
        self.get_red_laser_voltage = lambda : self.labjack.__dict__['get_bipolar_dac'+str(red_labjack_dac_nr)]()
        self.set_red_power = qt.get_setup_instrument('MatisseAOM').set_power


        self.set_yellow_laser_voltage = lambda x: self.labjack.__dict__['set_bipolar_dac'+str(yellow_labjack_dac_nr)](x)
        self.get_yellow_laser_voltage = lambda : self.labjack.__dict__['get_bipolar_dac'+str(yellow_labjack_dac_nr)]()
        self.set_yellow_power = qt.get_setup_instrument('YellowAOM').set_power

        self.set_repump_power = qt.get_setup_instrument('GreenAOM').set_power

        self.get_frequency = lambda x : self.physical_adwin.Get_FPar(40+red_wm_channel) #(self.wavemeter.Get_Frequency(x)-470.4)*1000.
        self.get_counts = self.adwin.measure_counts
        self.counter_channel = 0
        self.red_wm_channel = red_wm_channel
        self.red_voltage_frequency_relation_sign = 1 #### 2014-08-14 for newfocus this is negative, DL maybe positive?


        self.yellow_voltage_frequency_relation_sign = 1
        self.yellow_wm_channel = yellow_wm_channel

        self.max_v = 9.
        self.min_v = -9.
    def __init__(self,
                 name='LT1',
                 red_labjack_dac_nr=6,
                 yellow_labjack_dac_nr=0,
                 red_wm_channel=6,
                 yellow_wm_channel=2):
        LaserFrequencyScan.__init__(self, name)

        self.adwin = qt.get_setup_instrument('adwin')
        self.physical_adwin = qt.get_setup_instrument('physical_adwin')
        self.mw = qt.get_setup_instrument('SMB100')
        self.labjack = qt.get_setup_instrument('labjack')

        self.set_red_laser_voltage = lambda x: self.labjack.__dict__[
            'set_bipolar_dac' + str(red_labjack_dac_nr)](x)
        self.get_red_laser_voltage = lambda: self.labjack.__dict__[
            'get_bipolar_dac' + str(red_labjack_dac_nr)]()
        self.set_red_power = qt.get_setup_instrument('NewfocusAOM').set_power

        self.set_yellow_laser_voltage = lambda x: self.labjack.__dict__[
            'set_bipolar_dac' + str(yellow_labjack_dac_nr)](x)
        self.get_yellow_laser_voltage = lambda: self.labjack.__dict__[
            'get_bipolar_dac' + str(yellow_labjack_dac_nr)]()
        self.set_yellow_power = qt.get_setup_instrument('YellowAOM').set_power

        self.set_repump_power = qt.get_setup_instrument('GreenAOM').set_power

        self.get_frequency = lambda x: self.physical_adwin.Get_FPar(x + 40)
        self.get_counts = lambda x: self.adwin.get_countrates(
        )  #self.adwin.measure_counts
        self.counter_channel = 0
        self.red_wm_channel = red_wm_channel
        self.red_voltage_frequency_relation_sign = -1

        self.yellow_voltage_frequency_relation_sign = 1
        self.yellow_wm_channel = yellow_wm_channel

        self.max_v = 9.5
        self.min_v = -9.5

        self.set_gate_voltage = lambda x: qt.get_setup_instrument('ivvi'
                                                                  ).set_dac3(x)
        qt.get_setup_instrument('c_optimiz0r').optimize(xyz_range=[.05,.1,.2], cnt=1, int_time=50, max_cycles=20)
        qt.get_setup_instrument('optimiz0r').optimize(cnt=1, dims=['x','y'], cycles=3, int_time=50)
        qt.get_setup_instrument('GreenAOM').set_power(0e-6)
        repeated_red_scans(gate_scan=True, gate_range=(0,-1200),pts=19)

def single_scan():
    m = Scan()

    m.mw.set_power(-7)
    m.mw.set_frequency(2.8265e9)
    m.mw.set_iq('off')
    m.mw.set_pulm('off')
    m.mw.set_status('on')
    #m.red_scan(74, 90, voltage_step=0.01, integration_time_ms=20, power = 3e-9)
    #m.yellow_red(62, 80, 0.02, 0.5e-9, 74, 92, 0.02, 20, 3e-9)
    m.yellow_scan(62, 77, power = 0.5e-9, voltage_step=0.02, voltage_step_scan=0.03)
    # m.oldschool_red_scan(55, 75, 0.01, 20, 0.5e-9)

    m.mw.set_status('off')

if __name__ == '__main__':
    qt.get_setup_instrument('GreenAOM').set_power(0.e-6)
    single_scan()
    #green_yellow_during_scan()
    #yellow_ionization_scan(13,20)
    # repeated_red_scans()
    # repeated_red_scans(spectral_diffusion=True)
    #repeated_red_scans(gate_scan=True, gate_range=(0,-1100),pts=12)
    #gate_scan_with_c_optimize()

Esempio n. 7
0
    #m.scan_to_frequency(65)
    # m.red_scan(60, 80, voltage_step=0.01, integration_time_ms=20, power = 3e-9)  #0.6e-9
    #m.yellow_red(0,30, 0.02, 0.3e-9, 65, 75, 0.02, 20, 0.5e-9)
    # m.yellow_scan(0, 30, power = 2e-9, voltage_step=0.02, voltage_step_scan=0.02)
    # m.oldschool_red_scan(55, 75, 0.01, 20, 0.5e-9)
    m.oldschool_red_scan(54, 56, 0.01, 20, 0.5e-9)

    if do_MW:
        m.mw.set_status('off')


def set_gate_voltage(v):
    if v > 2. or v < -2.:
        print 'Gate voltage too high:', v
        return False
    return qt.instruments['adwin'].set_dac_voltage(('gate', v))


if __name__ == '__main__':
    qt.get_setup_instrument('GreenAOM').set_power(0.000e-6)

    single_scan('Pippin_SIL3')
    #fast_gate_scan('Sam_SIL5_Green')
    #green_yellow_during_scan()
    #yellow_ionization_scan(13,20)
    # repeated_red_scans(pts =50)
    # repeated_red_scans(spectral_diffusion=True)
    #repeated_red_scans(gate_scan=True, gate_range=(0,-1100),pts=12)
    #gate_scan_with_c_optimize()