def _init_ppc_logging(self, table, variable, index, eval_function, eval_name): var_name = self._get_output_name(table, variable) ppc = self.net["_ppc"] if ppc is None: # if no ppc is in net-> create one options = dict(algorithm='nr', calculate_voltage_angles="auto", init="auto", max_iteration="auto", tolerance_mva=1e-8, trafo_model="t", trafo_loading="current", enforce_q_lims=False, check_connectivity=True, voltage_depend_loads=True, consider_line_temperature=False) _init_runpp_options(self.net, **options) ppc, _ = _pd2ppc(self.net) self.net["_ppc"] = ppc index = list(range(sum(ppc['bus'][:, BUS_TYPE] != NONE))) self._append_output_list(table, variable, index, eval_function, eval_name, var_name, func=self._log_ppc) return index
def runpp(self, net, max_iteration=10, need_reset=True, **kwargs): net_orig = copy.deepcopy(net) pp.runpp(net_orig) V_orig = net_orig._ppc["internal"]["V"] # ---------- pp.run.runpp() ----------------- t0_start = time() t0_options = time() passed_parameters = _passed_runpp_parameters(locals()) _init_runpp_options(net, algorithm="nr", calculate_voltage_angles="auto", init="auto", max_iteration=max_iteration, tolerance_mva=1e-8, trafo_model="t", trafo_loading="current", enforce_q_lims=False, check_connectivity=False, voltage_depend_loads=True, consider_line_temperature=False, passed_parameters=passed_parameters, numba=True, **kwargs) _check_bus_index_and_print_warning_if_high(net) _check_gen_index_and_print_warning_if_high(net) et_options = time() - t0_options # ---------- pp.powerflow._powerflow() ----------------- """ Gets called by runpp or rundcpp with different arguments. """ # get infos from options t0_early_init = time() init_results = net["_options"]["init_results"] ac = net["_options"]["ac"] algorithm = net["_options"]["algorithm"] net["converged"] = False net["OPF_converged"] = False _add_auxiliary_elements(net) if not ac or init_results: verify_results(net) else: reset_results(net, all_empty=False) # TODO remove this when zip loads are integrated for all PF algorithms if algorithm not in ['nr', 'bfsw']: net["_options"]["voltage_depend_loads"] = False _add_auxiliary_elements(net) # convert pandapower net to ppc ppc, self.ppci = _pd2ppc(net) # pdb.set_trace() # store variables net["_ppc"] = ppc if not "VERBOSE" in kwargs: kwargs["VERBOSE"] = 0 # ----- run the powerflow ----- options = net["_options"] et_early_init = time() - t0_early_init # ---------- pp.powerflow._run_pf_algorithm() ---------------- # ---------- pp.pf.run_newton_raphson_pf.run_newton_raphson_pf() ---------------- t0 = time() t0_init = t0 et_init_dc = 0. if need_reset: if isinstance(options["init_va_degree"], str) and options["init_va_degree"] == "dc": self.ppci = _run_dc_pf(self.ppci) et_init_dc = time() - t0 if options["enforce_q_lims"]: raise NotImplementedError("enforce_q_lims not yet implemented") t0_init = time() # ---------- pp.pf.run_newton_raphson_pf._run_ac_pf_without_qlims_enforced ---------- # ppci, success, iterations = _run_ac_pf_without_qlims_enforced(ppci, options) makeYbus, pfsoln = _get_numba_functions(self.ppci, options) self.baseMVA, self.bus, self.gen, self.branch, self.ref, self.pv, self.pq, _, _, V0, self.ref_gens = _get_pf_variables_from_ppci( self.ppci) self.ppci, self.Ybus, self.Yf, self.Yt = _get_Y_bus( self.ppci, options, makeYbus, self.baseMVA, self.bus, self.branch) # TODO i have a problem here for the order of the bus / id of bus tmp_bus_ind = np.argsort(net.bus.index) model = DataModel() # model.set_sn_mva(net.sn_mva) # model.set_f_hz(net.f_hz) # TODO set that elsewhere self.converter.set_sn_mva(net.sn_mva) self.converter.set_f_hz(net.f_hz) # init_but should be called first among all the rest model.init_bus(net.bus.iloc[tmp_bus_ind]["vn_kv"].values, net.line.shape[0], net.trafo.shape[0]) # init the shunts line_r, line_x, line_h = self.converter.get_line_param( net.line["r_ohm_per_km"].values * net.line["length_km"].values, net.line["x_ohm_per_km"].values * net.line["length_km"].values, net.line["c_nf_per_km"].values * net.line["length_km"].values, net.line["g_us_per_km"].values * net.line["length_km"].values, net.bus.loc[net.line["from_bus"]]["vn_kv"], net.bus.loc[net.line["to_bus"]]["vn_kv"]) model.init_powerlines(line_r, line_x, line_h, net.line["from_bus"].values, net.line["to_bus"].values) # init the shunts model.init_shunt(net.shunt["p_mw"].values, net.shunt["q_mvar"].values, net.shunt["bus"].values) # init trafo if net.trafo.shape[0]: trafo_r, trafo_x, trafo_b = self.converter.get_trafo_param( net.trafo["vn_hv_kv"].values, net.trafo["vn_lv_kv"].values, net.trafo["vk_percent"].values, net.trafo["vkr_percent"].values, net.trafo["sn_mva"].values, net.trafo["pfe_kw"].values, net.trafo["i0_percent"].values, net.bus.loc[net.trafo["lv_bus"]]["vn_kv"]) # trafo_branch = ppc["branch"][net.line.shape[0]:, :] tap_step_pct = net.trafo["tap_step_percent"].values tap_step_pct[~np.isfinite(tap_step_pct)] = 0. tap_pos = net.trafo["tap_pos"].values tap_pos[~np.isfinite(tap_pos)] = 0. is_tap_hv_side = net.trafo["tap_side"].values == "hv" is_tap_hv_side[~np.isfinite(tap_pos)] = True model.init_trafo(trafo_r, trafo_x, trafo_b, tap_step_pct, tap_pos, is_tap_hv_side, net.trafo["hv_bus"].values, net.trafo["lv_bus"].values) model.init_loads(net.load["p_mw"].values, net.load["q_mvar"].values, net.load["bus"].values) model.init_generators(net.gen["p_mw"].values, net.gen["vm_pu"].values, net.gen["bus"].values) # TODO better way here! model.add_slackbus(net.ext_grid["bus"].values) # model.init_Ybus() # Ybus = model.get_Ybus() # be careful, the order is not the same between this and pandapower, you need to change it # Ybus_proper_oder = Ybus[np.array([net.bus.index]).T, np.array([net.bus.index])] # self.Ybus_proper_oder = self.Ybus else: pass # TODO update self.ppci with new values of generation - load such that Sbus is properly udpated # compute complex bus power injections [generation - load] Sbus = _get_Sbus(self.ppci, False) # Sbus_me = model.get_Sbus() # pdb.set_trace() # Sbus_me_r = np.real(Sbus_me) # Va0 = np.full(net.bus.shape[0], fill_value=net["_options"]["init_vm_pu"], dtype=np.complex_) # Va0[net.ext_grid["bus"].values] = net.ext_grid["vm_pu"].values * np.exp(1j * net.ext_grid["va_degree"].values / 360. * 2 * np.pi) #dctheta = model.dc_pf(Sbus_me_r, Va0) # self.dctheta = V0[tmp_bus_ind] # self.dcYbus = self.ppci["internal"]['Bbus'][np.array([tmp_bus_ind]).T, np.array([tmp_bus_ind])] # tmpdc = np.abs(dcYbus - self.dcYbus) # pv_me = model.get_pv() # pq_me = model.get_pq() # pdb.set_trace() # run the newton power flow # ------------------- pp.pypower.newtonpf --------------------- max_it = options["max_iteration"] tol = options['tolerance_mva'] self.Ybus = sparse.csc_matrix(self.Ybus) et_init = time() - t0_init t0__ = time() if need_reset: # reset the solver self.solver.reset() self.V = 1.0 * copy.deepcopy(V0) else: # reuse previous voltages pass self.solver.solve(self.Ybus, self.V, Sbus, self.pv, self.pq, max_it, tol) et__ = time() - t0__ t0_ = time() Va = self.solver.get_Va() Vm = self.solver.get_Vm() self.V = Vm * np.exp(1j * Va) J = self.solver.get_J() success = self.solver.converged() iterations = self.solver.get_nb_iter() # timer_Fx_, timer_solve_, timer_initialize_, timer_check_, timer_dSbus_, timer_fillJ_, timer_total_nr_ timers = self.solver.get_timers() et_ = time() - t0_ # ---------------------- pp.pypower.newtonpf --------------------- self.ppci = _store_internal( self.ppci, { "J": J, "Vm_it": None, "Va_it": None, "bus": self.bus, "gen": self.gen, "branch": self.branch, "baseMVA": self.baseMVA, "V": self.V, "pv": self.pv, "pq": self.pq, "ref": self.ref, "Sbus": Sbus, "ref_gens": self.ref_gens, "Ybus": self.Ybus, "Yf": self.Yf, "Yt": self.Yt, "timers": timers, "time_get_res": et_, "time_solve": et__, "time_init": et_init, "time_init_dc": et_init_dc, "time_early_init": et_early_init, "time_options": et_options }) t0_ppci_to_pfsoln = time() # update data matrices with solution store in ppci # ---------- pp.pf.run_newton_raphson_pf._run_ac_pf_without_qlims_enforced ---------- self.bus, self.gen, self.branch = ppci_to_pfsoln(self.ppci, options) te_ppci_to_pfsoln = time() - t0_ppci_to_pfsoln # these are the values from pypower / matlab t0_store_res = time() et = t0_store_res - t0 result = _store_results_from_pf_in_ppci(self.ppci, self.bus, self.gen, self.branch, success, iterations, et) t0_to_net = time() et_store_res = t0_to_net - t0_store_res # ---------- pp.pf.run_newton_raphson_pf.run_newton_raphson_pf() ---------------- # ---------- pp.powerflow._run_pf_algorithm() ---------------- # read the results (=ppci with results) to net _ppci_to_net(result, net) et_to_net = time() - t0_to_net # ---------- pp.powerflow._powerflow() ---------------- # ---------- pp.run.runpp() ----------------- # added et_start = time() - t0_start self.ppci = _store_internal( self.ppci, { "time_store_res": et_store_res, "time_to_net": et_to_net, "time_all": et_start, "time_ppci_to_pfsoln": te_ppci_to_pfsoln }) has_conv = model.compute_newton(V0[tmp_bus_ind], max_it, tol) # check the results results_solver = np.max(np.abs(V_orig - self.V)) Ybus = model.get_Ybus() Ybus_proper_oder = Ybus self.Ybus_proper_oder = self.Ybus[np.array([tmp_bus_ind]).T, np.array([tmp_bus_ind])] tmp = np.abs(Ybus_proper_oder - self.Ybus_proper_oder) # > 1e-7 por, qor, vor, aor = model.get_lineor_res() pex, qex, vex, aex = model.get_lineex_res() load_p, load_q, load_v = model.get_loads_res() np.max(np.abs(por - net_orig.res_line["p_from_mw"])) np.max(np.abs(qor - net_orig.res_line["q_from_mvar"])) a_or_pp = np.sqrt(net.res_line["p_from_mw"].values**2 + net.res_line["q_from_mvar"].values**2) a_or_pp /= np.sqrt(3) * net.bus.loc[net.line["from_bus"].values][ "vn_kv"].values * net.res_line["vm_from_pu"].values np.max(np.abs(a_or_pp - aor)) np.max(np.abs(a_or_pp - net.res_line["i_from_ka"])) np.max(np.abs(a_or_pp - net.res_line["i_from_ka"])) Va_me2 = model.get_Va() Vm_me2 = model.get_Vm() res_vm = np.abs(Vm_me2 - Vm[tmp_bus_ind]) res_va = np.abs(Va_me2 - Va[tmp_bus_ind]) # check that if i start the solver on the data Sbus_me = model.get_Sbus() pv_me = model.get_pv() pq_me = model.get_pq() np.all(sorted(pv_me) == sorted(net.gen["bus"])) np.all(sorted(pq_me) == sorted(tmp_bus_ind[self.pq])) plv, qlv, vlv, alv = model.get_trafolv_res() phv, qhv, vhv, ahv = model.get_trafohv_res() res_trafo = np.abs(plv - net_orig.res_trafo["p_lv_mw"].values) res_trafo_q = np.abs(qlv - net_orig.res_trafo["q_lv_mvar"].values) # self.solver.reset() # self.solver.solve(Ybus, V0, Sbus, pv_me, pq_me, max_it, tol) # Va2 = self.solver.get_Va() # Vm2 = self.solver.get_Vm() pdb.set_trace()