예제 #1
0
def test_select_detectors():
    # Generate a PYPIT file
    pypit_file = data_path('test.pypeit')
    make_pypeit_file(pypit_file,
                     'shane_kast_blue', [data_path('b*fits.gz')],
                     setup_mode=True)

    # Perform the setup
    setup = pypeitsetup.PypeItSetup.from_pypeit_file(pypit_file)
    par, spectrograph, fitstbl = setup.run(sort_dir=data_path(''))

    assert PypeIt.select_detectors(detnum=par['rdx']['detnum'], ndet=spectrograph.ndet) == [1], \
            'Incorrect detectors selected.'

    # Clean-up
    os.remove(data_path('test.calib'))
    os.remove(data_path('test.pypeit'))

    assert np.array_equal(PypeIt.select_detectors(),
                          [1]), 'Incorrect detectors selected.'
    assert np.array_equal(PypeIt.select_detectors(detnum=3, ndet=5), [3]), \
            'Incorrect detectors selected.'
    assert np.array_equal(PypeIt.select_detectors(ndet=5), [1,2,3,4,5]), \
            'Incorrect detectors selected.'
    assert np.array_equal(PypeIt.select_detectors(detnum=[1,3]), [1,3]), \
            'Incorrect detectors selected.'
예제 #2
0
def main(args):
    """ Executes 2d coadding
    """

    # Load the file
    if args.file is not None:
        spectrograph, config_lines, spec2d_files = read_coadd2d_file(args.file)
        # Parameters
        # TODO: Shouldn't this reinstantiate the same parameters used in
        # the PypeIt run that extracted the objects?  Why are we not
        # just passing the pypeit file?
        spectrograph_def_par = spectrograph.default_pypeit_par()
        par = par.PypeItPar.from_cfg_lines(
            cfg_lines=spectrograph_def_par.to_config(),
            merge_with=config_lines)
    elif args.obj is not None:
        # TODO: This needs to define the science path
        spec2d_files = glob.glob('./Science/spec2d_*' + args.obj + '*')
        head0 = fits.getheader(spec2d_files[0])
        spectrograph_name = head0['SPECTROG']
        spectrograph = load_spectrograph(spectrograph_name)
        par = spectrograph.default_pypeit_par()
    else:
        msgs.error(
            'You must either input a coadd2d file with --file or an object name with --obj'
        )

    # If detector was passed as an argument override whatever was in the coadd2d_file
    if args.det is not None:
        msgs.info("Restricting reductions to detector={}".format(args.det))
        par['rdx']['detnum'] = int(args.det)

    # Get headers and base names
    spec1d_files = [
        files.replace('spec2d', 'spec1d') for files in spec2d_files
    ]
    head1d = fits.getheader(spec1d_files[0])
    head2d = fits.getheader(spec2d_files[0])
    if args.basename is None:
        filename = os.path.basename(spec2d_files[0])
        basename = filename.split('_')[1]
    else:
        basename = args.basename

    # Write the par to disk
    par_outfile = basename + '_coadd2d.par'
    print("Writing the parameters to {}".format(par_outfile))
    par.to_config(par_outfile)

    # Now run the coadds

    skysub_mode = head2d['SKYSUB']
    ir_redux = True if 'DIFF' in skysub_mode else False

    # Print status message
    msgs_string = 'Reducing target {:s}'.format(basename) + msgs.newline()
    msgs_string += 'Performing coadd of frames reduce with {:s} imaging'.format(
        skysub_mode)
    msgs_string += msgs.newline(
    ) + 'Combining frames in 2d coadd:' + msgs.newline()
    for file in spec2d_files:
        msgs_string += '{0:s}'.format(os.path.basename(file)) + msgs.newline()
    msgs.info(msgs_string)

    # TODO: This needs to be added to the parameter list for rdx
    redux_path = os.getcwd()
    master_dirname = os.path.basename(head2d['PYPMFDIR']) + '_coadd'
    master_dir = os.path.join(redux_path, master_dirname)

    # Make the new Master dir
    if not os.path.isdir(master_dir):
        msgs.info(
            'Creating directory for Master output: {0}'.format(master_dir))
        os.makedirs(master_dir)

    # Instantiate the sci_dict
    sci_dict = OrderedDict()  # This needs to be ordered
    sci_dict['meta'] = {}
    sci_dict['meta']['vel_corr'] = 0.
    sci_dict['meta']['ir_redux'] = ir_redux

    # Find the detectors to reduce
    detectors = PypeIt.select_detectors(detnum=par['rdx']['detnum'],
                                        ndet=spectrograph.ndet)
    if len(detectors) != spectrograph.ndet:
        msgs.warn('Not reducing detectors: {0}'.format(' '.join([
            str(d) for d in set(np.arange(spectrograph.ndet)) - set(detectors)
        ])))

    # Loop on detectors
    for det in detectors:
        msgs.info("Working on detector {0}".format(det))
        sci_dict[det] = {}

        # Read in the images stacks and other clibration/meta data for this detector
        stack_dict = coadd2d.load_coadd2d_stacks(spec2d_files, det)

        sci_dict[det]['sciimg'], sci_dict[det]['sciivar'], sci_dict[det]['skymodel'], \
                sci_dict[det]['objmodel'], sci_dict[det]['ivarmodel'], sci_dict[det]['outmask'], \
                sci_dict[det]['specobjs'] \
                        = coadd2d.extract_coadd2d(stack_dict, master_dir, det, ir_redux=ir_redux,
                                                  par=par, show=args.show, show_peaks=args.peaks,
                                                  std=args.std, samp_fact=args.samp_fact)

    # Make the new Science dir
    # TODO: This needs to be defined by the user
    scipath = os.path.join(redux_path, 'Science_coadd')
    if not os.path.isdir(scipath):
        msgs.info('Creating directory for Science output: {0}'.format(scipath))
        os.makedirs(scipath)

    # Save the results
    save.save_all(sci_dict, stack_dict['master_key_dict'], master_dir,
                  spectrograph, head1d, head2d, scipath, basename)
예제 #3
0
def main(args):
    """ Executes 2d coadding
    """
    msgs.warn('PATH =' + os.getcwd())
    # Load the file
    if args.file is not None:
        spectrograph, config_lines, spec2d_files = read_coadd2d_file(args.file)
        # Parameters
        # TODO: Shouldn't this reinstantiate the same parameters used in
        # the PypeIt run that extracted the objects?  Why are we not
        # just passing the pypeit file?
        # JFH: The reason is that the coadd2dfile may want different reduction parameters
        spectrograph_def_par = spectrograph.default_pypeit_par()
        parset = par.PypeItPar.from_cfg_lines(cfg_lines=spectrograph_def_par.to_config(),
                                                 merge_with=config_lines)
    elif args.obj is not None:
        # TODO: We should probably be reading the pypeit file and using those parameters here rather than using the
        # default parset.
        # TODO: This needs to define the science path
        spec2d_files = glob.glob('./Science/spec2d_*' + args.obj + '*')
        head0 = fits.getheader(spec2d_files[0])
        spectrograph_name = head0['SPECTROG']
        spectrograph = load_spectrograph(spectrograph_name)
        parset = spectrograph.default_pypeit_par()
    else:
        msgs.error('You must either input a coadd2d file with --file or an object name with --obj')

    # Update with configuration specific parameters (which requires science file) and initialize spectrograph
    spectrograph_cfg_lines = spectrograph.config_specific_par(spec2d_files[0]).to_config()
    parset = par.PypeItPar.from_cfg_lines(cfg_lines=spectrograph_cfg_lines, merge_with=parset.to_config())

    # If detector was passed as an argument override whatever was in the coadd2d_file
    if args.det is not None:
        msgs.info("Restricting reductions to detector={}".format(args.det))
        parset['rdx']['detnum'] = int(args.det)

    # Get headers (if possible) and base names
    spec1d_files = [files.replace('spec2d', 'spec1d') for files in spec2d_files]
    head1d = None
    for spec1d_file in spec1d_files:
        if os.path.isfile(spec1d_file):
            head1d = fits.getheader(spec1d_file)
            break
    if head1d is None:
        msgs.warn("No 1D spectra so am generating a dummy header for output")
        head1d = io.initialize_header()

    head2d = fits.getheader(spec2d_files[0])
    if args.basename is None:
        filename = os.path.basename(spec2d_files[0])
        basename = filename.split('_')[2]
    else:
        basename = args.basename

    # Write the par to disk
    par_outfile = basename+'_coadd2d.par'
    print("Writing the parameters to {}".format(par_outfile))
    parset.to_config(par_outfile)

    # Now run the coadds

    skysub_mode = head2d['SKYSUB']
    ir_redux = True if 'DIFF' in skysub_mode else False

    # Print status message
    msgs_string = 'Reducing target {:s}'.format(basename) + msgs.newline()
    msgs_string += 'Performing coadd of frames reduce with {:s} imaging'.format(skysub_mode)
    msgs_string += msgs.newline() + 'Combining frames in 2d coadd:' + msgs.newline()
    for file in spec2d_files:
        msgs_string += '{0:s}'.format(os.path.basename(file)) + msgs.newline()
    msgs.info(msgs_string)

    # TODO: This needs to be added to the parameter list for rdx
    redux_path = os.getcwd()
    master_dirname = os.path.basename(head2d['PYPMFDIR']) + '_coadd'
    master_dir = os.path.join(redux_path, master_dirname)

    # Make the new Master dir
    if not os.path.isdir(master_dir):
        msgs.info('Creating directory for Master output: {0}'.format(master_dir))
        os.makedirs(master_dir)

    # Instantiate the sci_dict
    sci_dict = OrderedDict()  # This needs to be ordered
    sci_dict['meta'] = {}
    sci_dict['meta']['vel_corr'] = 0.
    sci_dict['meta']['ir_redux'] = ir_redux

    # Find the detectors to reduce
    detectors = PypeIt.select_detectors(detnum=parset['rdx']['detnum'], ndet=spectrograph.ndet)
    if len(detectors) != spectrograph.ndet:
        msgs.warn('Not reducing detectors: {0}'.format(' '.join([str(d) for d in
        set(np.arange(spectrograph.ndet) + 1) - set(detectors)])))

    # Loop on detectors
    for det in detectors:
        msgs.info("Working on detector {0}".format(det))
        sci_dict[det] = {}

        # Instantiate Coadd2d
        coadd = coadd2d.CoAdd2D.get_instance(spec2d_files, spectrograph, parset, det=det,
                                             offsets=parset['coadd2d']['offsets'],
                                             weights=parset['coadd2d']['weights'],
                                             ir_redux=ir_redux,
                                             debug_offsets=args.debug_offsets, debug=args.debug,
                                             samp_fact=args.samp_fact)

        # Coadd the slits
        coadd_dict_list = coadd.coadd(only_slits=None) # TODO implement only_slits later
        # Create the psuedo images
        psuedo_dict = coadd.create_psuedo_image(coadd_dict_list)
        # Reduce
        msgs.info('Running the extraction')
        sci_dict[det]['sciimg'], sci_dict[det]['sciivar'], sci_dict[det]['skymodel'], sci_dict[det]['objmodel'], \
        sci_dict[det]['ivarmodel'], sci_dict[det]['outmask'], sci_dict[det]['specobjs'] = coadd.reduce(
            psuedo_dict, show = args.show, show_peaks = args.peaks)
        # Save psuedo image master files
        coadd.save_masters(master_dir)

    # Make the new Science dir
    # TODO: This needs to be defined by the user
    scipath = os.path.join(redux_path, 'Science_coadd')
    if not os.path.isdir(scipath):
        msgs.info('Creating directory for Science output: {0}'.format(scipath))
        os.makedirs(scipath)

    # Save the results
    save.save_all(sci_dict, coadd.stack_dict['master_key_dict'], master_dir, spectrograph, head1d,
                  head2d, scipath, basename)#, binning=coadd.binning)
예제 #4
0
def main(args):
    """ Executes 2d coadding
    """
    msgs.warn('PATH =' + os.getcwd())
    # Load the file
    if args.file is not None:
        spectrograph_name, config_lines, spec2d_files = io.read_spec2d_file(
            args.file, filetype="coadd2d")
        spectrograph = load_spectrograph(spectrograph_name)

        # Parameters
        # TODO: Shouldn't this reinstantiate the same parameters used in
        # the PypeIt run that extracted the objects?  Why are we not
        # just passing the pypeit file?
        # JFH: The reason is that the coadd2dfile may want different reduction parameters
        spectrograph_def_par = spectrograph.default_pypeit_par()
        parset = par.PypeItPar.from_cfg_lines(
            cfg_lines=spectrograph_def_par.to_config(),
            merge_with=config_lines)
    elif args.obj is not None:
        # TODO: We should probably be reading the pypeit file and using those parameters here rather than using the
        # default parset.
        # TODO: This needs to define the science path
        spec2d_files = glob.glob('./Science/spec2d_*' + args.obj + '*')
        head0 = fits.getheader(spec2d_files[0])
        spectrograph_name = head0['PYP_SPEC']
        spectrograph = load_spectrograph(spectrograph_name)
        parset = spectrograph.default_pypeit_par()
    else:
        msgs.error(
            'You must either input a coadd2d file with --file or an object name with --obj'
        )

    # Update with configuration specific parameters (which requires science file) and initialize spectrograph
    spectrograph_cfg_lines = spectrograph.config_specific_par(
        spec2d_files[0]).to_config()
    parset = par.PypeItPar.from_cfg_lines(cfg_lines=spectrograph_cfg_lines,
                                          merge_with=parset.to_config())

    # If detector was passed as an argument override whatever was in the coadd2d_file
    if args.det is not None:
        msgs.info("Restricting reductions to detector={}".format(args.det))
        parset['rdx']['detnum'] = int(args.det)

    # Get headers (if possible) and base names
    spec1d_files = [
        files.replace('spec2d', 'spec1d') for files in spec2d_files
    ]
    head1d = None
    for spec1d_file in spec1d_files:
        if os.path.isfile(spec1d_file):
            head1d = fits.getheader(spec1d_file)
            break
    if head1d is None:
        msgs.warn("No 1D spectra so am generating a dummy header for output")
        head1d = io.initialize_header()

    head2d = fits.getheader(spec2d_files[0])
    if args.basename is None:
        filename = os.path.basename(spec2d_files[0])
        basename = filename.split('_')[2]
    else:
        basename = args.basename

    # Write the par to disk
    par_outfile = basename + '_coadd2d.par'
    print("Writing the parameters to {}".format(par_outfile))
    parset.to_config(par_outfile)

    # Now run the coadds

    skysub_mode = head2d['SKYSUB']
    ir_redux = True if 'DIFF' in skysub_mode else False

    # Print status message
    msgs_string = 'Reducing target {:s}'.format(basename) + msgs.newline()
    msgs_string += 'Performing coadd of frames reduce with {:s} imaging'.format(
        skysub_mode)
    msgs_string += msgs.newline(
    ) + 'Combining frames in 2d coadd:' + msgs.newline()
    for file in spec2d_files:
        msgs_string += '{0:s}'.format(os.path.basename(file)) + msgs.newline()
    msgs.info(msgs_string)

    # TODO: This needs to be added to the parameter list for rdx
    redux_path = os.getcwd()
    master_dirname = os.path.basename(head2d['PYPMFDIR']) + '_coadd'
    master_dir = os.path.join(redux_path, master_dirname)

    # Make the new Master dir
    if not os.path.isdir(master_dir):
        msgs.info(
            'Creating directory for Master output: {0}'.format(master_dir))
        os.makedirs(master_dir)

    # Instantiate the sci_dict
    sci_dict = OrderedDict()  # This needs to be ordered
    sci_dict['meta'] = {}
    sci_dict['meta']['vel_corr'] = 0.
    sci_dict['meta']['ir_redux'] = ir_redux

    # Find the detectors to reduce
    detectors = PypeIt.select_detectors(detnum=parset['rdx']['detnum'],
                                        ndet=spectrograph.ndet)
    if len(detectors) != spectrograph.ndet:
        msgs.warn('Not reducing detectors: {0}'.format(' '.join([
            str(d)
            for d in set(np.arange(spectrograph.ndet) + 1) - set(detectors)
        ])))

    # Loop on detectors
    for det in detectors:
        msgs.info("Working on detector {0}".format(det))
        sci_dict[det] = {}

        # Instantiate Coadd2d
        coadd = coadd2d.CoAdd2D.get_instance(
            spec2d_files,
            spectrograph,
            parset,
            det=det,
            offsets=parset['coadd2d']['offsets'],
            weights=parset['coadd2d']['weights'],
            ir_redux=ir_redux,
            debug_offsets=args.debug_offsets,
            debug=args.debug,
            samp_fact=args.samp_fact)

        # Coadd the slits
        coadd_dict_list = coadd.coadd(
            only_slits=None)  # TODO implement only_slits later
        # Create the pseudo images
        pseudo_dict = coadd.create_pseudo_image(coadd_dict_list)
        # Reduce
        msgs.info('Running the extraction')
        # TODO -- This should mirror what is in pypeit.extract_one
        # TODO -- JFH :: This ought to return a Spec2DObj and SpecObjs which would be slurped into
        #  AllSpec2DObj and all_specobsj, as below.
        # TODO -- JFH -- Check that the slits we are using are correct
        sci_dict[det]['sciimg'], sci_dict[det]['sciivar'], sci_dict[det]['skymodel'], sci_dict[det]['objmodel'], \
        sci_dict[det]['ivarmodel'], sci_dict[det]['outmask'], sci_dict[det]['specobjs'], sci_dict[det]['detector'], \
            sci_dict[det]['slits'], sci_dict[det]['tilts'], sci_dict[det]['waveimg'] = coadd.reduce(
            pseudo_dict, show = args.show, show_peaks = args.peaks)

        # Save pseudo image master files
        #coadd.save_masters()

    # Make the new Science dir
    # TODO: This needs to be defined by the user
    scipath = os.path.join(redux_path, 'Science_coadd')
    if not os.path.isdir(scipath):
        msgs.info('Creating directory for Science output: {0}'.format(scipath))
        os.makedirs(scipath)

    # THE FOLLOWING MIMICS THE CODE IN pypeit.save_exposure()

    # TODO -- These lines should be above once reduce() passes back something sensible
    all_specobjs = specobjs.SpecObjs()
    for det in detectors:
        all_specobjs.add_sobj(sci_dict[det]['specobjs'])

    # Write
    outfile1d = os.path.join(scipath, 'spec1d_{:s}.fits'.format(basename))
    subheader = spectrograph.subheader_for_spec(head2d, head2d)
    all_specobjs.write_to_fits(subheader, outfile1d)

    # 2D spectra
    # TODO -- These lines should be above once reduce() passes back something sensible
    all_spec2d = spec2dobj.AllSpec2DObj()
    all_spec2d['meta']['ir_redux'] = ir_redux
    for det in detectors:
        all_spec2d[det] = spec2dobj.Spec2DObj(
            det=det,
            sciimg=sci_dict[det]['sciimg'],
            ivarraw=sci_dict[det]['sciivar'],
            skymodel=sci_dict[det]['skymodel'],
            objmodel=sci_dict[det]['objmodel'],
            ivarmodel=sci_dict[det]['ivarmodel'],
            scaleimg=np.array([1.0], dtype=np.float),
            bpmmask=sci_dict[det]['outmask'],
            detector=sci_dict[det]['detector'],
            slits=sci_dict[det]['slits'],
            waveimg=sci_dict[det]['waveimg'],
            tilts=sci_dict[det]['tilts'],
            sci_spat_flexure=None,
            sci_spec_flexure=None,
            vel_corr=None,
            vel_type=None)
    # Build header
    outfile2d = os.path.join(scipath, 'spec2d_{:s}.fits'.format(basename))
    pri_hdr = all_spec2d.build_primary_hdr(
        head2d,
        spectrograph,
        subheader=subheader,
        # TODO -- JFH :: Decide if we need any of these
        redux_path=None,
        master_key_dict=None,
        master_dir=None)
    # Write
    all_spec2d.write_to_fits(outfile2d, pri_hdr=pri_hdr)