def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) ports = '/dev/serial/by-id/' ports += 'usb-Prolific_Technology_Inc._USB-Serial_Controller_D-if00-port0' xgs_instance = xgs600.XGS600Driver(ports) print(xgs_instance.read_all_pressures()) pressure = PressureReader(xgs_instance) pressure.start() time.sleep(2.5) codenames = ['ps_qms_pressure', 'ps_chamber_pressure'] loggers = {} loggers[codenames[0]] = ValueLogger(pressure, comp_val=0.1, low_comp=1e-11, comp_type='log', channel=0) loggers[codenames[0]].start() loggers[codenames[1]] = ValueLogger(pressure, comp_val=0.1, low_comp=1e-11, comp_type='log', channel=1) loggers[codenames[1]].start() #livesocket = LiveSocket('PS', codenames, 2) #livesocket.start() socket = DateDataPullSocket('PS pressure logger', codenames, timeouts=2 * [1.0], port=9001) socket.start() db_logger = ContinuousDataSaver(continuous_data_table='dateplots_ps', username=credentials.user, password=credentials.passwd, measurement_codenames=codenames) db_logger.start() while pressure.isAlive(): time.sleep(0.5) for name in codenames: value = loggers[name].read_value() #livesocket.set_point_now(name, value) socket.set_point_now(name, value) if loggers[name].read_trigged(): print(value) db_logger.save_point_now(name, value) loggers[name].clear_trigged()
def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) port = 'serial/by-id/usb-1a86_USB2.0-Ser_-if00-port0' xgs = xgs600.XGS600Driver('/dev/' + port) print(xgs.read_all_pressures()) reader = PressureReader(xgs) reader.daemon = True reader.start() buffer_logger = ValueLogger(reader, comp_val=0.1, comp_type='log', channel=0, low_comp=1e-3) containment_logger = ValueLogger(reader, comp_val=0.1, comp_type='log', channel=1, low_comp=1e-3) buffer_logger.start() containment_logger.start() socket = DateDataPullSocket('mgw', ['containment_pressure', 'buffer_pressure'], timeouts=[1.0, 1.0]) socket.start() livesocket = LiveSocket('mgw', ['containment_pressure', 'buffer_pressure']) livesocket.start() codenames = ['mgw_pressure_containment', 'mgw_pressure_buffer'] db_logger = ContinuousDataSaver(continuous_data_table='dateplots_mgw', username=credentials.user, password=credentials.passwd, measurement_codenames=codenames) db_logger.start() time.sleep(5) while reader.isAlive(): time.sleep(0.2) p_containment = containment_logger.read_value() p_buffer = buffer_logger.read_value() socket.set_point_now('containment_pressure', p_containment) socket.set_point_now('buffer_pressure', p_buffer) livesocket.set_point_now('containment_pressure', p_containment) livesocket.set_point_now('buffer_pressure', p_buffer) if containment_logger.read_trigged(): print(p_containment) db_logger.save_point_now('mgw_pressure_containment', p_containment) containment_logger.clear_trigged() if buffer_logger.read_trigged(): print(p_buffer) db_logger.save_point_now('mgw_pressure_buffer', p_buffer) buffer_logger.clear_trigged()
def main(): """ Main code """ mux_instance = agilent_34972A.Agilent34972ADriver( interface='lan', hostname='volvo-agilent-34972a') port = '/dev/serial/by-id/usb-Prolific_Technology_Inc._USB-Serial_Controller-if00-port0' xgs_instance = xgs600.XGS600Driver(port) analog_measurement = MuxReader(mux_instance) analog_measurement.start() pressure = PressureReader(xgs_instance) print('-') pressure.start() time.sleep(2.5) codenames = ['volvo_pressure', 'volvo_temperature'] loggers = {} loggers[codenames[0]] = ValueLogger(pressure, comp_val=0.1, comp_type='log') loggers[codenames[0]].start() loggers[codenames[1]] = ValueLogger(analog_measurement, comp_val=0.5, comp_type='lin') loggers[codenames[1]].start() socket = DateDataPullSocket('Volvo data logger', codenames, timeouts=[1.0, 1.0]) socket.start() livesocket = LiveSocket('Volvo data logger', codenames) livesocket.start() db_logger = ContinuousDataSaver(continuous_data_table='dateplots_volvo', username=credentials.user, password=credentials.passwd, measurement_codenames=codenames) db_logger.start() #while pressure.isAlive() and analog_measurement.isAlive(): while True: time.sleep(0.25) for name in codenames: value = loggers[name].read_value() socket.set_point_now(name, value) livesocket.set_point_now(name, value) if loggers[name].read_trigged(): print(value) db_logger.save_point_now(name, value) loggers[name].clear_trigged()
def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) ports = '/dev/serial/by-id/usb-1a86_USB2.0-Ser_-if00-port0' xgs_instance = xgs600.XGS600Driver(ports) print(xgs_instance.read_all_pressures()) pressure = PressureReader(xgs_instance) pressure.start() time.sleep(2.5) codenames = ['tof_iongauge_ft', 'tof_iongauge_main', 'tof_pirani_roughing'] loggers = {} loggers[codenames[0]] = ValueLogger(pressure, comp_val=0.1, low_comp=1e-11, comp_type='log', channel=0) loggers[codenames[0]].start() loggers[codenames[1]] = ValueLogger(pressure, low_comp=1e-11, comp_val=0.1, comp_type='log', channel=1) loggers[codenames[1]].start() loggers[codenames[2]] = ValueLogger(pressure, comp_val=0.1, comp_type='log', channel=2) loggers[codenames[2]].start() livesocket = LiveSocket('TOF data logger', codenames) livesocket.start() db_logger = ContinuousDataSaver(continuous_data_table='dateplots_tof', username=credentials.user, password=credentials.passwd, measurement_codenames=codenames) db_logger.start() while pressure.isAlive(): time.sleep(0.5) for name in codenames: value = loggers[name].read_value() livesocket.set_point_now(name, value) if loggers[name].read_trigged(): print(value) db_logger.save_point_now(name, value) loggers[name].clear_trigged()
time.sleep(0.5) press = self.xgs.read_all_pressures() try: self.pressure = press[0] except IndexError: print("av") self.pressure = 0 logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) mux_instance = agilent_34972A.Agilent34972ADriver('volvo-agilent-34972a') #mux_instance = agilent_34972A.Agilent34972ADriver('10.54.6.144') xgs_instance = xgs600.XGS600Driver( '/dev/serial/by-id/usb-Prolific_Technology_Inc._USB-Serial_Controller-if00-port0' ) analog_measurement = MuxReader(mux_instance) analog_measurement.start() pressure = PressureReader(xgs_instance) pressure.start() time.sleep(2.5) codenames = ['volvo_pressure', 'volvo_temperature'] loggers = {} loggers[codenames[0]] = ValueLogger(pressure, comp_val=0.1, comp_type='log') loggers[codenames[0]].start() loggers[codenames[1]] = ValueLogger(analog_measurement,
def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) xgs_port = '/dev/serial/by-id/' xgs_port += 'usb-Prolific_Technology_Inc._USB-Serial_Controller_D-if00-port0' xgs_instance = xgs600.XGS600Driver(xgs_port) print(xgs_instance.read_all_pressures()) xgs_pressure = XgsReader(xgs_instance) xgs_pressure.start() time.sleep(2.5) codenames = [ 'pvd309_load_lock_ig', 'pvd309_load_lock_turbo_roughing', 'pvd309_load_lock_pirani', 'pvd309_main_chamber_ig', 'pvd309_cryo_roughing', 'pvd309_main_chamber_pirani' ] loggers = {} loggers[codenames[0]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-9, comp_type='log', channel=0) loggers[codenames[0]].start() loggers[codenames[1]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-3, comp_type='log', channel=1) loggers[codenames[1]].start() loggers[codenames[2]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-3, comp_type='log', channel=2) loggers[codenames[2]].start() loggers[codenames[3]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-9, comp_type='log', channel=3) loggers[codenames[3]].start() loggers[codenames[4]] = ValueLogger(xgs_pressure, comp_val=0.3, low_comp=1e-2, comp_type='log', channel=4) loggers[codenames[4]].start() loggers[codenames[5]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-3, comp_type='log', channel=5) loggers[codenames[5]].start() livesocket = LiveSocket('pvd309 pressure logger', codenames, 2) livesocket.start() socket = DateDataPullSocket('pvd309 pressure', codenames, timeouts=[1.0] * 6) socket.start() db_logger = ContinuousDataSaver(continuous_data_table='dateplots_pvd309', username=credentials.user, password=credentials.passwd, measurement_codenames=codenames) db_logger.start() while xgs_pressure.isAlive(): time.sleep(0.25) for name in codenames: value = loggers[name].read_value() livesocket.set_point_now(name, value) socket.set_point_now(name, value) if loggers[name].read_trigged(): print(name + ': ' + str(value)) db_logger.save_point_now(name, value) loggers[name].clear_trigged()
def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) omega = D6400.OmegaD6400( 1, '/dev/serial/by-id/' + 'usb-FTDI_USB-RS485_Cable_FTWECCJP-if00-port0') omega.update_range_and_function(1, action='tc', fullrange='K') omega.update_range_and_function(2, action='tc', fullrange='K') omega.update_range_and_function(3, action='tc', fullrange='K') omega.update_range_and_function(4, action='tc', fullrange='K') omega.update_range_and_function(5, action='tc', fullrange='K') omega.update_range_and_function(6, action='tc', fullrange='K') omega.update_range_and_function(7, action='tc', fullrange='K') xgs = xgs600.XGS600Driver( '/dev/serial/by-id/usb-Prolific_Technology_Inc.' + '_USB-Serial_Controller_D-if00-port0') print(xgs.read_all_pressures()) pressurereader = PressureReader(xgs) pressurereader.daemon = True pressurereader.start() tempreader = TemperatureReader(omega) tempreader.daemon = True tempreader.start() loggers = {} loggers['vhp_mass_spec_pressure'] = ValueLogger(pressurereader, comp_val=0.1, low_comp=1e-11, comp_type='log', channel=0) loggers['vhp_mass_spec_pressure'].start() loggers['vhp_pressure_pc_backside'] = ValueLogger(pressurereader, comp_val=0.1, low_comp=1e-3, comp_type='log', channel=1) loggers['vhp_pressure_pc_backside'].start() temp_codenames = [ 'vhp_T_reactor_inlet', 'vhp_T_reactor_outlet', 'vhp_T_reactor_top', 'vhp_T_mass_spec', 'vhp_T_gas_lines', 'vhp_T_purifying_reactor', 'vhp_T_furnace' ] for i in range(0, 7): loggers[temp_codenames[i]] = ValueLogger(tempreader, comp_val=0.2, comp_type='lin', channel=i + 1) loggers[temp_codenames[i]].start() all_codenames = ['vhp_mass_spec_pressure', 'vhp_pressure_pc_backside' ] + temp_codenames socket = DateDataPullSocket('vhp', all_codenames, timeouts=1.0) socket.start() db_logger = ContinuousDataSaver( continuous_data_table='dateplots_vhp_setup', username=credentials.user, password=credentials.passwd, measurement_codenames=all_codenames) db_logger.start() time.sleep(5) while tempreader.isAlive(): time.sleep(0.5) for name in all_codenames: value = loggers[name].read_value() if loggers[name].read_trigged(): print(value) db_logger.save_point_now(name, value) loggers[name].clear_trigged()
def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) xgs_port = '/dev/serial/by-id/usb-1a86_USB2.0-Ser_-if00-port0' xgs_instance = xgs600.XGS600Driver(xgs_port) print(xgs_instance.read_all_pressures()) kjlc_port = '/dev/serial/by-id/usb-Prolific_Technology_Inc._' kjlc_port += 'USB-Serial_Controller-if00-port0' kjlc_instance = kjlc.KJLC300(kjlc_port) xgs_pressure = XgsReader(xgs_instance) xgs_pressure.start() kjlc_pressure = PressureReader(kjlc_instance) kjlc_pressure.start() time.sleep(2.5) codenames = [ 'sniffer_qms_ion_gauge', 'sniffer_qms_roughing', 'sniffer_buffer_roughing', 'sniffer_buffer_pressure' ] loggers = {} loggers[codenames[0]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-8, comp_type='log', channel=0) loggers[codenames[0]].start() loggers[codenames[1]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-3, comp_type='log', channel=1) loggers[codenames[1]].start() loggers[codenames[2]] = ValueLogger(xgs_pressure, comp_val=0.1, low_comp=1e-3, comp_type='log', channel=2) loggers[codenames[2]].start() loggers[codenames[3]] = ValueLogger(kjlc_pressure, comp_val=0.1, comp_type='lin') loggers[codenames[3]].start() livesocket = LiveSocket('sniffer pressure logger', codenames, 2) livesocket.start() socket = DateDataPullSocket('sniffer pressure', codenames, timeouts=[1.0] * len(codenames)) socket.start() db_logger = ContinuousDataSaver(continuous_data_table='dateplots_sniffer', username=credentials.user, password=credentials.passwd, measurement_codenames=codenames) db_logger.start() while xgs_pressure.isAlive(): time.sleep(0.25) for name in codenames: value = loggers[name].read_value() livesocket.set_point_now(name, value) socket.set_point_now(name, value) if loggers[name].read_trigged(): print(name, value) db_logger.save_point_now(name, value) loggers[name].clear_trigged()
def main(): """ Main function """ logging.basicConfig(filename="logger.txt", level=logging.ERROR) logging.basicConfig(level=logging.ERROR) omega = D6400.OmegaD6400(1, '/dev/serial/by-id/' + 'usb-FTDI_USB-RS485_Cable_FTWECCJP-if00-port0') omega.update_range_and_function(1, action='tc', fullrange='K') omega.update_range_and_function(2, action='tc', fullrange='K') omega.update_range_and_function(3, action='tc', fullrange='K') omega.update_range_and_function(4, action='tc', fullrange='K') omega.update_range_and_function(5, action='tc', fullrange='K') omega.update_range_and_function(6, action='tc', fullrange='K') omega.update_range_and_function(7, action='tc', fullrange='K') xgs = xgs600.XGS600Driver('/dev/serial/by-id/usb-Prolific_Technology_Inc.' + '_USB-Serial_Controller_D-if00-port0') print(xgs.read_all_pressures()) pressurereader = PressureReader(xgs) pressurereader.daemon = True pressurereader.start() chamber_logger = PressureLogger(pressurereader, 0) chamber_logger.start() tempreader = TemperatureReader(omega) tempreader.daemon = True tempreader.start() temp_loggers = {} for i in range(0, 7): temp_loggers[i] = TemperatureLogger(tempreader, i + 1) temp_loggers[i].start() temp_codenames = ['vhp_T_reactor_inlet', 'vhp_T_reactor_outlet', 'vhp_T_reactor_top', 'vhp_T_mass_spec', 'vhp_T_gas_lines', 'vhp_T_purifying_reactor', 'vhp_T_furnace'] socket = DateDataPullSocket('vhp', ['vhp_mass_spec_pressure'] + temp_codenames, timeouts=[1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0]) socket.start() db_logger = ContinuousDataSaver(continuous_data_table='dateplots_vhp_setup', username=credentials.user, password=credentials.passwd, measurement_codenames=['vhp_mass_spec_pressure'] + temp_codenames) db_logger.start() time.sleep(5) while True: time.sleep(0.25) for i in range(0, 7): value = temp_loggers[i].read_value() socket.set_point_now(temp_codenames[i], value) if temp_loggers[i].trigged: print(value) db_logger.save_point_now(temp_codenames[i], value) temp_loggers[i].trigged = False value = chamber_logger.read_pressure() socket.set_point_now('vhp_mass_spec_pressure', value) if chamber_logger.trigged: print(value) db_logger.save_point_now('vhp_mass_spec_pressure', value) chamber_logger.trigged = False