class BP(Module, BPPanel): def __init__(self, *args, **kwds): config.read('rxbox.cfg') BPPanel.__init__(self, *args, **kwds) Module.__init__(self, *args, **kwds) self.Bind(wx.EVT_BUTTON, self.onBPNow, self.bpNow_Button) self.bp_pressure_indicator = wx.Gauge(self.bpbarpanel, -1, 250, size=(50, 100), style=wx.GA_VERTICAL) self.bp_pressure_indicator.Enable(False) #coeff=(1.593,-1.148,17.98,0.107,0.227,39.25),coeff=(0.981,0,-6.59,0,0.38741,38.45) self.bp = BPDAQ(self, port=config.get('BP', 'port'), coeff=(1, 0, 0, 0, 1, 0)) self.bp_pressure_indicator = wx.Gauge(self.bpbarpanel, -1, 250, size=(50, 100), style=wx.GA_VERTICAL) self.bp_pressure_indicator.Enable(False) self.alive = False self.updatealive = False self.bp_infolabel.SetLabel('Restart Software') self.bpNow_Button.Enable(False) def __name__(self): return 'BP' def onBPNow(self, event): self.Start() def Start(self): config.read('rxbox.cfg') port2check = [config.get('BP', 'port')] c = bp_portcheck.Bp_check(port2check) port = c.check() if port == None: self.bp_infolabel.SetLabel('Cannot Proceed:BP Unavailable') return #(config.get('BP','sys_coeff_a'),0,config.get('BP','sys_coeff_b'),0,config.get('BP','dias_coeff_a'),config.get('BP','dias_coeff_b')) self.bp = BPDAQ(self, port=config.get('BP', 'port'), coeff=(float(config.get('BP', 'sys_coeff_a')), 0, float(config.get('BP', 'sys_coeff_b')), 0, float(config.get('BP', 'dias_coeff_a')), float(config.get('BP', 'dias_coeff_b'))), debug=True, logger=self._logger) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(0.74212,0,19.00353,0,0.36265,45.688)) #(0.981,0,-6.59,0,0.38741,38.45) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(1,0,0,0,1,0)) self.bp.OpenSerial() self._logger.info('BP: ' + str(self.setBPmaxpressure_combobox.GetValue()[:3])) self.bp.send_request(self.setBPmaxpressure_combobox.GetValue()[:3]) self.setBPmaxpressure_combobox.Enable(False) self.bpNow_Button.SetToolTipString("Acquiring BP") self.bpdaq_thread = threading.Thread(target=self.Get_bp) self.bpdaq_thread.start() self._logger.info('DAQ Start') return True def Stop(self): if self.bp == True: if self.bp.nibp.isOpen() == True: self.bp.stop() self._logger.debug('BP serial deactivated') self._logger.info('DAQ Stop') return True def setGui(self, mode='unlock'): if mode not in ['lock', 'unlock']: self._logger.info('setGui mode unsupported') return if mode == 'lock': self.bpNow_Button.Enable(False) self.setBPmaxpressure_combobox.Enable(False) elif mode == 'unlock': self.bpNow_Button.Enable(True) self.setBPmaxpressure_combobox.Enable(True) def find_port(self, port_list): port2check = port_list c = bp_portcheck.Bp_check(port2check) port = c.check() self._logger.info('BP Port is ' + str(port)) return port def minor_check(self): config.read('rxbox.cfg') self.bp = BPDAQ(self, port=config.get('BP', 'port'), coeff=(1, 0, 0, 0, 1, 0), debug=True, logger=self._logger) status = self.bp.init_status_check() if status == False: self._logger.debug('BP: Initialization Failed') self.bp_infolabel.SetLabel('BP Unavailable:Restart Software') return self._logger.debug('BP init part 1 done') status = self.bp.init_firmware_version() if status == False: print 'initialization failed' self._logger.debug('BP: Initialization Failed') self.bp_infolabel.SetLabel('BP Unavailable:Restart Software') return self._logger.debug('BP: init part 2 done') self.bpNow_Button.Enable(True) self.bp_infolabel.SetLabel('BP Ready') def Get_bp(self): self.alive = True none_count = 0 while self.alive: time.sleep(0.1) press = self.bp.get_reply() if press == 'S5': press = '' continue if press == None or press == '': self._logger.debug('BP: none type returned') none_count += 1 if none_count < 1: continue else: press = '09990' try: self.press = int(press[1:4]) except: self._logger.debug('BP: BP packet mismatch, fixing') self.press = 999 if self.press == 999: self.alive = False self.bp.get() self.updatealive = False self.bp.stop() self.bp.CloseSerial() wx.CallAfter(self.pressure_update) self.bp.CloseSerial() def pressure_update(self): if self.press != 999: self.bpNow_Button.Enable(False) self.bp_pressure_indicator.SetValue(self.press) self.bp_infolabel.SetLabel(str(self.press) + ' mmHg') else: self.updatealive = False self.alive = False self.bp_pressure_indicator.SetValue(0) self.bp_infolabel.SetLabel(self.bp.bpstatus) self.bp_pressure_indicator.Enable(False) self.bpNow_Button.Enable(True) self.setBPmaxpressure_combobox.Enable(True) self.bpNow_Button.SetToolTipString("Acquire BP Reading") self.bpvalue_label.SetLabel( str(self.bp.bp_systolic) + '/' + str(self.bp.bp_diastolic))
class Calibration_main(MyFrame): def __init__(self, *args, **kwds): MyFrame.__init__(self, *args, **kwds) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff= (1,0,0,0,1,0)) self.SetTitle("BP Calibration") self.bp_pressure_indicator = wx.Gauge(self.bpbarpanel,-1, 250, size=(50, 130),style=wx.GA_VERTICAL) self.bp_pressure_indicator.Enable(False) self.alive=False self.updatealive=False self.bp_infolabel.SetLabel('Not Ready') self.bpNow_Button.Enable(True) self.Calibrate_button.Enable(False) self.button_1.Enable(False) self.button_1.SetLabel("RECORD NOW") self.Calibrate_button.SetLabel("CALIBRATE NOW") self.Sys_Merc_txt.SetValue("0") self.Dias_Merc_txt.SetValue("0") self.Sys_Comm_txt.SetValue("0") self.Dias_Comm_txt.SetValue("0") self.version_label.SetLabel('version: '+str(config.get('GENINFO','model'))) #self.minor_check() now = datetime.datetime.now() path=os.getcwd() if path[len(path)-14:]=='BP_Calibration': self.fileopen=open("Data/"+now.strftime("%m-%d-%y_%H-%M")+".csv","ab") else: self.fileopen=open(path+'/Modules/BP/BP_Calibration/Data/'+now.strftime("%m-%d-%y_%H-%M")+".csv","ab") self.csvfile=csv.writer(self.fileopen) data=["Mercurial Systolic","Mercurial Diastolic","Commercial Systolic","Commercial Diastolic","Uncalibrated Rxbox Systolic","Uncalibrated Rxbox Diastolic","Calibrated Rxbox Systolic","Calibrated Rxbox Diastolic"] self.ls=Ls() self.csv_writer(data) self.n_samples=0 def csv_writer(self,data): self.csvfile.writerow(data) def minor_check(self): self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(0.981,0,-6.59,0,0.38741,38.45)) status=self.bp.init_status_check() if status== False: print 'initialization failed' self.bp_infolabel.SetLabel('Not Ready') return print 'bp init part 1 done' status=self.bp.init_firmware_version() if status== False: print 'initialization failed' self.bp_infolabel.SetLabel('Not Ready') return print 'bp init part 2 done' self.bpNow_Button.Enable(True) self.bp_infolabel.SetLabel('BP Ready') def onBPNow(self, event): # wxGlade: MyFrame.<event_handler> self.bpNow_Button.Enable(False) self.Calibrate_button.Enable(False) self.button_1.Enable(False) self.start() def start(self): print 'BP START' port2check=[config.get('BP','port')] c=bp_portcheck.Bp_check(port2check) port=c.check() if port == None: self.bp_infolabel.SetLabel('Cannot Proceed:BP Unavailable') return self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(float(config.get('BP','sys_coeff_a')),0,float(config.get('BP','sys_coeff_b')),0,float(config.get('BP','dias_coeff_a')),float(config.get('BP','dias_coeff_b')))) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(0.74212,0,19.00353,0,0.36265,45.688)) self.bp.OpenSerial() self.bp.send_request(self.setBPmaxpressure_combobox.GetValue()[:3]) self.setBPmaxpressure_combobox.Enable(False) self.bpNow_Button.SetToolTipString("Acquiring BP") self.bpdaq_thread = threading.Thread(target=self.Get_bp) self.bpdaq_thread.start() return True def onRecord(self, event): # wxGlade: MyFrame.<event_handler> print self.Sys_Merc_txt.GetValue() print self.Dias_Merc_txt.GetValue() sys_real=int(self.Sys_Merc_txt.GetValue()) dias_real=int(self.Dias_Merc_txt.GetValue()) sys_comm=int(self.Sys_Comm_txt.GetValue()) dias_comm=int(self.Dias_Comm_txt.GetValue()) if (sys_real == 0 and dias_real == 0) or (sys_comm == 0 and dias_comm == 0): dlg = wx.MessageDialog(self, 'Please fill up the required fields', 'Error', wx.OK|wx.ICON_ERROR) dlg.ShowModal() dlg.Destroy() return sys_actual=int(self.bp.bp_systolic) dias_actual=int(self.bp.bp_diastolic) rawsys=int(self.bp.rawsys) rawdias=int(self.bp.rawdias) print "Data" print sys_real,sys_actual,dias_real,dias_actual self.ls.add(sys_real,rawsys,dias_real,rawdias) self.Sys_Merc_txt.SetValue("0") self.Dias_Merc_txt.SetValue("0") self.Sys_Comm_txt.SetValue("0") self.Dias_Comm_txt.SetValue("0") self.bpvalue_label.SetLabel("--/--") data=[sys_real,dias_real,sys_comm,dias_comm,rawsys,rawdias,sys_actual,dias_actual] self.csv_writer(data) self.button_1.Enable(False) print "add record" self.n_samples+=1 self.Samples_txt.SetLabel(str(self.n_samples)) if self.n_samples>2: self.Calibrate_button.Enable(True) def onCalibrate(self, event): # wxGlade: MyFrame.<event_handler> a_sys,b_sys,a_dias,b_dias=self.ls.get_coeffecients() self.n_samples=0 self.Samples_label.SetLabel(str(self.n_samples)) self.Sys_Merc_txt.SetValue("0") self.Dias_Merc_txt.SetValue("0") self.bpvalue_label.SetLabel("--/--") self.Calibrate_button.Enable(False) config.set('BP','sys_coeff_a',a_sys) config.set('BP','sys_coeff_b',b_sys) config.set('BP','dias_coeff_a',a_dias) config.set('BP','dias_coeff_b',b_dias) path=os.getcwd() if path[len(path)-14:]=='BP_Calibration': configfile = open('../../../rxbox.cfg', 'wb') else: configfile = open('rxbox.cfg', 'wb') config.write(configfile) configfile.close() dlg = wx.MessageDialog(self, 'Calibration Successful', 'Confirmation', wx.OK|wx.ICON_INFORMATION) dlg.ShowModal() dlg.Destroy() def Get_bp(self): self.alive=True none_count=0 while self.alive: time.sleep(0.1) press = self.bp.get_reply() if press == 'S5': press ='' continue if press == None or press == '': print 'none type returned' none_count+=1 if none_count<1: continue else: press='09990' try: self.press = int(press[1:4]) except: print 'bp error' print press self.press=999 if self.press== 999: self.alive=False self.bp.get() self.updatealive=False self.bp.stop() self.bp.CloseSerial() wx.CallAfter(self.pressure_update) self.bp.CloseSerial() def pressure_update(self): if self.press != 999: self.bpNow_Button.Enable(False) self.bp_pressure_indicator.SetValue(self.press) self.bp_infolabel.SetLabel(str(self.press)+' mmHg') else: self.updatealive=False self.alive=False self.bp_pressure_indicator.SetValue(0) self.bp_infolabel.SetLabel(self.bp.bpstatus) self.bp_pressure_indicator.Enable(False) self.bpNow_Button.Enable(True) self.setBPmaxpressure_combobox.Enable(True) self.button_1.Enable(True) self.bpNow_Button.SetToolTipString("Acquire BP Reading") self.bpvalue_label.SetLabel(' Cal UnCal \n'+str(self.bp.bp_systolic)+'/'+str(self.bp.bp_diastolic)+' '+str(self.bp.rawsys)+'/'+str(self.bp.rawdias))
class Calibration_main(MyFrame): def __init__(self, *args, **kwds): MyFrame.__init__(self, *args, **kwds) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff= (1,0,0,0,1,0)) self.SetTitle("BP Calibration") self.bp_pressure_indicator = wx.Gauge(self.bpbarpanel, -1, 250, size=(50, 130), style=wx.GA_VERTICAL) self.bp_pressure_indicator.Enable(False) self.alive = False self.updatealive = False self.bp_infolabel.SetLabel('Not Ready') self.bpNow_Button.Enable(True) self.Calibrate_button.Enable(False) self.button_1.Enable(False) self.button_1.SetLabel("RECORD NOW") self.Calibrate_button.SetLabel("CALIBRATE NOW") self.Sys_Merc_txt.SetValue("0") self.Dias_Merc_txt.SetValue("0") self.Sys_Comm_txt.SetValue("0") self.Dias_Comm_txt.SetValue("0") self.version_label.SetLabel('version: ' + str(config.get('GENINFO', 'model'))) #self.minor_check() now = datetime.datetime.now() path = os.getcwd() if path[len(path) - 14:] == 'BP_Calibration': self.fileopen = open( "Data/" + now.strftime("%m-%d-%y_%H-%M") + ".csv", "ab") else: self.fileopen = open( path + '/Modules/BP/BP_Calibration/Data/' + now.strftime("%m-%d-%y_%H-%M") + ".csv", "ab") self.csvfile = csv.writer(self.fileopen) data = [ "Mercurial Systolic", "Mercurial Diastolic", "Commercial Systolic", "Commercial Diastolic", "Uncalibrated Rxbox Systolic", "Uncalibrated Rxbox Diastolic", "Calibrated Rxbox Systolic", "Calibrated Rxbox Diastolic" ] self.ls = Ls() self.csv_writer(data) self.n_samples = 0 def csv_writer(self, data): self.csvfile.writerow(data) def minor_check(self): self.bp = BPDAQ(self, port=config.get('BP', 'port'), coeff=(0.981, 0, -6.59, 0, 0.38741, 38.45)) status = self.bp.init_status_check() if status == False: print 'initialization failed' self.bp_infolabel.SetLabel('Not Ready') return print 'bp init part 1 done' status = self.bp.init_firmware_version() if status == False: print 'initialization failed' self.bp_infolabel.SetLabel('Not Ready') return print 'bp init part 2 done' self.bpNow_Button.Enable(True) self.bp_infolabel.SetLabel('BP Ready') def onBPNow(self, event): # wxGlade: MyFrame.<event_handler> self.bpNow_Button.Enable(False) self.Calibrate_button.Enable(False) self.button_1.Enable(False) self.start() def start(self): print 'BP START' port2check = [config.get('BP', 'port')] c = bp_portcheck.Bp_check(port2check) port = c.check() if port == None: self.bp_infolabel.SetLabel('Cannot Proceed:BP Unavailable') return self.bp = BPDAQ(self, port=config.get('BP', 'port'), coeff=(float(config.get('BP', 'sys_coeff_a')), 0, float(config.get('BP', 'sys_coeff_b')), 0, float(config.get('BP', 'dias_coeff_a')), float(config.get('BP', 'dias_coeff_b')))) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(0.74212,0,19.00353,0,0.36265,45.688)) self.bp.OpenSerial() self.bp.send_request(self.setBPmaxpressure_combobox.GetValue()[:3]) self.setBPmaxpressure_combobox.Enable(False) self.bpNow_Button.SetToolTipString("Acquiring BP") self.bpdaq_thread = threading.Thread(target=self.Get_bp) self.bpdaq_thread.start() return True def onRecord(self, event): # wxGlade: MyFrame.<event_handler> print self.Sys_Merc_txt.GetValue() print self.Dias_Merc_txt.GetValue() sys_real = int(self.Sys_Merc_txt.GetValue()) dias_real = int(self.Dias_Merc_txt.GetValue()) sys_comm = int(self.Sys_Comm_txt.GetValue()) dias_comm = int(self.Dias_Comm_txt.GetValue()) if (sys_real == 0 and dias_real == 0) or (sys_comm == 0 and dias_comm == 0): dlg = wx.MessageDialog(self, 'Please fill up the required fields', 'Error', wx.OK | wx.ICON_ERROR) dlg.ShowModal() dlg.Destroy() return sys_actual = int(self.bp.bp_systolic) dias_actual = int(self.bp.bp_diastolic) rawsys = int(self.bp.rawsys) rawdias = int(self.bp.rawdias) print "Data" print sys_real, sys_actual, dias_real, dias_actual self.ls.add(sys_real, rawsys, dias_real, rawdias) self.Sys_Merc_txt.SetValue("0") self.Dias_Merc_txt.SetValue("0") self.Sys_Comm_txt.SetValue("0") self.Dias_Comm_txt.SetValue("0") self.bpvalue_label.SetLabel("--/--") data = [ sys_real, dias_real, sys_comm, dias_comm, rawsys, rawdias, sys_actual, dias_actual ] self.csv_writer(data) self.button_1.Enable(False) print "add record" self.n_samples += 1 self.Samples_txt.SetLabel(str(self.n_samples)) if self.n_samples > 2: self.Calibrate_button.Enable(True) def onCalibrate(self, event): # wxGlade: MyFrame.<event_handler> a_sys, b_sys, a_dias, b_dias = self.ls.get_coeffecients() self.n_samples = 0 self.Samples_label.SetLabel(str(self.n_samples)) self.Sys_Merc_txt.SetValue("0") self.Dias_Merc_txt.SetValue("0") self.bpvalue_label.SetLabel("--/--") self.Calibrate_button.Enable(False) config.set('BP', 'sys_coeff_a', a_sys) config.set('BP', 'sys_coeff_b', b_sys) config.set('BP', 'dias_coeff_a', a_dias) config.set('BP', 'dias_coeff_b', b_dias) path = os.getcwd() if path[len(path) - 14:] == 'BP_Calibration': configfile = open('../../../rxbox.cfg', 'wb') else: configfile = open('rxbox.cfg', 'wb') config.write(configfile) configfile.close() dlg = wx.MessageDialog(self, 'Calibration Successful', 'Confirmation', wx.OK | wx.ICON_INFORMATION) dlg.ShowModal() dlg.Destroy() def Get_bp(self): self.alive = True none_count = 0 while self.alive: time.sleep(0.1) press = self.bp.get_reply() if press == 'S5': press = '' continue if press == None or press == '': print 'none type returned' none_count += 1 if none_count < 1: continue else: press = '09990' try: self.press = int(press[1:4]) except: print 'bp error' print press self.press = 999 if self.press == 999: self.alive = False self.bp.get() self.updatealive = False self.bp.stop() self.bp.CloseSerial() wx.CallAfter(self.pressure_update) self.bp.CloseSerial() def pressure_update(self): if self.press != 999: self.bpNow_Button.Enable(False) self.bp_pressure_indicator.SetValue(self.press) self.bp_infolabel.SetLabel(str(self.press) + ' mmHg') else: self.updatealive = False self.alive = False self.bp_pressure_indicator.SetValue(0) self.bp_infolabel.SetLabel(self.bp.bpstatus) self.bp_pressure_indicator.Enable(False) self.bpNow_Button.Enable(True) self.setBPmaxpressure_combobox.Enable(True) self.button_1.Enable(True) self.bpNow_Button.SetToolTipString("Acquire BP Reading") self.bpvalue_label.SetLabel(' Cal UnCal \n' + str(self.bp.bp_systolic) + '/' + str(self.bp.bp_diastolic) + ' ' + str(self.bp.rawsys) + '/' + str(self.bp.rawdias))
class BP (Module, BPPanel): def __init__(self, *args, **kwds): config.read('rxbox.cfg') BPPanel.__init__(self, *args, **kwds) Module.__init__(self, *args, **kwds) self.Bind(wx.EVT_BUTTON, self.onBPNow, self.bpNow_Button) self.bp_pressure_indicator = wx.Gauge(self.bpbarpanel,-1, 250, size=(50, 100),style=wx.GA_VERTICAL) self.bp_pressure_indicator.Enable(False) #coeff=(1.593,-1.148,17.98,0.107,0.227,39.25),coeff=(0.981,0,-6.59,0,0.38741,38.45) self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(1,0,0,0,1,0)) self.bp_pressure_indicator = wx.Gauge(self.bpbarpanel,-1, 250, size=(50, 100),style=wx.GA_VERTICAL) self.bp_pressure_indicator.Enable(False) self.alive=False self.updatealive=False self.bp_infolabel.SetLabel('Restart Software') self.bpNow_Button.Enable(False) def __name__(self): return 'BP' def onBPNow(self, event): self.Start() def Start(self): config.read('rxbox.cfg') port2check=[config.get('BP','port')] c=bp_portcheck.Bp_check(port2check) port=c.check() if port == None: self.bp_infolabel.SetLabel('Cannot Proceed:BP Unavailable') return #(config.get('BP','sys_coeff_a'),0,config.get('BP','sys_coeff_b'),0,config.get('BP','dias_coeff_a'),config.get('BP','dias_coeff_b')) self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(float(config.get('BP','sys_coeff_a')),0,float(config.get('BP','sys_coeff_b')),0,float(config.get('BP','dias_coeff_a')),float(config.get('BP','dias_coeff_b'))),debug=True,logger=self._logger) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(0.74212,0,19.00353,0,0.36265,45.688)) #(0.981,0,-6.59,0,0.38741,38.45) #self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(1,0,0,0,1,0)) self.bp.OpenSerial() self._logger.info('BP: '+str(self.setBPmaxpressure_combobox.GetValue()[:3])) self.bp.send_request(self.setBPmaxpressure_combobox.GetValue()[:3]) self.setBPmaxpressure_combobox.Enable(False) self.bpNow_Button.SetToolTipString("Acquiring BP") self.bpdaq_thread = threading.Thread(target=self.Get_bp) self.bpdaq_thread.start() self._logger.info('DAQ Start') return True def Stop(self): if self.bp==True: if self.bp.nibp.isOpen()== True: self.bp.stop() self._logger.debug('BP serial deactivated') self._logger.info('DAQ Stop') return True def setGui(self, mode='unlock'): if mode not in ['lock','unlock']: self._logger.info('setGui mode unsupported') return if mode == 'lock': self.bpNow_Button.Enable(False) self.setBPmaxpressure_combobox.Enable(False) elif mode == 'unlock': self.bpNow_Button.Enable(True) self.setBPmaxpressure_combobox.Enable(True) def find_port(self,port_list): port2check=port_list c=bp_portcheck.Bp_check(port2check) port=c.check() self._logger.info('BP Port is '+str(port)) return port def minor_check(self): config.read('rxbox.cfg') self.bp = BPDAQ(self,port =config.get('BP','port'),coeff=(1,0,0,0,1,0),debug=True,logger=self._logger) status=self.bp.init_status_check() if status== False: self._logger.debug('BP: Initialization Failed') self.bp_infolabel.SetLabel('BP Unavailable:Restart Software') return self._logger.debug('BP init part 1 done') status=self.bp.init_firmware_version() if status== False: print 'initialization failed' self._logger.debug('BP: Initialization Failed') self.bp_infolabel.SetLabel('BP Unavailable:Restart Software') return self._logger.debug('BP: init part 2 done') self.bpNow_Button.Enable(True) self.bp_infolabel.SetLabel('BP Ready') def Get_bp(self): self.alive=True none_count=0 while self.alive: time.sleep(0.1) press = self.bp.get_reply() if press == 'S5': press ='' continue if press == None or press == '': self._logger.debug('BP: none type returned') none_count+=1 if none_count<1: continue else: press='09990' try: self.press = int(press[1:4]) except: self._logger.debug('BP: BP packet mismatch, fixing') self.press=999 if self.press== 999: self.alive=False self.bp.get() self.updatealive=False self.bp.stop() self.bp.CloseSerial() wx.CallAfter(self.pressure_update) self.bp.CloseSerial() def pressure_update(self): if self.press != 999: self.bpNow_Button.Enable(False) self.bp_pressure_indicator.SetValue(self.press) self.bp_infolabel.SetLabel(str(self.press)+' mmHg') else: self.updatealive=False self.alive=False self.bp_pressure_indicator.SetValue(0) self.bp_infolabel.SetLabel(self.bp.bpstatus) self.bp_pressure_indicator.Enable(False) self.bpNow_Button.Enable(True) self.setBPmaxpressure_combobox.Enable(True) self.bpNow_Button.SetToolTipString("Acquire BP Reading") self.bpvalue_label.SetLabel(str(self.bp.bp_systolic)+'/'+str(self.bp.bp_diastolic))