Exemplo n.º 1
0
 def test_failure(self, m):
     results = solver.solve(m)
     # check_solve should pass since fail_flag=False and only warning will be produced
     check_solve(results, logger=_log, fail_flag=False)
     # expect the solve to fail and raise error
     with pytest.raises(ValueError, match="The solver failed to converge to an optimal solution. This suggests that the "
                                          "user provided infeasible inputs or that the model is poorly scaled."):
         check_solve(results, logger=_log, fail_flag=True)
Exemplo n.º 2
0
    def test_success(self, m):
        m.acon.deactivate()

        results = solver.solve(m)
        # both check_solve's should pass
        check_solve(results, logger=_log, fail_flag=False)
        check_solve(results, logger=_log, fail_flag=True)

        m.acon.activate()
Exemplo n.º 3
0
    def initialize_build(blk,
                         initialize_guess=None,
                         state_args=None,
                         outlvl=idaeslog.NOTSET,
                         solver=None,
                         optarg=None,
                         fail_on_warning=False,
                         ignore_dof=False):
        """
        Initialization routine for 1D-RO unit.

        Keyword Arguments:
            initialize_guess : a dict of guesses for solvent_recovery, solute_recovery,
                               and cp_modulus. These guesses offset the initial values
                               for the retentate, permeate, and membrane interface
                               state blocks from the inlet feed
                               (default =
                               {'deltaP': -1e4,
                               'solvent_recovery': 0.5,
                               'solute_recovery': 0.01,
                               'cp_modulus': 1.1})
            state_args : a dict of arguments to be passed to the property
                         package(s) to provide an initial state for the inlet
                         feed side state block (see documentation of the specific
                         property package) (default = None).
            outlvl : sets output level of initialization routine
            solver : str indicating which solver to use during
                     initialization (default = None, use default solver)
            optarg : solver options dictionary object (default=None, use default solver options)
            fail_on_warning : boolean argument to fail or only produce  warning upon unsuccessful solve (default=False)
            ignore_dof : boolean argument to ignore when DOF != 0 (default=False)
        Returns:
            None

        """

        init_log = idaeslog.getInitLogger(blk.name, outlvl, tag="unit")
        solve_log = idaeslog.getSolveLogger(blk.name, outlvl, tag="unit")

        # Create solver
        opt = get_solver(solver, optarg)

        source = blk.feed_side.properties[blk.flowsheet().config.time.first(),
                                          blk.first_element]
        state_args = blk._get_state_args(source, blk.mixed_permeate[0],
                                         initialize_guess, state_args)

        # ---------------------------------------------------------------------
        # Step 1: Initialize feed_side, permeate_side, and mixed_permeate blocks
        flags_feed_side = blk.feed_side.initialize(
            outlvl=outlvl,
            optarg=optarg,
            solver=solver,
            state_args=state_args['feed_side'],
            hold_state=True)

        init_log.info("Initialization Step 1 Complete")
        if not ignore_dof:
            check_dof(blk, fail_flag=fail_on_warning, logger=init_log)
        # ---------------------------------------------------------------------
        # Initialize other state blocks
        # base properties on inlet state block

        flag_feed_side_properties_interface = blk.feed_side.properties_interface.initialize(
            outlvl=outlvl,
            optarg=optarg,
            solver=solver,
            state_args=state_args['interface'])
        flags_permeate_side = blk.permeate_side.initialize(
            outlvl=outlvl,
            optarg=optarg,
            solver=solver,
            state_args=state_args['permeate'])
        flags_mixed_permeate = blk.mixed_permeate.initialize(
            outlvl=outlvl,
            optarg=optarg,
            solver=solver,
            state_args=state_args['permeate'])
        init_log.info("Initialization Step 2 Complete.")

        # ---------------------------------------------------------------------
        # Solve unit
        with idaeslog.solver_log(solve_log, idaeslog.DEBUG) as slc:
            res = opt.solve(blk, tee=slc.tee)
            # occasionally it might be worth retrying a solve
            if not check_optimal_termination(res):
                init_log.warn(
                    "Trouble solving ReverseOsmosis1D unit model, trying one more time"
                )
                res = opt.solve(blk, tee=slc.tee)
        check_solve(res,
                    logger=init_log,
                    fail_flag=fail_on_warning,
                    checkpoint='Initialization Step 3')
        # ---------------------------------------------------------------------
        # Release Inlet state
        blk.feed_side.release_state(flags_feed_side, outlvl)
        init_log.info("Initialization Complete: {}".format(
            idaeslog.condition(res)))