def main(): parser = argparse.ArgumentParser( description='Connect to a Rohde & Schwarz VNA') parser.add_argument('--visa', metavar='bus', default=False, help="use VISA with 'bus'") parser.add_argument('--address', default='127.0.0.1', help='instrument address') parser.add_argument('--timeout', default=5000, type=int, help='default instrument timeout (ms)') parser.add_argument('--log', default='', help='SCPI command log filename') args = parser.parse_args() vna = Vna() try: if args.visa: vna.open(args.visa, args.address) else: vna.open_tcp(args.address) if args.timeout: vna.timeout_ms = args.timeout if vna.connected(): print("connected: {0}".format(vna.id_string())) if args.log: vna.open_log(args.log) vna.log.write('{0}\n'.format(datetime.datetime.now())) vna.log.write('--------------------------\n\n') vna.print_info() sys.path.insert(0, os.getcwd()) code.interact('', local=locals()) sys.exit(0) else: raise Exception('Could not connect to instrument') except SystemExit: pass except: print('Error connecting to instrument\n') parser.print_help() finally: if vna.log: vna.close_log() if vna.connected(): vna.close()
def main(): parser = argparse.ArgumentParser(description='Connect to a Rohde & Schwarz VNA') parser.add_argument('--visa', metavar='bus', default=False, help="use VISA with 'bus'") parser.add_argument('--address', default='127.0.0.1', help='instrument address') parser.add_argument('--log', default='', help='SCPI command log filename') args = parser.parse_args() vna = Vna() try: if args.visa: vna.open(args.visa, args.address) else: vna.open_tcp(args.address) if vna.connected(): print("connected: {0}".format(vna.id_string())) if args.log: vna.open_log(args.log) vna.log.write('{0}\n'.format(datetime.datetime.now())) vna.log.write('--------------------------\n\n') vna.print_info() code.interact('', local=locals()) else: print('Could not connect to instrument\n') parser.print_help() except SystemExit: pass except: print('Error connecting to instrument\n') parser.print_help() finally: if vna.log: vna.close_log() if vna.connected(): vna.close()
# Complex formats are: # - COMP (Re, Im) # - LINP (Linear magnitude, phase [deg]) # - LOGP (Log magnitude [dB], phase [deg]) complex_format = "COMP" scpi = ":MMEM:STOR:TRAC:PORT {0},'{1}',{2},{3}" scpi = scpi.format(channel, 'temp.s4p', complex_format, ports_string) vna.write(scpi) # Save trace data to vna as # displayed on screen # Note: See command documentation for # additional data format options scpi = ":MMEM:STOR:TRAC '{0}', '{1}', FORM" scpi = scpi.format(trace_name, 'temp.csv') vna.write(scpi) # Wait for saves to complete vna.query("*OPC?") # Transfer files from vna # - See read_file.py vna.file.download_file("temp.s4p", touchstone_filename) vna.file.download_file("temp.csv", trace_filename) # Delete files from vna vna.file.delete("temp.s4p") vna.file.delete("temp.csv") vna.close()
def tearDownClass(self): vna = Vna() vna.open_tcp() vna.close()
def main(): parser = argparse.ArgumentParser( description='Connect to a Rohde & Schwarz VNA') parser.add_argument('--visa', metavar='bus', default=False, help="use VISA with 'bus'") parser.add_argument('--address', default='127.0.0.1', help='instrument address') parser.add_argument('--port', default=5025, type=int, help='port (TCP only)') parser.add_argument('--timeout', default=5000, type=int, help='default instrument timeout (ms)') parser.add_argument('--log', help='SCPI command log filename') parser.add_argument( '--export-cal-data', action='store_true', help='Save corrections to numpy `savez` (*.pyz) data file') parser.add_argument('--outer-channel', type=int, help='channel with outer corrections') parser.add_argument('--outer-cal-group', help='cal group containing outer corrections') parser.add_argument('--inner-channel', type=int, help='channel with inner corrections') parser.add_argument('--inner-cal-group', help='cal group containing inner corrections') parser.add_argument('--filename', default='Port {port}.s2p', help="default: 'Port {port}.s2p'") parser.add_argument('ports', type=int, nargs='+', help='VNA ports to extract DUTs from') args = parser.parse_args() if not args.inner_channel and not args.inner_cal_group: print('error: must include inner source, either channel or cal group') parser.print_help() sys.exit(-1) if not args.outer_channel and not args.outer_cal_group: print('error: must include outer source, either channel or cal group') parser.print_help() sys.exit(-1) vna = Vna() try: if args.visa: vna.open(args.visa, args.address) else: vna.open_tcp(args.address, args.port) if args.timeout: vna.timeout_ms = args.timeout if vna.connected(): if args.log: vna.open_log(args.log) print_header(vna.log, 'R&S S2P Extractor', '1.0') vna.print_info() else: raise Exception('Could not connect to instrument') if args.outer_channel: outer_source = Source(Type.CHANNEL, args.outer_channel) else: outer_source = Source(Type.CAL_GROUP, args.outer_cal_group) if args.inner_channel: inner_source = Source(Type.CHANNEL, args.inner_channel) else: inner_source = Source(Type.CAL_GROUP, args.inner_cal_group) print(f"ports: {args.ports}") for port in args.ports: filename = args.filename.format(port=port) print(f' {filename}') calculate(vna, outer_source, inner_source, port, filename, args.export_cal_data) except Exception as err: parser.print_help() raise finally: if vna.connected(): vna.errors vna.clear_status() if vna.log: vna.close_log() if vna.connected(): vna.close()