Пример #1
0
    def _test_switch_configure(self):
        # last switch on first board
        self.net_cpu.expected_commands = {"SN:1F,01,04,04": "SN:P"}
        self.machine.default_platform.configure_switch(
            '0-31', SwitchConfig(debounce='auto', invert=0), {})
        self.advance_time_and_run(.1)
        self.assertFalse(self.net_cpu.expected_commands)

        # next should not work
        with self.assertRaises(AssertionError):
            self.machine.default_platform.configure_switch(
                '0-32', SwitchConfig(debounce='auto', invert=0), {})

        self.net_cpu.expected_commands = {"SN:47,01,04,04": "SN:P"}
        self.machine.default_platform.configure_switch(
            '3-15', SwitchConfig(debounce='auto', invert=0), {})
        self.advance_time_and_run(.1)
        self.assertFalse(self.net_cpu.expected_commands)

        # invalid board
        with self.assertRaises(AssertionError):
            self.machine.default_platform.configure_switch(
                '4-0', SwitchConfig(debounce='auto', invert=0), {})

        # last switch is 0x47. 0x48 = 72
        with self.assertRaises(AssertionError):
            self.machine.default_platform.configure_switch(
                '72', SwitchConfig(debounce='auto', invert=0), {})
Пример #2
0
    def _test_switch_configure(self):
        # configuring switches in PKONE does not generate any commands between the host and controller

        # last switch on first board
        self.machine.default_platform.configure_switch(
            '0-35', SwitchConfig(name="", debounce='auto', invert=0), {})
        self.advance_time_and_run(.1)

        # next should not work
        with self.assertRaises(AssertionError):
            self.machine.default_platform.configure_switch(
                '0-36', SwitchConfig(name="", debounce='auto', invert=0), {})

        # invalid board
        with self.assertRaises(AssertionError):
            self.machine.default_platform.configure_switch(
                '4-1', SwitchConfig(name="", debounce='auto', invert=0), {})

        # invalid switch (switch number begin at 1 and not 0)
        with self.assertRaises(AssertionError):
            self.machine.default_platform.configure_switch(
                '0-0', SwitchConfig(name="", debounce='auto', invert=0), {})
Пример #3
0
    def _initialize(self):
        yield from super()._initialize()
        self.platform = self.machine.get_platform_sections(
            'switches', self.config['platform'])

        if self.config['type'].upper() == 'NC':
            self.invert = 1

        self.recycle_secs = self.config['ignore_window_ms'] / 1000.0

        config = SwitchConfig(invert=self.invert,
                              debounce=self.config['debounce'])
        try:
            self.hw_switch = self.platform.configure_switch(
                self.config['number'], config, self.config['platform_settings'])
        except AssertionError as e:
            raise AssertionError("Failed to configure switch {} in platform. See error above".format(self.name)) from e

        self.add_handler(state=1, callback=self._post_events, callback_kwargs={"state": 1})
        self.add_handler(state=0, callback=self._post_events, callback_kwargs={"state": 0})

        if self.machine.config['mpf']['auto_create_switch_events']:
            self._create_activation_event(
                self.machine.config['mpf']['switch_event_active'].replace(
                    '%', self.name), 1)
            self._create_activation_event(
                self.machine.config['mpf']['switch_event_inactive'].replace(
                    '%', self.name), 0)

        for tag in self.tags:
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag), 1)
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag) + "_active", 1)
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag) + "_inactive", 0)

        for event in Util.string_to_lowercase_list(
                self.config['events_when_activated']):
            self._create_activation_event(event, 1)

        for event in Util.string_to_lowercase_list(
                self.config['events_when_deactivated']):
            self._create_activation_event(event, 0)
Пример #4
0
    def _initialize(self):
        self.platform = self.machine.get_platform_sections(
            'switches', self.config['platform'])

        if self.config['type'].upper() == 'NC':
            self.invert = 1

        self.recycle_secs = self.config['ignore_window_ms'] / 1000.0

        config = SwitchConfig(invert=self.invert,
                              debounce=self.config['debounce'])
        self.hw_switch = self.platform.configure_switch(
            self.config['number'], config, self.config['platform_settings'])

        if self.machine.config['mpf']['auto_create_switch_events']:
            self._create_activation_event(
                self.machine.config['mpf']['switch_event_active'].replace(
                    '%', self.name), 1)
            self._create_activation_event(
                self.machine.config['mpf']['switch_event_inactive'].replace(
                    '%', self.name), 0)

        for tag in self.tags:
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag), 1)
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag) + "_active", 1)
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag) + "_inactive", 0)

        for event in Util.string_to_lowercase_list(
                self.config['events_when_activated']):
            self._create_activation_event(event, 1)

        for event in Util.string_to_lowercase_list(
                self.config['events_when_deactivated']):
            self._create_activation_event(event, 0)
Пример #5
0
    async def _initialize(self):
        await super()._initialize()
        self.platform = self.machine.get_platform_sections(
            'switches', self.config['platform'])

        if self.config['type'].upper() == 'NC':
            self.invert = 1

        self.recycle_secs = self.config['ignore_window_ms'] / 1000.0

        config = SwitchConfig(name=self.name,
                              invert=self.invert,
                              debounce=self.config['debounce'])
        if not self.platform.features[
                'allow_empty_numbers'] and self.config['number'] is None:
            self.raise_config_error("Switch must have a number.", 1)

        try:
            self.hw_switch = self.platform.configure_switch(
                self.config['number'], config,
                self.config['platform_settings'])
        except AssertionError as e:
            raise ConfigFileError(
                "Failed to configure switch {} in platform. See error above".
                format(self.name), 2, self.class_label) from e

        if self.recycle_secs:
            self.add_handler(state=1,
                             callback=self._post_events_with_recycle,
                             callback_kwargs={"state": 1})
            self.add_handler(state=0,
                             callback=self._post_events_with_recycle,
                             callback_kwargs={"state": 0})
        else:
            self.add_handler(state=1,
                             callback=self._post_events,
                             callback_kwargs={"state": 1})
            self.add_handler(state=0,
                             callback=self._post_events,
                             callback_kwargs={"state": 0})

        if self.machine.config['mpf']['auto_create_switch_events']:
            self._create_activation_event(
                self.machine.config['mpf']['switch_event_active'].replace(
                    '%', self.name), 1)
            '''event: (name)_active
            desc: Posted when this switch becomes active.
            Note that this will only be posted if there is an event handler for it or if debug is set to True on this
            switch for performance reasons.
            '''
            self._create_activation_event(
                self.machine.config['mpf']['switch_event_inactive'].replace(
                    '%', self.name), 0)
            '''event: (name)_inactive
            desc: Posted when this switch becomes inactive.
            Note that this will only be posted if there is an event handler for it or if debug is set to True on this
            switch for performance reasons.
            '''

        for tag in self.tags:
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag), 1)
            '''event: sw_(tag)
            desc: Posted when a switch with this tag becomes active.
            Note that this will only be posted if there is an event handler for it or if debug is set to True on this
            switch for performance reasons.
            '''
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag) + "_active", 1)
            '''event: sw_(tag)_active
            desc: Posted when a switch with this tag becomes active.
            Note that this will only be posted if there is an event handler for it or if debug is set to True on this
            switch for performance reasons.
            '''
            self._create_activation_event(
                self.machine.config['mpf']['switch_tag_event'].replace(
                    '%', tag) + "_inactive", 0)
            '''event: sw_(tag)_inactive
            desc: Posted when a switch with this tag becomes inactive.
            Note that this will only be posted if there is an event handler for it or if debug is set to True on this
            switch for performance reasons.
            '''

        for event in Util.string_to_event_list(
                self.config['events_when_activated']):
            self._create_activation_event(event, 1)

        for event in Util.string_to_event_list(
                self.config['events_when_deactivated']):
            self._create_activation_event(event, 0)