示例#1
0
文件: fmap.py 项目: tknapen/fmriprep
def get_trt(in_meta, in_file=None):
    """
    Calculate the *total readout time* for an input
    :abbr:`EPI (echo-planar imaging)` scan.


    There are several procedures to calculate the total
    readout time. The basic one is that a ``TotalReadoutTime``
    field is set in the JSON sidecar. The following examples
    use an ``'epi.nii.gz'`` file-stub which has 90 pixels in the
    j-axis encoding direction.

    >>> meta = {'TotalReadoutTime': 0.02596}
    >>> get_trt(meta)
    0.02596

    If the *effective echo spacing* :math:`t_\\text{ees}`
    (``EffectiveEchoSpacing`` BIDS field) is provided, then the
    total readout time can be calculated reading the number
    of voxels along the readout direction :math:`T_\\text{ro}`
    and the parallel acceleration factor of the EPI :math:`f_\\text{acc}`.

      .. math ::

          T_\\text{ro} = t_\\text{ees} \\, (N_\\text{PE} / f_\\text{acc} - 1)

    >>> meta = {'EffectiveEchoSpacing': 0.00059,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_trt(meta, in_file='epi.nii.gz')
    0.02596

    Some vendors, like Philips, store different parameter names:

    >>> meta = {'WaterFatShift': 8.129,
    ...         'MagneticFieldStrength': 3,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_trt(meta, in_file='epi.nii.gz')
    0.018721183563864822

    """

    # Use case 1: TRT is defined
    trt = in_meta.get('TotalReadoutTime', None)
    if trt is not None:
        return trt

    # All other cases require the parallel acc and npe (N vox in PE dir)
    acc = float(in_meta.get('ParallelReductionFactorInPlane', 1.0))
    npe = nb.load(in_file).shape[_get_pe_index(in_meta)]
    etl = npe // acc

    # Use case 2: TRT is defined
    ees = in_meta.get('EffectiveEchoSpacing', None)
    if ees is not None:
        return ees * (etl - 1)

    # Use case 3 (philips scans)
    wfs = in_meta.get('WaterFatShift', None)
    if wfs is not None:
        fstrength = in_meta['MagneticFieldStrength']
        wfd_ppm = 3.4  # water-fat diff in ppm
        g_ratio_mhz_t = 42.57  # gyromagnetic ratio for proton (1H) in MHz/T
        wfs_hz = fstrength * wfd_ppm * g_ratio_mhz_t
        return wfs / wfs_hz

    raise ValueError('Unknown total-readout time specification')
示例#2
0
def get_trt(in_meta, in_file=None):
    """
    Calculate the *total readout time* for an input
    :abbr:`EPI (echo-planar imaging)` scan.


    There are several procedures to calculate the total
    readout time. The basic one is that a ``TotalReadoutTime``
    field is set in the JSON sidecar. The following examples
    use an ``'epi.nii.gz'`` file-stub which has 90 pixels in the
    j-axis encoding direction.

    >>> meta = {'TotalReadoutTime': 0.02596}
    >>> get_trt(meta)
    0.02596

    If the *effective echo spacing* :math:`t_\\text{ees}`
    (``EffectiveEchoSpacing`` BIDS field) is provided, then the
    total readout time can be calculated reading the number
    of voxels along the readout direction :math:`T_\\text{ro}`
    and the parallel acceleration factor of the EPI :math:`f_\\text{acc}`.

      .. math ::

          T_\\text{ro} = t_\\text{ees} \\, (N_\\text{PE} / f_\\text{acc} - 1)

    >>> meta = {'EffectiveEchoSpacing': 0.00059,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_trt(meta, in_file='epi.nii.gz')
    0.02596

    Some vendors, like Philips, store different parameter names:

    >>> meta = {'WaterFatShift': 8.129,
    ...         'MagneticFieldStrength': 3,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_trt(meta, in_file='epi.nii.gz')
    0.018721183563864822

    """

    # Use case 1: TRT is defined
    trt = in_meta.get('TotalReadoutTime', None)
    if trt is not None:
        return trt

    # All other cases require the parallel acc and npe (N vox in PE dir)
    acc = float(in_meta.get('ParallelReductionFactorInPlane', 1.0))
    npe = nb.load(in_file).shape[_get_pe_index(in_meta)]
    etl = npe // acc

    # Use case 2: TRT is defined
    ees = in_meta.get('EffectiveEchoSpacing', None)
    if ees is not None:
        return ees * (etl - 1)

    # Use case 3 (philips scans)
    wfs = in_meta.get('WaterFatShift', None)
    if wfs is not None:
        fstrength = in_meta['MagneticFieldStrength']
        wfd_ppm = 3.4  # water-fat diff in ppm
        g_ratio_mhz_t = 42.57  # gyromagnetic ratio for proton (1H) in MHz/T
        wfs_hz = fstrength * wfd_ppm * g_ratio_mhz_t
        return wfs / wfs_hz

    raise ValueError('Unknown total-readout time specification')
示例#3
0
文件: fmap.py 项目: tknapen/fmriprep
def get_ees(in_meta, in_file=None):
    """
    Calculate the *effective echo spacing* :math:`t_\\text{ees}`
    for an input :abbr:`EPI (echo-planar imaging)` scan.


    There are several procedures to calculate the effective
    echo spacing. The basic one is that an ``EffectiveEchoSpacing``
    field is set in the JSON sidecar. The following examples
    use an ``'epi.nii.gz'`` file-stub which has 90 pixels in the
    j-axis encoding direction.

    >>> meta = {'EffectiveEchoSpacing': 0.00059,
    ...         'PhaseEncodingDirection': 'j-'}
    >>> get_ees(meta)
    0.00059

    If the *total readout time* :math:`T_\\text{ro}` (``TotalReadoutTime``
    BIDS field) is provided, then the effective echo spacing can be
    calculated reading the number of voxels :math:`N_\\text{PE}` along the
    readout direction and the parallel acceleration
    factor of the EPI

      .. math ::

           =  T_\\text{ro} \\,  (N_\\text{PE} / f_\\text{acc} - 1)^{-1}

    where :math:`N_y` is the number of pixels along the phase-encoding direction
    :math:`y`, and :math:`f_\\text{acc}` is the parallel imaging acceleration factor
    (:abbr:`GRAPPA (GeneRalized Autocalibrating Partial Parallel Acquisition)`,
    :abbr:`ARC (Autocalibrating Reconstruction for Cartesian imaging)`, etc.).

    >>> meta = {'TotalReadoutTime': 0.02596,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_ees(meta, in_file='epi.nii.gz')
    0.00059

    Some vendors, like Philips, store different parameter names
    (see http://dbic.dartmouth.edu/pipermail/mrusers/attachments/\
20141112/eb1d20e6/attachment.pdf):

    >>> meta = {'WaterFatShift': 8.129,
    ...         'MagneticFieldStrength': 3,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_ees(meta, in_file='epi.nii.gz')
    0.00041602630141921826

    """

    import nibabel as nb
    from fmriprep.interfaces.fmap import _get_pe_index

    # Use case 1: EES is defined
    ees = in_meta.get('EffectiveEchoSpacing', None)
    if ees is not None:
        return ees

    # All other cases require the parallel acc and npe (N vox in PE dir)
    acc = float(in_meta.get('ParallelReductionFactorInPlane', 1.0))
    npe = nb.load(in_file).shape[_get_pe_index(in_meta)]
    etl = npe // acc

    # Use case 2: TRT is defined
    trt = in_meta.get('TotalReadoutTime', None)
    if trt is not None:
        return trt / (etl - 1)

    # Use case 3 (philips scans)
    wfs = in_meta.get('WaterFatShift', None)
    if wfs is not None:
        fstrength = in_meta['MagneticFieldStrength']
        wfd_ppm = 3.4  # water-fat diff in ppm
        g_ratio_mhz_t = 42.57  # gyromagnetic ratio for proton (1H) in MHz/T
        wfs_hz = fstrength * wfd_ppm * g_ratio_mhz_t
        return wfs / (wfs_hz * etl)

    raise ValueError('Unknown effective echo-spacing specification')
示例#4
0
def get_ees(in_meta, in_file=None):
    """
    Calculate the *effective echo spacing* :math:`t_\\text{ees}`
    for an input :abbr:`EPI (echo-planar imaging)` scan.


    There are several procedures to calculate the effective
    echo spacing. The basic one is that an ``EffectiveEchoSpacing``
    field is set in the JSON sidecar. The following examples
    use an ``'epi.nii.gz'`` file-stub which has 90 pixels in the
    j-axis encoding direction.

    >>> meta = {'EffectiveEchoSpacing': 0.00059,
    ...         'PhaseEncodingDirection': 'j-'}
    >>> get_ees(meta)
    0.00059

    If the *total readout time* :math:`T_\\text{ro}` (``TotalReadoutTime``
    BIDS field) is provided, then the effective echo spacing can be
    calculated reading the number of voxels :math:`N_\\text{PE}` along the
    readout direction and the parallel acceleration
    factor of the EPI

      .. math ::

           =  T_\\text{ro} \\,  (N_\\text{PE} / f_\\text{acc} - 1)^{-1}

    where :math:`N_y` is the number of pixels along the phase-encoding direction
    :math:`y`, and :math:`f_\\text{acc}` is the parallel imaging acceleration factor
    (:abbr:`GRAPPA (GeneRalized Autocalibrating Partial Parallel Acquisition)`,
    :abbr:`ARC (Autocalibrating Reconstruction for Cartesian imaging)`, etc.).

    >>> meta = {'TotalReadoutTime': 0.02596,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_ees(meta, in_file='epi.nii.gz')
    0.00059

    Some vendors, like Philips, store different parameter names
    (see http://dbic.dartmouth.edu/pipermail/mrusers/attachments/\
20141112/eb1d20e6/attachment.pdf):

    >>> meta = {'WaterFatShift': 8.129,
    ...         'MagneticFieldStrength': 3,
    ...         'PhaseEncodingDirection': 'j-',
    ...         'ParallelReductionFactorInPlane': 2}
    >>> get_ees(meta, in_file='epi.nii.gz')
    0.00041602630141921826

    """

    import nibabel as nb
    from fmriprep.interfaces.fmap import _get_pe_index

    # Use case 1: EES is defined
    ees = in_meta.get('EffectiveEchoSpacing', None)
    if ees is not None:
        return ees

    # All other cases require the parallel acc and npe (N vox in PE dir)
    acc = float(in_meta.get('ParallelReductionFactorInPlane', 1.0))
    npe = nb.load(in_file).shape[_get_pe_index(in_meta)]
    etl = npe // acc

    # Use case 2: TRT is defined
    trt = in_meta.get('TotalReadoutTime', None)
    if trt is not None:
        return trt / (etl - 1)

    # Use case 3 (philips scans)
    wfs = in_meta.get('WaterFatShift', None)
    if wfs is not None:
        fstrength = in_meta['MagneticFieldStrength']
        wfd_ppm = 3.4  # water-fat diff in ppm
        g_ratio_mhz_t = 42.57  # gyromagnetic ratio for proton (1H) in MHz/T
        wfs_hz = fstrength * wfd_ppm * g_ratio_mhz_t
        return wfs / (wfs_hz * etl)

    raise ValueError('Unknown effective echo-spacing specification')