Exemplo n.º 1
0
def test_utci_collection_comfort_percent_outputs():
    """Test the is_comfortable and percent outputs of the UTCI collection."""
    relative_path = './tests/epw/chicago.epw'
    epw = EPW(relative_path)
    utci_obj = UTCI(epw.dry_bulb_temperature,
                    epw.relative_humidity,
                    wind_speed=epw.wind_speed)

    assert utci_obj.percent_comfortable == pytest.approx(35.6849315, rel=1e-3)
    assert utci_obj.percent_uncomfortable == pytest.approx(64.31506849,
                                                           rel=1e-3)
    assert utci_obj.percent_neutral == pytest.approx(35.6849315, rel=1e-3)
    assert utci_obj.percent_hot == pytest.approx(3.3447488, rel=1e-3)
    assert utci_obj.percent_cold == pytest.approx(60.970319, rel=1e-3)

    assert utci_obj.percent_extreme_cold_stress == pytest.approx(0.35388127,
                                                                 rel=1e-3)
    assert utci_obj.percent_very_strong_cold_stress == pytest.approx(
        4.37214611, rel=1e-3)
    assert utci_obj.percent_strong_cold_stress == pytest.approx(16.541095,
                                                                rel=1e-3)
    assert utci_obj.percent_moderate_cold_stress == pytest.approx(23.8356164,
                                                                  rel=1e-3)
    assert utci_obj.percent_slight_cold_stress == pytest.approx(15.8675799,
                                                                rel=1e-3)

    assert utci_obj.percent_slight_heat_stress == pytest.approx(1.826484,
                                                                rel=1e-3)
    assert utci_obj.percent_moderate_heat_stress == pytest.approx(1.312785,
                                                                  rel=1e-3)
    assert utci_obj.percent_strong_heat_stress == pytest.approx(0.2054794,
                                                                rel=1e-3)
    assert utci_obj.percent_very_strong_heat_stress == 0.0
    assert utci_obj.percent_extreme_heat_stress == 0.0
Exemplo n.º 2
0
def test_get_universal_thermal_climate_index_with_sun_and_wind():
    """Test the get_universal_thermal_climate_index method with wind and sun."""
    utci_obj = UTCI.from_epw(epw, True, True)

    assert utci_obj.percent_neutral == pytest.approx(31.4269406, rel=1e-3)
    assert utci_obj.percent_hot == pytest.approx(11.4611872, rel=1e-3)
    assert utci_obj.percent_cold == pytest.approx(57.111872, rel=1e-3)
Exemplo n.º 3
0
def test_utci_collection_defaults():
    """Test the default inputs assigned to the UTCI collection."""
    calc_length = 24
    air_temp_header = Header(Temperature(), 'C',
                             AnalysisPeriod(end_month=1, end_day=1))
    air_temp = HourlyContinuousCollection(air_temp_header, [24] * calc_length)
    utci_obj = UTCI(air_temp, 50)

    assert isinstance(utci_obj.rad_temperature, HourlyContinuousCollection)
    assert len(utci_obj.rad_temperature.values) == calc_length
    assert utci_obj.rad_temperature[0] == utci_obj.air_temperature[0]

    assert isinstance(utci_obj.wind_speed, HourlyContinuousCollection)
    assert len(utci_obj.wind_speed.values) == calc_length
    assert utci_obj.wind_speed[0] == 0.1

    assert isinstance(utci_obj.comfort_parameter, UTCIParameter)
    default_par = UTCIParameter()
    assert utci_obj.comfort_parameter.cold_thresh == default_par.cold_thresh
    assert utci_obj.comfort_parameter.heat_thresh == default_par.heat_thresh
    assert utci_obj.comfort_parameter.extreme_cold_thresh == default_par.extreme_cold_thresh
    assert utci_obj.comfort_parameter.very_strong_cold_thresh == default_par.very_strong_cold_thresh
    assert utci_obj.comfort_parameter.strong_cold_thresh == default_par.strong_cold_thresh
    assert utci_obj.comfort_parameter.moderate_cold_thresh == default_par.moderate_cold_thresh
    assert utci_obj.comfort_parameter.moderate_heat_thresh == default_par.moderate_heat_thresh
    assert utci_obj.comfort_parameter.strong_heat_thresh == default_par.strong_heat_thresh
    assert utci_obj.comfort_parameter.very_strong_heat_thresh == default_par.very_strong_heat_thresh
    assert utci_obj.comfort_parameter.extreme_heat_thresh == default_par.extreme_heat_thresh
Exemplo n.º 4
0
def test_get_universal_thermal_climate_index_with_sun():
    """Test the get_universal_thermal_climate_index method with sun."""
    utci_obj = UTCI.from_epw(epw, False, True)

    assert utci_obj.percent_neutral == pytest.approx(40.730593, rel=1e-3)
    assert utci_obj.percent_hot == pytest.approx(20.4223744, rel=1e-3)
    assert utci_obj.percent_cold == pytest.approx(38.8470319, rel=1e-3)
Exemplo n.º 5
0
def test_get_universal_thermal_climate_index_with_wind():
    """Test the get_universal_thermal_climate_index method with wind."""
    utci_obj = UTCI.from_epw(epw, True, False)

    assert utci_obj.percent_neutral == pytest.approx(35.6849315, rel=1e-3)
    assert utci_obj.percent_hot == pytest.approx(3.3447488, rel=1e-3)
    assert utci_obj.percent_cold == pytest.approx(60.970319, rel=1e-3)
Exemplo n.º 6
0
def test_get_universal_thermal_climate_index():
    """Test the get_universal_thermal_climate_index method."""
    calc_length = 8760
    utci_obj = UTCI.from_epw(epw, False, False)

    assert isinstance(utci_obj, UTCI)
    assert isinstance(utci_obj.air_temperature, HourlyContinuousCollection)
    assert len(utci_obj.air_temperature.values) == calc_length
    assert utci_obj.air_temperature[0] == -6.1
    assert isinstance(utci_obj.rel_humidity, HourlyContinuousCollection)
    assert len(utci_obj.rel_humidity.values) == calc_length
    assert utci_obj.rel_humidity[0] == 81

    assert isinstance(utci_obj.universal_thermal_climate_index,
                      HourlyContinuousCollection)
    assert len(utci_obj.universal_thermal_climate_index.values) == calc_length
    assert utci_obj.universal_thermal_climate_index[0] == pytest.approx(
        -5.367017, rel=1e-3)
    assert isinstance(utci_obj.thermal_condition_eleven_point,
                      HourlyContinuousCollection)
    assert len(utci_obj.thermal_condition_eleven_point.values) == calc_length
    assert utci_obj.thermal_condition_eleven_point[0] == -2

    assert utci_obj.percent_neutral == pytest.approx(47.488584, rel=1e-3)
    assert utci_obj.percent_hot == pytest.approx(9.38356164, rel=1e-3)
    assert utci_obj.percent_cold == pytest.approx(43.1278538, rel=1e-3)
Exemplo n.º 7
0
def utci(result_sql, enclosure_info, epw_file, total_irradiance,
         direct_irradiance, ref_irradiance, sun_up_hours, wind_speed,
         run_period, comfort_par, solarcal_par, folder, log_file):
    """Get CSV files with maps of UTCI comfort from EnergyPlus and Radiance results.

    \b
    Args:
        result_sql: Path to an SQLite file that was generated by EnergyPlus.
            This file must contain hourly or sub-hourly results for zone comfort
            variables.
        enclosure_info: Path to a JSON file containing information about the radiant
            enclosure that sensor points belong to.
        epw_file: Path to an .epw file, used to estimate conditions for any outdoor
            sensors and to provide sun positions.
    """
    try:
        # load the EPW object, run period, air speed, and other parameters
        epw_obj = EPW(epw_file)
        run_period = _load_analysis_period_str(run_period)
        wind_speed = _load_values(wind_speed)
        solarcal_par = _load_solarcal_par_str(solarcal_par)
        comfort_par = _load_utci_par_str(comfort_par)

        # load and align the thermal results from the result_sql file
        pt_air_temps, pt_rad_temps, pt_humids, pt_speeds, _ = _parse_enclosure_info(
            enclosure_info,
            result_sql,
            epw_obj,
            run_period,
            wind_speed,
            include_humidity=True,
            use_10m_wind_speed=True)

        # adjust the radiant temperature for shortwave solar
        pt_rad_temps = shortwave_mrt_map(epw_obj.location, pt_rad_temps,
                                         sun_up_hours, total_irradiance,
                                         direct_irradiance, ref_irradiance,
                                         solarcal_par)

        # run the collections through the UTCI model and output results
        temperature, condition, condition_intensity = [], [], []
        for t_a, rh, t_r, vel in zip(pt_air_temps, pt_humids, pt_rad_temps,
                                     pt_speeds):
            utci_obj = UTCI(t_a, rh, t_r, vel, comfort_parameter=comfort_par)
            temperature.append(utci_obj.universal_thermal_climate_index)
            condition.append(utci_obj.thermal_condition)
            condition_intensity.append(utci_obj.thermal_condition_eleven_point)

        # write out the final results to CSV files
        result_file_dict = _thermal_map_csv(folder, result_sql, temperature,
                                            condition, condition_intensity)
        log_file.write(json.dumps(result_file_dict))
    except Exception as e:
        _logger.exception(
            'Failed to run Adaptive model comfort map.\n{}'.format(e))
        sys.exit(1)
    else:
        sys.exit(0)
Exemplo n.º 8
0
def test_utci_collection_immutability():
    """Test that the UTCI collection is immutable."""
    calc_length = 24
    air_temp_header = Header(Temperature(), 'C',
                             AnalysisPeriod(end_month=1, end_day=1))
    air_temp = HourlyContinuousCollection(air_temp_header, [24] * calc_length)
    utci_obj = UTCI(air_temp, 50)

    # check that editing the original collection does not mutate the object
    air_temp[0] = 26
    assert utci_obj.air_temperature[0] == 24

    # check that editing collection properties does not mutate the object
    with pytest.raises(Exception):
        utci_obj.air_temperature[0] = 26
    with pytest.raises(Exception):
        utci_obj.air_temperature.values = [26] * calc_length
    with pytest.raises(Exception):
        utci_obj.air_temperature = air_temp
    with pytest.raises(Exception):
        utci_obj.universal_thermal_climate_index[0] = 20
    with pytest.raises(Exception):
        utci_obj.universal_thermal_climate_index.values = [20] * calc_length

    # check that properties cannot be edited directly
    with pytest.raises(Exception):
        utci_obj.universal_thermal_climate_index = air_temp
    with pytest.raises(Exception):
        utci_obj.comfort_parameter = UTCIParameter()
Exemplo n.º 9
0
def test_utci_collection_comfort_outputs():
    """Test the is_comfortable and thermal_condition outputs of the UTCI collection."""
    calc_length = 24
    air_temp_header = Header(Temperature(), 'C',
                             AnalysisPeriod(end_month=1, end_day=1))
    air_temp = HourlyContinuousCollection(air_temp_header,
                                          range(5, 5 + calc_length))
    utci_obj = UTCI(air_temp, 50)

    assert isinstance(utci_obj.is_comfortable, HourlyContinuousCollection)
    assert len(utci_obj.is_comfortable.values) == calc_length
    assert utci_obj.is_comfortable[0] == 0
    assert utci_obj.is_comfortable[12] == 1
    assert utci_obj.is_comfortable[23] == 0

    assert isinstance(utci_obj.thermal_condition, HourlyContinuousCollection)
    assert len(utci_obj.thermal_condition.values) == calc_length
    assert utci_obj.thermal_condition[0] == -1
    assert utci_obj.thermal_condition[12] == 0
    assert utci_obj.thermal_condition[23] == 1

    assert isinstance(utci_obj.thermal_condition_five_point,
                      HourlyContinuousCollection)
    assert len(utci_obj.thermal_condition_five_point.values) == calc_length
    assert utci_obj.thermal_condition_five_point[0] == -1
    assert utci_obj.thermal_condition_five_point[12] == 0
    assert utci_obj.thermal_condition_five_point[23] == 1

    assert isinstance(utci_obj.thermal_condition_seven_point,
                      HourlyContinuousCollection)
    assert len(utci_obj.thermal_condition_seven_point.values) == calc_length
    assert utci_obj.thermal_condition_seven_point[0] == -1
    assert utci_obj.thermal_condition_seven_point[12] == 0
    assert utci_obj.thermal_condition_seven_point[23] == 1

    assert isinstance(utci_obj.thermal_condition_nine_point,
                      HourlyContinuousCollection)
    assert len(utci_obj.thermal_condition_nine_point.values) == calc_length
    assert utci_obj.thermal_condition_nine_point[0] == -1
    assert utci_obj.thermal_condition_nine_point[12] == 0
    assert utci_obj.thermal_condition_nine_point[22] == 1
    assert utci_obj.thermal_condition_nine_point[23] == 2

    assert isinstance(utci_obj.thermal_condition_eleven_point,
                      HourlyContinuousCollection)
    assert len(utci_obj.thermal_condition_eleven_point.values) == calc_length
    assert utci_obj.thermal_condition_eleven_point[0] == -1
    assert utci_obj.thermal_condition_eleven_point[12] == 0
    assert utci_obj.thermal_condition_eleven_point[22] == 1
    assert utci_obj.thermal_condition_eleven_point[23] == 2

    assert isinstance(utci_obj.original_utci_category,
                      HourlyContinuousCollection)
    assert len(utci_obj.original_utci_category.values) == calc_length
    assert utci_obj.original_utci_category[0] == 4
    assert utci_obj.original_utci_category[12] == 5
    assert utci_obj.original_utci_category[23] == 6
Exemplo n.º 10
0
def test_init_utci_collection_epw():
    """Test the initialization of the UTCI collection with EPW input."""
    calc_length = 8760
    relative_path = './tests/epw/chicago.epw'
    epw = EPW(relative_path)
    utci_obj = UTCI(epw.dry_bulb_temperature, epw.relative_humidity)

    assert len(utci_obj.air_temperature.values) == calc_length
    assert utci_obj.air_temperature[0] == -6.1
    assert len(utci_obj.rel_humidity.values) == calc_length
    assert utci_obj.rel_humidity[0] == 81

    assert len(utci_obj.universal_thermal_climate_index.values) == calc_length
    assert utci_obj.universal_thermal_climate_index[0] == pytest.approx(-5.367017, rel=1e-3)
    assert len(utci_obj.thermal_condition_eleven_point.values) == calc_length
    assert utci_obj.thermal_condition_eleven_point[0] == -2
Exemplo n.º 11
0
def test_init_utci_collection_full_collection_input():
    """Test initialization of the UTCI collection will all inputs as collections."""
    calc_length = 24
    air_temp_header = Header(Temperature(), 'C', AnalysisPeriod(end_month=1, end_day=1))
    air_temp = HourlyContinuousCollection(air_temp_header, [24] * calc_length)
    rel_humid_header = Header(RelativeHumidity(), '%', AnalysisPeriod(end_month=1, end_day=1))
    rel_humid = HourlyContinuousCollection(rel_humid_header, [50] * calc_length)
    rad_temp_header = Header(Temperature(), 'C', AnalysisPeriod(end_month=1, end_day=1))
    rad_temp = HourlyContinuousCollection(rad_temp_header, [22] * calc_length)
    wind_speed_header = Header(AirSpeed(), 'm/s', AnalysisPeriod(end_month=1, end_day=1))
    wind_speed = HourlyContinuousCollection(wind_speed_header, [0.5] * calc_length)

    utci_obj = UTCI(air_temp, rel_humid, rad_temp, wind_speed)

    assert utci_obj.air_temperature[0] == 24
    assert utci_obj.rel_humidity[0] == 50
    assert utci_obj.rad_temperature[0] == 22
    assert utci_obj.wind_speed[0] == 0.5
Exemplo n.º 12
0
def utci(epw_file, include_wind, include_sun, csv, output_file):
    """Get a data collection for UTCI from an EPW weather file.

    \b
    Args:
        epw_file: Path to an .epw file.
    """
    try:
        epw_obj = EPW(epw_file)
        utci_obj = UTCI.from_epw(epw_obj, include_wind, include_sun)
        utci_data = utci_obj.universal_thermal_climate_index
        if csv:
            output_file.write('\n'.join([str(v) for v in utci_data.values]))
        else:
            output_file.write(json.dumps(utci_data.to_dict()))
    except Exception as e:
        _logger.exception('Failed to get UTCI from EPW file.\n{}'.format(e))
        sys.exit(1)
    else:
        sys.exit(0)
Exemplo n.º 13
0
def test_init_utci_collection():
    """Test the initialization of the UTCI collection and basic outputs."""
    calc_length = 24
    air_temp_header = Header(Temperature(), 'C', AnalysisPeriod(end_month=1, end_day=1))
    air_temp = HourlyContinuousCollection(air_temp_header, [24] * calc_length)
    utci_obj = UTCI(air_temp, 50)

    assert utci_obj.comfort_model == 'Universal Thermal Climate Index'
    assert utci_obj.calc_length == calc_length
    str(utci_obj)  # test that the string representation is ok

    assert isinstance(utci_obj.air_temperature, HourlyContinuousCollection)
    assert len(utci_obj.air_temperature.values) == calc_length
    assert utci_obj.air_temperature[0] == 24
    assert isinstance(utci_obj.rel_humidity, HourlyContinuousCollection)
    assert len(utci_obj.rel_humidity.values) == calc_length
    assert utci_obj.rel_humidity[0] == 50

    assert isinstance(utci_obj.universal_thermal_climate_index, HourlyContinuousCollection)
    assert len(utci_obj.universal_thermal_climate_index.values) == calc_length
    assert utci_obj.universal_thermal_climate_index[0] == pytest.approx(23.8110341, rel=1e-3)
Exemplo n.º 14
0
def test_init_utci_collection_full_input():
    """Test the initialization of the UTCI collection will all inputs."""
    calc_length = 24
    air_temp_header = Header(Temperature(), 'C', AnalysisPeriod(end_month=1, end_day=1))
    air_temp = HourlyContinuousCollection(air_temp_header, [24] * calc_length)
    custom_par = UTCIParameter(8, 25, -41, -28, -14, -1, 27, 31, 37, 45)
    utci_obj = UTCI(air_temp, 50, 22, 0.5, custom_par)

    assert utci_obj.air_temperature[0] == 24
    assert utci_obj.rel_humidity[0] == 50
    assert utci_obj.rad_temperature[0] == 22
    assert utci_obj.wind_speed[0] == 0.5
    assert utci_obj.comfort_parameter.cold_thresh == 8
    assert utci_obj.comfort_parameter.heat_thresh == 25
    assert utci_obj.comfort_parameter.extreme_cold_thresh == -41
    assert utci_obj.comfort_parameter.very_strong_cold_thresh == -28
    assert utci_obj.comfort_parameter.strong_cold_thresh == -14
    assert utci_obj.comfort_parameter.moderate_cold_thresh == -1
    assert utci_obj.comfort_parameter.moderate_heat_thresh == 27
    assert utci_obj.comfort_parameter.strong_heat_thresh == 31
    assert utci_obj.comfort_parameter.very_strong_heat_thresh == 37
    assert utci_obj.comfort_parameter.extreme_heat_thresh == 45
Exemplo n.º 15
0
def universal_thermal_climate_index(
        epw_file: str,
        mean_radiant_temperature: HourlyContinuousCollection,
        wind: int = 1,
        evaporative_cooling: bool = False):
    """
    Calculate the Universal Thermal Climate Index
    :param epw_file: Weather-file with location and climatic conditions for simulation
    :param mean_radiant_temperature: Mean radiant temperature hourly collection
    :param wind: 0 if no wind to be included (0.01m/s), 1 if wind speed should use the values in the EPW file, or 2+ is wind is fixed at a speed of 2m/s+
    :return universal_thermal_climate_index:
    """

    # Read weather-file
    epw = EPW(epw_file)

    # Get wind-speed values based on user choice
    wind_speed = 0.01 if wind == 0 else epw.wind_speed if wind == 1 else wind

    # Recalculate dry-bulb temperature if evaporative cooling is to be introduced
    if evaporative_cooling:
        wbt = np.array(
            _wbt(epw.dry_bulb_temperature.values, epw.relative_humidity,
                 epw.atmospheric_station_pressure.values))
        dbt_ec = np.array(epw.dry_bulb_temperature.values) - (
            (np.array(epw.dry_bulb_temperature.values) - wbt) * 0.7)
        epw.dry_bulb_temperature.values = dbt_ec

    # Calculate UTCI values
    utci = UTCI(epw.dry_bulb_temperature, epw.relative_humidity,
                mean_radiant_temperature,
                wind_speed).universal_thermal_climate_index

    print("Universal Thermal Climate Index calculation completed")

    return utci
Exemplo n.º 16
0
            except ValueError as e:
                raise TypeError('input {} is not valid. Expected float or '
                                'DataCollection. Got {}'.format(
                                    input, type(input)))
    return input_list, data_colls


if all_required_inputs(ghenv.Component) and _run is True:
    # Process inputs and assign defaults.
    input_list = [_air_temp, _mrt_, _wind_vel_, _rel_humid]
    input, data_colls = extract_collections(input_list)

    if data_colls == []:
        # The inputs are all individual values.
        utci = universal_thermal_climate_index(input[0], float(input[1]),
                                               input[2], input[3])
        utci_par = UTCIParameter()
        comfort = utci_par.is_comfortable(utci)
        condition = utci_par.thermal_condition(utci)
        category = utci_par.thermal_condition_eleven_point(utci)
    else:
        # The inputs include Data Collections.
        if not isinstance(_air_temp, BaseCollection):
            _air_temp = data_colls[0].get_aligned_collection(
                float(_air_temp), Temperature(), 'C')

        comf_obj = UTCI(_air_temp, _rel_humid, _mrt_, _wind_vel_)
        utci = comf_obj.universal_thermal_climate_index
        comfort = comf_obj.is_comfortable
        condition = comf_obj.thermal_condition
        category = comf_obj.thermal_condition_eleven_point