def setup_pipeline_network(self, fluid_list): """Setup a pipeline network.""" self.nw = network(fluids=fluid_list) self.nw.set_attr(p_unit='bar', T_unit='C', iterinfo=False) # %% components # main components pu = pump('pump') pi = pipe('pipeline') es = heat_exchanger_simple('energy balance closing') closer = cycle_closer('cycle closer') pu_pi = connection(pu, 'out1', pi, 'in1') pi_es = connection(pi, 'out1', es, 'in1') es_closer = connection(es, 'out1', closer, 'in1') closer_pu = connection(closer, 'out1', pu, 'in1') self.nw.add_conns(pu_pi, pi_es, es_closer, closer_pu) # %% parametrization of components pu.set_attr(eta_s=0.7) pi.set_attr(pr=0.95, L=100, ks=1e-5, D='var', Q=0) es.set_attr(pr=1) # %% parametrization of connections pu_pi.set_attr(p=20, T=100, m=10, fluid={self.nw.fluids[0]: 1}) # %% solving self.nw.solve('design')
def setup_clausius_rankine(self, fluid_list): """Setup a Clausius-Rankine cycle.""" self.nw = network(fluids=fluid_list) self.nw.set_attr(p_unit='bar', T_unit='C', iterinfo=False) # %% components # main components turb = turbine('turbine') con = condenser('condenser') pu = pump('pump') steam_generator = heat_exchanger_simple('steam generator') closer = cycle_closer('cycle closer') # cooling water so_cw = source('cooling water inlet') si_cw = sink('cooling water outlet') # %% connections # main cycle fs_in = connection(closer, 'out1', turb, 'in1', label='livesteam') ws = connection(turb, 'out1', con, 'in1', label='wastesteam') cond = connection(con, 'out1', pu, 'in1', label='condensate') fw = connection(pu, 'out1', steam_generator, 'in1', label='feedwater') fs_out = connection(steam_generator, 'out1', closer, 'in1') self.nw.add_conns(fs_in, ws, cond, fw, fs_out) # cooling water cw_in = connection(so_cw, 'out1', con, 'in2') cw_out = connection(con, 'out2', si_cw, 'in1') self.nw.add_conns(cw_in, cw_out) # %% parametrization of components turb.set_attr(eta_s=0.9) con.set_attr(pr1=1, pr2=0.99, ttd_u=5) pu.set_attr(eta_s=0.7) steam_generator.set_attr(pr=0.9) # %% parametrization of connections fs_in.set_attr(p=100, T=500, m=100, fluid={self.nw.fluids[0]: 1}) cw_in.set_attr(T=20, p=5, fluid={self.nw.fluids[0]: 1}) cw_out.set_attr(T=30) # %% solving self.nw.solve('design')
def __init__(self, working_fluid): self.working_fluid = working_fluid fluids = ['water', self.working_fluid, 'air'] self.nw = network(fluids=fluids) self.nw.set_attr(p_unit='bar', T_unit='C', h_unit='kJ / kg') # geo parameters geo_mass_flow = 210 geo_steam_share = 0.1 T_brine_in = 144.8 T_reinjection = 70.8 # ambient parameters T_amb = 0 p_amb = 1 # main components geo_steam = source('steam source') geo_brine = source('brine source') geo_reinjection = sink('reinjection well') air_in = source('ambient air source') air_out = sink('ambient air sink') air_cond = condenser('main condenser') orc_cc = cycle_closer('orc cycle closer') evap_steam = condenser('steam evaporator') evap_splitter = splitter('splitter evaporation') evap_merge = merge('merge evaporation') evap_steam = condenser('steam evaporator') geo_steam_pump = pump('geosteam condensate pump') evap_brine = heat_exchanger('brine evaporator') dr = drum('drum') eco = heat_exchanger('economiser') feed_water_pump = pump('feed water pump') geo_merge = merge('brine merge') tur = turbine('turbine') ls_valve = valve('live steam valve') ihe = heat_exchanger('internal heat exchanger') # busses power_bus = bus('power output') power_bus.add_comps({ 'c': tur, 'char': -1 }, { 'c': feed_water_pump, 'char': -1 }, { 'c': geo_steam_pump, 'char': -1 }) geothermal_bus = bus('thermal input') geothermal_bus.add_comps({ 'c': eco, 'char': -1 }, { 'c': evap_brine, 'char': -1 }, { 'c': evap_steam, 'char': -1 }) self.nw.add_busses(power_bus, geothermal_bus) # turbine to condenser ls_in = connection(orc_cc, 'out1', ls_valve, 'in1') lsv_tur = connection(ls_valve, 'out1', tur, 'in1') tur_ihe = connection(tur, 'out1', ihe, 'in1') ihe_cond = connection(ihe, 'out1', air_cond, 'in1') self.nw.add_conns(ls_in, lsv_tur, tur_ihe, ihe_cond) # condenser to steam generator cond_fwp = connection(air_cond, 'out1', feed_water_pump, 'in1') fwp_ihe = connection(feed_water_pump, 'out1', ihe, 'in2') self.nw.add_conns(cond_fwp, fwp_ihe) # steam generator ihe_eco = connection(ihe, 'out2', eco, 'in2') eco_dr = connection(eco, 'out2', dr, 'in1') dr_esp = connection(dr, 'out1', evap_splitter, 'in1') esp_eb = connection(evap_splitter, 'out1', evap_brine, 'in2') esp_es = connection(evap_splitter, 'out2', evap_steam, 'in2') eb_em = connection(evap_brine, 'out2', evap_merge, 'in1') es_em = connection(evap_steam, 'out2', evap_merge, 'in2') em_dr = connection(evap_merge, 'out1', dr, 'in2') ls_out = connection(dr, 'out2', orc_cc, 'in1') self.nw.add_conns(ihe_eco, eco_dr, dr_esp, esp_eb, esp_es, eb_em, es_em, em_dr, ls_out) # air cold side air_cold = connection(air_in, 'out1', air_cond, 'in2') air_hot = connection(air_cond, 'out2', air_out, 'in1') self.nw.add_conns(air_cold, air_hot) # geo source gs_es = connection(geo_steam, 'out1', evap_steam, 'in1', label='geosteam') es_gsp = connection(evap_steam, 'out1', geo_steam_pump, 'in1') gsp_gm = connection(geo_steam_pump, 'out1', geo_merge, 'in1') gb_eb = connection(geo_brine, 'out1', evap_brine, 'in1', label='geobrine') eb_gm = connection(evap_brine, 'out1', geo_merge, 'in2') self.nw.add_conns(gs_es, es_gsp, gsp_gm, gb_eb, eb_gm) gm_eco = connection(geo_merge, 'out1', eco, 'in1') eco_gr = connection(eco, 'out1', geo_reinjection, 'in1', label='reinjection') self.nw.add_conns(gm_eco, eco_gr) # fluid settings ihe_eco.set_attr(fluid={self.working_fluid: 1, 'air': 0, 'water': 0}) air_cold.set_attr(fluid={self.working_fluid: 0, 'air': 1, 'water': 0}) gs_es.set_attr(fluid={self.working_fluid: 0, 'air': 0, 'water': 1}) gb_eb.set_attr(fluid={self.working_fluid: 0, 'air': 0, 'water': 1}) # connection parameters ls_stable_p0 = PSI('P', 'T', T_brine_in + 273.15, 'Q', 1, self.working_fluid) / 1e5 lsv_tur.set_attr(p0=ls_stable_p0) ws_stable_h0 = ( PSI('H', 'T', T_amb + 273.15, 'Q', 1, self.working_fluid) + 0.5 * (PSI('H', 'T', T_brine_in + 273.15, 'Q', 1, self.working_fluid) - PSI('H', 'T', T_amb + 273.15, 'Q', 1, self.working_fluid))) / 1e3 tur_ihe.set_attr(h=ws_stable_h0) ihe_cond.set_attr( Td_bp=2, design=['Td_bp'], p0=PSI('P', 'T', T_amb + 273.15, 'Q', 1, self.working_fluid) / 1e5) fwp_ihe.set_attr(h=ref(cond_fwp, 1, 1e3)) # steam generator gs_es.set_attr(m=geo_mass_flow * geo_steam_share, T=T_brine_in, x=1, p0=5) gb_eb.set_attr(m=geo_mass_flow * (1 - geo_steam_share), T=T_brine_in, x=0) em_dr.set_attr() eb_em.set_attr(x=0.5) es_em.set_attr(x=0.5, design=['x']) eb_gm.set_attr(T=T_brine_in - 20) eco_dr.set_attr(Td_bp=-2) # main condenser air_cold.set_attr(p=p_amb, T=T_amb) air_hot.set_attr(T=15) # component parameters # turbines tur.set_attr(design=['eta_s'], offdesign=['cone', 'eta_s_char']) ls_valve.set_attr(pr=1, design=['pr']) # condensing ihe.set_attr(pr1=1, pr2=1, offdesign=['kA_char']) air_cond.set_attr(pr1=1, pr2=1, ttd_u=10, design=['ttd_u'], offdesign=['kA_char']) feed_water_pump.set_attr(design=['eta_s'], offdesign=['eta_s_char']) # steam generator evap_steam.set_attr( pr1=0.99, offdesign=['kA_char']) # no pr2 due to drum pressure balance evap_brine.set_attr( pr1=1, ttd_l=10, offdesign=['kA_char']) # no pr2 due to drum pressure balance eco.set_attr(pr1=1, pr2=1) geo_steam_pump.set_attr(eta_s=0.75, design=['eta_s'], offdesign=['eta_s_char']) self.nw.set_attr(iterinfo=False) self.nw.solve('design') self.nw.print_results() tur.set_attr(eta_s=0.9) feed_water_pump.set_attr(eta_s=0.75) tur_ihe.set_attr(h=None) fwp_ihe.set_attr(h=None) eb_gm.set_attr(T=None)
import numpy as np import pandas as pd # %% network nw = network(fluids=['water', 'NH3', 'air'], T_unit='C', p_unit='bar', h_unit='kJ / kg', m_unit='kg / s') # %% components # sources & sinks cc = cycle_closer('coolant cycle closer') cb = source('consumer back flow') cf = sink('consumer feed flow') amb = source('ambient air') amb_out1 = sink('sink ambient 1') amb_out2 = sink('sink ambient 2') # ambient air system sp = splitter('splitter') fan = compressor('fan') # consumer system cd = condenser('condenser') dhp = pump('district heating pump') cons = heat_exchanger_simple('consumer')
'Isopentane') / 1e5 p_steam_in = PropsSI('P', 'T', T_brine_in + 273.15, 'Q', 1, 'water') / 1e5 # main components evaporator = evaporator('evaporator') pump_c = pump('condensate pump') merge = merge('geo-fluid merge point') preheater = heat_exchanger('preheater') turbine = turbine('turbine') ihe = heat_exchanger('internal heat exchanger') condenser = condenser('condenser') pump = pump('feeding pump') # working fluid source_wf = source('working fluid source') sink_wf = sink('working fluid sink') close_cycle = cycle_closer('cycle closer before preheater') #brine source_s = source('steam source') source_b = source('brine source') sink_s = sink('steam sink') sink_b = sink('brine sink') # cooling air source_ca = source('cooling air source') sink_ca = sink('cooling air sink') # connections # main cycle preheater_wf_in = connection(close_cycle, 'out1', preheater, 'in2') preheater_evaporator = connection(preheater, 'out2', evaporator, 'in3') evaporator_turbine = connection(evaporator, 'out3', turbine, 'in1') turbine_ihe = connection(turbine, 'out1', ihe, 'in1')
def __init__(self): self.nw = network( fluids=['BICUBIC::water'], p_unit='bar', T_unit='C', h_unit='kJ / kg', iterinfo=False) # components # main cycle eco = heat_exchanger_simple('economizer') eva = heat_exchanger_simple('evaporator') sup = heat_exchanger_simple('superheater') cc = cycle_closer('cycle closer') hpt = turbine('high pressure turbine') sp1 = splitter('splitter 1', num_out=2) mpt = turbine('mid pressure turbine') sp2 = splitter('splitter 2', num_out=2) lpt = turbine('low pressure turbine') con = condenser('condenser') pu1 = pump('feed water pump') fwh1 = condenser('feed water preheater 1') fwh2 = condenser('feed water preheater 2') dsh = desuperheater('desuperheater') me2 = merge('merge2', num_in=2) pu2 = pump('feed water pump 2') pu3 = pump('feed water pump 3') me = merge('merge', num_in=2) # cooling water cwi = source('cooling water source') cwo = sink('cooling water sink') # connections # main cycle cc_hpt = connection(cc, 'out1', hpt, 'in1', label='feed steam') hpt_sp1 = connection(hpt, 'out1', sp1, 'in1', label='extraction1') sp1_mpt = connection(sp1, 'out1', mpt, 'in1', state='g') mpt_sp2 = connection(mpt, 'out1', sp2, 'in1', label='extraction2') sp2_lpt = connection(sp2, 'out1', lpt, 'in1') lpt_con = connection(lpt, 'out1', con, 'in1') con_pu1 = connection(con, 'out1', pu1, 'in1') pu1_fwh1 = connection(pu1, 'out1', fwh1, 'in2') fwh1_me = connection(fwh1, 'out2', me, 'in1', state='l') me_fwh2 = connection(me, 'out1', fwh2, 'in2', state='l') fwh2_dsh = connection(fwh2, 'out2', dsh, 'in2', state='l') dsh_me2 = connection(dsh, 'out2', me2, 'in1') me2_eco = connection(me2, 'out1', eco, 'in1', state='l') eco_eva = connection(eco, 'out1', eva, 'in1') eva_sup = connection(eva, 'out1', sup, 'in1') sup_cc = connection(sup, 'out1', cc, 'in1') self.nw.add_conns(cc_hpt, hpt_sp1, sp1_mpt, mpt_sp2, sp2_lpt, lpt_con, con_pu1, pu1_fwh1, fwh1_me, me_fwh2, fwh2_dsh, dsh_me2, me2_eco, eco_eva, eva_sup, sup_cc) # cooling water cwi_con = connection(cwi, 'out1', con, 'in2') con_cwo = connection(con, 'out2', cwo, 'in1') self.nw.add_conns(cwi_con, con_cwo) # preheating sp1_dsh = connection(sp1, 'out2', dsh, 'in1') dsh_fwh2 = connection(dsh, 'out1', fwh2, 'in1') fwh2_pu2 = connection(fwh2, 'out1', pu2, 'in1') pu2_me2 = connection(pu2, 'out1', me2, 'in2') sp2_fwh1 = connection(sp2, 'out2', fwh1, 'in1') fwh1_pu3 = connection(fwh1, 'out1', pu3, 'in1') pu3_me = connection(pu3, 'out1', me, 'in2') self.nw.add_conns(sp1_dsh, dsh_fwh2, fwh2_pu2, pu2_me2, sp2_fwh1, fwh1_pu3, pu3_me) # busses # power bus self.power = bus('power') self.power.add_comps( {'comp': hpt, 'char': -1}, {'comp': mpt, 'char': -1}, {'comp': lpt, 'char': -1}, {'comp': pu1, 'char': -1}, {'comp': pu2, 'char': -1}, {'comp': pu3, 'char': -1}) # heating bus self.heat = bus('heat') self.heat.add_comps( {'comp': eco, 'char': 1}, {'comp': eva, 'char': 1}, {'comp': sup, 'char': 1}) self.nw.add_busses(self.power, self.heat) # parametrization # components hpt.set_attr(eta_s=0.9) mpt.set_attr(eta_s=0.9) lpt.set_attr(eta_s=0.9) pu1.set_attr(eta_s=0.8) pu2.set_attr(eta_s=0.8) pu3.set_attr(eta_s=0.8) eco.set_attr(pr=0.99) eva.set_attr(pr=0.99) sup.set_attr(pr=0.99) con.set_attr(pr1=0.99, pr2=0.99, ttd_u=5) fwh1.set_attr(pr1=0.99, pr2=0.99, ttd_u=5) fwh2.set_attr(pr1=0.99, pr2=0.99, ttd_u=5) dsh.set_attr(pr1=0.99, pr2=0.99) # connections eco_eva.set_attr(x=0) eva_sup.set_attr(x=1) cc_hpt.set_attr(m=200, T=650, p=100, fluid={'water': 1}) hpt_sp1.set_attr(p=20) mpt_sp2.set_attr(p=3) lpt_con.set_attr(p=0.05) cwi_con.set_attr(T=20, p=10, fluid={'water': 1})
ihe = heat_exchanger('internal heat exchanger') pump = pump('feeding pump') turbine = turbine('turbine') preh = heat_exchanger('preheater') evap = heat_exchanger('evaporator') # cooling air source_ca = source('cooling air source') sink_ca = sink('cooling air sink') #brine source_b = source('brine source') sink_b = sink('brine sink') # working fluid close_cycle = cycle_closer('cycle closer before turbine') # connections # main cycle turbine_wf_in = connection(close_cycle, 'out1', turbine, 'in1') turbine_ihe = connection(turbine, 'out1', ihe, 'in1') ihe_condenser = connection(ihe, 'out1', condenser, 'in1') condenser_pump = connection(condenser, 'out1', pump, 'in1') pump_ihe = connection(pump, 'out1', ihe, 'in2') ihe_preh = connection(ihe, 'out2', preh, 'in2') preh_evap = connection(preh, 'out2', evap, 'in2') evap_wf_out = connection(evap, 'out2', close_cycle, 'in1') nw.add_conns(turbine_wf_in, turbine_ihe, ihe_condenser, condenser_pump, pump_ihe, ihe_preh, preh_evap, evap_wf_out) # geo-fluid brine_in = connection(source_b, 'out1', evap, 'in1')
from tespy.networks import network from tespy.components import (source, sink, condenser, pump, heat_exchanger_simple, cycle_closer) from tespy.connections import connection, ref # %% network nw = network(fluids=['water', 'NH3'], T_unit='C', p_unit='bar', h_unit='kJ / kg', m_unit='kg / s') # %% components # sources & sinks c_in = source('coolant in') cons_closer = cycle_closer('consumer cycle closer') va = sink('valve') # consumer system cd = condenser('condenser') rp = pump('recirculation pump') cons = heat_exchanger_simple('consumer') # %% connections # consumer system c_in_cd = connection(c_in, 'out1', cd, 'in1')
CH4 = source('fuel source') air = source('ambient air') # waste heat recovery suph = heat_exchanger('superheater') evap = heat_exchanger('evaporator') dr = drum('drum') eco = heat_exchanger('economizer') dh_whr = heat_exchanger('waste heat recovery') ch = sink('chimney') # steam turbine part turb = turbine('steam turbine') cond = condenser('condenser') pu = pump('feed water pump') cc = cycle_closer('ls cycle closer') # district heating dh_in = source('district heating backflow') dh_out = sink('district heating feedflow') # %% connections # gas turbine part c_in = connection(air, 'out1', comp, 'in1') c_out = connection(comp, 'out1', c_c, 'in1') fuel = connection(CH4, 'out1', c_c, 'in2') gt_in = connection(c_c, 'out1', g_turb, 'in1') gt_out = connection(g_turb, 'out1', suph, 'in1') nw.add_conns(c_in, c_out, fuel, gt_in, gt_out)
sink, pump, splitter, merge, heat_exchanger_simple, cycle_closer, ) from tespy.tools import char_line, dc_cc import numpy as np # %% network btes = network(fluids=["water"], T_unit="K", p_unit="bar", h_unit="kJ / kg") # %% components fc = cycle_closer("cycle closer") pu = pump("pump") sp = splitter("splitter", num_out=3) # bhe: bhe1 = heat_exchanger_simple("BHE1") bhe2 = heat_exchanger_simple("BHE2") bhe3 = heat_exchanger_simple("BHE3") mg = merge("merge", num_in=3) cons = heat_exchanger_simple("consumer") ## components paramerization # pump # flow_char # provide volumetric flow in m^3 / s
from tespy.tools.characteristics import load_default_char as ldc from tespy.tools.characteristics import char_line # %% network nw = network(fluids=['water', 'NH3'], T_unit='C', p_unit='bar', h_unit='kJ / kg', m_unit='kg / s') # %% components # sources & sinks cool_closer = cycle_closer('coolant cycle closer') cons_closer = cycle_closer('consumer cycle closer') amb_in = source('source ambient') amb_out = sink('sink ambient') ic_in = source('source intercool') ic_out = sink('sink intercool') # consumer system cd = condenser('condenser') rp = pump('recirculation pump') cons = heat_exchanger_simple('consumer') cp1 = sink('compressor 1')
combustion_chamber = combustion_chamber('combustion chamber') fuel_source = source('fuel source') gas_turbine = turbine('gas turbine') steam_generator = heat_exchanger('steamgenerator') exhaust_gas = sink('exhaust gas') # steam turbine part fs_source = source('steam source') steam_turbine = turbine('steam turbine') dh_heat_exchanger = heat_exchanger('district heating heat exchanger') pump = pump('pump') fs_sink = sink('steam sink') steam_cycle_closer = cycle_closer('steam cycle closer') # district heating part dh_source = source('district heating source') dh_sink = sink('district heating sink') # %% connections # gas turbine part air_source.air_compressor = connection(air_source, 'out1', air_compressor, 'in1') air_compressor.combustion_chamber = connection(air_compressor, 'out1', combustion_chamber, 'in1') combustion_chamber.gas_turbine = connection(combustion_chamber, 'out1', gas_turbine, 'in1') gas_turbine.steam_generator = connection(gas_turbine, 'out1', steam_generator,
class HeatPump(object): # define the structure of heat pump # %% network nw = network(fluids=['water', 'NH3', 'air'], T_unit='C', p_unit='bar', h_unit='kJ / kg', m_unit='kg / s') # %% components # sources & sinks cc = cycle_closer('coolant cycle closer') cb = source('consumer back flow') cf = sink('consumer feed flow') amb = source('ambient air') amb_out1 = sink('sink ambient 1') amb_out2 = sink('sink ambient 2') # ambient air system sp = splitter('splitter') pu = pump('pump') # consumer system cd = condenser('condenser') dhp = pump('district heating pump') cons = heat_exchanger_simple('consumer') # evaporator system ves = valve('valve') dr = drum('drum') ev = heat_exchanger('evaporator') su = heat_exchanger('superheater') erp = pump('evaporator reciculation pump') # compressor-system cp1 = compressor('compressor 1') cp2 = compressor('compressor 2') ic = heat_exchanger('intercooler') # %% connections # consumer system c_in_cd = connection(cc, 'out1', cd, 'in1') cb_dhp = connection(cb, 'out1', dhp, 'in1') dhp_cd = connection(dhp, 'out1', cd, 'in2') cd_cons = connection(cd, 'out2', cons, 'in1') cons_cf = connection(cons, 'out1', cf, 'in1') nw.add_conns(c_in_cd, cb_dhp, dhp_cd, cd_cons, cons_cf) # connection condenser - evaporator system cd_ves = connection(cd, 'out1', ves, 'in1') nw.add_conns(cd_ves) # evaporator system ves_dr = connection(ves, 'out1', dr, 'in1') dr_erp = connection(dr, 'out1', erp, 'in1') erp_ev = connection(erp, 'out1', ev, 'in2') ev_dr = connection(ev, 'out2', dr, 'in2') dr_su = connection(dr, 'out2', su, 'in2') nw.add_conns(ves_dr, dr_erp, erp_ev, ev_dr, dr_su) amb_p = connection(amb, 'out1', pu, 'in1') p_sp = connection(pu, 'out1', sp, 'in1') sp_su = connection(sp, 'out1', su, 'in1') su_ev = connection(su, 'out1', ev, 'in1') ev_amb_out = connection(ev, 'out1', amb_out1, 'in1') nw.add_conns(amb_p, p_sp, sp_su, su_ev, ev_amb_out) # connection evaporator system - compressor system su_cp1 = connection(su, 'out2', cp1, 'in1') nw.add_conns(su_cp1) # compressor-system cp1_he = connection(cp1, 'out1', ic, 'in1') he_cp2 = connection(ic, 'out1', cp2, 'in1') cp2_c_out = connection(cp2, 'out1', cc, 'in1') sp_ic = connection(sp, 'out2', ic, 'in2') ic_out = connection(ic, 'out2', amb_out2, 'in1') nw.add_conns(cp1_he, he_cp2, sp_ic, ic_out, cp2_c_out) def __init__(self, q, eff, Temp): r""" :param Temp: :param q: q output :param eff: efficient of each part in pump """ self.q = q self.eff = eff self.Temp = Temp def caculation(self): self.set_attr() HeatPump.nw.solve('design') P = [ HeatPump.cp1.P.val, HeatPump.cp2.P.val, HeatPump.erp.P.val, HeatPump.pu.P.val ] P_total = sum(map(abs, P)) P = list(map(abs, P)) COP = self.q / P_total # T = [HeatPump.su_cp1.T.val, HeatPump.cp2_c_out.T.val, HeatPump.cd_ves.T.val, HeatPump.su_ev.T.val] # p = [HeatPump.su_cp1.p.val, HeatPump.cp2_c_out.p.val, HeatPump.cd_ves.p.val, HeatPump.su_ev.p.val, # HeatPump.cp1_he.p.val] return P, P_total, COP def set_attr(self): r""" # %% set the attribution of the heat pump :return: heat output of the heat pump """ HeatPump.cd.set_attr(pr1=0.99, pr2=0.99, ttd_u=15, design=['pr2', 'ttd_u'], offdesign=['zeta2', 'kA']) HeatPump.dhp.set_attr(eta_s=self.eff, design=['eta_s'], offdesign=['eta_s_char']) HeatPump.cons.set_attr(pr=0.99, design=['pr'], offdesign=['zeta']) # water pump HeatPump.pu.set_attr(eta_s=self.eff, design=['eta_s'], offdesign=['eta_s_char']) # evaporator system kA_char1 = ldc('heat exchanger', 'kA_char1', 'DEFAULT', char_line) kA_char2 = ldc('heat exchanger', 'kA_char2', 'EVAPORATING FLUID', char_line) HeatPump.ev.set_attr(pr1=0.98, pr2=0.99, ttd_l=5, kA_char1=kA_char1, kA_char2=kA_char2, design=['pr1', 'ttd_l'], offdesign=['zeta1', 'kA']) HeatPump.su.set_attr(pr1=0.98, pr2=0.99, ttd_u=2, design=['pr1', 'pr2', 'ttd_u'], offdesign=['zeta1', 'zeta2', 'kA']) HeatPump.erp.set_attr(eta_s=self.eff, design=['eta_s'], offdesign=['eta_s_char']) # compressor system HeatPump.cp1.set_attr(eta_s=self.eff, design=['eta_s'], offdesign=['eta_s_char']) HeatPump.cp2.set_attr(eta_s=self.eff, pr=3, design=['eta_s'], offdesign=['eta_s_char']) HeatPump.ic.set_attr(pr1=0.99, pr2=0.98, design=['pr1', 'pr2'], offdesign=['zeta1', 'zeta2', 'kA']) # %% connection parametrization # condenser system HeatPump.c_in_cd.set_attr(fluid={'air': 0, 'NH3': 1, 'water': 0}) HeatPump.cb_dhp.set_attr(T=20, p=10, fluid={ 'air': 0, 'NH3': 0, 'water': 1 }) HeatPump.cd_cons.set_attr(T=self.Temp) HeatPump.cons_cf.set_attr(h=ref(HeatPump.cb_dhp, 1, 0), p=ref(HeatPump.cb_dhp, 1, 0)) # evaporator system cold side HeatPump.erp_ev.set_attr(m=ref(HeatPump.ves_dr, 1.25, 0), p0=5) HeatPump.su_cp1.set_attr(p0=5, h0=1700) # evaporator system hot side # pumping at constant rate in partload HeatPump.amb_p.set_attr(T=12, p=2, fluid={ 'air': 0, 'NH3': 0, 'water': 1 }, offdesign=['v']) HeatPump.sp_su.set_attr(offdesign=['v']) HeatPump.ev_amb_out.set_attr(p=2, T=9, design=['T']) # compressor-system HeatPump.he_cp2.set_attr(Td_bp=5, p0=20, design=['Td_bp']) HeatPump.ic_out.set_attr(T=15, design=['T']) # %% key paramter HeatPump.cons.set_attr(Q=self.q)
# See accompanying file LICENSE.txt or # http://www.opengeosys.org/project/license ### # Execute this file to generate TESPy network csv files from tespy.networks import network from tespy.connections import connection, ref from tespy.components import source, sink, pump, splitter, merge, heat_exchanger_simple, cycle_closer from tespy.tools import char_line, dc_cc import numpy as np # %% network btes = network(fluids=['water'], T_unit='K', p_unit='bar', h_unit='kJ / kg') # %% components fc = cycle_closer('cycle closer') pu = pump('pump') sp = splitter('splitter', num_out=3) # bhe: bhe1 = heat_exchanger_simple('BHE1') bhe2 = heat_exchanger_simple('BHE2') bhe3 = heat_exchanger_simple('BHE3') mg = merge('merge', num_in=3) cons = heat_exchanger_simple('consumer') ## components paramerization # pump # flow_char # provide volumetric flow in m^3 / s