コード例 #1
0
    def set_up(self):
        """
        Initialize the test
        """

        LabHspaBase.set_up(self)

        if self._ftp_direction not in ["UL", "DL"]:
            self._error.Msg = "%s is not a known xfer direction" % self._ftp_direction
            raise AcsConfigException(AcsConfigException.INVALID_PARAMETER,
                                     self._error.Msg)

        if self._measurement_duration is None:
            raise AcsConfigException(AcsConfigException.INVALID_PARAMETER,
                                     "MEASUREMENT_DURATION should be int")

        if self._xfer_timeout is None:
            raise AcsConfigException(AcsConfigException.INVALID_PARAMETER,
                                     "XFER_TIMEOUT should be int")

        if self._call_duration is None:
            raise AcsConfigException(AcsConfigException.INVALID_PARAMETER,
                                     "CALL_DURATION should be int")

        if (self._measurement_duration +
                self._wait_time_before_measure) > self._call_duration:
            raise AcsConfigException(
                AcsConfigException.INVALID_PARAMETER,
                "call_duration should be always greater than"
                "MEASUREMENT_DURATION+%d (measurement start after %d seconds ftp starts)"
                % (self._wait_time_before_measure,
                   self._wait_time_before_measure))

        return Global.SUCCESS, self._error.Msg
コード例 #2
0
    def __init__(self, tc_name, global_config):
        LabHspaBase.__init__(self, tc_name, global_config)
        AnyUsbTether.__init__(self, tc_name, global_config)
        # if FTP transfer will be perform
        if self._perform_ftp:
            # Update the failure targets
            self._throughput_targets.set_failure_throughput_from_config(
                self._dut_config, self._failure_targets, self._kpi_test,
                tc_name._name)
            # Log Throughput targets for HSPA
            self._logger.info(
                throughput_targets_string(self._throughput_targets))

        self._ns_data = self._ns_data_3g
        self._ns_cell = self._ns_cell_3g
コード例 #3
0
    def __init__(self, tc_name, global_config):
        """
        Constructor
        """
        self._ftp_data_transfer_state_timeout = 10

        # Call LabMobilityBase Init function
        LabHspaBase.__init__(self, tc_name, global_config)

        # Set ps_data_ergch_information_state to OFF
        self._ps_data_ergch_information_state = "OFF"

        # Read agilent network from testcase xml Parameter
        self._rbt_channel_type = \
            self._tc_parameters.get_param_value("RBT_CHANNEL_TYPE")

        if self._cqi_scheme == "FIXED":
            self._cqi = int(self._tc_parameters.get_param_value("CQI"))

        # Read the DIRECTION value from UseCase xml Parameter
        self._ftp_direction = self._tc_parameters.get_param_value("DIRECTION")

        # Read the DL_FILE value from UseCase xml Parameter
        # ToCheck:Actually, this code works with Linux FTP server
        # But need to check if os.path.join work with a Windows FTp server
        # Maybe need a os.sep
        if self._ftp_direction == "DL":
            self._ftp_filename = os.path.join(
                self._ftp_path,
                self._tc_parameters.get_param_value("DL_FILENAME"))
        elif self._ftp_direction == "UL":
            # Read the UL_FILE value from UseCase xml Parameter
            self._ftp_filename = os.path.join(
                self._ftp_path,
                self._tc_parameters.get_param_value("UL_FILENAME"))

        # Read the MEASUREMENT_DURATION from UseCase xml Parameter
        self._measurement_duration = self._tc_parameters.\
            get_param_value("MEASUREMENT_DURATION")
        if isinstance(self._measurement_duration, str) and \
                self._measurement_duration.isdigit():
            self._measurement_duration = int(self._measurement_duration)
        else:
            self._measurement_duration = None

        # Read the XFER_TIMEOUT from UseCase xml Parameter
        self._xfer_timeout = self._tc_parameters.get_param_value(
            "XFER_TIMEOUT")
        if isinstance(self._xfer_timeout,
                      str) and self._xfer_timeout.isdigit():
            self._xfer_timeout = int(self._xfer_timeout)
        else:
            self._xfer_timeout = None

        # Read the FAILURE_OTATX from UseCase xml Parameter
        self._failure_throughput_dict = {}

        failure_targets = self._tc_parameters.get_param_value("FAILURE_TARGETS").\
            replace(" ", "").split(",")

        for failure in failure_targets:
            self._failure_throughput_dict.update(
                {str(failure.split(":")[0]): float(failure.split(":")[1])})

        self._wait_time_before_measure = 5

        # Read PHONE_NUMBER from testcase xml parameters
        if (self._tc_parameters.get_param_value("PHONE_NUMBER") not in (None, '')) \
                and str(self._tc_parameters.get_param_value("PHONE_NUMBER")).isdigit():
            self._phone_number = self._tc_parameters.get_param_value(
                "PHONE_NUMBER")
        else:
            self._phone_number = str(self._device.get_phone_number())

        self._call_duration = \
            self._tc_parameters.get_param_value("CALL_DURATION")
        if isinstance(self._call_duration,
                      str) and self._call_duration.isdigit():
            self._call_duration = int(self._call_duration)
        else:
            self._call_duration = None

        self._call_setup_timeout = \
            int(self._dut_config.get("callSetupTimeout"))

        self._voicecall_api = self._device.get_uecmd("VoiceCall")

        # Create cellular network simulator and retrieve 3G API
        self._ns_cell_3g = self._ns.get_cell_3g()
        self._ns_voice_call_3g = self._ns_cell_3g.get_voice_call()

        # Get UECmdLayer for VoiceCall
        self._voicecall_api = self._device.get_uecmd("VoiceCall")
コード例 #4
0
    def run_test(self):
        """
        Execute the test
        """

        # Call LabHspaBase Run function
        LabHspaBase.run_test(self)

        result = Global.SUCCESS
        measure_throughput_msg = "Measured throughput:"
        failure_throughput_msg = "Failure throughput:"

        # Start to search the trigger_msg in the logcat log
        self._device_logger = self._device.get_device_logger()
        self._start_ftp_trigger_msg = "status::SUCCESS - output::RECEIVED - function::startFtpXfer"
        self._device_logger.add_trigger_message(self._start_ftp_trigger_msg)

        self._logger.info("FTP transfer " + str(self._ftp_direction) +
                          " for " + str(self._ftp_filename) + "...")

        self._ftp_task_id = self._networking_api.start_ftp_xfer(
            self._ftp_direction, self._server_ip_address, self._username,
            self._password, self._ftp_filename, self._device.get_ftpdir_path())

        # Get the ftp start log msg and retrieve the OP code from the message
        self._op_code_message = self._device_logger.get_message_triggered_status(
            self._start_ftp_trigger_msg)
        self._device_logger.remove_trigger_message(self._start_ftp_trigger_msg)
        self._op_code = re.findall(r'ACS\_\d*', str(self._op_code_message))[0]

        self._logger.info(
            "Wait %d seconds for ensure that transfer is established" %
            self._wait_time_before_measure)
        time.sleep(self._wait_time_before_measure)

        self._voicecall_api.dial(self._phone_number)

        # Check call state "CONNECTED" before callSetupTimeout seconds
        self._ns_voice_call_3g.check_call_connected(self._call_setup_timeout)

        self._logger.info(
            "Wait %d seconds for ensure that transfer is stable" %
            self._wait_time_before_measure)
        time.sleep(self._wait_time_before_measure)

        data_throughput_dict = self._ns.get_data_throughput(
            self._measurement_duration, self._failure_throughput_dict.keys())

        # Check call is connected for CALL_DURATION seconds
        self._ns_voice_call_3g.is_voice_call_connected(self._call_duration)

        # Release the voice call
        self._ns_voice_call_3g.voice_call_network_release()

        self._timeout = self._xfer_timeout - self._wait_time_before_measure - self._call_duration

        self._device_logger.add_trigger_message(self._op_code)

        # Create success_msg to check ftp transfers finish success
        ftp_filename = os.path.split(self._ftp_filename)[1]
        success_msg = "Ftp %s of file %s finish success" % (
            self._ftp_direction, ftp_filename)

        # Wait to ftp imeout to verify ftp transfers finish success
        while self._timeout > 0:
            triggered_status = self._device_logger.get_message_triggered_status(
                self._op_code)
            # When the  success message  is in the message of ACS op code
            if success_msg in str(triggered_status):
                self._logger.info(str(triggered_status))
                break
            else:
                time.sleep(1)
                self._timeout -= 1
        else:
            self._device_logger.remove_trigger_message(self._op_code)
            self._networking_api.stop_ftp_xfer(self._ftp_task_id)
            self._error.Msg = "The FTP transfer doesn't finish in the timeout"
            raise DeviceException(DeviceException.TIMEOUT_REACHED,
                                  self._error.Msg)

        for data_type in data_throughput_dict.keys():

            if "Mbps" in data_throughput_dict[data_type][0]:
                # Convert to Mbps for result compare
                if float(data_throughput_dict[data_type][0]
                         [0:-4]) < self._failure_throughput_dict[data_type]:
                    result = Global.FAILURE
            elif "Kbps" in data_throughput_dict[data_type][0]:
                if float(data_throughput_dict[data_type][0][0:-4]
                         ) < self._failure_throughput_dict[data_type] * 1000:
                    result = Global.FAILURE
            elif "bps" in data_throughput_dict[data_type][0]:
                if float(
                        data_throughput_dict[data_type][0][0:-4]
                ) < self._failure_throughput_dict[data_type] * 1000 * 1000:
                    result = Global.FAILURE
            else:
                self._error.Msg = "unknown measure result unit: %s " % str(
                    data_throughput_dict[data_type][0])
                raise TestEquipmentException(
                    TestEquipmentException.PROHIBITIVE_MEASURE,
                    self._error.Msg)

            measure_throughput_msg = measure_throughput_msg + str(data_type)\
                + ":" + str(data_throughput_dict[data_type][0]) + " "
            failure_throughput_msg = failure_throughput_msg + str(data_type)\
                + ":" + str(self._failure_throughput_dict[data_type]) + "Mbps" + " "

        self._error.Msg = measure_throughput_msg + "- " + failure_throughput_msg

        return result, self._error.Msg
コード例 #5
0
 def tear_down(self):
     AnyUsbTether.tear_down(self)
     return LabHspaBase.tear_down(self)
コード例 #6
0
 def run_test(self):
     (code, message) = LabHspaBase.run_test(self)
     if code == Global.SUCCESS:
         (code, message) = AnyUsbTether.run_test(self)
     return code, message
コード例 #7
0
 def set_up(self):
     (code, message) = LabHspaBase.set_up(self)
     if code == Global.SUCCESS:
         (code, message) = AnyUsbTether.set_up(self)
     return code, message