Пример #1
0
    def _change_status(self, from_status, to_status):

        # Do we need to scale production on generators due to droop?
        if len(self._scale_area):
            scale_area = self._scale_area
        else:
            scale_area = MonsterPssPy.aareaint(-1, 1, 'NUMBER')[0]

        # Get total load
        s_total = self.get_pq(to_status)

        if self.status() == to_status:
            if to_status == ComponentStatus.off:
                raise PsseBaseException('Machine component already out of service.', None)
            else:
                raise PsseBaseException('Machine component already in service.', None)

        try:
            MonsterPssPy.machine_data(
                self.from_bus.number, self.identificator,
                [ComponentStatus.off.get_index()]
            )
            # Define SID for scale area
            sid = 2
            MonsterPssPy.bsys(sid, numarea=len(scale_area), areas=scale_area)
            # Scale with (3) incremental powers, (0) ignore machine
            # power limits, (0) No Q changes and (2) only type 2 and 3
            # buses.
            MonsterPssPy.scal(sid, 0, 0, [0, 0, 0, 2, 0], [0.0, s_total.real] + [0.0] * 5)

        except PsseBaseException:
            raise
Пример #2
0
    def _change_status(self, from_status, to_status):
        # Do we need to scale production on generators due to droop?
        if len(self._scale_area):
            scale_area = self._scale_area
        else:
            scale_area = MonsterPssPy.aareaint(-1, 1, 'NUMBER')[0]

        # Get total load
        try:
            s_total = MonsterPssPy.loddt2(self.from_bus.number, self.identificator, 'TOTAL', 'ACT')
        except PsseLoddtException as e:
            if to_status == ComponentStatus.on and e._ierr == 4:
                s_total = -e._value
            else:
                raise

        if self.status() == to_status:
            if to_status == ComponentStatus.off:
                raise PsseBaseException('Load component already out of service.', None)
            else:
                raise PsseBaseException('Load component already in service.', None)
        try:
            MonsterPssPy.load_chng(
                self.from_bus.number, self.identificator,
                intgar1=to_status.get_index()
            )
            # Define SID for scale area
            sid = 2
            MonsterPssPy.bsys(sid, numarea=len(scale_area), areas=scale_area)
            # Scale with (3) incremental powers, (0) ignore machine
            # power limits, (0) No Q changes and (2) only type 2 and 3
            # buses.
            MonsterPssPy.scal(sid, 0, 0, [0, 0, 0, 2, 0], [0.0, -s_total.real] + [0.0] * 5)

        except PsseBaseException:
            raise