def read_cfg_from_file(): from harmonicIO.general.services import Services if not Services.is_file_exist('harmonicIO/worker/configuration.json'): SysOut.terminate_string( 'harmonicIO/worker/configuration.json does not exist') else: with open('harmonicIO/worker/configuration.json', 'rt') as t: import json cfg = json.loads(t.read()) try: from harmonicIO.general.definition import Definition # Check for the json structure if Definition.get_str_node_name() in cfg and \ Definition.get_str_node_port() in cfg and \ Definition.get_str_data_port_range() in cfg and \ Definition.get_str_idle_time() in cfg and \ Definition.get_str_master_addr() in cfg and \ Definition.get_str_master_port() in cfg and \ Definition.get_str_node_external_addr() in cfg and \ Definition.get_str_node_internal_addr(): # Check port number is int or not if not isinstance(cfg[Definition.get_str_node_port()], int): SysOut.terminate_string( "Node port must be integer.") elif not isinstance( cfg[Definition.get_str_data_port_range()], list): SysOut.terminate_string("Port range must be list.") elif not (isinstance(cfg[Definition.get_str_data_port_range()][0], int) and \ isinstance(cfg[Definition.get_str_data_port_range()][1], int)): SysOut.terminate_string( "Port range must be integer.") elif not isinstance( cfg[Definition.get_str_master_port()], int): SysOut.terminate_string( "Master port must be integer.") elif len(cfg[ Definition.get_str_data_port_range()]) != 2: SysOut.terminate_string( "Port range must compost of two elements: start, stop." ) elif not isinstance( cfg[Definition.get_str_idle_time()], int): SysOut.terminate_string( "Idle time must be integer.") elif cfg[Definition.get_str_data_port_range()][0] > \ cfg[Definition.get_str_data_port_range()][1]: SysOut.terminate_string( "Start port range must greater than stop port range." ) else: Setting.set_node_addr() import multiprocessing Setting.__node_name = cfg[ Definition.get_str_node_name()].strip() Setting.__node_port = cfg[ Definition.get_str_node_port()] Setting.__node_data_port_start = cfg[ Definition.get_str_data_port_range()][0] Setting.__node_data_port_stop = cfg[ Definition.get_str_data_port_range()][1] Setting.__std_idle_time = cfg[ Definition.get_str_idle_time()] Setting.__master_addr = cfg[ Definition.get_str_master_addr()].strip() Setting.__master_port = cfg[ Definition.get_str_master_port()] Setting.__node_external_addr = cfg[ Definition.get_str_node_external_addr()].strip( ).lower() # Check for auto node name if Setting.__node_name.lower() == "auto": # Get node name from host name import socket Setting.__node_name = socket.gethostname() # Check for overriding node address if cfg[Definition.get_str_node_internal_addr()] and \ cfg[Definition.get_str_node_internal_addr()] != "auto": # Set node name automatically from hostname from harmonicIO.general.services import Services if Services.is_valid_ipv4(cfg[Definition.get_str_node_internal_addr()]) or \ Services.is_valid_ipv6(cfg[Definition.get_str_node_internal_addr()]): Setting.__node_internal_addr = cfg[ Definition.get_str_node_internal_addr( )] # Check for node address validity if Setting.get_node_external_addr() != "none": from harmonicIO.general.services import Services if Services.is_valid_ipv4(Setting.get_node_external_addr()) or \ Services.is_valid_ipv6(Setting.get_node_external_addr()): SysOut.out_string( "By pass request with external address." ) else: SysOut.terminate_string( "Invaliid external ip address!") else: Setting.__node_external_addr = None SysOut.out_string("Load setting successful.") else: SysOut.terminate_string( "Required parameters are not present.") except Exception as e: print(e) SysOut.terminate_string( "Invalid data in configuration file.")
def read_cfg_from_file(): from harmonicIO.general.services import Services, SysOut if not Services.is_file_exist('harmonicIO/master/configuration.json'): SysOut.terminate_string( 'harmonicIO/master/configuration.json does not exist!') else: with open('harmonicIO/master/configuration.json', 'rt') as t: import json cfg = json.loads(t.read()) try: from harmonicIO.general.definition import Definition # Check for the json structure if Definition.get_str_node_name() in cfg and \ Definition.get_str_node_port() in cfg and \ Definition.get_str_master_addr() in cfg and \ Definition.get_str_data_port_range() in cfg and \ Definition.get_str_idle_time() in cfg: # Check port number is int or not if not isinstance(cfg[Definition.get_str_node_port()], int): SysOut.terminate_string( "Node port must be integer!") if not isinstance( cfg[Definition.get_str_master_addr()], str): SysOut.terminate_string( "Master address must be string!") elif not isinstance( cfg[Definition.get_str_data_port_range()], list): SysOut.terminate_string("Port range must be list!") elif not (isinstance(cfg[Definition.get_str_data_port_range()][0], int) and \ isinstance(cfg[Definition.get_str_data_port_range()][1], int)): SysOut.terminate_string( "Port range must be integer!") elif len(cfg[ Definition.get_str_data_port_range()]) != 2: SysOut.terminate_string( "Port range must compost of two elements: start, stop!" ) elif not isinstance( cfg[Definition.get_str_idle_time()], int): SysOut.terminate_string( "Idle time must be integer!") elif cfg[Definition.get_str_data_port_range()][0] > \ cfg[Definition.get_str_data_port_range()][1]: SysOut.terminate_string( "Start port range must greater than stop port range!" ) else: Setting.__node_name = cfg[ Definition.get_str_node_name()].strip() Setting.__node_port = cfg[ Definition.get_str_node_port()] Setting.__node_data_port_start = cfg[ Definition.get_str_data_port_range()][0] Setting.__node_data_port_stop = cfg[ Definition.get_str_data_port_range()][1] Setting.__std_idle_time = cfg[ Definition.get_str_idle_time()] SysOut.out_string("Load setting successful.") try: if cfg[Definition.get_str_master_addr()].lower( ) == "auto": Setting.__node_addr = Services.get_host_name_i( ) SysOut.out_string( "Assigning master ip address automatically." ) elif Services.is_valid_ipv4(cfg[Definition.get_str_master_addr()]) or \ Services.is_valid_ipv6(cfg[Definition.get_str_master_addr()]): Setting.set_node_addr( cfg[Definition.get_str_master_addr()]) else: SysOut.terminate_string( "Invalid master IP address format!") except: SysOut.terminate_string( "Cannot assign IP address to the master!") else: SysOut.terminate_string( "Invalid data in configuration file.") except: SysOut.terminate_string( "Invalid data in configuration file.")