Exemplo n.º 1
0
    def setup_clausius_rankine(self, fluid_list):
        """Setup a Clausius-Rankine cycle."""
        self.nw = Network(fluids=fluid_list)
        self.nw.set_attr(p_unit='bar', T_unit='C', iterinfo=True)

        # %% components

        # main components
        turb = Turbine('turbine')
        con = Condenser('condenser')
        pu = Pump('pump')
        steam_generator = HeatExchangerSimple('steam generator')
        closer = CycleCloser('cycle closer')

        # cooling water
        so_cw = Source('cooling water inlet')
        si_cw = Sink('cooling water outlet')

        # %% connections

        # main cycle
        fs_in = Connection(closer, 'out1', turb, 'in1', label='livesteam')
        ws = Connection(turb, 'out1', con, 'in1', label='wastesteam')
        cond = Connection(con, 'out1', pu, 'in1', label='condensate')
        fw = Connection(pu, 'out1', steam_generator, 'in1', label='feedwater')
        fs_out = Connection(steam_generator, 'out1', closer, 'in1')
        self.nw.add_conns(fs_in, ws, cond, fw, fs_out)

        # cooling water
        cw_in = Connection(so_cw, 'out1', con, 'in2')
        cw_out = Connection(con, 'out2', si_cw, 'in1')
        self.nw.add_conns(cw_in, cw_out)

        # %% parametrization of components

        turb.set_attr(eta_s=0.9)
        con.set_attr(pr1=1, pr2=0.99, ttd_u=5)
        steam_generator.set_attr(pr=0.9)

        # %% parametrization of connections

        fs_in.set_attr(p=100, T=500, m=100, fluid={self.nw.fluids[0]: 1})
        fw.set_attr(h=200e3)
        cw_in.set_attr(T=20, p=5, fluid={self.nw.fluids[0]: 1})
        cw_out.set_attr(T=30)

        # %% solving
        self.nw.solve('design')
        pu.set_attr(eta_s=0.7)
        fw.set_attr(h=None)
        self.nw.solve('design')
Exemplo n.º 2
0
g_turb = Turbine('gas turbine')

CH4 = Source('fuel source')
air = Source('ambient air')

# waste heat recovery
suph = HeatExchanger('superheater')
evap = HeatExchanger('evaporator')
dr = Drum('drum')
eco = HeatExchanger('economizer')
dh_whr = HeatExchanger('waste heat recovery')
ch = Sink('chimney')

# steam turbine part
turb = Turbine('steam turbine')
cond = Condenser('condenser')
pu = Pump('feed water pump')
cc = CycleCloser('ls cycle closer')

# district heating
dh_in = Source('district heating backflow')
dh_out = Sink('district heating feedflow')

# %% connections
# gas turbine part
c_in = Connection(air, 'out1', comp, 'in1')
c_out = Connection(comp, 'out1', c_c, 'in1')
fuel = Connection(CH4, 'out1', c_c, 'in2')
gt_in = Connection(c_c, 'out1', g_turb, 'in1')
gt_out = Connection(g_turb, 'out1', suph, 'in1')
Exemplo n.º 3
0
# %% components

# sources & sinks
cc = CycleCloser('coolant cycle closer')
cc_cons = CycleCloser('consumer cycle closer')
amb = Source('ambient air')
amb_out1 = Sink('sink ambient 1')
amb_out2 = Sink('sink ambient 2')

# ambient air system
sp = Splitter('splitter')
fan = Compressor('fan')

# consumer system

cd = Condenser('condenser')
dhp = Pump('district heating pump')
cons = HeatExchangerSimple('consumer')

# evaporator system

ves = Valve('valve')
dr = Drum('drum')
ev = HeatExchanger('evaporator')
su = HeatExchanger('superheater')
erp = Pump('evaporator reciculation pump')

# compressor-system

cp1 = Compressor('compressor 1')
cp2 = Compressor('compressor 2')
    def setup(self):
        """
        Full model validation of SEGS model in TESPy vs. EBSILON.

        Find original models at https://github.com/fwitte/SEGS_exergy.
        """
        # specification of ambient state
        self.pamb = 1.013
        self.Tamb = 25

        # setting up network
        self.nw = Network(fluids=['water', 'INCOMP::TVP1', 'air'])
        self.nw.set_attr(T_unit='C',
                         p_unit='bar',
                         h_unit='kJ / kg',
                         m_unit='kg / s',
                         s_unit="kJ / kgK")

        # components definition
        air_in = Source('Ambient air source', fkt_group='CW')
        air_out = Sink('Ambient air sink', fkt_group='CW')

        closer_pt = CycleCloser('Cycle closer pt', fkt_group='SF')
        pt = ParabolicTrough('Parabolic trough', fkt_group='SF')
        ptpump = Pump('HTF pump', fkt_group='SF')

        closer = CycleCloser('Cycle closer power cycle', fkt_group='SG')

        eco = HeatExchanger('Economizer', fkt_group='SG')
        eva = HeatExchanger('Evaporator', fkt_group='SG')
        sup = HeatExchanger('Superheater', fkt_group='SG')
        drum = Drum('Drum', fkt_group='SG')

        reh = HeatExchanger('Reheater', fkt_group='RH')

        hpt1 = Turbine('HP turbine 1', fkt_group='HPT')
        hpt2 = Turbine('HP turbine 2', fkt_group='HPT')
        lpt1 = Turbine('LP turbine 1', fkt_group='LPT')
        lpt2 = Turbine('LP turbine 2', fkt_group='LPT')
        lpt3 = Turbine('LP turbine 3', fkt_group='LPT')
        lpt4 = Turbine('LP turbine 4', fkt_group='LPT')
        lpt5 = Turbine('LP turbine 5', fkt_group='LPT')

        cond = Condenser('Condenser', fkt_group='CW')
        condpump = Pump('Condenser pump', fkt_group='CW')
        fwt = Merge('Feedwater tank', num_in=3, fkt_group='LPP')
        fwp = Pump('Feedwater pump', fkt_group='FWP')
        cwp = Pump('Cooling water pump', fkt_group='CW')
        closer_cw = CycleCloser('Cycle closer cw', fkt_group='CW')
        ct = HeatExchanger('Cooling tower', fkt_group='CW')
        fan = Compressor('Cooling tower fan', fkt_group='CW')

        sp1 = Splitter('Splitter 1', fkt_group='HPT')
        sp2 = Splitter('Splitter 2', fkt_group='HPT')
        sp3 = Splitter('Splitter 3', fkt_group='LPT')
        sp4 = Splitter('Splitter 4', fkt_group='LPT')
        sp5 = Splitter('Splitter 5', fkt_group='LPT')
        sp6 = Splitter('Splitter 6', fkt_group='LPT')
        sp7 = Splitter('Splitter 7', fkt_group='SF')

        m1 = Merge('Merge 1', fkt_group='CW')
        m2 = Merge('Merge 2', fkt_group='HPP')
        m3 = Merge('Merge 3', fkt_group='LPP')
        m4 = Merge('Merge 4', fkt_group='LPP')
        m5 = Merge('Merge 5', fkt_group='SF')

        v1 = Valve('Valve 1', fkt_group='HPP')
        v2 = Valve('Valve 2', fkt_group='HPP')
        v3 = Valve('Valve 3', fkt_group='LPP')
        v4 = Valve('Valve 4', fkt_group='LPP')
        v5 = Valve('Valve 5', fkt_group='LPP')

        hppre1 = Condenser('High pressure preheater 1', fkt_group='HPP')
        hppre2 = Condenser('High pressure preheater 2', fkt_group='HPP')
        hppre1_sub = HeatExchanger('High pressure preheater 1 subcooling',
                                   fkt_group='HPP')
        hppre2_sub = HeatExchanger('High pressure preheater 2 subcooling',
                                   fkt_group='HPP')

        lppre1 = Condenser('Low pressure preheater 1', fkt_group='LPP')
        lppre2 = Condenser('Low pressure preheater 2', fkt_group='LPP')
        lppre3 = Condenser('Low pressure preheater 3', fkt_group='LPP')
        lppre1_sub = HeatExchanger('Low pressure preheater 1 subcooling',
                                   fkt_group='LPP')
        lppre2_sub = HeatExchanger('Low pressure preheater 2 subcooling',
                                   fkt_group='LPP')
        lppre3_sub = HeatExchanger('Low pressure preheater 3 subcooling',
                                   fkt_group='LPP')

        # connections definition
        # power cycle
        c1 = Connection(sup, 'out2', closer, 'in1', label='1')
        c2 = Connection(closer, 'out1', hpt1, 'in1', label='2')
        c3 = Connection(hpt1, 'out1', sp1, 'in1', label='3')
        c4 = Connection(sp1, 'out1', hpt2, 'in1', label='4')
        c5 = Connection(hpt2, 'out1', sp2, 'in1', label='5')
        c6 = Connection(sp2, 'out1', reh, 'in2', label='6')
        c7 = Connection(reh, 'out2', lpt1, 'in1', label='7')
        c8 = Connection(lpt1, 'out1', sp3, 'in1', label='8')
        c9 = Connection(sp3, 'out1', lpt2, 'in1', label='9')
        c10 = Connection(lpt2, 'out1', sp4, 'in1', label='10')
        c11 = Connection(sp4, 'out1', lpt3, 'in1', label='11')
        c12 = Connection(lpt3, 'out1', sp5, 'in1', label='12')
        c13 = Connection(sp5, 'out1', lpt4, 'in1', label='13')
        c14 = Connection(lpt4, 'out1', sp6, 'in1', label='14')
        c15 = Connection(sp6, 'out1', lpt5, 'in1', label='15')
        c16 = Connection(lpt5, 'out1', m1, 'in1', label='16')
        c17 = Connection(m1, 'out1', cond, 'in1', label='17')
        c18 = Connection(cond, 'out1', condpump, 'in1', label='18')
        c19 = Connection(condpump, 'out1', lppre1, 'in2', label='19')
        # c19 = Connection(condpump, 'out1', lppre1_sub, 'in2', label='19')
        # c20 = Connection(lppre1_sub, 'out2', lppre1, 'in2', label='20')
        c21 = Connection(lppre1, 'out2', lppre2, 'in2', label='21')
        # c21 = Connection(lppre1, 'out2', lppre2_sub, 'in2', label='21')
        # c22 = Connection(lppre2_sub, 'out2', lppre2, 'in2', label='22')
        c23 = Connection(lppre2, 'out2', lppre3, 'in2', label='23')
        # c23 = Connection(lppre2, 'out2', lppre3_sub, 'in2', label='23')
        # c24 = Connection(lppre3_sub, 'out2', lppre3, 'in2', label='24')
        c25 = Connection(lppre3, 'out2', fwt, 'in1', label='25')
        c26 = Connection(fwt, 'out1', fwp, 'in1', label='26')
        c27 = Connection(fwp, 'out1', hppre1, 'in2', label='27')
        c29 = Connection(hppre1, 'out2', hppre2, 'in2', label='29')
        c31 = Connection(hppre2, 'out2', eco, 'in2', label='31')

        c36 = Connection(sp1, 'out2', hppre2, 'in1', label='36')
        c37 = Connection(hppre2, 'out1', v1, 'in1', label='37')
        c39 = Connection(v1, 'out1', m2, 'in2', label='39')
        c40 = Connection(sp2, 'out2', m2, 'in1', label='40')
        c41 = Connection(m2, 'out1', hppre1, 'in1', label='41')
        c42 = Connection(hppre1, 'out1', v2, 'in1', label='42')
        c44 = Connection(v2, 'out1', fwt, 'in2', label='44')
        c45 = Connection(sp3, 'out2', fwt, 'in3', label='45')
        c46 = Connection(sp4, 'out2', lppre3, 'in1', label='46')
        c47 = Connection(lppre3, 'out1', v3, 'in1', label='47')
        # c47 = Connection(lppre3, 'out1', lppre3_sub, 'in1', label='47')
        # c48 = Connection(lppre3_sub, 'out1', v3, 'in1', label='48')
        c49 = Connection(v3, 'out1', m3, 'in1', label='49')
        c50 = Connection(sp5, 'out2', m3, 'in2', label='50')
        c51 = Connection(m3, 'out1', lppre2, 'in1', label='51')
        c52 = Connection(lppre2, 'out1', v4, 'in1', label='52')
        # c52 = Connection(lppre2, 'out1', lppre2_sub, 'in1', label='52')
        # c53 = Connection(lppre2_sub, 'out1', v4, 'in1', label='53')
        c54 = Connection(v4, 'out1', m4, 'in2', label='54')
        c55 = Connection(sp6, 'out2', m4, 'in1', label='55')
        c56 = Connection(m4, 'out1', lppre1, 'in1', label='56')
        c57 = Connection(lppre1, 'out1', v5, 'in1', label='57')
        # c57 = Connection(lppre1, 'out1', lppre1_sub, 'in1', label='57')
        # c58 = Connection(lppre1_sub, 'out1', v5, 'in1', label='58')
        c59 = Connection(v5, 'out1', m1, 'in2', label='59')

        # components from subsystem
        c32 = Connection(eco, 'out2', drum, 'in1', label='32')
        c33 = Connection(drum, 'out1', eva, 'in2', label='33')
        c34 = Connection(eva, 'out2', drum, 'in2', label='34')
        c35 = Connection(drum, 'out2', sup, 'in2', label='35')
        c73 = Connection(sup, 'out1', eva, 'in1', label='73')
        c74 = Connection(eva, 'out1', eco, 'in1', label='74')

        # cooling water
        c60 = Connection(cond, 'out2', closer_cw, 'in1', label='60')
        c61 = Connection(closer_cw, 'out1', ct, 'in1', label='61')
        c62 = Connection(ct, 'out1', cwp, 'in1', label='62')
        c63 = Connection(cwp, 'out1', cond, 'in2', label='63')

        # cooling tower
        c64 = Connection(air_in, 'out1', fan, 'in1', label='64')
        c65 = Connection(fan, 'out1', ct, 'in2', label='65')
        c66 = Connection(ct, 'out2', air_out, 'in1', label='66')

        # parabolic trough cycle
        c70 = Connection(pt, 'out1', closer_pt, 'in1', label='67')
        c71 = Connection(closer_pt, 'out1', sp7, 'in1', label='71')
        c72 = Connection(sp7, 'out1', sup, 'in1', label='72')
        c75 = Connection(eco, 'out1', m5, 'in1', label='75')
        c76 = Connection(sp7, 'out2', reh, 'in1', label='76')
        c77 = Connection(reh, 'out1', m5, 'in2', label='77')
        c78 = Connection(m5, 'out1', ptpump, 'in1', label='78')
        c79 = Connection(ptpump, 'out1', pt, 'in1', label='79')

        # add connections to network
        self.nw.add_conns(c1, c2, c3, c4, c5, c6, c7, c8, c9, c10, c11, c12,
                          c13, c14, c15, c16, c17, c18, c19, c21, c23, c25,
                          c26, c27, c29, c31, c32, c33, c34, c35, c36, c37,
                          c39, c40, c41, c42, c44, c45, c46, c47, c49, c50,
                          c51, c52, c54, c55, c56, c57, c59, c60, c61, c62,
                          c63, c64, c65, c66, c70, c71, c72, c73, c74, c75,
                          c76, c77, c78, c79)

        # power bus
        power = Bus('total output power')
        power.add_comps({
            'comp': hpt1,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': hpt2,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt1,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt2,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt3,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt4,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt5,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': fwp,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': condpump,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': ptpump,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': cwp,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': fan,
            'char': 0.95,
            'base': 'bus'
        })

        heat_input_bus = Bus('heat input')
        heat_input_bus.add_comps({'comp': pt, 'base': 'bus'})

        exergy_loss_bus = Bus('exergy loss')
        exergy_loss_bus.add_comps({
            'comp': air_in,
            'base': 'bus'
        }, {'comp': air_out})

        self.nw.add_busses(power, heat_input_bus, exergy_loss_bus)

        # component parameters
        pt.set_attr(doc=0.95,
                    aoi=0,
                    Tamb=25,
                    A='var',
                    eta_opt=0.73,
                    c_1=0.00496,
                    c_2=0.000691,
                    E=1000,
                    iam_1=1,
                    iam_2=1)

        ptpump.set_attr(eta_s=0.6)

        eco.set_attr()
        eva.set_attr(ttd_l=5)
        sup.set_attr()

        hpt1.set_attr(eta_s=0.8376)
        hpt2.set_attr(eta_s=0.8463)
        lpt1.set_attr(eta_s=0.8623)
        lpt2.set_attr(eta_s=0.917)
        lpt3.set_attr(eta_s=0.9352)
        lpt4.set_attr(eta_s=0.88)
        lpt5.set_attr(eta_s=0.6445)

        cond.set_attr(pr1=1, pr2=0.9, ttd_u=5)
        condpump.set_attr(eta_s=0.7)
        fwp.set_attr(eta_s=0.7)
        cwp.set_attr(eta_s=0.7)
        ct.set_attr(pr1=0.95)
        fan.set_attr(eta_s=0.6)

        lppre1.set_attr(pr1=1, ttd_u=5)
        lppre2.set_attr(pr1=1, ttd_u=5)
        lppre3.set_attr(pr1=1, ttd_u=5)
        hppre1.set_attr(pr1=1, ttd_u=5)
        hppre2.set_attr(pr1=1, ttd_u=5)

        lppre1_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        lppre2_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        lppre3_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        hppre1_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        hppre2_sub.set_attr(pr1=1, pr2=1, ttd_l=10)

        # connection parameters
        # parabolic trough cycle
        c70.set_attr(fluid={'TVP1': 1, 'water': 0, 'air': 0}, T=390, p=23.304)
        c76.set_attr(m=Ref(c70, 0.1284, 0))
        c73.set_attr(p=22.753)
        c74.set_attr(p=21.167)
        c78.set_attr(p=20.34)
        c79.set_attr(p=41.024)

        # cooling water
        c62.set_attr(fluid={
            'TVP1': 0,
            'water': 1,
            'air': 0
        },
                     T=30,
                     p=self.pamb)
        # cooling tower
        c64.set_attr(fluid={
            'water': 0,
            'TVP1': 0,
            'air': 1
        },
                     p=self.pamb,
                     T=self.Tamb)
        c65.set_attr(p=self.pamb + 0.0005)
        c66.set_attr(p=self.pamb, T=30)
        # power cycle
        c32.set_attr(Td_bp=-2)
        c34.set_attr(x=0.5)
        c1.set_attr(fluid={'water': 1, 'TVP1': 0, 'air': 0}, p=100, T=371)

        # steam generator pressure values
        c31.set_attr(p=103.56)
        c35.set_attr(p=103.42)

        # turbine pressure values
        c3.set_attr(p=33.61, m=38.969)
        c5.set_attr(p=18.58)
        c7.set_attr(p=17.1, T=371)
        c8.set_attr(p=7.98)
        c10.set_attr(p=2.73)
        c12.set_attr(p=0.96)
        c14.set_attr(p=0.29)

        # preheater pressure values
        c19.set_attr(p=14.755, state='l')
        c21.set_attr(p=9.9975, state='l')
        c23.set_attr(p=8.7012, state='l')
        c25.set_attr(state='l')

        c27.set_attr(p=125)
        c29.set_attr(p=112)

        # condensation
        c16.set_attr(p=0.08)

        # feedwater tank
        c26.set_attr(x=0)

        # a stable solution is generated for parts of the network
        self.nw.solve(mode='design')

        self.nw.del_conns(c19, c21, c23, c27, c29, c37, c42, c47, c52, c57)

        c19 = Connection(condpump, 'out1', lppre1_sub, 'in2', label='19')
        c20 = Connection(lppre1_sub, 'out2', lppre1, 'in2', label='20')
        c21 = Connection(lppre1, 'out2', lppre2_sub, 'in2', label='21')
        c22 = Connection(lppre2_sub, 'out2', lppre2, 'in2', label='22')
        c23 = Connection(lppre2, 'out2', lppre3_sub, 'in2', label='23')
        c24 = Connection(lppre3_sub, 'out2', lppre3, 'in2', label='24')

        c27 = Connection(fwp, 'out1', hppre1_sub, 'in2', label='27')
        c28 = Connection(hppre1_sub, 'out2', hppre1, 'in2', label='28')
        c29 = Connection(hppre1, 'out2', hppre2_sub, 'in2', label='29')
        c30 = Connection(hppre2_sub, 'out2', hppre2, 'in2', label='30')

        c37 = Connection(hppre2, 'out1', hppre2_sub, 'in1', label='37')
        c38 = Connection(hppre2_sub, 'out1', v1, 'in1', label='38')
        c42 = Connection(hppre1, 'out1', hppre1_sub, 'in1', label='42')
        c43 = Connection(hppre1_sub, 'out1', v2, 'in1', label='43')

        c47 = Connection(lppre3, 'out1', lppre3_sub, 'in1', label='47')
        c48 = Connection(lppre3_sub, 'out1', v3, 'in1', label='48')
        c52 = Connection(lppre2, 'out1', lppre2_sub, 'in1', label='52')
        c53 = Connection(lppre2_sub, 'out1', v4, 'in1', label='53')
        c57 = Connection(lppre1, 'out1', lppre1_sub, 'in1', label='57')
        c58 = Connection(lppre1_sub, 'out1', v5, 'in1', label='58')

        self.nw.add_conns(c19, c20, c21, c22, c23, c24, c27, c28, c29, c30,
                          c37, c38, c42, c43, c47, c48, c52, c53, c57, c58)

        # specification of missing parameters
        c19.set_attr(p=14.755)
        c21.set_attr(p=9.9975, state='l')
        c23.set_attr(p=8.7012, state='l')
        c27.set_attr(p=125)
        c29.set_attr(p=112)

        # solve final state
        self.nw.solve(mode='design')
Exemplo n.º 5
0
# mean geothermal temperature (mean value of ground feed and return flow)
Tgeo = 9.5

nw = Network(fluids=['water', 'R410A'],
             T_unit='C',
             p_unit='bar',
             h_unit='kJ / kg',
             m_unit='kg / s')

# %% components

cc = CycleCloser('cycle closer')

# heat pump system
cd = Condenser('condenser')
va = Valve('valve')
ev = HeatExchanger('evaporator')
cp = Compressor('compressor')

# geothermal heat collector
gh_in = Source('ground heat feed flow')
gh_out = Sink('ground heat return flow')
ghp = Pump('ground heat loop pump')

# heating system
hs_feed = Sink('heating system feed flow')
hs_ret = Source('heating system return flow')
hsp = Pump('heating system pump')

# %% connections
    def __init__(self):
        self.nw = Network(fluids=['BICUBIC::water'],
                          p_unit='bar',
                          T_unit='C',
                          h_unit='kJ / kg',
                          iterinfo=False)
        # components
        # main cycle
        eco = HeatExchangerSimple('economizer')
        eva = HeatExchangerSimple('evaporator')
        sup = HeatExchangerSimple('superheater')
        cc = CycleCloser('cycle closer')
        hpt = Turbine('high pressure turbine')
        sp1 = Splitter('splitter 1', num_out=2)
        mpt = Turbine('mid pressure turbine')
        sp2 = Splitter('splitter 2', num_out=2)
        lpt = Turbine('low pressure turbine')
        con = Condenser('condenser')
        pu1 = Pump('feed water pump')
        fwh1 = Condenser('feed water preheater 1')
        fwh2 = Condenser('feed water preheater 2')
        dsh = Desuperheater('desuperheater')
        me2 = Merge('merge2', num_in=2)
        pu2 = Pump('feed water pump 2')
        pu3 = Pump('feed water pump 3')
        me = Merge('merge', num_in=2)

        # cooling water
        cwi = Source('cooling water source')
        cwo = Sink('cooling water sink')

        # connections
        # main cycle
        cc_hpt = Connection(cc, 'out1', hpt, 'in1', label='feed steam')
        hpt_sp1 = Connection(hpt, 'out1', sp1, 'in1', label='extraction1')
        sp1_mpt = Connection(sp1, 'out1', mpt, 'in1', state='g')
        mpt_sp2 = Connection(mpt, 'out1', sp2, 'in1', label='extraction2')
        sp2_lpt = Connection(sp2, 'out1', lpt, 'in1')
        lpt_con = Connection(lpt, 'out1', con, 'in1')
        con_pu1 = Connection(con, 'out1', pu1, 'in1')
        pu1_fwh1 = Connection(pu1, 'out1', fwh1, 'in2')
        fwh1_me = Connection(fwh1, 'out2', me, 'in1', state='l')
        me_fwh2 = Connection(me, 'out1', fwh2, 'in2', state='l')
        fwh2_dsh = Connection(fwh2, 'out2', dsh, 'in2', state='l')
        dsh_me2 = Connection(dsh, 'out2', me2, 'in1')
        me2_eco = Connection(me2, 'out1', eco, 'in1', state='l')
        eco_eva = Connection(eco, 'out1', eva, 'in1')
        eva_sup = Connection(eva, 'out1', sup, 'in1')
        sup_cc = Connection(sup, 'out1', cc, 'in1')

        self.nw.add_conns(cc_hpt, hpt_sp1, sp1_mpt, mpt_sp2, sp2_lpt, lpt_con,
                          con_pu1, pu1_fwh1, fwh1_me, me_fwh2, fwh2_dsh,
                          dsh_me2, me2_eco, eco_eva, eva_sup, sup_cc)

        # cooling water
        cwi_con = Connection(cwi, 'out1', con, 'in2')
        con_cwo = Connection(con, 'out2', cwo, 'in1')

        self.nw.add_conns(cwi_con, con_cwo)

        # preheating
        sp1_dsh = Connection(sp1, 'out2', dsh, 'in1')
        dsh_fwh2 = Connection(dsh, 'out1', fwh2, 'in1')
        fwh2_pu2 = Connection(fwh2, 'out1', pu2, 'in1')
        pu2_me2 = Connection(pu2, 'out1', me2, 'in2')

        sp2_fwh1 = Connection(sp2, 'out2', fwh1, 'in1')
        fwh1_pu3 = Connection(fwh1, 'out1', pu3, 'in1')
        pu3_me = Connection(pu3, 'out1', me, 'in2')

        self.nw.add_conns(sp1_dsh, dsh_fwh2, fwh2_pu2, pu2_me2, sp2_fwh1,
                          fwh1_pu3, pu3_me)

        # busses
        # power bus
        self.power = Bus('power')
        self.power.add_comps({
            'comp': hpt,
            'char': -1
        }, {
            'comp': mpt,
            'char': -1
        }, {
            'comp': lpt,
            'char': -1
        }, {
            'comp': pu1,
            'char': -1
        }, {
            'comp': pu2,
            'char': -1
        }, {
            'comp': pu3,
            'char': -1
        })

        # heating bus
        self.heat = Bus('heat')
        self.heat.add_comps({
            'comp': eco,
            'char': 1
        }, {
            'comp': eva,
            'char': 1
        }, {
            'comp': sup,
            'char': 1
        })

        self.nw.add_busses(self.power, self.heat)

        # parametrization
        # components
        hpt.set_attr(eta_s=0.9)
        mpt.set_attr(eta_s=0.9)
        lpt.set_attr(eta_s=0.9)

        pu1.set_attr(eta_s=0.8)
        pu2.set_attr(eta_s=0.8)
        pu3.set_attr(eta_s=0.8)

        eco.set_attr(pr=0.99)
        eva.set_attr(pr=0.99)
        sup.set_attr(pr=0.99)

        con.set_attr(pr1=1, pr2=0.99, ttd_u=5)
        fwh1.set_attr(pr1=1, pr2=0.99, ttd_u=5)
        fwh2.set_attr(pr1=1, pr2=0.99, ttd_u=5)
        dsh.set_attr(pr1=0.99, pr2=0.99)

        # connections
        eco_eva.set_attr(x=0)
        eva_sup.set_attr(x=1)

        cc_hpt.set_attr(m=200, T=650, p=100, fluid={'water': 1})
        hpt_sp1.set_attr(p=20)
        mpt_sp2.set_attr(p=3)
        lpt_con.set_attr(p=0.05)

        cwi_con.set_attr(T=20, p=10, fluid={'water': 1})

        # test run
        self.nw.solve('design')
        document_model(self.nw)
Exemplo n.º 7
0
    def __init__(self, working_fluid):
        """Set up model."""
        self.working_fluid = working_fluid
        fluids = ['water', self.working_fluid, 'air']
        self.nw = Network(fluids=fluids)
        self.nw.set_attr(p_unit='bar', T_unit='C', h_unit='kJ / kg')

        # geo parameters

        self.geo_mass_flow = 200
        geo_steam_share = 0.1
        self.T_brine_in = 140

        # ambient parameters

        self.T_amb = 5
        self.p_amb = 0.6

        # main components

        geo_steam = Source('geosteam source')
        geo_brine = Source('geobrine source')
        geo_reinjection = Sink('re-injection')

        air_in = Source('air source')
        air_out = Sink('air sink')
        air_fan = Compressor('air fan')
        air_cond = Condenser('condenser')

        orc_cc = CycleCloser('orc cycle closer')

        evap_splitter = Splitter('splitter evaporation')
        evap_merge = Merge('merge evaporation')
        evap_steam = Condenser('geosteam evaporator')
        evap_brine = HeatExchanger('geobrine evaporator')
        dr = Drum('drum')
        geo_merge = Merge('merge brine')

        pre = HeatExchanger('preheater')
        feed_working_fluid_pump = Pump('feed pump')

        tur = Turbine('turbine')

        ihe = HeatExchanger('internal heat exchanger')

        # busses
        net_power = Bus('net power output')
        net_power.add_comps(
            {'comp': tur, 'char': 0.97},
            {'comp': feed_working_fluid_pump, 'char': 0.97, 'base': 'bus'},
            {'comp': air_fan, 'char': 0.97, 'base': 'bus'}
        )

        ORC_power_bus = Bus('cycle gross power output')
        ORC_power_bus.add_comps(
            {'comp': tur}, {'comp': feed_working_fluid_pump}
        )

        geothermal_bus = Bus('thermal input')
        geothermal_bus.add_comps(
            {'comp': pre, 'char': -1}, {'comp': evap_brine, 'char': -1},
            {'comp': evap_steam, 'char': -1}
        )

        self.nw.add_busses(net_power, ORC_power_bus, geothermal_bus)

        # turbine to condenser
        c1 = Connection(orc_cc, 'out1', tur, 'in1', label='1')
        c2 = Connection(tur, 'out1', ihe, 'in1', label='2')
        c3 = Connection(ihe, 'out1', air_cond, 'in1', label='3')
        self.nw.add_conns(c1, c2, c3)

        # condenser to steam generator
        c4 = Connection(air_cond, 'out1', feed_working_fluid_pump, 'in1', label='4')
        c5 = Connection(feed_working_fluid_pump, 'out1', ihe, 'in2', label='5')
        self.nw.add_conns(c4, c5)

        # steam generator
        c6 = Connection(ihe, 'out2', pre, 'in2', label='6')
        c7 = Connection(pre, 'out2', dr, 'in1', label='7')
        c8 = Connection(dr, 'out1', evap_splitter, 'in1', label='8')
        c9 = Connection(evap_splitter, 'out2', evap_steam, 'in2', label='9')
        c10 = Connection(evap_steam, 'out2', evap_merge, 'in2', label='10')
        c11 = Connection(evap_splitter, 'out1', evap_brine, 'in2', label='11')
        c12 = Connection(evap_brine, 'out2', evap_merge, 'in1', label='12')
        c13 = Connection(evap_merge, 'out1', dr, 'in2', label='13')
        c0 = Connection(dr, 'out2', orc_cc, 'in1', label='0')
        self.nw.add_conns(c6, c7, c8, c11, c9, c12, c10, c13, c0)

        # condenser cold side
        c20 = Connection(air_in, 'out1', air_fan, 'in1', label='20')
        c21 = Connection(air_fan, 'out1', air_cond, 'in2', label='21')
        c22 = Connection(air_cond, 'out2', air_out, 'in1', label='22')
        self.nw.add_conns(c20, c21, c22)

        # geo source
        c30 = Connection(geo_steam, 'out1', evap_steam, 'in1', label='30')
        c31 = Connection(evap_steam, 'out1',  geo_merge, 'in1', label='31')
        c32 = Connection(geo_brine, 'out1', geo_merge, 'in2', label='32')
        c33 = Connection(geo_merge, 'out1', evap_brine, 'in1', label='33')
        self.nw.add_conns(c30, c31, c32, c33)

        c34 = Connection(evap_brine, 'out1', pre, 'in1', label='34')
        c35 = Connection(pre, 'out1', geo_reinjection, 'in1', label='35')
        self.nw.add_conns(c34, c35)

        # generate a set of stable starting values of every working fluid
        # fluid settings
        c6.set_attr(fluid={self.working_fluid: 1.0, 'air': 0.0, 'water': 0.0})
        c20.set_attr(fluid={self.working_fluid: 0.0, 'air': 1.0, 'water': 0.0})
        c30.set_attr(fluid={self.working_fluid: 0.0, 'air': 0.0, 'water': 1.0})
        c32.set_attr(fluid={self.working_fluid: 0.0, 'air': 0.0, 'water': 1.0})

        # connection parameters
        p0 = PSI('P', 'T', self.T_brine_in + 273.15, 'Q', 1, self.working_fluid)
        c1.set_attr(p0=p0 / 1e5)
        ws_stable_h0 = (
            PSI('H', 'T', self.T_amb + 273.15, 'Q', 1, self.working_fluid) +
            0.5 * (
                PSI('H', 'T', self.T_brine_in + 273.15, 'Q', 1, self.working_fluid) -
                PSI('H', 'T', self.T_amb + 273.15, 'Q', 1, self.working_fluid)
            )
        ) / 1e3
        c2.set_attr(h=ws_stable_h0)
        p0 = PSI('P', 'T', self.T_amb + 273.15, 'Q', 1, self.working_fluid)
        c3.set_attr(Td_bp=5, design=['Td_bp'], p0=p0 / 1e5)
        c5.set_attr(h=Ref(c4, 1, 1))

        # steam generator
        c30.set_attr(
            m=self.geo_mass_flow * geo_steam_share,
            T=self.T_brine_in, x=1, p0=5)
        c32.set_attr(
            m=self.geo_mass_flow * (1 - geo_steam_share),
            T=self.T_brine_in, x=0)

        c13.set_attr()
        c12.set_attr(x=0.5)
        c10.set_attr(x=0.5, design=['x'])
        c34.set_attr(h=Ref(c33, 1, -50))

        c7.set_attr(Td_bp=-2)

        # main condenser
        c20.set_attr(p=self.p_amb, T=self.T_amb)
        c22.set_attr(T=self.T_amb + 15, p=self.p_amb)

        # component parameters
        # condensing
        ihe.set_attr(pr1=0.98, pr2=0.98)
        air_cond.set_attr(pr1=1, pr2=0.995, ttd_u=10)
        air_fan.set_attr(eta_s=0.6)

        # steam generator
        evap_brine.set_attr(pr1=0.98, ttd_l=8)
        pre.set_attr(pr1=0.98, pr2=0.98)

        self.nw.set_attr(iterinfo=False)
        self.nw.solve('design')
        self.nw.save('stable_' + self.working_fluid)

        # specify actual parameters
        tur.set_attr(eta_s=0.9)
        feed_working_fluid_pump.set_attr(eta_s=0.75)
        c2.set_attr(h=None)
        c5.set_attr(h=None)
        c34.set_attr(h=None, T=Ref(c33, 1, -10))

        self.nw.solve('design')
        c22.set_attr(T=None)
        c3.set_attr(Td_bp=None)

        self.ude_IHE_size = UserDefinedEquation(
            label='ihe deshuperheat ratio',
            func=desuperheat, deriv=desuperheat_deriv,
            latex={
                'equation':
                    r'0 = h_3 - h_2 - x_\mathrm{IHE} \cdot \left(h_3 -'
                    r'h\left(p_2, T_5 + \Delta T_\mathrm{t,u,min} \right)'
                    r'\right)'},
            conns=[
                self.nw.get_conn('2'),
                self.nw.get_conn('3'),
                self.nw.get_conn('5')],
            params={'distance': 0.0, 'ttd_min': 2}
        )
        if self.nw.lin_dep or self.nw.res[-1] > 1e-3:
            msg = 'No stable solution found.'
            raise TESPyNetworkError(msg)
        print(
            'Generated stable starting values for working fluid ' +
            self.working_fluid + '.')
Exemplo n.º 8
0
    def test_Condenser(self):
        """Test component properties of Condenser."""
        instance = Condenser('condenser')
        self.setup_HeatExchanger_network(instance)

        # design specification
        instance.set_attr(pr1=0.98, pr2=0.98, ttd_u=5,
                          offdesign=['zeta2', 'kA_char'])
        self.c1.set_attr(T=100, p0=0.5, fluid={'Ar': 0, 'H2O': 1, 'S800': 0})
        self.c3.set_attr(T=30, p=5, fluid={'Ar': 0, 'H2O': 1, 'S800': 0})
        self.c4.set_attr(T=40)
        instance.set_attr(Q=-80e3)
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)
        self.nw.save('tmp')
        Q_design = instance.Q.val

        # test specified kA value
        instance.set_attr(kA=instance.kA.val * 2 / 3, Q=None)
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)

        # test heat transfer
        Q = self.c1.m.val_SI * (self.c2.h.val_SI - self.c1.h.val_SI)
        msg = (
            'Value of heat flow must be ' + str(round(Q_design * 2 / 3, 0)) +
            ', is ' + str(round(Q, 0)) + '.')
        assert round(Q, 1) == round(Q_design * 2 / 3, 1), msg

        # back to design case
        instance.set_attr(kA=None, Q=Q_design)
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)

        # test heat transfer
        Q = self.c1.m.val_SI * (self.c2.h.val_SI - self.c1.h.val_SI)
        msg = ('Value of heat flow must be ' + str(round(instance.Q.val, 0)) +
               ', is ' + str(round(Q, 0)) + '.')
        assert round(Q, 1) == round(instance.Q.val, 1), msg

        # test upper terminal temperature difference. For the component
        # condenser the temperature of the condensing fluid is relevant.
        ttd_u = round(T_bp_p(self.c1.get_flow()) - self.c4.T.val_SI, 1)
        p = round(self.c1.p.val_SI, 5)
        msg = ('Value of terminal temperature difference must be ' +
               str(round(instance.ttd_u.val, 1)) + ', is ' +
               str(ttd_u) + '.')
        assert ttd_u == round(instance.ttd_u.val, 1), msg

        # test lower terminal temperature difference
        instance.set_attr(ttd_l=20, ttd_u=np.nan, design=['pr2', 'ttd_l'])
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)
        msg = ('Value of terminal temperature difference must be ' +
               str(instance.ttd_l.val) + ', is ' +
               str(self.c2.T.val - self.c3.T.val) + '.')
        ttd_l_calc = round(self.c2.T.val - self.c3.T.val, 1)
        ttd_l = round(instance.ttd_l.val, 1)
        assert ttd_l_calc == ttd_l, msg

        # check kA value with condensing pressure in offdesign mode:
        # no changes to design point means: identical pressure
        self.nw.solve('offdesign', design_path='tmp')
        convergence_check(self.nw.lin_dep)
        msg = ('Value of condensing pressure be ' + str(p) + ', is ' +
               str(round(self.c1.p.val_SI, 5)) + '.')
        assert p == round(self.c1.p.val_SI, 5), msg
        shutil.rmtree('./tmp', ignore_errors=True)
Exemplo n.º 9
0
import numpy as np

# %% network

fluids = ['water']

nw = Network(fluids=fluids)
nw.set_attr(
    p_unit='bar', T_unit='C', h_unit='kJ / kg',
    p_range=[0.01, 150], h_range=[10, 5000])

# %% components

# main components
turb = Turbine('turbine')
con = Condenser('condenser')
pu = Pump('pump')
steam_generator = HeatExchangerSimple('steam generator')
closer = CycleCloser('cycle closer')

# cooling water
so_cw = Source('cooling water inlet')
si_cw = Sink('cooling water outlet')

# %% connections

# main cycle
fs_in = Connection(closer, 'out1', turb, 'in1')
ws = Connection(turb, 'out1', con, 'in1')
cond = Connection(con, 'out1', pu, 'in1')
fw = Connection(pu, 'out1', steam_generator, 'in1')
Exemplo n.º 10
0
c_c = CombustionChamber('combustion')
g_turb = Turbine('gas turbine')

CH4 = Source('fuel source')
air = Source('ambient air')

# waste heat recovery
suph = HeatExchanger('superheater')
evap = HeatExchanger('evaporator')
drum = Drum('drum')
eco = HeatExchanger('economizer')
ch = Sink('chimney')

# steam turbine part
turb_hp = Turbine('steam turbine high pressure')
cond_dh = Condenser('district heating condenser')
mp_split = Splitter('mp split')
turb_lp = Turbine('steam turbine low pressure')
cond = Condenser('condenser')
merge = Merge('merge')
pump1 = Pump('feed water pump 1')
pump2 = Pump('feed water pump 2')
ls_out = Sink('ls sink')
ls_in = Source('ls source')
mp_valve = Valve('mp valve')

# district heating
dh_in = Source('district heating backflow')
dh_out = Sink('district heating feedflow')

# cooling water
Exemplo n.º 11
0
fluid_list = ['BICUBIC::H2O']

nw = Network(fluids=fluid_list,
             p_unit='bar',
             T_unit='C',
             h_unit='kJ / kg',
             v_unit='l / s',
             iterinfo=False)

T_dh_in = 50
T_dh_out = 124  # might change due to 4GDH

# %% components

st = Turbine('steam Turbine')
con = Condenser('Condenser')
pu = Pump('feed water Pump')
sg1 = HeatExchangerSimple('steam generator: feed water heater')
sg2 = HeatExchangerSimple('steam generator: evaporater')
sg3 = HeatExchangerSimple('steam generator: superheater')
cc = CycleCloser('cycle closer')

dh_Source = Source('district heating Source')
dh_Sink = Sink('district heating Sink')

# %% Connection

# steam part
cc_st = Connection(cc, 'out1', st, 'in1')
st_con = Connection(st, 'out1', con, 'in1')
con_pu = Connection(con, 'out1', pu, 'in1')
Exemplo n.º 12
0
# %% network

fluids = ['water']

nw = Network(fluids=fluids, p_unit='bar', T_unit='C', h_unit='kJ / kg', iterinfo=False)

# %% components

# turbine part
valve_turb = Valve('turbine inlet valve')
turbine_hp = Turbine('high pressure turbine')
split = Splitter('extraction splitter')
turbine_lp = Turbine('low pressure turbine')

# condenser and preheater
cond = Condenser('condenser')
preheater = Condenser('preheater')
merge_ws = Merge('waste steam merge')
valve_pre = Valve('preheater valve')

# feed water
pump = Pump('pump')
steam_generator = HeatExchangerSimple('steam generator')

closer = CycleCloser('cycle closer')

# source and sink for cooling water
source_cw = Source('source_cw')
sink_cw = Sink('sink_cw')

# %% connections