Exemplo n.º 1
0
def test_network_network_consistency_inlets():
    nw = network(['water'])
    merge = nodes.merge('merge')
    sink = basics.sink('label')
    a = connection(merge, 'out1', sink, 'in1')
    nw.add_conns(a)
    nw.check_network()
Exemplo n.º 2
0
 def test_consistency_inlets(self):
     merge = nodes.merge('merge')
     sink = basics.sink('label')
     a = connection(merge, 'out1', sink, 'in1')
     self.nw.add_conns(a)
     with raises(TESPyNetworkError):
         self.nw.check_network()
Exemplo n.º 3
0
    def setup_network_individual_offdesign(self):
        """
        Set up network for individual offdesign tests.
        """
        self.nw = network(['H2O'], T_unit='C', p_unit='bar', v_unit='m3 / s')

        so = basics.source('source')
        sp = nodes.splitter('splitter', num_out=2)
        self.pump1 = turbomachinery.pump('pump 1')
        self.sc1 = heat_exchangers.solar_collector('collector field 1')
        v1 = piping.valve('valve1')
        self.pump2 = turbomachinery.pump('pump 2')
        self.sc2 = heat_exchangers.solar_collector('collector field 2')
        v2 = piping.valve('valve2')
        me = nodes.merge('merge', num_in=2)
        si = basics.sink('sink')

        self.pump1.set_attr(eta_s=0.8,
                            design=['eta_s'],
                            offdesign=['eta_s_char'])
        self.pump2.set_attr(eta_s=0.8,
                            design=['eta_s'],
                            offdesign=['eta_s_char'])
        self.sc1.set_attr(pr=0.95,
                          lkf_lin=3.33,
                          lkf_quad=0.011,
                          A=1252,
                          E=700,
                          Tamb=20,
                          eta_opt=0.92,
                          design=['pr'],
                          offdesign=['zeta'])
        self.sc2.set_attr(pr=0.95,
                          lkf_lin=3.5,
                          lkf_quad=0.011,
                          A=700,
                          E=800,
                          Tamb=20,
                          eta_opt=0.92,
                          design=['pr'],
                          offdesign=['zeta'])

        fl = {'H2O': 1}
        inlet = connection(so, 'out1', sp, 'in1', T=50, p=3, fluid=fl)
        outlet = connection(me, 'out1', si, 'in1', p=3)

        self.sp_p1 = connection(sp, 'out1', self.pump1, 'in1')
        self.p1_sc1 = connection(self.pump1, 'out1', self.sc1, 'in1')
        self.sc1_v1 = connection(self.sc1, 'out1', v1, 'in1', p=3.1, T=90)
        v1_me = connection(v1, 'out1', me, 'in1')

        self.sp_p2 = connection(sp, 'out2', self.pump2, 'in1')
        self.p2_sc2 = connection(self.pump2, 'out1', self.sc2, 'in1')
        self.sc2_v2 = connection(self.sc2, 'out1', v2, 'in1', p=3.1, m=0.1)
        v2_me = connection(v2, 'out1', me, 'in2')

        self.nw.add_conns(inlet, outlet, self.sp_p1, self.p1_sc1, self.sc1_v1,
                          v1_me, self.sp_p2, self.p2_sc2, self.sc2_v2, v2_me)
Exemplo n.º 4
0
air = source('ambient air')

# waste heat recovery
suph = heat_exchanger('superheater')
evap = heat_exchanger('evaporator')
drum = drum('drum')
eco = heat_exchanger('economizer')
ch = sink('chimney')

# steam turbine part
turb_hp = turbine('steam turbine high pressure')
cond_dh = condenser('district heating condenser')
mp_split = splitter('mp split')
turb_lp = turbine('steam turbine low pressure')
cond = condenser('condenser')
merge = merge('merge')
pump1 = pump('feed water pump 1')
pump2 = pump('feed water pump 2')
ls_out = sink('ls sink')
ls_in = source('ls source')
mp_valve = valve('mp valve')

# district heating
dh_in = source('district heating backflow')
dh_out = sink('district heating feedflow')

# cooling water
cw_in = source('cooling water backflow')
cw_out = sink('cooling water feedflow')

# %% connections