def CheckActivateNotify(element, waitingtime, value, mailtype, sensor, sensorvalue): global AUTO_data # check if time between watering events is larger that the waiting time (minutes) print ' Previous action: ', AUTO_data[element][ "lastactiontime"], ' Now: ', datetime.now() timedifference = sensordbmod.timediffinminutes( AUTO_data[element]["lastactiontime"], datetime.now()) print 'Time interval between actions', timedifference, '. threshold', waitingtime logger.info('Time interval between Actions %d threshold %d', timedifference, waitingtime) if timedifference >= waitingtime: # sufficient time between actions print " Sufficient waiting time" logger.info('Sufficient waiting time') # action print "Implement Actuator Value ", value logger.info('Procedure to start actuator %s, for value = %s', element, value) isok = activateactuator(element, value) # invia mail, considered as info, not as alert if mailtype != "warningonly": textmessage = "INFO: " + sensor + " value " + str( sensorvalue ) + ", activating:" + element + " with Value " + str(value) emailmod.sendallmail("alert", textmessage) if isok: AUTO_data[element]["lastactiontime"] = datetime.now() AUTO_data[element]["actionvalue"] = value else: logger.info('Need to wait more time')
def CheckActivateNotify(element,waitingtime,value,mailtype,sensor,sensorvalue): global AUTO_data # check if time between watering events is larger that the waiting time (minutes) lastactiontime=statusdataDBmod.read_status_data(AUTO_data,element,"lastactiontime") print ' Previous action: ' , lastactiontime , ' Now: ', datetime.now() timedifference=sensordbmod.timediffinminutes(lastactiontime,datetime.now()) print 'Time interval between actions', timedifference ,'. threshold', waitingtime logger.info('Time interval between Actions %d threshold %d', timedifference,waitingtime) if timedifference>=waitingtime: # sufficient time between actions print " Sufficient waiting time" logger.info('Sufficient waiting time') # action print "Implement Actuator Value ", value logger.info('Procedure to start actuator %s, for value = %s', element, value) isok=activateactuator(element, value) # invia mail, considered as info, not as alert if mailtype!="warningonly": textmessage="INFO: " + sensor + " value " + str(sensorvalue) + ", activating:" + element + " with Value " + str(value) emailmod.sendallmail("alert", textmessage) if isok: statusdataDBmod.write_status_data(AUTO_data,element,"lastactiontime",datetime.now()) statusdataDBmod.write_status_data(AUTO_data,element,"actionvalue",value) else: logger.info('Need to wait more time')
def CheckActivateNotify(element,waitingtime,value,mailtype,sensor,sensorvalue): global AUTO_data # check if time between watering events is larger that the waiting time (minutes) lastactiontime=statusdataDBmod.read_status_data(AUTO_data,element,"lastactiontime") print(' Previous action: ' , lastactiontime , ' Now: ', datetime.utcnow()) timedifference=sensordbmod.timediffinminutes(lastactiontime,datetime.utcnow()) print('Time interval between actions', timedifference ,'. threshold', waitingtime) logger.info('Time interval between Actions %d threshold %d', timedifference,waitingtime) if timedifference>=waitingtime: # sufficient time between actions print(" Sufficient waiting time") logger.info('Sufficient waiting time') # action print("Implement Actuator Value ", value) logger.info('Procedure to start actuator %s, for value = %s', element, value) isok=activateactuator(element, value) # invia mail, considered as info, not as alert if (mailtype!="warningonly")and(mailtype!="none"): textmessage="INFO: " + sensor + " value " + str(sensorvalue) + ", activating:" + element + " with Value " + str(value) emailmod.sendallmail("alert", textmessage) if isok: statusdataDBmod.write_status_data(AUTO_data,element,"lastactiontime",datetime.utcnow()) statusdataDBmod.write_status_data(AUTO_data,element,"actionvalue",value) else: logger.info('Need to wait more time')
def autowateringexecute(refsensor, element): global AUTO_data sensor = autowateringdbmod.searchdata("element", element, "sensor") # check the sensor if refsensor == sensor: print "auto watering check -----------------------------------------> ", element logger.info('auto watering check --------------------------> %s', element) # check the watering mode modelist = ["None", "Full Auto", "Emergency Activation", "Alert Only"] workmode = checkworkmode(element) if not (sensor in sensordbmod.gettablelist()): print "Sensor does not exist ", sensor, ", element: ", element logger.error("Sensor does not exist %s , element: %s ", sensor, element) return "sensor not Exist" maxthreshold = hardwaremod.tonumber( autowateringdbmod.searchdata("element", element, "threshold")[1], 0) minthreshold = hardwaremod.tonumber( autowateringdbmod.searchdata("element", element, "threshold")[0], maxthreshold) # exit condition in case of data inconsistency if minthreshold >= maxthreshold: print "Data inconsistency , element: ", element logger.error("Data inconsistency , element: %s ", element) return "data inconsistency" now = datetime.now() nowtime = now.time() starttimeh = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "allowedperiod")[0].split(":")[0], 0) starttimem = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "allowedperiod")[0].split(":")[1], 0) endtimeh = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "allowedperiod")[1].split(":")[0], 1) endtimem = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "allowedperiod")[1].split(":")[1], 0) starttime = time(starttimeh, starttimem) endtime = time(endtimeh, endtimem) duration = 1000 * hardwaremod.toint( autowateringdbmod.searchdata("element", element, "wtstepsec"), 0) maxstepnumber = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "maxstepnumber"), 0) maxdays = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "maxdaysbetweencycles"), 0) waitingtime = hardwaremod.toint( autowateringdbmod.searchdata("element", element, "pausebetweenwtstepsmin"), 0) mailtype = autowateringdbmod.searchdata("element", element, "mailalerttype") minaccepted = hardwaremod.tonumber( autowateringdbmod.searchdata("element", element, "sensorminacceptedvalue"), 0.1) # ------------------------ Workmode split if workmode == "Full Auto": # block the wateringplan activation as by definition of "Full Auto" allowwateringplan[element] = False # check if inside the allowed time period print "full Auto Mode" logger.info('full auto mode --> %s', element) timeok = isNowInTimePeriod(starttime, endtime, nowtime) print "inside allowed time ", timeok, " starttime ", starttime, " endtime ", endtime logger.info('full auto mode') if timeok: logger.info('inside allowed time') belowthr, valid = checkminthreshold(sensor, minthreshold, minaccepted) if valid: if belowthr: status = "lowthreshold" logger.info('below threshold') # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") print ' Previous watering: ', lastwateringtime, ' Now: ', datetime.now( ) timedifference = sensordbmod.timediffinminutes( lastwateringtime, datetime.now()) print 'Time interval between watering steps', timedifference, '. threshold', waitingtime logger.info( 'Time interval between watering steps %d threshold %d', timedifference, waitingtime) if timedifference > waitingtime: print " Sufficient waiting time" logger.info('Sufficient waiting time') # activate watering in case the maxstepnumber is not exceeded watercounter = statusdataDBmod.read_status_data( AUTO_data, element, "watercounter") if maxstepnumber > watercounter: #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype != "warningonly": textmessage = "INFO: " + sensor + " value below the minimum threshold " + str( minthreshold ) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", watercounter + 1) statusdataDBmod.write_status_data( AUTO_data, element, "lastwateringtime", datetime.now()) else: # critical, sensor below minimum after all watering activations are done logger.info( 'Number of watering time per cycle has been exceeeded' ) # read hystory data and calculate the slope timelist = hardwaremod.gettimedata(sensor) cyclestartdate = statusdataDBmod.read_status_data( AUTO_data, element, "cyclestartdate") lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") startdate = cyclestartdate - timedelta( minutes=timelist[1]) enddate = lastwateringtime + timedelta( minutes=waitingtime) isslopeok = checkinclination( sensor, startdate, enddate ) # still to decide if use the enddate if isslopeok: # invia mail if couner alert is lower than 1 alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 1: textmessage = "WARNING: Please consider to increase the amount of water per cycle, the " + sensor + " value below the MINIMUM threshold " + str( minthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber ) + " times. System will automatically reset the watering cycle to allow more water" print textmessage #send alert mail notification emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # reset watering cycle status = "done" statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", -1) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "cyclestartdate", datetime.now()) else: # slope not OK, probable hardware problem alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 3: textmessage = "CRITICAL: Possible hardware problem, " + sensor + " value below the MINIMUM threshold " + str( minthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # update the status checkcounter = statusdataDBmod.read_status_data( AUTO_data, element, "checkcounter") statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", status) statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", checkcounter + 1) # RAMPUP case above threshold but below maxthreshold elif sensorreading( sensor ) < maxthreshold: # intermediate state where the sensor is above the minthreshold but lower than the max threshold # check the status of the automatic cycle cyclestatus = statusdataDBmod.read_status_data( AUTO_data, element, "cyclestatus") if cyclestatus != "done": status = "rampup" # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") if sensordbmod.timediffinminutes( lastwateringtime, datetime.now()) > waitingtime: watercounter = statusdataDBmod.read_status_data( AUTO_data, element, "watercounter") if maxstepnumber > watercounter: #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype != "warningonly": textmessage = "INFO: " + sensor + " value below the Maximum threshold " + str( maxthreshold ) + ", activating the watering :" + element emailmod.sendallmail( "alert", textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", watercounter + 1) statusdataDBmod.write_status_data( AUTO_data, element, "lastwateringtime", datetime.now()) else: # give up to reache the maximum threshold, proceed as done, send alert logger.info( 'Number of watering time per cycle has been exceeeded' ) # invia mail if couner alert is lower than 1 -------------- # only if the info is activated if mailtype != "warningonly": alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 2: textmessage = "INFO " + sensor + " value below the Maximum threshold " + str( maxthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # reset watering cycle status = "done" statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", -1) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "cyclestartdate", datetime.now()) # update the status checkcounter = statusdataDBmod.read_status_data( AUTO_data, element, "checkcounter") statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", status) statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", checkcounter + 1) else: # update the status, reset cycle statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", "done") statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) elif workmode == "Emergency Activation": # check if inside the allow time period logger.info('Emergency Mode') timeok = isNowInTimePeriod(starttime, endtime, nowtime) print "inside allowed time ", timeok, " starttime ", starttime, " endtime ", endtime if timeok: belowthr, valid = checkminthreshold(sensor, minthreshold, minaccepted) if valid: if belowthr: # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") if sensordbmod.timediffinminutes( lastwateringtime, datetime.now()) > waitingtime: # activate watering in case the maxstepnumber is not exceeded watercounter = statusdataDBmod.read_status_data( AUTO_data, element, "watercounter") if maxstepnumber > watercounter: #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype != "warningonly": textmessage = "INFO: " + sensor + " value below the minimum threshold " + str( minthreshold ) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", watercounter + 1) statusdataDBmod.write_status_data( AUTO_data, element, "lastwateringtime", datetime.now()) else: logger.info( 'Number of watering time per cycle has been exceeeded' ) # read hystory data and calculate the slope timelist = hardwaremod.gettimedata(sensor) cyclestartdate = statusdataDBmod.read_status_data( AUTO_data, element, "cyclestartdate") lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") startdate = cyclestartdate - timedelta( minutes=timelist[1]) enddate = lastwateringtime + timedelta( minutes=waitingtime) isslopeok = checkinclination( sensor, startdate, enddate) if isslopeok: # invia mail if couner alert is lower than 1 alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 1: textmessage = "WARNING: Please consider to increase the amount of water per cycle, the " + sensor + " value below the MINIMUM threshold " + str( minthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber ) + " times. System will automatically reset the watering cycle to allow more water" print textmessage #send alert mail notification alertcounter emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # reset watering cycle status = "done" statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", -1) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "cyclestartdate", datetime.now()) else: # slope not OK, probable hardware problem alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 3: textmessage = "CRITICAL: Possible hardware problem, " + sensor + " value below the MINIMUM threshold " + str( minthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # update the status checkcounter = statusdataDBmod.read_status_data( AUTO_data, element, "checkcounter") statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", "lowthreshold") statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", checkcounter + 1) else: # update the status statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", "done") statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) elif workmode == "under MIN over MAX": logger.info('under MIN over MAX') # normally watering plan is allowed unless over MAX threshold allowwateringplan[element] = True # check if inside the allow time period timeok = isNowInTimePeriod(starttime, endtime, nowtime) print "inside allowed time ", timeok, " starttime ", starttime, " endtime ", endtime if timeok: logger.info('Insede operative time') belowthr, valid = checkminthreshold(sensor, minthreshold, minaccepted) if valid: logger.info('valid sensor reading') if belowthr: logger.info('sensor reading below threshold') # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") if sensordbmod.timediffinminutes( lastwateringtime, datetime.now()) > waitingtime: # activate watering in case the maxstepnumber is not exceeded watercounter = statusdataDBmod.read_status_data( AUTO_data, element, "watercounter") if maxstepnumber > watercounter: logger.info('water Count not exceeded') #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype != "warningonly": textmessage = "INFO: " + sensor + " value below the minimum threshold " + str( minthreshold ) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", watercounter + 1) statusdataDBmod.write_status_data( AUTO_data, element, "lastwateringtime", datetime.now()) else: logger.info( 'Number of watering time per cycle has been exceeeded' ) # read hystory data and calculate the slope timelist = hardwaremod.gettimedata(sensor) cyclestartdate = statusdataDBmod.read_status_data( AUTO_data, element, "cyclestartdate") lastwateringtime = statusdataDBmod.read_status_data( AUTO_data, element, "lastwateringtime") startdate = cyclestartdate - timedelta( minutes=timelist[1]) enddate = lastwateringtime + timedelta( minutes=waitingtime) isslopeok = checkinclination( sensor, startdate, enddate) if isslopeok: # invia mail if couner alert is lower than 1 alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 1: textmessage = "WARNING: Please consider to increase the amount of water per cycle, the " + sensor + " value below the MINIMUM threshold " + str( minthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber ) + " times. System will automatically reset the watering cycle to allow more water" print textmessage #send alert mail notification emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # reset watering cycle status = "done" statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", -1) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "cyclestartdate", datetime.now()) else: # slope not OK, probable hardware problem alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 3: textmessage = "CRITICAL: Possible hardware problem, " + sensor + " value below the MINIMUM threshold " + str( minthreshold ) + " still after activating the watering :" + element + " for " + str( maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail( "alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # update the status checkcounter = statusdataDBmod.read_status_data( AUTO_data, element, "checkcounter") statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", "lowthreshold") statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", checkcounter + 1) else: # above minimum threshold logger.info('sensor reading above min threshold') # update the status statusdataDBmod.write_status_data( AUTO_data, element, "cyclestatus", "done") statusdataDBmod.write_status_data( AUTO_data, element, "checkcounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", 0) if sensorreading(sensor) > maxthreshold: logger.info( 'sensor reading above MAX threshold, deactivate scheduled irrigation' ) # do not activate the irrigation scheduled in the time plan allowwateringplan[element] = False elif workmode == "Alert Only": belowthr, valid = checkminthreshold(sensor, minthreshold, minaccepted) if valid: if belowthr: # invia mail if couter alert is lower than alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 2: textmessage = "WARNING " + sensor + " value below the minimum threshold " + str( minthreshold) + " watering system: " + element print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) # update the status checkcounter = statusdataDBmod.read_status_data( AUTO_data, element, "checkcounter") statusdataDBmod.write_status_data(AUTO_data, element, "cyclestatus", "lowthreshold") statusdataDBmod.write_status_data(AUTO_data, element, "checkcounter", checkcounter + 1) else: # update the status statusdataDBmod.write_status_data(AUTO_data, element, "cyclestatus", "done") statusdataDBmod.write_status_data(AUTO_data, element, "checkcounter", 0) statusdataDBmod.write_status_data(AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data(AUTO_data, element, "alertcounter", 0) else: # None case print "No Action required, workmode set to None, element: ", element logger.info( "No Action required, workmode set to None, element: %s ", element) cyclestatus = statusdataDBmod.read_status_data(AUTO_data, element, "cyclestatus") if cyclestatus == "lowthreshold": checkcounter = statusdataDBmod.read_status_data( AUTO_data, element, "checkcounter") if checkcounter == 1: statusdataDBmod.write_status_data(AUTO_data, element, "cyclestartdate", datetime.now()) # implment alert message for the cycle exceeding days, and reset the cycle if workmode != "None": cyclestartdate = statusdataDBmod.read_status_data( AUTO_data, element, "cyclestartdate") timedeltadays = sensordbmod.timediffdays(datetime.now(), cyclestartdate) if (timedeltadays > maxdays ): #the upper limit is set in case of abrupt time change textmessage = "WARNING " + sensor + " watering cycle is taking too many days, watering system: " + element + ". Reset watering cycle" print textmessage # in case of full Auto, activate pump for minimum pulse period if workmode == "Full Auto": if ( timedeltadays < maxdays + 2 ): #the upper limit is set in case of abrupt time change textmessage = "WARNING " + sensor + " watering cycle is taking too many days, watering system: " + element + ". Activate Min pulse + Reset watering cycle" activatewater(element, duration) #send alert mail notification if mailtype != "warningonly": emailmod.sendallmail("alert", textmessage) logger.error(textmessage) logger.error("Cycle started %s, Now is %s ", cyclestartdate.strftime("%Y-%m-%d %H:%M:%S"), datetime.now().strftime("%Y-%m-%d %H:%M:%S")) # reset cycle statusdataDBmod.write_status_data(AUTO_data, element, "cyclestatus", "done") statusdataDBmod.write_status_data(AUTO_data, element, "checkcounter", 0) statusdataDBmod.write_status_data(AUTO_data, element, "watercounter", 0) statusdataDBmod.write_status_data(AUTO_data, element, "alertcounter", 0) statusdataDBmod.write_status_data(AUTO_data, element, "cyclestartdate", datetime.now()) # implment Critical alert message in case the threshold is below the 0.5 of the minimum if workmode != "None": belowthr, valid = checkminthreshold(sensor, minthreshold * 0.5, minaccepted) if valid: if belowthr: logger.info( 'sensor %s below half of the actual set threshold', sensor) textmessage = "CRITICAL: Plant is dying, " + sensor + " reading below half of the minimum threshold, need to check the " + element print textmessage #send alert mail notification alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 5: emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data( AUTO_data, element, "alertcounter", alertcounter + 1) else: logger.info('sensor %s below valid data', sensor) textmessage = "WARNING: " + sensor + " below valid data range, need to check sensor" print textmessage #send alert mail notification alertcounter = statusdataDBmod.read_status_data( AUTO_data, element, "alertcounter") if alertcounter < 3: emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data, element, "alertcounter", alertcounter + 1) return
def autowateringexecute(refsensor,element): global AUTO_data sensor=autowateringdbmod.searchdata("element",element,"sensor") # check the sensor if refsensor==sensor: print "auto watering check -----------------------------------------> ", element logger.info('auto watering check --------------------------> %s', element) # check the watering mode modelist=["None", "Full Auto" , "Emergency Activation" , "Alert Only"] workmode=checkworkmode(element) if not(sensor in sensordbmod.gettablelist()): print "Sensor does not exist " ,sensor , ", element: " , element logger.error("Sensor does not exist %s , element: %s " ,sensor, element) return "sensor not Exist" maxthreshold=hardwaremod.tonumber(autowateringdbmod.searchdata("element",element,"threshold")[1],0) minthreshold=hardwaremod.tonumber(autowateringdbmod.searchdata("element",element,"threshold")[0],maxthreshold) # exit condition in case of data inconsistency if minthreshold>=maxthreshold: print "Data inconsistency , element: " , element logger.error("Data inconsistency , element: %s " , element) return "data inconsistency" now = datetime.now() nowtime = now.time() starttimeh=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"allowedperiod")[0].split(":")[0],0) starttimem=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"allowedperiod")[0].split(":")[1],0) endtimeh=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"allowedperiod")[1].split(":")[0],1) endtimem=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"allowedperiod")[1].split(":")[1],0) starttime=time(starttimeh,starttimem) endtime=time(endtimeh,endtimem) duration=1000*hardwaremod.toint(autowateringdbmod.searchdata("element",element,"wtstepsec"),0) maxstepnumber=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"maxstepnumber"),0) maxdays=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"maxdaysbetweencycles"),0) waitingtime=hardwaremod.toint(autowateringdbmod.searchdata("element",element,"pausebetweenwtstepsmin"),0) mailtype=autowateringdbmod.searchdata("element",element,"mailalerttype") minaccepted=hardwaremod.tonumber(autowateringdbmod.searchdata("element",element,"sensorminacceptedvalue"),0.1) # ------------------------ Workmode split if workmode=="Full Auto": # block the wateringplan activation as by definition of "Full Auto" allowwateringplan[element]=False # check if inside the allowed time period print "full Auto Mode" logger.info('full auto mode --> %s', element) timeok=isNowInTimePeriod(starttime, endtime, nowtime) print "inside allowed time ", timeok , " starttime ", starttime , " endtime ", endtime logger.info('full auto mode') if timeok: logger.info('inside allowed time') belowthr,valid=checkminthreshold(sensor,minthreshold,minaccepted) if valid: if belowthr: status="lowthreshold" logger.info('below threshold') # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") print ' Previous watering: ' , lastwateringtime , ' Now: ', datetime.now() timedifference=sensordbmod.timediffinminutes(lastwateringtime,datetime.now()) print 'Time interval between watering steps', timedifference ,'. threshold', waitingtime logger.info('Time interval between watering steps %d threshold %d', timedifference,waitingtime) if timedifference>waitingtime: print " Sufficient waiting time" logger.info('Sufficient waiting time') # activate watering in case the maxstepnumber is not exceeded watercounter=statusdataDBmod.read_status_data(AUTO_data,element,"watercounter") if maxstepnumber>watercounter: #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype!="warningonly": textmessage="INFO: " + sensor + " value below the minimum threshold " + str(minthreshold) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",watercounter+1) statusdataDBmod.write_status_data(AUTO_data,element,"lastwateringtime",datetime.now()) else: # critical, sensor below minimum after all watering activations are done logger.info('Number of watering time per cycle has been exceeeded') # read hystory data and calculate the slope timelist=hardwaremod.gettimedata(sensor) cyclestartdate=statusdataDBmod.read_status_data(AUTO_data,element,"cyclestartdate") lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") startdate=cyclestartdate - timedelta(minutes=timelist[1]) enddate=lastwateringtime + timedelta(minutes=waitingtime) isslopeok=checkinclination(sensor,startdate,enddate) # still to decide if use the enddate if isslopeok: # invia mail if couner alert is lower than 1 alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<1: textmessage="WARNING: Please consider to increase the amount of water per cycle, the "+ sensor + " value below the MINIMUM threshold " + str(minthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times. System will automatically reset the watering cycle to allow more water" print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # reset watering cycle status="done" statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",-1) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"cyclestartdate",datetime.now()) else: # slope not OK, probable hardware problem alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<3: textmessage="CRITICAL: Possible hardware problem, "+ sensor + " value below the MINIMUM threshold " + str(minthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # update the status checkcounter=statusdataDBmod.read_status_data(AUTO_data,element,"checkcounter") statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus",status) statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",checkcounter+1) # RAMPUP case above threshold but below maxthreshold elif sensorreading(sensor)<maxthreshold: # intermediate state where the sensor is above the minthreshold but lower than the max threshold # check the status of the automatic cycle cyclestatus=statusdataDBmod.read_status_data(AUTO_data,element,"cyclestatus") if cyclestatus!="done": status="rampup" # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") if sensordbmod.timediffinminutes(lastwateringtime,datetime.now())>waitingtime: watercounter=statusdataDBmod.read_status_data(AUTO_data,element,"watercounter") if maxstepnumber>watercounter: #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype!="warningonly": textmessage="INFO: " + sensor + " value below the Maximum threshold " + str(maxthreshold) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",watercounter+1) statusdataDBmod.write_status_data(AUTO_data,element,"lastwateringtime",datetime.now()) else: # give up to reache the maximum threshold, proceed as done, send alert logger.info('Number of watering time per cycle has been exceeeded') # invia mail if couner alert is lower than 1 -------------- # only if the info is activated if mailtype!="warningonly": alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<2: textmessage="INFO "+ sensor + " value below the Maximum threshold " + str(maxthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # reset watering cycle status="done" statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",-1) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"cyclestartdate",datetime.now()) # update the status checkcounter=statusdataDBmod.read_status_data(AUTO_data,element,"checkcounter") statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus",status) statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",checkcounter+1) else: # update the status, reset cycle statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","done") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) elif workmode=="Emergency Activation": # check if inside the allow time period logger.info('Emergency Mode') timeok=isNowInTimePeriod(starttime, endtime, nowtime) print "inside allowed time ", timeok , " starttime ", starttime , " endtime ", endtime if timeok: belowthr,valid=checkminthreshold(sensor,minthreshold,minaccepted) if valid: if belowthr: # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") if sensordbmod.timediffinminutes(lastwateringtime,datetime.now())>waitingtime: # activate watering in case the maxstepnumber is not exceeded watercounter=statusdataDBmod.read_status_data(AUTO_data,element,"watercounter") if maxstepnumber>watercounter: #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype!="warningonly": textmessage="INFO: " + sensor + " value below the minimum threshold " + str(minthreshold) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",watercounter+1) statusdataDBmod.write_status_data(AUTO_data,element,"lastwateringtime",datetime.now()) else: logger.info('Number of watering time per cycle has been exceeeded') # read hystory data and calculate the slope timelist=hardwaremod.gettimedata(sensor) cyclestartdate=statusdataDBmod.read_status_data(AUTO_data,element,"cyclestartdate") lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") startdate=cyclestartdate - timedelta(minutes=timelist[1]) enddate=lastwateringtime + timedelta(minutes=waitingtime) isslopeok=checkinclination(sensor,startdate,enddate) if isslopeok: # invia mail if couner alert is lower than 1 alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<1: textmessage="WARNING: Please consider to increase the amount of water per cycle, the "+ sensor + " value below the MINIMUM threshold " + str(minthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times. System will automatically reset the watering cycle to allow more water" print textmessage #send alert mail notification alertcounter emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # reset watering cycle status="done" statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",-1) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"cyclestartdate",datetime.now()) else: # slope not OK, probable hardware problem alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<3: textmessage="CRITICAL: Possible hardware problem, "+ sensor + " value below the MINIMUM threshold " + str(minthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # update the status checkcounter=statusdataDBmod.read_status_data(AUTO_data,element,"checkcounter") statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","lowthreshold") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",checkcounter+1) else: # update the status statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","done") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) elif workmode=="under MIN over MAX": logger.info('under MIN over MAX') # normally watering plan is allowed unless over MAX threshold allowwateringplan[element]=True # check if inside the allow time period timeok=isNowInTimePeriod(starttime, endtime, nowtime) print "inside allowed time ", timeok , " starttime ", starttime , " endtime ", endtime if timeok: logger.info('Insede operative time') belowthr,valid=checkminthreshold(sensor,minthreshold,minaccepted) if valid: logger.info('valid sensor reading') if belowthr: logger.info('sensor reading below threshold') # wait to seek a more stable reading of hygrometer # check if time between watering events is larger that the waiting time (minutes) lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") if sensordbmod.timediffinminutes(lastwateringtime,datetime.now())>waitingtime: # activate watering in case the maxstepnumber is not exceeded watercounter=statusdataDBmod.read_status_data(AUTO_data,element,"watercounter") if maxstepnumber>watercounter: logger.info('water Count not exceeded') #activate pump activatewater(element, duration) # invia mail, considered as info, not as alert if mailtype!="warningonly": textmessage="INFO: " + sensor + " value below the minimum threshold " + str(minthreshold) + ", activating the watering :" + element emailmod.sendallmail("alert", textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",watercounter+1) statusdataDBmod.write_status_data(AUTO_data,element,"lastwateringtime",datetime.now()) else: logger.info('Number of watering time per cycle has been exceeeded') # read hystory data and calculate the slope timelist=hardwaremod.gettimedata(sensor) cyclestartdate=statusdataDBmod.read_status_data(AUTO_data,element,"cyclestartdate") lastwateringtime=statusdataDBmod.read_status_data(AUTO_data,element,"lastwateringtime") startdate=cyclestartdate - timedelta(minutes=timelist[1]) enddate=lastwateringtime + timedelta(minutes=waitingtime) isslopeok=checkinclination(sensor,startdate,enddate) if isslopeok: # invia mail if couner alert is lower than 1 alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<1: textmessage="WARNING: Please consider to increase the amount of water per cycle, the "+ sensor + " value below the MINIMUM threshold " + str(minthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times. System will automatically reset the watering cycle to allow more water" print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # reset watering cycle status="done" statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",-1) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"cyclestartdate",datetime.now()) else: # slope not OK, probable hardware problem alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<3: textmessage="CRITICAL: Possible hardware problem, "+ sensor + " value below the MINIMUM threshold " + str(minthreshold) + " still after activating the watering :" + element + " for " + str(maxstepnumber) + " times" print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # update the status checkcounter=statusdataDBmod.read_status_data(AUTO_data,element,"checkcounter") statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","lowthreshold") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",checkcounter+1) else: # above minimum threshold logger.info('sensor reading above min threshold') # update the status statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","done") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) if sensorreading(sensor)>maxthreshold: logger.info('sensor reading above MAX threshold, deactivate scheduled irrigation') # do not activate the irrigation scheduled in the time plan allowwateringplan[element]=False elif workmode=="Alert Only": belowthr,valid=checkminthreshold(sensor,minthreshold,minaccepted) if valid: if belowthr: # invia mail if couter alert is lower than alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<2: textmessage="WARNING "+ sensor + " value below the minimum threshold " + str(minthreshold) + " watering system: " + element print textmessage #send alert mail notification emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) # update the status checkcounter=statusdataDBmod.read_status_data(AUTO_data,element,"checkcounter") statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","lowthreshold") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",checkcounter+1) else: # update the status statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","done") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) else: # None case print "No Action required, workmode set to None, element: " , element logger.info("No Action required, workmode set to None, element: %s " , element) cyclestatus=statusdataDBmod.read_status_data(AUTO_data,element,"cyclestatus") if cyclestatus=="lowthreshold": checkcounter=statusdataDBmod.read_status_data(AUTO_data,element,"checkcounter") if checkcounter==1: statusdataDBmod.write_status_data(AUTO_data,element,"cyclestartdate",datetime.now()) # implment alert message for the cycle exceeding days, and reset the cycle if workmode!="None": cyclestartdate=statusdataDBmod.read_status_data(AUTO_data,element,"cyclestartdate") timedeltadays=sensordbmod.timediffdays(datetime.now(),cyclestartdate) if (timedeltadays > maxdays): #the upper limit is set in case of abrupt time change textmessage="WARNING "+ sensor + " watering cycle is taking too many days, watering system: " + element + ". Reset watering cycle" print textmessage # in case of full Auto, activate pump for minimum pulse period if workmode=="Full Auto": if (timedeltadays < maxdays+2): #the upper limit is set in case of abrupt time change textmessage="WARNING "+ sensor + " watering cycle is taking too many days, watering system: " + element + ". Activate Min pulse + Reset watering cycle" activatewater(element, duration) #send alert mail notification if mailtype!="warningonly": emailmod.sendallmail("alert", textmessage) logger.error(textmessage) logger.error("Cycle started %s, Now is %s ", cyclestartdate.strftime("%Y-%m-%d %H:%M:%S"), datetime.now().strftime("%Y-%m-%d %H:%M:%S")) # reset cycle statusdataDBmod.write_status_data(AUTO_data,element,"cyclestatus","done") statusdataDBmod.write_status_data(AUTO_data,element,"checkcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"watercounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",0) statusdataDBmod.write_status_data(AUTO_data,element,"cyclestartdate",datetime.now()) # implment Critical alert message in case the threshold is below the 0.5 of the minimum if workmode!="None": belowthr,valid=checkminthreshold(sensor,minthreshold*0.5,minaccepted) if valid: if belowthr: logger.info('sensor %s below half of the actual set threshold', sensor) textmessage="CRITICAL: Plant is dying, "+ sensor + " reading below half of the minimum threshold, need to check the " + element print textmessage #send alert mail notification alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<5: emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) else: logger.info('sensor %s below valid data', sensor) textmessage="WARNING: "+ sensor + " below valid data range, need to check sensor" print textmessage #send alert mail notification alertcounter=statusdataDBmod.read_status_data(AUTO_data,element,"alertcounter") if alertcounter<3: emailmod.sendallmail("alert", textmessage) logger.error(textmessage) statusdataDBmod.write_status_data(AUTO_data,element,"alertcounter",alertcounter+1) return