Пример #1
0
def get_system_log (system):
    system = int (system)
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_blade_state,
        device_id = system)
    
    result = {"ID" : system}
    return view_helper.return_redfish_resource ("system_log", values = result)
Пример #2
0
def get_system_bios_config (system, patch = dict ()):
    system = int (system)
    if (not patch):
        view_helper.run_pre_check (pre_check.pre_check_function_call,
            command_name_enum.get_blade_state, device_id = system)
    
    query = [
        (controls.bladebios_lib.get_server_bios_config, {"serverid" : system})
    ]
    
    result = execute_get_request_queries (query, {"ID" : system})
    
    configs = []
    if ("AvailableConfigName" in result):
        configs.append ({"Config_Name" : result["AvailableConfigName"]})
    else:
        config_list = result.get ("AvailableConfigurations", {})
        if (config_list):
            i = 1
            while i in config_list:
                configs.append (config_list[i])
                i += 1
    result["AvailableConfigs"] = configs
    
    view_helper.update_and_replace_status_information (result, patch)
    return view_helper.return_redfish_resource ("system_bios_cfg", values = result)
Пример #3
0
def get_system_thermal (system):
    system = int (system)
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_blade_state,
        device_id = system)
    
    query_temp = [
        (controls.server_health.show_temperature_health, {"serverid" : system})
    ]
    query_fan = [
        (controls.server_health.show_fan_health, {"serverid" : system})
    ]
    
    result_temp = execute_get_request_queries (query_temp)
    result_fan = execute_get_request_queries (query_fan)
    
    temps = parse_sensor_list (sensors = result_temp, convert_reading = True, convert_number = True,
        sensor_type = "Sensor")
    fans = parse_sensor_list (sensors = result_fan, convert_reading = True, convert_number = False,
        sensor_type = "Fan")
    
    result = {}
    view_helper.append_response_information (result, result_temp)
    view_helper.append_response_information (result, result_fan)
    
    if (temps):
        result["temps"] = temps
    if (fans):
        result["fans"] = fans
    result["ID"] = system
    
    return view_helper.return_redfish_resource ("system_thermal", values = result)
Пример #4
0
def get_pmdu_power_meter (patch = dict ()):
    if (not patch):
        view_helper.run_pre_check (pre_check.pre_check_function_call,
            command_name_enum.get_rm_state)
    
    query = [
        (controls.manage_powermeter.get_rack_power_limit_policy, {}),
        (controls.manage_powermeter.get_rack_power_throttle_status, {}),
        (controls.manage_powermeter.get_rack_power_reading, {}),
        (controls.manage_powermeter.get_rack_pru_fw_version, {})
    ]
    result = execute_get_request_queries (query)
    
    if ("Feed1PowerStatus" in result):
        if (result["Feed1PowerStatus"] == "Healthy"):
            result["Feed1PowerStatus"] = ""
    if ("Feed2PowerStatus" in result):
        if (result["Feed2PowerStatus"] == "Healthy"):
            result["Feed2PowerStatus"] = ""
    if ("IsDcThrottleEnabled" in result):
        result["IsDcThrottleEnabled"] = enums.Boolean (result["IsDcThrottleEnabled"],
            convert = True)
    if ("IsDcThrottleActive" in result):
        result["IsDcThrottleActive"] = enums.Boolean (result["IsDcThrottleActive"], convert = True)
    if ("IsAlertEnabled" in result):
        result["IsAlertEnabled"] = enums.Boolean (result["IsAlertEnabled"], convert = True)
    if ("IsAlertActive" in result):
        result["IsAlertActive"] = enums.Boolean (result["IsAlertActive"], convert = True)
    
    view_helper.update_and_replace_status_information (result, patch)
    return view_helper.return_redfish_resource ("pmdu_power_meter", values = result)
Пример #5
0
def get_rack_inventory ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (controls.bladeinfo_lib.manager_inventory, {"mode" : "pmdu"})
    ]
    
    result = execute_get_request_queries (query)
    
    parsed = [None] * len (result)
    if (result[completion_code.cc_key] == completion_code.success):
        for i, item in result.items ():
            try:
                idx = int (i) - 1
                if ("Port_Present" in item):
                    item["Port_Present"] = enums.Boolean (item["Port_Present"], convert = True)
                    
                if ("Port_State" in item):
                    item["Port_State"] = enums.PowerState (item["Port_State"], convert = True)
                            
                parsed[idx] = item
                del result[i]
                
            except ValueError:
                pass
            
    parsed = filter (None, parsed)
    if (parsed):
        result["list"] = parsed
        
    return view_helper.return_redfish_resource ("rack_inventory", values = result)
Пример #6
0
def patch_pmdu_power_meter():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_state)

    throttle_args = {}
    actions = {
        "DatacenterThrottleEnabled":
        (apply_power_throttle, parameter_parser("dcpolicy", int,
                                                enums.Boolean), {
                                                    "args": throttle_args
                                                }),
        "AlertEnabled": (apply_power_throttle,
                         parameter_parser("policy", int, enums.Boolean), {
                             "args": throttle_args
                         }),
        "AlertLimitWatts":
        (controls.manage_powermeter.set_rack_power_limit_policy,
         parameter_parser("powerlimit", float), {})
    }

    result = validate_patch_request_and_execute(actions, "pmdu_power_meter")
    throttle = apply_power_throttle(force_set=True, args=throttle_args)
    view_helper.append_response_information(result, throttle)

    return get_handler.get_pmdu_power_meter(patch=result)
Пример #7
0
def post_system_reset(system):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_state,
                              device_id=system)

    validation = {
        "ResetType":
        parameter_parser(
            "type", str, ResetType, {
                "valid": [
                    ResetType.ON, ResetType.GRACEFUL_SHUTDOWN,
                    ResetType.GRACEFUL_RESTART
                ]
            })
    }
    params = validate_action_parameters(validation)

    if (params["type"] == ResetType.ON):
        result = controls.bladepowerstate_lib.set_server_on(system)
    elif (params["type"] == ResetType.GRACEFUL_SHUTDOWN):
        result = controls.bladepowerstate_lib.set_server_off(system)
    else:
        result = controls.bladepowerstate_lib.set_server_active_power_cycle(
            system)

    return check_action_result(result)
Пример #8
0
def post_system_remotemedia_unmount(system):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_state,
                              device_id=system)

    result = controls.manage_rmedia.umount_rmedia(system)
    return check_action_result(result)
Пример #9
0
def post_system_power_deactivate_limit(system):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_config,
                              device_id=system)

    result = controls.manage_ocspower.set_server_power_limit_off(system)
    return check_action_result(result)
Пример #10
0
def post_system_manager_clear_log(system):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_state,
                              device_id=system)

    result = controls.bladelog_lib.clear_server_log(system, raw_output=False)
    return check_action_result(result)
Пример #11
0
def post_system_phase_clear_faults(system, phase):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_state,
                              device_id=system)

    result = controls.manage_ocspower.clear_server_psu_faults(system, phase)
    return check_action_result(result)
Пример #12
0
def post_rack_manager_fw_update():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_config)

    validation = {"File": parameter_parser("filename", str)}
    params = validate_action_parameters(validation)

    result = controls.manage_rack_manager.set_rack_manager_fwupdate(**params)
    return check_action_result(result)
Пример #13
0
def get_rack_manager_tftp ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (controls.manage_rack_manager.manager_tftp_server_listfiles, {})
    ]
    result = execute_get_request_queries (query)
    
    return view_helper.return_redfish_resource ("rack_manager_tftp", values = result)
Пример #14
0
def get_rack_manager_thermal ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (controls.manage_rack_manager.get_sensor_objects, {})
    ]
    result = execute_get_request_queries (query)
    
    return view_helper.return_redfish_resource ("rack_manager_thermal", values = result)
Пример #15
0
def get_accounts ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (controls.manage_user.user_list_all, {})
    ]
    
    result = execute_get_request_queries (query)
    
    return view_helper.return_redfish_resource ("accounts", values = result)
Пример #16
0
def get_switch_chassis ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (models.switch_manager.getswitch (load_config.switch_ip, "").getswitch_info, {})
    ]
    
    result = execute_get_request_queries (query)
    
    return view_helper.return_redfish_resource ("switch_chassis", values = result)
Пример #17
0
def get_rack_manager_ethernets ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (controls.manage_network.display_cli_interfaces, {})
    ]
    
    result = execute_get_request_queries (query)
        
    return view_helper.return_redfish_resource ("rack_manager_ethernets", values = result)
Пример #18
0
def get_rack_chassis ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)

    query = [
        (controls.manage_rack_manager.read_fru, {"boardtype" : "rm_mb"})
    ]
    
    result = execute_get_request_queries (query)
    
    return view_helper.return_redfish_resource ("rack_chassis", values = result)
Пример #19
0
def post_switch_fw_update():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_config)

    validation = {"File": parameter_parser("fw_file", str)}
    params = validate_action_parameters(validation)

    switch = models.switch_manager.getswitch(load_config.switch_ip,
                                             load_config.switch_uart)
    result = switch.do_upgrade(**params)
    return check_action_result(result)
Пример #20
0
def post_system_remotemedia_mount(system):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_state,
                              device_id=system)

    validation = {"ImageName": parameter_parser("imagename", str)}
    params = validate_action_parameters(validation)

    result = controls.manage_rmedia.mount_rmedia(system, **params)
    return check_action_result(result)
Пример #21
0
def post_rack_manager_tftp_get():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_config)

    validation = {
        "Server": parameter_parser("server", str, IPAddress),
        "File": parameter_parser("file", str),
    }
    params = validate_action_parameters(validation)

    result = controls.manage_rack_manager.manager_tftp_client_get(**params)
    return check_action_result(result)
Пример #22
0
def post_accounts():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_config)

    validation = {
        "UserName": parameter_parser("username", str),
        "Password": parameter_parser("pwd", str),
        "RoleId": parameter_parser("role", str, RoleId)
    }
    params = validate_action_parameters(validation)

    result = controls.manage_user.user_create_new(**params)
    return check_action_result(result, success_code=201)
Пример #23
0
def get_system_log_entries (system):
    system = int (system)
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_blade_state,
        device_id = system)
    
    query = [
        (controls.bladelog_lib.read_server_log, {"serverid": system, "raw_output": False})
    ]
    
    result = execute_get_request_queries (query)
    result["EntryID"] = system
    
    return view_helper.return_redfish_resource ("system_log_entries", values = result)
Пример #24
0
def patch_rack_manager_chassis():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_state)

    actions = {
        "IndicatorLED":
        (controls.manage_rack_manager.set_rack_manager_attention_led,
         parameter_parser("setting", int, enums.IndicatorLED), {}),
    }

    result = validate_patch_request_and_execute(actions,
                                                "rack_manager_chassis")
    return get_handler.get_rack_manager_chassis(patch=result)
Пример #25
0
def get_switch_thermal ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (models.switch_manager.getswitch (load_config.switch_ip, "").getswitch_info, {})
    ]
    
    result = execute_get_request_queries (query)
    
    if ("TemperatureSensorState" in result):
            result["TemperatureSensorState"] = str (enums.Health (
                str(result["TemperatureSensorState"]), convert = True))
            
    return view_helper.return_redfish_resource ("switch_thermal", values = result)
Пример #26
0
def get_session (session):
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)

    query = [
        (controls.manage_rack_manager.manager_session, {"sessionid": int(session)})
    ]
    
    result = execute_get_request_queries (query, {"ID" : session})

    for error in result.get (view_helper.response_status_key, []):
        if ("Invalid session id" in error.get (completion_code.desc, "")):
            raise HTTPError (status = 404)
            
    return view_helper.return_redfish_resource ("session", values = result)
Пример #27
0
def get_system (system, patch = dict ()):
    system = int (system)
    if (not patch):
        view_helper.run_pre_check (pre_check.pre_check_function_call,
            command_name_enum.get_blade_state, device_id = system)
    
    query = [
        (controls.bladeinfo_lib.system_info_call, {"bladeId" : system}),
        (controls.bladepowerstate_lib.get_server_default_powerstate, {"serverid" : system}),
        (controls.bladetpmphypresence_lib.get_tpm_physical_presence, {"serverid" : system}),
        (controls.bladenextboot_lib.get_nextboot, {"serverid" : system})
    ]
    
    result = view_helper.flatten_nested_objects (
        execute_get_request_queries (query, {"ID" : system}))
    
    for health in ["Server_Status_HealthRollUp", "Server_Status_Health",
        "Server_ProcessorSummary_Status_HealthRollUp", "Server_ProcessorSummary_Status_Health",
        "Server_MemorySummary_Status_HealthRollUp", "Server_MemorySummary_Status_Health"]:
        if (health in result):
            result[health] = enums.Health (result[health], convert = True)
            
    for state in ["Server_Status_State", "Server_ProcessorSummary_Status_State",
        "Server_MemorySummary_Status_State"]:
        if (state in result):
            result[state] = enums.State (result[state], convert = True)
            
    for state in ["Sever_PowerState", "Default_Power_State"]:
        if (state in result):
            result[state] = enums.PowerState (result[state], convert = True)
    
    if ("BootSourceOverrideTarget" in result):
        result["BootSourceOverrideTarget"] = enums.BootSourceOverrideTarget (
            result["BootSourceOverrideTarget"], convert = True)
    if ("BootSourceOverrideMode" in result):
        result["bootSourceOverrideMode"] = enums.BootSourceOverrideMode (
            result["BootSourceOverrideMode"], convert = True)
    if ("PhysicalPresence" in result):
        result["PhysicalPresence"] = enums.Boolean (result["PhysicalPresence"], convert = True)
        
    if (result.get ("BootSourceOverrideTarget", "") == enums.BootSourceOverrideTarget.NONE):
        result["BootSourceOverrideEnabled"] = enums.BootSourceOverrideEnabled (
            enums.BootSourceOverrideEnabled.DISABLED)
    else:
        if ("BootSourceOverrideEnabled" in result):
            result["BootSourceOverrideEnabled"] = enums.BootSourceOverrideEnabled (
                result["BootSourceOverrideEnabled"], convert = True)
    
    view_helper.update_and_replace_status_information (result, patch)
    return view_helper.return_redfish_resource ("system", values = result)
Пример #28
0
def get_rack_manager_log ():
    view_helper.run_pre_check (pre_check.pre_check_function_call, command_name_enum.get_rm_state)
    
    query = [
        (controls.manage_rack_manager.show_rack_manager_log_status, {})
    ]
    
    result = execute_get_request_queries (query)
    
    if ("TelemetryDaemonStatus" in result):
        result["TelemetryDaemonStatus"] = enums.State (result["TelemetryDaemonStatus"],
            convert = True)
            
    return view_helper.return_redfish_resource ("rack_manager_log", values = result)
Пример #29
0
def post_switch_reset():
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_rm_state)

    validation = {
        "ResetType":
        parameter_parser("type", str, ResetType,
                         {"valid": [ResetType.FORCE_RESTART]})
    }
    validate_action_parameters(validation)

    switch = models.switch_manager.getswitch(load_config.switch_ip,
                                             load_config.switch_uart)
    result = switch.do_reset()
    return check_action_result(result)
Пример #30
0
def patch_system_chassis(system):
    system = int(system)
    view_helper.run_pre_check(pre_check.pre_check_function_call,
                              command_name_enum.set_blade_state,
                              device_id=system)

    actions = {
        "IndicatorLED": (controls.bladepowerstate_lib.set_server_attention_led,
                         parameter_parser("state", int, enums.IndicatorLED), {
                             "serverid": system
                         })
    }

    result = validate_patch_request_and_execute(actions, "system_chassis")
    return get_handler.get_system_chassis(system, patch=result)