Пример #1
0
def testPubSubStaticConf():

    logger = TapLogger("pubsub_server_test.tap")
    pubsubserver = PubSubServer(DEFAULT_URI, NID_CONFIGURATION, NID_START_STOP, NID_STATUS)

    defaultXml2Restore = False

    try:
        # secure channel connection
        pubsubserver.connect()

        #
        # TC 1 : Test with Static Publisher and Subscriber configuration => subscriber variables change through Pub/Sub
        #
        logger.begin_section("TC 1 : Subscriber variables change through Pub/Sub")

        # Set Publisher variables and test change in Subscriber variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT, 8500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger)

        sleep(STATIC_CONF_PUB_INTERVAL)

        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT))
        logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT))


        # Set Publisher variables and test change in Subscriber variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT, 5800, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -30, logger)

        sleep(STATIC_CONF_PUB_INTERVAL)

        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint is changed ', 5800 == pubsubserver.getValue(NID_SUB_UINT))
        logger.add_test('Subscriber int is changed ', -30 == pubsubserver.getValue(NID_SUB_INT))


        #
        # TC 2 : Pub-Sub server is stopped => no change in Subscriber variables
        #
        logger.begin_section("TC 2 : Pub-Sub server is stopped")

        pubsubserver.stop()
        logger.add_test('PubSub Module is stopped' , not pubsubserver.isStart())

        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT, 7777, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, 123654, logger)

        sleep(STATIC_CONF_PUB_INTERVAL)

        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint is changed ', 5800 == pubsubserver.getValue(NID_SUB_UINT))
        logger.add_test('Subscriber int is changed ', -30 == pubsubserver.getValue(NID_SUB_INT))

        #
        # TC 3 : Pub-Sub server is restarted => Subscriber variables changed
        #
        logger.begin_section("TC 3 : Pub-Sub server is restarted")

        pubsubserver.start()
        logger.add_test('PubSub Module is started' , pubsubserver.isStart())

        sleep(STATIC_CONF_PUB_INTERVAL)

        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint is changed ', 7777 == pubsubserver.getValue(NID_SUB_UINT))
        logger.add_test('Subscriber int is changed ', 123654 == pubsubserver.getValue(NID_SUB_INT))

        #
        # TC 4 : Change Pub-Sub server configuration => configuration cannot be changed in static mode
        #
        logger.begin_section("TC 4 : Change Pub-Sub server configuration")
        # Change Pub-Sub configuration node and check file is not change
        helpConfigurationChangeAndStart(pubsubserver, XML_SUBSCRIBER_ONLY, logger, static=True)

        # Check Pub-Sub module is still running
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT, 1245, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, 9874, logger)

        sleep(STATIC_CONF_PUB_INTERVAL)

        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint is changed ', 1245 == pubsubserver.getValue(NID_SUB_UINT))
        logger.add_test('Subscriber int is changed ', 9874 == pubsubserver.getValue(NID_SUB_INT))

    finally:
        pubsubserver.disconnect()
        logger.add_test('Not connected to OPCUA Server', not pubsubserver.isConnected())
        logger.finalize_report()
Пример #2
0
def testPubSubDynamicConf():

    logger = TapLogger("pubsub_server_test.tap")
    pubsubserver = PubSubServer(DEFAULT_URI, NID_CONFIGURATION, NID_START_STOP, NID_STATUS)

    defaultXml2Restore = False

    try:
        # backup of default XML file
        copyfile(DEFAULT_XML_PATH, DEFAULT_XML_PATH + ".bakup")
        defaultXml2Restore = True

        # secure channel connection
        pubsubserver.connect()

        #
        # TC 1 : Test with Publisher only configuration => only pub variables change
        #
        logger.begin_section("TC 1 : Publisher only")
        helpConfigurationChangeAndStart(pubsubserver, XML_PUBLISHER_ONLY, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        # Set Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 1500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -50, logger)
        sleep(DYN_CONF_PUB_INTERVAL_1000)
        logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 2 : Test with Subscriber only configuration => no variables change
        #
        logger.begin_section("TC 2 : Subscriber only")

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        helpConfigurationChangeAndStart(pubsubserver, XML_SUBSCRIBER_ONLY, logger)
        sleep(DYN_CONF_PUB_INTERVAL_1000)
        logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 3 : Test with Publisher and Subscriber configuration => subscriber variables change through Pub/Sub
        #
        logger.begin_section("TC 3 : Publisher Subscriber Loop")

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP, logger)
        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -50 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 4 : Stop Pub/Sub module => subscriber variables do not change
        #
        logger.begin_section("TC 4 : Publisher Subscriber Loop")

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', -50 == pubsubserver.getValue(NID_SUB_INT))

        # Start to change Subscriber variables
        pubsubserver.start()
        helpTestStopStart(pubsubserver, True, logger)
        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 6500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -600 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 5 : Test with Publisher and Subscriber configuration. DataType is NULL
        #        => subscriber variables change through Pub/Sub
        #
        logger.begin_section("TC 5 : Publisher Subscriber Loop (DataType is Null)")

        # Init Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 8500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_NULL, logger)
        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 6 : Test with Publisher and Subscriber configuration => subscriber variables change through Pub/Sub
        #
        logger.begin_section("TC 6 : Test with Publisher and Subscriber configuration (MQTT) => subscriber variables change through Pub/Sub")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_MQTT, logger)
        sleep(DYN_CONF_PUB_INTERVAL_1000)

        # Init Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 8500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger)
        helpTestSetValue(pubsubserver, NID_PUB_STRING, "Test MQTT From Publisher", logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)
        helpTestSetValue(pubsubserver, NID_SUB_STRING, "Test MQTT Not set", logger)

        sleep(DYN_CONF_PUB_INTERVAL_1000)

        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT))
        logger.add_test('Subscriber string is changed ', "Test MQTT From Publisher" == pubsubserver.getValue(NID_SUB_STRING))
        sleep(DYN_CONF_PUB_INTERVAL_1000)

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)


        #
        # TC 7 : Test with configuration message not consistent between the one on Publisher
        #        and the one on Subscriber  => subscriber variables do not change
        #
        logger.begin_section("TC 7 : Publisher Subscriber not consistent")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_MESSAGE_NOT_COMPATIBLE, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT))

        #
        # TC 8 : Test with a bad formed configuration => Pub/Sub status is 0
        #
        logger.begin_section("TC 8 : Bad formed configuration")
        helpConfigurationChange(pubsubserver, XML_PUBSUB_BAD_FORMED_CONFIGURATION, logger)

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        logger.add_test('Start Server', True)
        pubsubserver.start()
        status = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status)

        #
        # TC 9 : Start and Stop empty configuration
        #
        logger.begin_section("TC 9 : Empty configuration")
        helpConfigurationChange(pubsubserver, XML_EMPTY, logger)
        status = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status)


        #
        # TC 10 : Test with message configured with security mode encrypt and sign for publisher
        #         but no security for subscriber => subscriber variables do not change
        #
        logger.begin_section("TC 10 : Security mode not consistent - message is encrypt and sign but no security for subscriber")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_FAIL_1, logger, possibleFail=True)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT))

        expStatus = 3 # Error state
        retrievedStatus = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus)


        #
        # TC 11 : Test with message configured with security mode encrypt and sign for publisher
        #         but only sign for subscriber => subscriber variables do not change
        #
        logger.begin_section("TC 11 : Security mode not consistent - message is encrypt and sign but only sign mode for subscriber")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_FAIL_2, logger, possibleFail=True)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT))

        expStatus = 3 # Error state
        retrievedStatus = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus)

        #
        # TC 12 : Test with message configured with security mode sign for publisher
        #         but encrypt and sign for subscriber => subscriber variables do not change
        #
        logger.begin_section("TC 12 : Security mode not consistent - message is sign but sign and encrypt for subscriber")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_FAIL_3, logger, possibleFail=True)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT))

        expStatus = 3 # Error state
        retrievedStatus = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus)

        #
        # TC 13 : Test with message configured with security mode sign and encrypt
        #         for both publisher and subscriber => subscriber variables change
        #
        logger.begin_section("TC 13 : Security mode sign and encrypt")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_ENCRYPT_SIGN_SUCCEED, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 852, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, 2658, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 852 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', 2658 == pubsubserver.getValue(NID_SUB_INT))

        #
        # TC 14 : Test with message configured with security mode sign
        #         for both publisher and subscriber => subscriber variables change
        #
        logger.begin_section("TC 14 : Security mode sign")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_SIGN_SUCCEED, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 528, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, 7896, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 528 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', 7896 == pubsubserver.getValue(NID_SUB_INT))

        #
        # TC 15 : Test with message configured with security mode sign only
        #         for publisher => subscriber variables do not change
        #
        logger.begin_section("TC 15 : Security mode sign only publisher")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_SECU_SIGN_FAIL_4, logger, possibleFail=True)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 1456, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 123654, logger)

        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 456, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, 789, logger)

        sleep(DYN_CONF_PUB_INTERVAL_200)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 1456 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 123654 == pubsubserver.getValue(NID_SUB_INT))

        expStatus = 3 # Error state
        retrievedStatus = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be %d : %d' % (expStatus, retrievedStatus) , expStatus == retrievedStatus)

    finally:
        # restore default XML file
        if defaultXml2Restore:
            move(DEFAULT_XML_PATH + ".bakup", DEFAULT_XML_PATH)

        pubsubserver.disconnect()
        logger.add_test('Not connected to OPCUA Server', not pubsubserver.isConnected())
        logger.finalize_report()
Пример #3
0
from view_basic import browse_tests
from translate_browse_path import translate_browse_paths_to_node_ids_tests
from common import sUri, create_client
from tap_logger import TapLogger
from opcua.crypto import security_policies

if __name__ == '__main__':

    # tests with one connexion
    print('Connecting to', sUri)
    client = create_client()
    logger = TapLogger("validation.tap")
    headerString = "******************* Beginning {0} tests with one connexion *********************"
    for sp in [SecurityPolicy, security_policies.SecurityPolicyBasic256]:
        #for sp in [SecurityPolicy]:
        logger.begin_section("security policy {0}".format(
            re.split("#", sp.URI)[-1]))
        try:
            # secure channel connection
            secure_channels_connect(client, sp)

            # discovery server services
            discovery_server_tests(client, logger)

            # check endpoints
            discovery_get_endpoints_tests(client, logger)

            # Read tests
            print(headerString.format("Read"))
            attribute_read_tests(client, logger)

            # Force renew secure channel (nominal case)
Пример #4
0
        ## remove keep alive
        # END MODIFICATION
        return response


if __name__=='__main__':
    # Tests with one connexion
    print('Connecting to', sUri)
    client = Client2(sUri)
    logger = TapLogger("session_timeout.tap")
    headerString = "******************* {0} *********************"

    # Test revised session timeout
    for l_session_timeout in [5000, 360000, 45000000]:
        try:
            logger.begin_section("Requested session timeout {0}".format(l_session_timeout))
            client.session_timeout = l_session_timeout
            # secure channel connection
            print(headerString.format("SC connection and session establishment with requested timeout {0}"
                                     .format(l_session_timeout)))
            secure_channels_connect(client, SecurityPolicy)
            print(headerString.format("Check revised session timeout value"))
            if (l_session_timeout < MIN_SESSION_TIMEOUT
                and client.session_timeout == MIN_SESSION_TIMEOUT):
                logger.add_test("- Revised timeout set to min value {}".format(client.session_timeout), True)
            elif (l_session_timeout > MAX_SESSION_TIMEOUT
                  and client.session_timeout == MAX_SESSION_TIMEOUT):
                logger.add_test("- Revised timeout set to max value {}".format(client.session_timeout), True)
            elif (l_session_timeout >= MIN_SESSION_TIMEOUT
                  and l_session_timeout <= MAX_SESSION_TIMEOUT
                  and client.session_timeout == l_session_timeout):
Пример #5
0
def testPubSubDynamicConf():

    logger = TapLogger("pubsub_server_test.tap")
    pubsubserver = PubSubServer(DEFAULT_URI, NID_CONFIGURATION, NID_START_STOP, NID_STATUS)

    defaultXml2Restore = False
    
    try:
        # backup of default XML file
        copyfile(DEFAULT_XML_PATH, DEFAULT_XML_PATH + ".bakup")
        defaultXml2Restore = True

        # secure channel connection
        pubsubserver.connect()

        #
        # TC 1 : Test with Publisher only configuration => only pub variables change
        #
        logger.begin_section("TC 1 : Publisher only")
        helpConfigurationChangeAndStart(pubsubserver, XML_PUBLISHER_ONLY, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        # Set Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 1500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -50, logger)
        sleep(.400)
        logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 2 : Test with Subscriber only configuration => no variables change
        #
        logger.begin_section("TC 2 : Subscriber only")
        
        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        helpConfigurationChangeAndStart(pubsubserver, XML_SUBSCRIBER_ONLY, logger)
        sleep(.400)
        logger.add_test('Subscriber bool is not changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 3 : Test with Publisher and Subscriber configuration => subscriber variables change through Pub/Sub
        #
        logger.begin_section("TC 3 : Publisher Subscriber Loop")

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP, logger)
        sleep(.400)
        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -50 == pubsubserver.getValue(NID_SUB_INT))

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 4 : Stop Pub/Sub module => subscriber variables do not change
        #
        logger.begin_section("TC 4 : Publisher Subscriber Loop")
        
        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)
        
        sleep(.400)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 1500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', -50 == pubsubserver.getValue(NID_SUB_INT))

        # Start to change Subscriber variables
        pubsubserver.start()
        helpTestStopStart(pubsubserver, True, logger)
        sleep(.400)
        logger.add_test('Subscriber bool is changed ', True == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 6500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -600 == pubsubserver.getValue(NID_SUB_INT))
        
        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        #
        # TC 5 : Test with Publisher and Subscriber configuration. DataType is NULL
        #        => subscriber variables change through Pub/Sub
        #
        logger.begin_section("TC 5 : Publisher Subscriber Loop (DataType is Null)")

        # Init Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 8500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -300, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_NULL, logger)
        sleep(.400)
        logger.add_test('Subscriber bool is changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is changed ', 8500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is changed ', -300 == pubsubserver.getValue(NID_SUB_INT))
     
        #
        # TC 6 : Test with configuration message not consistent between the one on Publisher
        #        and the one on Subscriber  => subscriber variables do not change
        #
        logger.begin_section("TC 6 : Publisher Subscriber not consistent")

        helpConfigurationChangeAndStart(pubsubserver, XML_PUBSUB_LOOP_MESSAGE_NOT_COMPATIBLE, logger)

        # Init Subscriber variables
        helpTestSetValue(pubsubserver, NID_SUB_BOOL, False, logger)
        helpTestSetValue(pubsubserver, NID_SUB_UINT16, 500, logger)
        helpTestSetValue(pubsubserver, NID_SUB_INT, 100, logger)
        
        # Change Publisher variables
        helpTestSetValue(pubsubserver, NID_PUB_BOOL, True, logger)
        helpTestSetValue(pubsubserver, NID_PUB_UINT16, 6500, logger)
        helpTestSetValue(pubsubserver, NID_PUB_INT, -600, logger)
        
        sleep(.400)
        logger.add_test('Subscriber bool is not changed ', False == pubsubserver.getValue(NID_SUB_BOOL))
        logger.add_test('Subscriber uint16 is not changed ', 500 == pubsubserver.getValue(NID_SUB_UINT16))
        logger.add_test('Subscriber int is not changed ', 100 == pubsubserver.getValue(NID_SUB_INT))

        #
        # TC 7 : Test with a bad formed configuration => Pub/Sub status is 0
        #
        logger.begin_section("TC 7 : Bad formed configuration")
        helpConfigurationChange(pubsubserver, XML_PUBSUB_BAD_FORMED_CONFIGURATION, logger)

        pubsubserver.stop()
        helpTestStopStart(pubsubserver, False, logger)

        logger.add_test('Start Server', True)
        pubsubserver.start()
        status = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status)
       
        #
        # TC 8 : Start and Stop empty configuration
        #
        logger.begin_section("TC 8 : Empty configuration")
        helpConfigurationChange(pubsubserver, XML_EMPTY, logger)
        status = pubsubserver.getStatus()
        logger.add_test('PubSub Module Status should be 0 : %d' % status , 0 == status)

    finally:
        # restore default XML file
        if defaultXml2Restore:
            move(DEFAULT_XML_PATH + ".bakup", DEFAULT_XML_PATH)

        pubsubserver.disconnect()
        logger.add_test('Not connected to OPCUA Server', not pubsubserver.isConnected())
        logger.finalize_report()
Пример #6
0
                print('Read Tests')
                connection.test_read()
                print('Write Tests')
                connection.test_write()
                print('Browse Tests')
                connection.test_browse()

        # Do the read/write with multiple connections
        print('Asynch Write/Reads on new connections')
        connections = [PyS2OPC.connect(cfg, ConnectionHandler) for cfg in configs]
        for conn in connections:
            conn.set_logger(logger_)
            conn.configure_subscription()
        try:
            # Do the write on one connection, reads on all others to assert the result.
            logger_.begin_section('ReadWrite Tests -')
            connA, *conns = connections
            connA.test_write_and_assert()
            for conn in conns:
                conn._test_read(readInitValues = False, onlyValues = True)
            connA.test_write_and_assert(resetInitValues = True)
            # Wait for subscriptions to end. Does not wait more than the publish cycle,
            #  as the last notifications should be received by then.
            timeout = .001*max(cfg.parameters.get('publish_period_ms', 0.) for cfg in configs)
            for conn in connections:
                assert conn.subscriptionComplete.wait(timeout)
            logger_.add_test('Values all correctly notified', True)
        finally:
            for conn in connections:
                conn.disconnect()