def _populate_vnfd_drivers(self, drv_conf): vnfd_drv_cls_path = drv_conf['_driver'] try: drv_conf['_drv_obj'] = importutils.import_object(vnfd_drv_cls_path, self.ns_config) except Exception: LOG.warn(_("%s driver not Loaded"), vnfd_drv_cls_path) raise
def _populate_vnfd_drivers(self, drv_conf): vnfd_drv_cls_path = drv_conf['_driver'] username = drv_conf['_username'] password = drv_conf['_password'] lf_events = drv_conf['_lc_events'] try: drv_conf['_drv_obj'] = importutils.import_object(vnfd_drv_cls_path, self.ns_config, username = username, password = password) except Exception: LOG.warn(_("%s driver not Loaded"), vnfd_drv_cls_path) raise
def _populate_vnfd_drivers(self, drv_conf): vnfd_drv_cls_path = {} for event in drv_conf['_lc_events']: vnfd_drv_cls_path[event] = drv_conf[event]['_driver'] username = drv_conf['_username'] password = drv_conf['_password'] lf_events = drv_conf['_lc_events'] try: for event in drv_conf['_lc_events']: kwargs = { 'conf': self.ns_config, 'username': username, 'password': password } drv_conf[event]['_drv_obj'] = importutils.import_object( vnfd_drv_cls_path[event], **kwargs) except Exception: LOG.warn(_("%s driver not Loaded"), vnfd_drv_cls_path[event]) raise
def postConfigure(self, context, conf): LOG.debug(_(" In post configure")) for instance in conf['instances_list']: mgmt_ip = conf['mgmt-ip'][instance] _thr_id = str(uuid.generate_uuid()).split('-')[1] vdu = {} vdu['name'] = conf['vdu'] kwargs = { 'conf': self.ns_config, 'username': self.drv_conf[vdu['name']]['_username'], 'password': self.drv_conf[vdu['name']]['_password'] } drv_obj = importutils.import_object(conf['driver'], **kwargs) self.drv_conf[vdu['name']]['config'] = {} self.drv_conf[vdu['name']]['config']['_driver'] = conf['driver'] vdu['config'] = {} vdu['config']['_drv_obj'] = drv_obj method = 'postconfigure' arguments = conf['data'] configThread = ImplThread(self._configure_service, self._condition, vdu, instance, mgmt_ip, method, arguments, conf['event'], _id=_thr_id) self._condition.acquire() launchd_threads_info[_thr_id] = { 'vm_name': instance, 'thread_obj': configThread, 'vnfd': conf['vnf'], 'vdu': conf['vdu'], 'conf': conf, 'event': "postconfigure" } self._condition.release() configThread.start()
def _setup_logging_from_conf(project, version): log_root = getLogger(None).logger for handler in log_root.handlers: log_root.removeHandler(handler) if CONF.use_syslog: facility = _find_facility_from_conf() if CONF.use_syslog_rfc_format: syslog = RFCSysLogHandler(address='/dev/log', facility=facility) else: syslog = logging.handlers.SysLogHandler(address='/dev/log', facility=facility) log_root.addHandler(syslog) logpath = _get_log_file_path() if logpath: filelog = logging.handlers.WatchedFileHandler(logpath) log_root.addHandler(filelog) if CONF.use_stderr: streamlog = ColorHandler() log_root.addHandler(streamlog) elif not logpath: # pass sys.stdout as a positional argument # python2.6 calls the argument strm, in 2.7 it's stream streamlog = logging.StreamHandler(sys.stdout) log_root.addHandler(streamlog) if CONF.publish_errors: try: handler = importutils.import_object( "vnfmanager.openstack.common.log_handler.PublishErrorsHandler", logging.ERROR) except ImportError: handler = importutils.import_object( "oslo.messaging.notify.log_handler.PublishErrorsHandler", logging.ERROR) log_root.addHandler(handler) datefmt = CONF.log_date_format for handler in log_root.handlers: # NOTE(alaski): CONF.log_format overrides everything currently. This # should be deprecated in favor of context aware formatting. if CONF.log_format: handler.setFormatter(logging.Formatter(fmt=CONF.log_format, datefmt=datefmt)) log_root.info('Deprecated: log_format is now deprecated and will ' 'be removed in the next release') else: handler.setFormatter(ContextFormatter(project=project, version=version, datefmt=datefmt)) if CONF.debug: log_root.setLevel(logging.DEBUG) elif CONF.verbose: log_root.setLevel(logging.INFO) else: log_root.setLevel(logging.WARNING) for pair in CONF.default_log_levels: mod, _sep, level_name = pair.partition('=') logger = logging.getLogger(mod) # NOTE(AAzza) in python2.6 Logger.setLevel doesn't convert string name # to integer code. if sys.version_info < (2, 7): level = logging.getLevelName(level_name) logger.setLevel(level) else: logger.setLevel(level_name)
def _setup_logging_from_conf(project, version): log_root = getLogger(None).logger for handler in log_root.handlers: log_root.removeHandler(handler) if CONF.use_syslog: facility = _find_facility_from_conf() if CONF.use_syslog_rfc_format: syslog = RFCSysLogHandler(address="/dev/log", facility=facility) else: syslog = logging.handlers.SysLogHandler(address="/dev/log", facility=facility) log_root.addHandler(syslog) logpath = _get_log_file_path() if logpath: filelog = logging.handlers.WatchedFileHandler(logpath) log_root.addHandler(filelog) if CONF.use_stderr: streamlog = ColorHandler() log_root.addHandler(streamlog) elif not logpath: # pass sys.stdout as a positional argument # python2.6 calls the argument strm, in 2.7 it's stream streamlog = logging.StreamHandler(sys.stdout) log_root.addHandler(streamlog) if CONF.publish_errors: try: handler = importutils.import_object( "vnfmanager.openstack.common.log_handler.PublishErrorsHandler", logging.ERROR ) except ImportError: handler = importutils.import_object("oslo.messaging.notify.log_handler.PublishErrorsHandler", logging.ERROR) log_root.addHandler(handler) datefmt = CONF.log_date_format for handler in log_root.handlers: # NOTE(alaski): CONF.log_format overrides everything currently. This # should be deprecated in favor of context aware formatting. if CONF.log_format: handler.setFormatter(logging.Formatter(fmt=CONF.log_format, datefmt=datefmt)) log_root.info("Deprecated: log_format is now deprecated and will " "be removed in the next release") else: handler.setFormatter(ContextFormatter(project=project, version=version, datefmt=datefmt)) if CONF.debug: log_root.setLevel(logging.DEBUG) elif CONF.verbose: log_root.setLevel(logging.INFO) else: log_root.setLevel(logging.WARNING) for pair in CONF.default_log_levels: mod, _sep, level_name = pair.partition("=") logger = logging.getLogger(mod) # NOTE(AAzza) in python2.6 Logger.setLevel doesn't convert string name # to integer code. if sys.version_info < (2, 7): level = logging.getLevelName(level_name) logger.setLevel(level) else: logger.setLevel(level_name)
def _extract_monitor_drv(self): global _monitor_drv if self.monitor: LOG.debug(_("Loading Monitoring driver for the network service")) self._monitor_drv_path = _monitor_drv + self.monitor['driver'] self._monitor_driver = importutils.import_object(self._monitor_drv_path)