Пример #1
0
def updateiodata(database):
    # This recreates all input and output tables based on the interfaces table.
    # Thus way we don't keep around stale data values. We could at some point incorporate
    # a retention feature that keeps them around in case they disappear temporarily.
    # It also reads the elements if they are enabled and it's time to read them

    import pilib
    import traceback
    import RPi.GPIO as GPIO

    allowedGPIOaddresses = [18, 23, 24, 25, 4, 17, 21, 22]

    logconfig = pilib.getlogconfig()

    GPIO.setmode(GPIO.BCM)
    GPIO.setwarnings(False)

    tables = pilib.gettablenames(pilib.controldatabase)
    if 'interfaces' in tables:
        interfaces = pilib.readalldbrows(pilib.controldatabase, 'interfaces')
    else:
        pilib.writedatedlogmsg(pilib.iolog, 'interfaces table not found. Exiting', 1,
                               logconfig['iologlevel'])
        return
    if 'inputs' in tables:
        previnputs = pilib.readalldbrows(pilib.controldatabase, 'inputs')

        # Make list of IDs for easy indexing
        previnputids = []
        for input in previnputs:
            previnputids.append(input['id'])
    else:
        previnputs = []
        previnputids = []

    if 'outputs' in tables:
        prevoutputs = pilib.readalldbrows(pilib.controldatabase, 'outputs')

        # Make list of IDs for easy indexing
        prevoutputids = []
        prevoutputvalues = []
        for output in prevoutputs:
            prevoutputids.append(output['id'])
            prevoutputvalues.append(output['value'])
    else:
        prevoutputs = {}
        prevoutputids = []

    if 'defaults' in tables:
        defaults = pilib.readalldbrows(pilib.controldatabase, 'defaults')[0]
        defaultinputpollfreq = defaults['inputpollfreq']
        defaultoutputpollfreq = defaults['outputpollfreq']
    else:
        defaults = []
        defaultinputpollfreq = 60
        defaultoutputpollfreq = 60

    if 'indicators' in tables:
        indicatornames = []
        previndicators = pilib.readalldbrows(pilib.controldatabase, 'indicators')
        for indicator in previndicators:
            indicatornames.append(indicator['name'])
    else:
        previndicators = []
        indicatornames = []

    # We drop all inputs and outputs and recreate
    # Add all into one query so there is no time when the IO don't exist.

    querylist = []
    querylist.append('delete from inputs')
    querylist.append('delete from outputs')

    # This is temporary. Clearing the table here and adding entries below can result in a gap in time
    # where there are no database indicator entries. This is not too much of a problem with indicators, as we
    # update the hardware explicitly after we add the entries. If the interface queries the table during
    # this period, however, we could end up with an apparently empty table.
    # TODO: FIX update on indicators in updateio

    pilib.sqlitequery(pilib.controldatabase, 'delete from indicators')

    owfsupdate = False
    for interface in interfaces:
        if interface['interface'] == 'I2C':
            pilib.writedatedlogmsg(pilib.iolog, 'Processing I2C interface' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.writedatedlogmsg(pilib.iolog, 'I2C Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])
                if interface['type'] == 'DS2483':
                    pilib.writedatedlogmsg(pilib.iolog, 'Interface type is DS2483', 3,
                                           logconfig['iologlevel'])
                    owfsupdate = True
        elif interface['interface'] == 'USB':
            pilib.writedatedlogmsg(pilib.iolog, 'Processing USB interface' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.writedatedlogmsg(pilib.iolog, 'USB Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])
                if interface['type'] == 'DS9490':
                    pilib.writedatedlogmsg(pilib.iolog, 'Interface type is DS9490', 3,
                                           logconfig['iologlevel'])
                    owfsupdate = True
        elif interface['interface'] == 'MOTE':
            pilib.writedatedlogmsg(pilib.iolog, 'Processing Mote interface' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.writedatedlogmsg(pilib.iolog, 'Mote Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])

                # Grab mote entries from remotes table
                nodeaddress = int(interface['address'])
                nodeentries = pilib.dynamicsqliteread(pilib.controldatabase, 'remotes', condition="\"nodeid\"='" + str(nodeaddress) + "'")

                # Create queries for table insertion
                # TODO: process mote pollfreq, ontime, offtime
                moteentries = []
                for nodeentry in nodeentries:

                    datadict = pilib.parseoptions(nodeentry['data'])
                    try:
                        entrytype = nodeentry['msgtype']
                        entryid = 'MOTE' + str(nodeentry['nodeid']) + '_' + nodeentry['keyvaluename'] + '_' + nodeentry['keyvalue']


                        entrymetareturn = pilib.dynamicsqliteread(pilib.controldatabase, 'ioinfo', condition="\"id\"='" + entryid + "'")
                        try:
                            entrymeta = entrymetareturn[0]
                        except:
                            entrymeta = []

                        # print(entrymeta)

                        entryoptions={}
                        if entrymeta:
                            entryname = entrymeta['name']
                            if entrymeta['options']:
                                entryoptions = pilib.parseoptions(entrymeta['options'])
                        else:
                            entryname = '[MOTE' + str(nodeentry['nodeid']) + '] ' + nodeentry['keyvaluename'] + ':' + nodeentry['keyvalue']
                    except KeyError:
                        print('OOPS KEY ERROR')
                    else:
                        if entrytype == 'iovalue':
                            if 'scale' in entryoptions:
                                entryvalue = str(float(entryoptions['scale']) * float(datadict['iovalue']))
                            else:
                                entryvalue = datadict['iovalue']
                        elif entrytype == 'owdev':
                            if 'owtmpasc' in datadict:
                                if 'scale' in entryoptions:
                                    entryvalue = str(float(entryoptions['scale']) * float(datadict['owtmpasc']))
                                else:
                                    entryvalue = datadict['owtmpasc']
                            else:
                                entryvalue = -1
                        else:
                            entryvalue = -1

                        moteentries.append('insert into inputs values (\'' + entryid + '\',\'' + interface['interface'] + '\',\'' +
            interface['type'] + '\',\'' + str(address) + '\',\'' + entryname + '\',\'' + str(entryvalue) + "','','" +
            nodeentry['time'] + '\',\'' + str(15) + "','" + '' + "','" + '' + "')")
                # print('querylist')
                # print(moteentries)
                querylist.extend(moteentries)

        elif interface['interface'] == 'LAN':
            pilib.writedatedlogmsg(pilib.iolog, 'Processing LAN interface' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.writedatedlogmsg(pilib.iolog, 'LAN Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])
                if interface['type'] == 'MBTCP':
                    pilib.writedatedlogmsg(pilib.iolog, 'Interface ' + interface['name'] + ' type is MBTCP',
                                           3, logconfig['iologlevel'])

                    try:
                        mbentries = processMBinterface(interface, prevoutputs, prevoutputids, previnputs, previnputids, defaults, logconfig)
                    except:
                        pilib.writedatedlogmsg(pilib.iolog,
                                               'Error processing MBTCP interface ' + interface['name'], 0,
                                               logconfig['iologlevel'])
                        errorstring = traceback.format_exc()
                        pilib.writedatedlogmsg(pilib.iolog,
                                               'Error of kind: ' + errorstring, 0,
                                               logconfig['iologlevel'])
                    else:
                        pilib.writedatedlogmsg(pilib.iolog,
                                               'Done processing MBTCP interface ' + interface['name'], 3,
                                               logconfig['iologlevel'])
                        querylist.extend(mbentries)


        elif interface['interface'] == 'GPIO':
            try:
                address = int(interface['address'])
            except KeyError:
                pilib.writedatedlogmsg(pilib.iolog, 'GPIO address key not found for ' + interface['name'], 1,
                                       logconfig['iologlevel'])
                continue

            pilib.writedatedlogmsg(pilib.iolog, 'Processing GPIO interface ' + str(interface['address']), 3,
                                   logconfig['iologlevel'])

            if address in allowedGPIOaddresses:
                pilib.writedatedlogmsg(pilib.iolog, 'GPIO address' + str(address) + ' allowed', 4,
                                       logconfig['iologlevel'])

                # Check if interface is enabled
                if interface['enabled']:
                    GPIOentries = processGPIOinterface(interface, prevoutputs, prevoutputvalues, prevoutputids,
                                                       previnputs, previnputids, defaults, logconfig)
                    querylist.extend(GPIOentries)
                else:
                    pilib.writedatedlogmsg(pilib.iolog, 'GPIO address' + str(address) + ' disabled', 4,
                                           logconfig['iologlevel'])
                    GPIO.setup(address, GPIO.IN)
            else:
                pilib.writedatedlogmsg(pilib.iolog,
                                       'GPIO address' + str(address) + ' not allowed. Bad things can happen. ', 4,
                                       logconfig['iologlevel'])
        elif interface['interface'] == 'SPI0':
            pilib.writedatedlogmsg(pilib.iolog, 'Processing SPI0', 1, logconfig['iologlevel'])
            if interface['type'] == 'SPITC':
                import readspi

                spidata = readspi.readspitc(0)
                spitcentries = readspi.recordspidata(database, spidata)
                querylist.extend(spitcentries)

            if interface['type'] == 'CuPIDlights':
                import spilights

                spilightsentries, setlist = spilights.getCuPIDlightsentries('indicators', 0, previndicators)
                querylist.extend(spilightsentries)
                spilights.updatelightsfromdb(pilib.controldatabase, 'indicators', 0)
                spilights.setspilights(setlist, 0)

        elif interface['interface'] == 'SPI1':
            pilib.writedatedlogmsg(pilib.iolog, 'Processing SPI1', 1, logconfig['iologlevel'])

            if interface['type'] == 'CuPIDlights':
                import spilights

                spilightsentries, setlist = spilights.getCuPIDlightsentries('indicators', 1, previndicators)
                querylist.extend(spilightsentries)
                spilights.setspilights(setlist, 1)

    # Set tables
    querylist.append(pilib.makesinglevaluequery('systemstatus', 'lastiopoll', pilib.gettimestring()))

    if owfsupdate:
        from owfslib import runowfsupdate

        devices, owfsentries = runowfsupdate(execute=False)
        querylist.extend(owfsentries)

    pilib.writedatedlogmsg(pilib.iolog, 'Executing query:  ' + str(querylist), 5, logconfig['iologlevel'])
    try:
        pilib.sqlitemultquery(pilib.controldatabase, querylist)
    except:
        errorstring = traceback.format_exc()
        pilib.writedatedlogmsg(pilib.iolog, 'Error executing query, message:  ' + errorstring, 0, logconfig['iologlevel'])
        pilib.writedatedlogmsg(pilib.errorlog, 'Error executing updateio query, message:  ' + errorstring)
        pilib.writedatedlogmsg(pilib.errorlog, 'Query:  ' + str(querylist))
Пример #2
0
def updateiodata(database, **kwargs):
    # This recreates all input and output tables based on the interfaces table.
    # Thus way we don't keep around stale data values. We could at some point incorporate
    # a retention feature that keeps them around in case they disappear temporarily.
    # It also reads the elements if they are enabled and it's time to read them

    import pilib
    import traceback

    if 'piobject' in kwargs:
        pi = kwargs['piobject']
    else:
        import pigpio
        pi = pigpio.pi()

    allowedGPIOaddresses = [18, 23, 24, 25, 4, 17, 27, 22, 5, 6, 13, 19, 26, 16, 20, 21]

    logconfig = pilib.getlogconfig()

    tables = pilib.gettablenames(pilib.controldatabase)
    if 'interfaces' in tables:
        interfaces = pilib.readalldbrows(pilib.controldatabase, 'interfaces')
    else:
        pilib.log(pilib.iolog, 'interfaces table not found. Exiting', 1,
                               logconfig['iologlevel'])
        return
    if 'inputs' in tables:
        previnputs = pilib.readalldbrows(pilib.controldatabase, 'inputs')

        # Make list of IDs for easy indexing
        previnputids = []
        for input in previnputs:
            previnputids.append(input['id'])
    else:
        previnputs = []
        previnputids = []

    if 'outputs' in tables:
        prevoutputs = pilib.readalldbrows(pilib.controldatabase, 'outputs')

        # Make list of IDs for easy indexing
        prevoutputids = []
        prevoutputvalues = []
        for output in prevoutputs:
            prevoutputids.append(output['id'])
            prevoutputvalues.append(output['value'])
    else:
        prevoutputs = {}
        prevoutputids = []

    if 'defaults' in tables:
        defaults = pilib.readalldbrows(pilib.controldatabase, 'defaults')[0]
        defaultinputpollfreq = defaults['inputpollfreq']
        defaultoutputpollfreq = defaults['outputpollfreq']
    else:
        defaults = []
        defaultinputpollfreq = 60
        defaultoutputpollfreq = 60

    if 'indicators' in tables:
        indicatornames = []
        previndicators = pilib.readalldbrows(pilib.controldatabase, 'indicators')
        for indicator in previndicators:
            indicatornames.append(indicator['name'])
    else:
        previndicators = []
        indicatornames = []

    # We drop all inputs and outputs and recreate
    # Add all into one query so there is no time when the IO don't exist.

    querylist = []
    querylist.append('delete from inputs')
    querylist.append('delete from outputs')

    # This is temporary. Clearing the table here and adding entries below can result in a gap in time
    # where there are no database indicator entries. This is not too much of a problem with indicators, as we
    # update the hardware explicitly after we add the entries. If the interface queries the table during
    # this period, however, we could end up with an apparently empty table.
    # TODO: FIX update on indicators in updateio

    # We drop this table, so that if SP1 has been disabled, the entries do not appear as valid indicators
    pilib.sqlitequery(pilib.controldatabase, 'delete from indicators')

    owfsupdate = False
    for interface in interfaces:
        if interface['interface'] == 'I2C':
            pilib.log(pilib.iolog, 'Processing I2C interface ' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.log(pilib.iolog, 'I2C Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])
                if interface['type'] == 'DS2483':
                    pilib.log(pilib.iolog, 'Interface type is DS2483', 3,
                                           logconfig['iologlevel'])
                    owfsupdate = True
            else:
                 pilib.log(pilib.iolog, 'I2C Interface ' + interface['name'] + ' disabled', 3,
                                       logconfig['iologlevel'])
        elif interface['interface'] == 'USB':
            pilib.log(pilib.iolog, 'Processing USB interface ' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.log(pilib.iolog, 'USB Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])
                if interface['type'] == 'DS9490':
                    pilib.log(pilib.iolog, 'Interface type is DS9490', 3,
                                           logconfig['iologlevel'])
                    owfsupdate = True
            else:
                 pilib.log(pilib.iolog, 'USB Interface ' + interface['name'] + ' disabled', 3,
                                       logconfig['iologlevel'])
        elif interface['interface'] == 'MOTE':

            #determine and then update id based on fields
            entryid = interface['interface'] + '_' + interface['type'] + '_' + interface['address']
            condition = '"interface"=\'' + interface['interface'] + '\' and "type"=\'' + interface['type'] + '\' and "address"=\'' + interface['address'] + '\''

            print(condition)
            pilib.setsinglevalue(pilib.controldatabase, 'interfaces', 'id', entryid, condition)

            pilib.log(pilib.iolog, 'Processing Mote interface' + interface['name'] + ', id:' + entryid, 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.log(pilib.iolog, 'Mote Interface ' + interface['name'] + ', id:' + entryid + ' enabled', 3,
                                       logconfig['iologlevel'])

                # Grab mote entries from remotes table
                # nodeid and keyvalue are keyed into address in remotes table
                # keyvalues are :
                #   channel: channel number
                #   iovalue: ionumber
                #   owdev: ROM

                # This would look like, for example
                # 1:1 for a nodeid:channel scenario for a controller
                split = interface['address'].split(':')
                nodeid = split[0]
                keyvalue = split[1]

                # so we used to enable an interface and then take all entries from a node
                # Now, we have to explicitly add an interface for each device, unless the keychar * is used as the
                # keyvalue. This will allow us to insert all automatically, for example for owdevs or iovals from a
                # node.

                # This pulls out all mote entries that have nodeid and keyvalue that match the interface address
                # We should just find one, ideally
                if keyvalue == '*':
                    pass
                else:
                    condition = "\"nodeid\"='" + nodeid + "' and \"keyvalue\"='" + keyvalue + "'"
                    nodeentries = pilib.dynamicsqliteread(pilib.controldatabase, 'remotes', condition=condition)

                print("WE FOUND MOTE")
                print(condition)
                print(len(nodeentries))

                if interface['type'] == 'channel':
                    print('channel')
                    if len(nodeentries) == 1:
                        print('one entry found')

                        nodeentry = nodeentries[0]
                        nodedata = pilib.parseoptions(nodeentry['data'])

                        # Find existing channel so we can get existing data, settings, etc., and retain channel ordering
                        newchanneldata = {'name':interface['name'], 'controlvalue':nodedata['pv'], 'setpointvalue':nodedata['sv'],'controlvaluetime':pilib.gettimestring(), 'data':nodeentry['data'], 'type':'remote'}
                        newchannel = {}
                        existingchannels = pilib.readalldbrows(pilib.controldatabase, 'channels')
                        for channel in existingchannels:
                            if channel['name'] == interface['name']:
                                print('updating')
                                print(channel)
                                newchannel.update(channel)
                                print(newchannel)
                        newchannel.update(newchanneldata)
                        print(newchannel)

                        keys = []
                        values = []
                        for key, value in newchannel.iteritems():
                            keys.append(key)
                            values.append(value)


                        query = pilib.makesqliteinsert('channels',values, keys)
                        # print(query)
                        pilib.sqlitequery(pilib.controldatabase,query)
                    else:
                        print('multiple entries found for channel. not appropriate')
                else:
                    pass
                    # Create queries for table insertion
                    # TODO: process mote pollfreq, ontime, offtime
                    moteentries = []
                    for nodeentry in nodeentries:

                        # THis breaks out all of the strictly json-encoded data.
                        datadict = pilib.parseoptions(nodeentry['data'])
                        try:
                            entrytype = nodeentry['msgtype']

                            # now treat each mote type entry specially
                            # if entrytype == 'channel':

                            entryid = 'MOTE' + str(nodeentry['nodeid']) + '_' + nodeentry['keyvaluename'] + '_' + nodeentry['keyvalue']

                            entrymetareturn = pilib.dynamicsqliteread(pilib.controldatabase, 'ioinfo', condition="\"id\"='" + entryid + "'")
                            try:
                                entrymeta = entrymetareturn[0]
                            except:
                                entrymeta = []

                            # print(entrymeta)

                            entryoptions={}
                            if entrymeta:
                                entryname = entrymeta['name']
                                if entrymeta['options']:
                                    entryoptions = pilib.parseoptions(entrymeta['options'])
                            else:
                                entryname = '[MOTE' + str(nodeentry['nodeid']) + '] ' + nodeentry['keyvaluename'] + ':' + nodeentry['keyvalue']
                        except KeyError:
                            print('OOPS KEY ERROR')
                        else:
                            if entrytype == 'iovalue':
                                if 'scale' in entryoptions:
                                    entryvalue = str(float(entryoptions['scale']) * float(datadict['ioval']))
                                elif 'formula' in entryoptions:
                                    x = float(datadict['ioval'])
                                    try:
                                        entryvalue = eval(entryoptions['formula'])
                                    except:
                                        entryvalue = float(datadict['ioval'])
                                else:
                                    entryvalue = float(datadict['ioval'])
                            elif entrytype == 'owdev':
                                if 'owtmpasc' in datadict:
                                    if 'scale' in entryoptions:
                                        entryvalue = str(float(entryoptions['scale']) * float(datadict['owtmpasc']))
                                    elif 'formula' in entryoptions:
                                        x = float(datadict['owtmpasc'])
                                        try:
                                            entryvalue = eval(entryoptions['formula'])
                                        except:
                                            entryvalue = float(datadict['owtmpasc'])
                                    else:
                                        entryvalue = datadict['owtmpasc']
                                else:
                                    entryvalue = -1
                            else:
                                entryvalue = -1


                            moteentries.append('insert into inputs values (\'' + entryid + '\',\'' + interface['interface'] + '\',\'' +
                                interface['type'] + '\',\'' + str(address) + '\',\'' + entryname + '\',\'' + str(entryvalue) + "','','" +
                                 nodeentry['time'] + '\',\'' + str(15) + "','" + '' + "','" + '' + "')")
                    # print('querylist')
                    # print(moteentries)
                    querylist.extend(moteentries)

            else:
                pilib.log(pilib.iolog, 'Mote Interface ' + interface['name'] + ' disnabled', 3,
                                       logconfig['iologlevel'])
        elif interface['interface'] == 'LAN':
            pilib.log(pilib.iolog, 'Processing LAN interface' + interface['name'], 3,
                                   logconfig['iologlevel'])
            if interface['enabled']:
                pilib.log(pilib.iolog, 'LAN Interface ' + interface['name'] + ' enabled', 3,
                                       logconfig['iologlevel'])
                if interface['type'] == 'MBTCP':
                    pilib.log(pilib.iolog, 'Interface ' + interface['name'] + ' type is MBTCP',
                                           3, logconfig['iologlevel'])

                    try:
                        mbentries = processMBinterface(interface, prevoutputs, prevoutputids, previnputs, previnputids, defaults, logconfig)
                    except:
                        pilib.log(pilib.iolog,
                                               'Error processing MBTCP interface ' + interface['name'], 0,
                                               logconfig['iologlevel'])
                        errorstring = traceback.format_exc()
                        pilib.log(pilib.iolog,
                                               'Error of kind: ' + errorstring, 0,
                                               logconfig['iologlevel'])
                    else:
                        pilib.log(pilib.iolog,
                                               'Done processing MBTCP interface ' + interface['name'], 3,
                                               logconfig['iologlevel'])
                        querylist.extend(mbentries)
            else:
                pilib.log(pilib.iolog, 'LAN Interface ' + interface['name'] + ' disabled', 3,
                                       logconfig['iologlevel'])
        elif interface['interface'] == 'GPIO':
            try:
                address = int(interface['address'])
            except KeyError:
                pilib.log(pilib.iolog, 'GPIO address key not found for ' + interface['name'], 1,
                                       logconfig['iologlevel'])
                continue
            if interface['enabled']:

                pilib.log(pilib.iolog, 'Processing GPIO interface ' + str(interface['address']), 3,
                                       logconfig['iologlevel'])

                if address in allowedGPIOaddresses:
                    pilib.log(pilib.iolog, 'GPIO address' + str(address) + ' allowed. Processing.', 4,
                                           logconfig['iologlevel'])
                    GPIOentries = processGPIOinterface(interface, prevoutputs, prevoutputvalues, prevoutputids,
                                                               previnputs, previnputids, defaults, logconfig, piobject=pi)
                    if GPIOentries:
                                querylist.extend(GPIOentries)
                else:
                    pilib.log(pilib.iolog,
                                           'GPIO address' + str(address) + ' not allowed. Bad things can happen. ', 4,
                                           logconfig['iologlevel'])

            else:
                pilib.log(pilib.iolog, 'GPIO address' + str(address) + ' disabled. Doing nothing.', 4,
                                               logconfig['iologlevel'])
        elif interface['interface'] == 'SPI0':
            pilib.log(pilib.iolog, 'Processing SPI0', 1, logconfig['iologlevel'])
            if interface['enabled']:
                pilib.log(pilib.iolog, 'SPI0 enabled', 1, logconfig['iologlevel'])
                if interface['type'] == 'SPITC':
                    pilib.log(pilib.iolog, 'Processing SPITC on SPI0', 3, logconfig['iologlevel'])
                    import readspi

                    tcdict = readspi.getpigpioMAX31855temp(0,0)

                    # Convert to F for now
                    spitcentries = readspi.recordspidata(database, {'SPITC1' :tcdict['tctemp']*1.8+32})
                    querylist.extend(spitcentries)

                if interface['type'] == 'CuPIDlights':
                    import spilights

                    spilightsentries, setlist = spilights.getCuPIDlightsentries('indicators', 0, previndicators)
                    querylist.extend(spilightsentries)
                    spilights.updatelightsfromdb(pilib.controldatabase, 'indicators', 0)
                    spilights.setspilights(setlist, 0)
            else:
                pilib.log(pilib.iolog, 'SPI0 not enabled', 1, logconfig['iologlevel'])

        elif interface['interface'] == 'SPI1':
            pilib.log(pilib.iolog, 'Processing SPI1', 1, logconfig['iologlevel'])
            if interface['enabled']:
                pilib.log(pilib.iolog, 'SPI1 enabled', 1, logconfig['iologlevel'])
                if interface['type'] == 'CuPIDlights':
                    pilib.log(pilib.iolog, 'Processing CuPID Lights on SPI1', 1, logconfig['iologlevel'])
                    import spilights

                    spilightsentries, setlist = spilights.getCuPIDlightsentries('indicators', 1, previndicators)
                    querylist.extend(spilightsentries)
                    spilights.setspilights(setlist, 1)
            else:
                pilib.log(pilib.iolog, 'SPI1 disaabled', 1, logconfig['iologlevel'])

    # Set tables
    querylist.append(pilib.makesinglevaluequery('systemstatus', 'lastiopoll', pilib.gettimestring()))

    if owfsupdate:
        from owfslib import runowfsupdate
        pilib.log(pilib.iolog, 'Running owfsupdate', 1, logconfig['iologlevel'])
        devices, owfsentries = runowfsupdate(execute=False)
        querylist.extend(owfsentries)
    else:
        pilib.log(pilib.iolog, 'owfsupdate disabled', 3, logconfig['iologlevel'])

    pilib.log(pilib.iolog, 'Executing query:  ' + str(querylist), 5, logconfig['iologlevel'])
    try:
        # print(querylist)
        pilib.sqlitemultquery(pilib.controldatabase, querylist)
    except:
        errorstring = traceback.format_exc()
        pilib.log(pilib.iolog, 'Error executing query, message:  ' + errorstring, 0, logconfig['iologlevel'])
        pilib.log(pilib.errorlog, 'Error executing updateio query, message:  ' + errorstring)
        pilib.log(pilib.errorlog, 'Query:  ' + str(querylist))
Пример #3
0
def updateiodata(database):
    # This recreates all input and output tables based on the interfaces table.
    # Thus way we don't keep around stale data values. We could at some point incorporate
    # a retention feature that keeps them around in case they disappear temporarily.
    # It also reads the elements if they are enabled and it's time to read them

    import pilib
    import RPi.GPIO as GPIO

    allowedGPIOaddresses = [18, 23, 24, 25, 4, 17, 21, 22]

    dontrun = False
    GPIO.setmode(GPIO.BCM)
    GPIO.setwarnings(False)

    tables = pilib.gettablenames(pilib.controldatabase)
    if 'interfaces' in tables:
        interfaces = pilib.readalldbrows(pilib.controldatabase, 'interfaces')
    else:
        print('interfaces table not found. Exiting')
        return
    if 'inputs' in tables:
        previnputs = pilib.readalldbrows(pilib.controldatabase, 'inputs')

        # Make list of IDs for easy indexing
        previnputids = []
        for input in previnputs:
            previnputids.append(input['id'])
    else:
        previnputs = []
        previnputids = []

    if 'outputs' in tables:
        prevoutputs = pilib.readalldbrows(pilib.controldatabase, 'outputs')

        # Make list of IDs for easy indexing
        prevoutputids = []
        prevoutputvalues = []
        for output in prevoutputs:
            prevoutputids.append(output['id'])
            prevoutputvalues.append(output['value'])
    else:
        prevoutputs = {}
        prevoutputids = []

    if 'defaults' in tables:
        defaults = pilib.readalldbrows(pilib.controldatabase, 'defaults')[0]
        defaultinputpollfreq = defaults['inputpollfreq']
        defaultoutputpollfreq = defaults['outputpollfreq']
    else:
        defaults = []
        defaultinputpollfreq = 60
        defaultoutputpollfreq = 60

    # We drop all inputs and outputs and recreate
    # Add all into one query so there is no time when the IO don't exist.

    querylist = []
    querylist.append('delete from inputs')
    querylist.append('delete from outputs')
    pilib.sqlitemultquery(pilib.controldatabase, querylist)

    querylist = []
    for interface in interfaces:
        if interface['interface'] == 'I2C':
            if interface['enabled']:
                # print('processing enabled I2C')
                if interface['type'] == 'DS2483':
                    from owfslib import runowfsupdate
                    runowfsupdate()


        elif interface['interface'] == 'GPIO':

            options = pilib.parseoptions(interface['options'])

            # TODO : respond to more option, like pullup and pulldown

            address = int(interface['address'])

            if address in allowedGPIOaddresses:

                # Check if interface is enabled

                if interface['enabled']:

                    # Get name from ioinfo table to give it a colloquial name
                    gpioname = pilib.sqlitedatumquery(database, 'select name from ioinfo where id=\'' +
                                                                interface['id'] + '\'')
                    polltime = pilib.gettimestring()

                    # Append to inputs and update name, even if it's an output (can read status as input)

                    if options['mode'] == 'output':
                        GPIO.setup(address, GPIO.OUT)

                        # Set the value of the gpio.
                        # Get previous value if exists
                        if interface['id'] in prevoutputids:
                            value = prevoutputvalues[prevoutputids.index(interface['id'])]
                        else:
                            value = 0
                        if value == 1:
                            GPIO.output(address, True)
                        else:
                            GPIO.output(address, False)

                        # Get output settings and keep them if the GPIO previously existed
                        if interface['id'] in prevoutputids:
                            pollfreq = prevoutputs[prevoutputids.index(interface['id'])]['pollfreq']
                        else:
                            pollfreq = defaultoutputpollfreq

                        # Add entry to outputs tables
                        querylist.append('insert into outputs values (\'' + interface['id'] + '\',\'' +
                            interface['interface'] + '\',\'' + interface['type'] + '\',\'' + str(address) + '\',\'' +
                                         gpioname + '\',\'' + str(value) + '\',\'\',\'' + str(polltime) + '\',\'' +
                                         str(pollfreq) + '\')')
                    else:
                        GPIO.setup(address, GPIO.IN)
                        value = GPIO.input(address)
                        polltime = pilib.gettimestring()

                    # Get input settings and keep them if the GPIO previously existed
                    if interface['id'] in prevoutputids:
                        pollfreq = previnputs[prevoutputids.index(interface['id'])]['pollfreq']
                        polltime = previnputs[prevoutputids.index(interface['id'])]['polltime']
                    else:
                        pollfreq = defaultinputpollfreq


                    # Add entry to inputs tables
                    # Get output settings and keep them if the GPIO previously existed
                    if interface['id'] in prevoutputids:
                        pollfreq = prevoutputs[prevoutputids.index(interface['id'])]['pollfreq']
                    else:
                        pollfreq = defaultoutputpollfreq
                    querylist.append(
                        'insert into inputs values (\'' + interface['id'] + '\',\'' + interface['interface'] + '\',\'' +
                        interface['type'] + '\',\'' + str(address) + '\',\'' + gpioname + '\',\'' + str(value) + '\',\'\',\'' +
                        str(polltime) + '\',\'' + str(pollfreq) + '\')')

                else:
                    GPIO.setup(address, GPIO.IN)
            else:
                print('GPIO address ' + address + 'not allowed. BAD THINGS CAN HAPPEN.')

        elif interface['interface'] == 'SPI':
            # print('processing SPI')
            if interface['type'] == 'SPITC':
                import readspi

                spidata = readspi.readspitc()
                readspi.recordspidata(database, spidata)
            elif interface['type'] == 'CuPIDLights':
                import spilights

                spilights.updatelightsfromdb(pilib.controldatabase, 'indicators')

    # Set tables