예제 #1
0
    def test(self):
        '''
        Test
        '''
        error = []
        for pci_adres in pci.get_pci_addresses():
            print "Comparing for PCI Adress : ", pci_adres, "\n\n"
            vpd_output = pci.get_vpd(pci_adres)
            if vpd_output:
                '''
                Slot Match
                '''
                if vpd_output.has_key('slot'):
                    sys_slot = pci.get_slot_from_sysfs(pci_adres)
                    if sys_slot:
                        sys_slot = sys_slot.strip('\0')
                    vpd_slot = vpd_output['slot']
                    self.log.info("Slot from sysfs:%s", sys_slot)
                    self.log.info("Slot from lsvpd:%s", vpd_slot)
                    if sys_slot in [sys_slot, vpd_slot[:vpd_slot.rfind('-')]]:
                        self.log.info("=======>>> slot matches perfectly\n\n")
                    else:
                        error.append(pci_adres + "->slot")
                        self.log.info("--->>Slot Numbers not Matched\n\n")
                else:
                    self.log.error("Slot info not available in vpd output\n")
                '''
                Device ID match
                '''
                sys_pci_id_output = pci.get_pci_id_from_sysfs(pci_adres)
                vpd_device_id = vpd_output['pci_id'][4:]
                sysfs_device_id = sys_pci_id_output[5:-10]
                self.log.info("Device ID from sysfs :%s", sysfs_device_id)
                self.log.info("Device ID from vpd:%s", vpd_device_id)
                if vpd_device_id == sysfs_device_id:
                    self.log.info("=======>>Device ID Match Success\n\n")
                else:
                    self.log.error("----->>Device ID did not Match\n\n")
                    error.append(pci_adres + "->Device_id")
                '''
                Subvendor ID Match
                '''
                sysfs_subvendor_id = sys_pci_id_output[10:-5]
                vpd_subvendor_id = vpd_output['pci_id'][:4]
                self.log.info("Subvendor ID frm sysfs:%s", sysfs_subvendor_id)
                self.log.info("Subvendor ID from vpd :%s", vpd_subvendor_id)
                if sysfs_subvendor_id == vpd_subvendor_id:
                    self.log.info("======>>>Subvendor ID Match Success\n\n")
                else:
                    self.log.error("---->>Subvendor_id Not Matched\n\n")
                    error.append(pci_adres + "->Subvendor_id")
                '''
                PCI ID Match
                '''
                lspci_pci_id = pci.get_pci_id(pci_adres)
                self.log.info(" PCI ID from Sysfs:%s", sys_pci_id_output)
                self.log.info("PCI ID from Vpd :%s", lspci_pci_id)

                if sys_pci_id_output == lspci_pci_id:
                    self.log.info("======>>>> All PCI ID match Success\n\n")
                else:
                    self.log.error("---->>>PCI info Did not Matches\n\n")
                    error.append(pci_adres + "->pci_id")

        if error:
            self.log.error("failed pci addresses:%s", error)
            self.fail("Data mismatched for above pci addresses:")
예제 #2
0
    def test(self):
        '''
        Test
        '''
        error = []
        for pci_addr in pci.get_pci_addresses():
            self.log.info("Checking for PCI Address: %s\n\n", pci_addr)
            vpd_output = pci.get_vpd(pci_addr)
            if vpd_output:

                # Slot Match
                if 'slot' in vpd_output:
                    sys_slot = pci.get_slot_from_sysfs(pci_addr)
                    if sys_slot:
                        sys_slot = sys_slot.strip('\0')
                    vpd_slot = vpd_output['slot']
                    self.log.info("Slot from sysfs: %s", sys_slot)
                    self.log.info("Slot from lsvpd: %s", vpd_slot)
                    if sys_slot in [sys_slot, vpd_slot[:vpd_slot.rfind('-')]]:
                        self.log.info("=======>>> slot matches perfectly\n\n")
                    else:
                        error.append(pci_addr + "-> slot")
                        self.log.info("--->>Slot Numbers not Matched\n\n")
                else:
                    self.log.error("Slot info not available in vpd output\n")

                # Device ID match
                sys_pci_id_output = pci.get_pci_id_from_sysfs(pci_addr)
                vpd_device_id = vpd_output['pci_id'][4:]
                sysfs_device_id = sys_pci_id_output[5:-10]
                self.log.info("Device ID from sysfs: %s", sysfs_device_id)
                self.log.info("Device ID from vpd: %s", vpd_device_id)
                if vpd_device_id == sysfs_device_id:
                    self.log.info("=======>>Device ID Match Success\n\n")
                else:
                    self.log.error("----->>Device ID did not Match\n\n")
                    error.append(pci_addr + "-> Device_id")

                # Subvendor ID Match
                sysfs_subvendor_id = sys_pci_id_output[10:-5]
                vpd_subvendor_id = vpd_output['pci_id'][:4]
                self.log.info("Subvendor ID frm sysfs: %s", sysfs_subvendor_id)
                self.log.info("Subvendor ID from vpd : %s", vpd_subvendor_id)
                if sysfs_subvendor_id == vpd_subvendor_id:
                    self.log.info("======>>>Subvendor ID Match Success\n\n")
                else:
                    self.log.error("---->>Subvendor_id Not Matched\n\n")
                    error.append(pci_addr + "-> Subvendor_id")

                # PCI ID Match
                lspci_pci_id = pci.get_pci_id(pci_addr)
                self.log.info(" PCI ID from Sysfs: %s", sys_pci_id_output)
                self.log.info("PCI ID from Vpd : %s", lspci_pci_id)

                if sys_pci_id_output == lspci_pci_id:
                    self.log.info("======>>>> All PCI ID match Success\n\n")
                else:
                    self.log.error("---->>>PCI info Did not Matches\n\n")
                    error.append(pci_addr + "-> pci_id")

                # PCI Config Space Check
                if process.system("lspci -xxxx -s %s" % pci_addr,
                                  ignore_status=True,
                                  sudo=True):
                    error.append(pci_addr + "->pci_config_space")

        if error:
            self.fail("Errors for above pci addresses: %s" % error)
    def test(self):
        '''
        Test
        '''
        error = []
        for pci_addr in pci.get_pci_addresses():
            self.log.info("Checking for PCI Address: %s\n\n", pci_addr)
            vpd_output = pci.get_vpd(pci_addr)
            if vpd_output:

                # Slot Match
                if 'slot' in vpd_output:
                    sys_slot = pci.get_slot_from_sysfs(pci_addr)
                    if sys_slot:
                        sys_slot = sys_slot.strip('\0')
                    vpd_slot = vpd_output['slot']
                    self.log.info("Slot from sysfs: %s", sys_slot)
                    self.log.info("Slot from lsvpd: %s", vpd_slot)
                    if sys_slot in [sys_slot, vpd_slot[:vpd_slot.rfind('-')]]:
                        self.log.info("=======>>> slot matches perfectly\n\n")
                    else:
                        error.append(pci_addr + "-> slot")
                        self.log.info("--->>Slot Numbers not Matched\n\n")
                else:
                    self.log.error("Slot info not available in vpd output\n")

                # Device ID match
                sys_pci_id_output = pci.get_pci_id_from_sysfs(pci_addr)
                vpd_dev_id = vpd_output['pci_id'][4:]
                sysfs_dev_id = sys_pci_id_output[5:-10]
                sysfs_sdev_id = sys_pci_id_output[15:]
                self.log.info("Device ID from sysfs: %s", sysfs_dev_id)
                self.log.info("Sub Device ID from sysfs: %s", sysfs_sdev_id)
                self.log.info("Device ID from vpd: %s", vpd_dev_id)
                if vpd_dev_id == sysfs_sdev_id or vpd_dev_id == sysfs_dev_id:
                    self.log.info("=======>>Device ID Match Success\n\n")
                else:
                    self.log.error("----->>Device ID did not Match\n\n")
                    error.append(pci_addr + "-> Device_id")

                # Subvendor ID Match
                sysfs_subvendor_id = sys_pci_id_output[10:-5]
                vpd_subvendor_id = vpd_output['pci_id'][:4]
                self.log.info("Subvendor ID frm sysfs: %s", sysfs_subvendor_id)
                self.log.info("Subvendor ID from vpd : %s", vpd_subvendor_id)
                if sysfs_subvendor_id == vpd_subvendor_id:
                    self.log.info("======>>>Subvendor ID Match Success\n\n")
                else:
                    self.log.error("---->>Subvendor_id Not Matched\n\n")
                    error.append(pci_addr + "-> Subvendor_id")

                # PCI ID Match
                lspci_pci_id = pci.get_pci_id(pci_addr)
                self.log.info(" PCI ID from Sysfs: %s", sys_pci_id_output)
                self.log.info("PCI ID from Vpd : %s", lspci_pci_id)

                if sys_pci_id_output == lspci_pci_id:
                    self.log.info("======>>>> All PCI ID match Success\n\n")
                else:
                    self.log.error("---->>>PCI info Did not Matches\n\n")
                    error.append(pci_addr + "-> pci_id")

                # PCI Config Space Check
                if process.system("lspci -xxxx -s %s" % pci_addr,
                                  ignore_status=True, sudo=True):
                    error.append(pci_addr + "->pci_config_space")

        if error: