示例#1
0
    def setup_Network_individual_offdesign(self):
        """Set up network for individual offdesign tests."""
        self.nw = Network(['H2O'], T_unit='C', p_unit='bar', v_unit='m3 / s')

        so = Source('source')
        sp = Splitter('splitter', num_out=2)
        self.pump1 = Pump('pump 1')
        self.sc1 = SolarCollector('collector field 1')
        v1 = Valve('valve1')
        self.pump2 = Pump('pump 2')
        self.sc2 = SolarCollector('collector field 2')
        v2 = Valve('valve2')
        me = Merge('merge', num_in=2)
        si = Sink('sink')

        self.pump1.set_attr(eta_s=0.8,
                            design=['eta_s'],
                            offdesign=['eta_s_char'])
        self.pump2.set_attr(eta_s=0.8,
                            design=['eta_s'],
                            offdesign=['eta_s_char'])
        self.sc1.set_attr(pr=0.95,
                          lkf_lin=3.33,
                          lkf_quad=0.011,
                          A=1252,
                          E=700,
                          Tamb=20,
                          eta_opt=0.92,
                          design=['pr'],
                          offdesign=['zeta'])
        self.sc2.set_attr(pr=0.95,
                          lkf_lin=3.5,
                          lkf_quad=0.011,
                          A=700,
                          E=800,
                          Tamb=20,
                          eta_opt=0.92,
                          design=['pr'],
                          offdesign=['zeta'])

        fl = {'H2O': 1}
        inlet = Connection(so, 'out1', sp, 'in1', T=50, p=3, fluid=fl)
        outlet = Connection(me, 'out1', si, 'in1', p=3)

        self.sp_p1 = Connection(sp, 'out1', self.pump1, 'in1')
        self.p1_sc1 = Connection(self.pump1, 'out1', self.sc1, 'in1')
        self.sc1_v1 = Connection(self.sc1, 'out1', v1, 'in1', p=3.1, T=90)
        v1_me = Connection(v1, 'out1', me, 'in1')

        self.sp_p2 = Connection(sp, 'out2', self.pump2, 'in1')
        self.p2_sc2 = Connection(self.pump2, 'out1', self.sc2, 'in1')
        self.sc2_v2 = Connection(self.sc2, 'out1', v2, 'in1', p=3.1, m=0.1)
        v2_me = Connection(v2, 'out1', me, 'in2')

        self.nw.add_conns(inlet, outlet, self.sp_p1, self.p1_sc1, self.sc1_v1,
                          v1_me, self.sp_p2, self.p2_sc2, self.sc2_v2, v2_me)
示例#2
0
文件: conf.py 项目: fwitte/fluprodia
def run_simple_heat_pump_model():
    nw = Network(['NH3'], T_unit='C', p_unit='bar', h_unit='kJ / kg')
    nw.set_attr(iterinfo=False)
    cp = Compressor('compressor')
    cc = CycleCloser('cycle_closer')
    cd = HeatExchangerSimple('condenser')
    va = Valve('expansion valve')
    ev = HeatExchangerSimple('evaporator')

    cc_cd = Connection(cc, 'out1', cd, 'in1')
    cd_va = Connection(cd, 'out1', va, 'in1')
    va_ev = Connection(va, 'out1', ev, 'in1')
    ev_cp = Connection(ev, 'out1', cp, 'in1')
    cp_cc = Connection(cp, 'out1', cc, 'in1')

    nw.add_conns(cc_cd, cd_va, va_ev, ev_cp, cp_cc)

    cd.set_attr(pr=0.95, Q=-1e6)
    ev.set_attr(pr=0.9)
    cp.set_attr(eta_s=0.9)

    cc_cd.set_attr(fluid={'NH3': 1})
    cd_va.set_attr(Td_bp=-5, T=85)
    ev_cp.set_attr(Td_bp=5, T=15)
    nw.solve('design')

    result_dict = {}
    result_dict.update({
        cp.label: cp.get_plotting_data()[1]
        for cp in nw.comps.index if cp.get_plotting_data() is not None
    })

    return result_dict
示例#3
0
    def create_comps(self):

        self.comps['splitter'] = Splitter(self.label + '_splitter')
        self.comps['merge'] = Merge(self.label + '_merge')

        for i in range(self.num_branch):
            j = str(i)
            self.comps['valve_' + j] = Valve(self.label + '_valve_' + j)
示例#4
0
    def test_Valve(self):
        """Test component properties of valves."""
        instance = Valve('valve')
        self.setup_piping_network(instance)

        # parameter specification
        self.c1.set_attr(fluid={'CH4': 1}, m=10, p=10, T=120)
        self.c2.set_attr(p=1)

        # test variable pressure ration
        instance.set_attr(pr='var')
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)
        pr = round(self.c2.p.val_SI / self.c1.p.val_SI, 2)
        msg = ('Value of pressure ratio must be ' + str(pr) + ', is ' +
               str(round(instance.pr.val, 2)) + '.')
        assert pr == round(instance.pr.val, 2), msg

        # test variable zeta value
        zeta = round(instance.zeta.val, 0)
        instance.set_attr(zeta='var', pr=None)
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)
        msg = ('Value of dimension independent zeta value must be ' +
               str(zeta) + ', is ' + str(round(instance.zeta.val, 0)) + '.')
        assert zeta == round(instance.zeta.val, 0), msg

        # dp char
        x = np.array([8, 9, 10, 11, 12])
        y = np.array([5, 8, 9, 9.5, 9.6]) * 1e5
        dp_char = CharLine(x, y)
        instance.set_attr(zeta=None,
                          dp_char={
                              'char_func': dp_char,
                              'is_set': True
                          })
        m = 11
        self.c1.set_attr(m=m)
        self.c2.set_attr(p=np.nan)
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)
        self.nw.print_results()
        dp = round(-dp_char.evaluate(m), 0)
        dp_act = round(self.c2.p.val_SI - self.c1.p.val_SI)
        msg = ('The pressure drop at the valve should be ' + str(dp) + ' but '
               'is ' + str(dp_act) + '.')
        assert dp == dp_act, msg
示例#5
0
    def create_comps(self):

        for i in range(self.num_consumer - 1):
            j = str(i)
            self.comps['feed_' + j] = Pipe(self.label + '_pipe feed_' + j)
            self.comps['return_' + j] = Pipe(self.label + '_pipe return_' + j)

        for i in range(self.num_consumer):
            j = str(i)
            self.comps['splitter_' + j] = Splitter(self.label + '_splitter_' +
                                                   j)
            self.comps['merge_' + j] = Merge(self.label + '_merge_' + j)
            self.comps['consumer_' + j] = HeatExchangerSimple(self.label +
                                                              '_consumer_' + j)
            self.comps['valve_' + j] = Valve(self.label + '_valve_' + j)
示例#6
0
    def setup(self):
        """Set up simple refrigerator."""
        self.Tamb = 20
        self.pamb = 1
        fluids = ['R134a']
        self.nw = Network(fluids=fluids)
        self.nw.set_attr(p_unit='bar', T_unit='C', h_unit='kJ / kg')

        # create components
        va = Valve('expansion valve')
        cp = Compressor('compressor')
        cond = HeatExchangerSimple('condenser')
        eva = HeatExchangerSimple('evaporator')
        cc = CycleCloser('cycle closer')

        # create busses
        # power output bus
        self.power = Bus('power input')
        self.power.add_comps({'comp': cp, 'char': 1, 'base': 'bus'})
        # cooling bus
        self.cool = Bus('heat from fridge')
        self.cool.add_comps({'comp': eva})
        # heat input bus
        self.heat = Bus('heat to ambient')
        self.heat.add_comps({'comp': cond})
        self.nw.add_busses(self.power, self.cool, self.heat)

        # create connections
        cc_cp = Connection(cc, 'out1', cp, 'in1', label='from eva')
        cp_cond = Connection(cp, 'out1', cond, 'in1', label='to cond')
        cond_va = Connection(cond, 'out1', va, 'in1', label='from cond')
        va_eva = Connection(va, 'out1', eva, 'in1', label='to eva')
        eva_cc = Connection(eva, 'out1', cc, 'in1')
        self.nw.add_conns(cc_cp, cp_cond, cond_va, va_eva, eva_cc)

        # component parameters
        cp.set_attr(eta_s=0.9)
        cond.set_attr(pr=0.97)
        eva.set_attr(pr=0.96)

        # connection parameters
        cc_cp.set_attr(m=1, x=1, T=-25, fluid={'R134a': 1})
        cond_va.set_attr(x=0, T=self.Tamb + 1)

        # solve network
        self.nw.solve('design')
        convergence_check(self.nw.lin_dep)
示例#7
0
amb_out1 = Sink('sink ambient 1')
amb_out2 = Sink('sink ambient 2')

# ambient air system
sp = Splitter('splitter')
fan = Compressor('fan')

# consumer system

cd = Condenser('condenser')
dhp = Pump('district heating pump')
cons = HeatExchangerSimple('consumer')

# evaporator system

ves = Valve('valve')
dr = Drum('drum')
ev = HeatExchanger('evaporator')
su = HeatExchanger('superheater')
erp = Pump('evaporator reciculation pump')

# compressor-system

cp1 = Compressor('compressor 1')
cp2 = Compressor('compressor 2')
ic = HeatExchanger('intercooler')

# %% connections

# consumer system
    def setup(self):
        """
        Full model validation of SEGS model in TESPy vs. EBSILON.

        Find original models at https://github.com/fwitte/SEGS_exergy.
        """
        # specification of ambient state
        self.pamb = 1.013
        self.Tamb = 25

        # setting up network
        self.nw = Network(fluids=['water', 'INCOMP::TVP1', 'air'])
        self.nw.set_attr(T_unit='C',
                         p_unit='bar',
                         h_unit='kJ / kg',
                         m_unit='kg / s',
                         s_unit="kJ / kgK")

        # components definition
        air_in = Source('Ambient air source', fkt_group='CW')
        air_out = Sink('Ambient air sink', fkt_group='CW')

        closer_pt = CycleCloser('Cycle closer pt', fkt_group='SF')
        pt = ParabolicTrough('Parabolic trough', fkt_group='SF')
        ptpump = Pump('HTF pump', fkt_group='SF')

        closer = CycleCloser('Cycle closer power cycle', fkt_group='SG')

        eco = HeatExchanger('Economizer', fkt_group='SG')
        eva = HeatExchanger('Evaporator', fkt_group='SG')
        sup = HeatExchanger('Superheater', fkt_group='SG')
        drum = Drum('Drum', fkt_group='SG')

        reh = HeatExchanger('Reheater', fkt_group='RH')

        hpt1 = Turbine('HP turbine 1', fkt_group='HPT')
        hpt2 = Turbine('HP turbine 2', fkt_group='HPT')
        lpt1 = Turbine('LP turbine 1', fkt_group='LPT')
        lpt2 = Turbine('LP turbine 2', fkt_group='LPT')
        lpt3 = Turbine('LP turbine 3', fkt_group='LPT')
        lpt4 = Turbine('LP turbine 4', fkt_group='LPT')
        lpt5 = Turbine('LP turbine 5', fkt_group='LPT')

        cond = Condenser('Condenser', fkt_group='CW')
        condpump = Pump('Condenser pump', fkt_group='CW')
        fwt = Merge('Feedwater tank', num_in=3, fkt_group='LPP')
        fwp = Pump('Feedwater pump', fkt_group='FWP')
        cwp = Pump('Cooling water pump', fkt_group='CW')
        closer_cw = CycleCloser('Cycle closer cw', fkt_group='CW')
        ct = HeatExchanger('Cooling tower', fkt_group='CW')
        fan = Compressor('Cooling tower fan', fkt_group='CW')

        sp1 = Splitter('Splitter 1', fkt_group='HPT')
        sp2 = Splitter('Splitter 2', fkt_group='HPT')
        sp3 = Splitter('Splitter 3', fkt_group='LPT')
        sp4 = Splitter('Splitter 4', fkt_group='LPT')
        sp5 = Splitter('Splitter 5', fkt_group='LPT')
        sp6 = Splitter('Splitter 6', fkt_group='LPT')
        sp7 = Splitter('Splitter 7', fkt_group='SF')

        m1 = Merge('Merge 1', fkt_group='CW')
        m2 = Merge('Merge 2', fkt_group='HPP')
        m3 = Merge('Merge 3', fkt_group='LPP')
        m4 = Merge('Merge 4', fkt_group='LPP')
        m5 = Merge('Merge 5', fkt_group='SF')

        v1 = Valve('Valve 1', fkt_group='HPP')
        v2 = Valve('Valve 2', fkt_group='HPP')
        v3 = Valve('Valve 3', fkt_group='LPP')
        v4 = Valve('Valve 4', fkt_group='LPP')
        v5 = Valve('Valve 5', fkt_group='LPP')

        hppre1 = Condenser('High pressure preheater 1', fkt_group='HPP')
        hppre2 = Condenser('High pressure preheater 2', fkt_group='HPP')
        hppre1_sub = HeatExchanger('High pressure preheater 1 subcooling',
                                   fkt_group='HPP')
        hppre2_sub = HeatExchanger('High pressure preheater 2 subcooling',
                                   fkt_group='HPP')

        lppre1 = Condenser('Low pressure preheater 1', fkt_group='LPP')
        lppre2 = Condenser('Low pressure preheater 2', fkt_group='LPP')
        lppre3 = Condenser('Low pressure preheater 3', fkt_group='LPP')
        lppre1_sub = HeatExchanger('Low pressure preheater 1 subcooling',
                                   fkt_group='LPP')
        lppre2_sub = HeatExchanger('Low pressure preheater 2 subcooling',
                                   fkt_group='LPP')
        lppre3_sub = HeatExchanger('Low pressure preheater 3 subcooling',
                                   fkt_group='LPP')

        # connections definition
        # power cycle
        c1 = Connection(sup, 'out2', closer, 'in1', label='1')
        c2 = Connection(closer, 'out1', hpt1, 'in1', label='2')
        c3 = Connection(hpt1, 'out1', sp1, 'in1', label='3')
        c4 = Connection(sp1, 'out1', hpt2, 'in1', label='4')
        c5 = Connection(hpt2, 'out1', sp2, 'in1', label='5')
        c6 = Connection(sp2, 'out1', reh, 'in2', label='6')
        c7 = Connection(reh, 'out2', lpt1, 'in1', label='7')
        c8 = Connection(lpt1, 'out1', sp3, 'in1', label='8')
        c9 = Connection(sp3, 'out1', lpt2, 'in1', label='9')
        c10 = Connection(lpt2, 'out1', sp4, 'in1', label='10')
        c11 = Connection(sp4, 'out1', lpt3, 'in1', label='11')
        c12 = Connection(lpt3, 'out1', sp5, 'in1', label='12')
        c13 = Connection(sp5, 'out1', lpt4, 'in1', label='13')
        c14 = Connection(lpt4, 'out1', sp6, 'in1', label='14')
        c15 = Connection(sp6, 'out1', lpt5, 'in1', label='15')
        c16 = Connection(lpt5, 'out1', m1, 'in1', label='16')
        c17 = Connection(m1, 'out1', cond, 'in1', label='17')
        c18 = Connection(cond, 'out1', condpump, 'in1', label='18')
        c19 = Connection(condpump, 'out1', lppre1, 'in2', label='19')
        # c19 = Connection(condpump, 'out1', lppre1_sub, 'in2', label='19')
        # c20 = Connection(lppre1_sub, 'out2', lppre1, 'in2', label='20')
        c21 = Connection(lppre1, 'out2', lppre2, 'in2', label='21')
        # c21 = Connection(lppre1, 'out2', lppre2_sub, 'in2', label='21')
        # c22 = Connection(lppre2_sub, 'out2', lppre2, 'in2', label='22')
        c23 = Connection(lppre2, 'out2', lppre3, 'in2', label='23')
        # c23 = Connection(lppre2, 'out2', lppre3_sub, 'in2', label='23')
        # c24 = Connection(lppre3_sub, 'out2', lppre3, 'in2', label='24')
        c25 = Connection(lppre3, 'out2', fwt, 'in1', label='25')
        c26 = Connection(fwt, 'out1', fwp, 'in1', label='26')
        c27 = Connection(fwp, 'out1', hppre1, 'in2', label='27')
        c29 = Connection(hppre1, 'out2', hppre2, 'in2', label='29')
        c31 = Connection(hppre2, 'out2', eco, 'in2', label='31')

        c36 = Connection(sp1, 'out2', hppre2, 'in1', label='36')
        c37 = Connection(hppre2, 'out1', v1, 'in1', label='37')
        c39 = Connection(v1, 'out1', m2, 'in2', label='39')
        c40 = Connection(sp2, 'out2', m2, 'in1', label='40')
        c41 = Connection(m2, 'out1', hppre1, 'in1', label='41')
        c42 = Connection(hppre1, 'out1', v2, 'in1', label='42')
        c44 = Connection(v2, 'out1', fwt, 'in2', label='44')
        c45 = Connection(sp3, 'out2', fwt, 'in3', label='45')
        c46 = Connection(sp4, 'out2', lppre3, 'in1', label='46')
        c47 = Connection(lppre3, 'out1', v3, 'in1', label='47')
        # c47 = Connection(lppre3, 'out1', lppre3_sub, 'in1', label='47')
        # c48 = Connection(lppre3_sub, 'out1', v3, 'in1', label='48')
        c49 = Connection(v3, 'out1', m3, 'in1', label='49')
        c50 = Connection(sp5, 'out2', m3, 'in2', label='50')
        c51 = Connection(m3, 'out1', lppre2, 'in1', label='51')
        c52 = Connection(lppre2, 'out1', v4, 'in1', label='52')
        # c52 = Connection(lppre2, 'out1', lppre2_sub, 'in1', label='52')
        # c53 = Connection(lppre2_sub, 'out1', v4, 'in1', label='53')
        c54 = Connection(v4, 'out1', m4, 'in2', label='54')
        c55 = Connection(sp6, 'out2', m4, 'in1', label='55')
        c56 = Connection(m4, 'out1', lppre1, 'in1', label='56')
        c57 = Connection(lppre1, 'out1', v5, 'in1', label='57')
        # c57 = Connection(lppre1, 'out1', lppre1_sub, 'in1', label='57')
        # c58 = Connection(lppre1_sub, 'out1', v5, 'in1', label='58')
        c59 = Connection(v5, 'out1', m1, 'in2', label='59')

        # components from subsystem
        c32 = Connection(eco, 'out2', drum, 'in1', label='32')
        c33 = Connection(drum, 'out1', eva, 'in2', label='33')
        c34 = Connection(eva, 'out2', drum, 'in2', label='34')
        c35 = Connection(drum, 'out2', sup, 'in2', label='35')
        c73 = Connection(sup, 'out1', eva, 'in1', label='73')
        c74 = Connection(eva, 'out1', eco, 'in1', label='74')

        # cooling water
        c60 = Connection(cond, 'out2', closer_cw, 'in1', label='60')
        c61 = Connection(closer_cw, 'out1', ct, 'in1', label='61')
        c62 = Connection(ct, 'out1', cwp, 'in1', label='62')
        c63 = Connection(cwp, 'out1', cond, 'in2', label='63')

        # cooling tower
        c64 = Connection(air_in, 'out1', fan, 'in1', label='64')
        c65 = Connection(fan, 'out1', ct, 'in2', label='65')
        c66 = Connection(ct, 'out2', air_out, 'in1', label='66')

        # parabolic trough cycle
        c70 = Connection(pt, 'out1', closer_pt, 'in1', label='67')
        c71 = Connection(closer_pt, 'out1', sp7, 'in1', label='71')
        c72 = Connection(sp7, 'out1', sup, 'in1', label='72')
        c75 = Connection(eco, 'out1', m5, 'in1', label='75')
        c76 = Connection(sp7, 'out2', reh, 'in1', label='76')
        c77 = Connection(reh, 'out1', m5, 'in2', label='77')
        c78 = Connection(m5, 'out1', ptpump, 'in1', label='78')
        c79 = Connection(ptpump, 'out1', pt, 'in1', label='79')

        # add connections to network
        self.nw.add_conns(c1, c2, c3, c4, c5, c6, c7, c8, c9, c10, c11, c12,
                          c13, c14, c15, c16, c17, c18, c19, c21, c23, c25,
                          c26, c27, c29, c31, c32, c33, c34, c35, c36, c37,
                          c39, c40, c41, c42, c44, c45, c46, c47, c49, c50,
                          c51, c52, c54, c55, c56, c57, c59, c60, c61, c62,
                          c63, c64, c65, c66, c70, c71, c72, c73, c74, c75,
                          c76, c77, c78, c79)

        # power bus
        power = Bus('total output power')
        power.add_comps({
            'comp': hpt1,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': hpt2,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt1,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt2,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt3,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt4,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': lpt5,
            'char': 0.97,
            'base': 'component'
        }, {
            'comp': fwp,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': condpump,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': ptpump,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': cwp,
            'char': 0.95,
            'base': 'bus'
        }, {
            'comp': fan,
            'char': 0.95,
            'base': 'bus'
        })

        heat_input_bus = Bus('heat input')
        heat_input_bus.add_comps({'comp': pt, 'base': 'bus'})

        exergy_loss_bus = Bus('exergy loss')
        exergy_loss_bus.add_comps({
            'comp': air_in,
            'base': 'bus'
        }, {'comp': air_out})

        self.nw.add_busses(power, heat_input_bus, exergy_loss_bus)

        # component parameters
        pt.set_attr(doc=0.95,
                    aoi=0,
                    Tamb=25,
                    A='var',
                    eta_opt=0.73,
                    c_1=0.00496,
                    c_2=0.000691,
                    E=1000,
                    iam_1=1,
                    iam_2=1)

        ptpump.set_attr(eta_s=0.6)

        eco.set_attr()
        eva.set_attr(ttd_l=5)
        sup.set_attr()

        hpt1.set_attr(eta_s=0.8376)
        hpt2.set_attr(eta_s=0.8463)
        lpt1.set_attr(eta_s=0.8623)
        lpt2.set_attr(eta_s=0.917)
        lpt3.set_attr(eta_s=0.9352)
        lpt4.set_attr(eta_s=0.88)
        lpt5.set_attr(eta_s=0.6445)

        cond.set_attr(pr1=1, pr2=0.9, ttd_u=5)
        condpump.set_attr(eta_s=0.7)
        fwp.set_attr(eta_s=0.7)
        cwp.set_attr(eta_s=0.7)
        ct.set_attr(pr1=0.95)
        fan.set_attr(eta_s=0.6)

        lppre1.set_attr(pr1=1, ttd_u=5)
        lppre2.set_attr(pr1=1, ttd_u=5)
        lppre3.set_attr(pr1=1, ttd_u=5)
        hppre1.set_attr(pr1=1, ttd_u=5)
        hppre2.set_attr(pr1=1, ttd_u=5)

        lppre1_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        lppre2_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        lppre3_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        hppre1_sub.set_attr(pr1=1, pr2=1, ttd_l=10)
        hppre2_sub.set_attr(pr1=1, pr2=1, ttd_l=10)

        # connection parameters
        # parabolic trough cycle
        c70.set_attr(fluid={'TVP1': 1, 'water': 0, 'air': 0}, T=390, p=23.304)
        c76.set_attr(m=Ref(c70, 0.1284, 0))
        c73.set_attr(p=22.753)
        c74.set_attr(p=21.167)
        c78.set_attr(p=20.34)
        c79.set_attr(p=41.024)

        # cooling water
        c62.set_attr(fluid={
            'TVP1': 0,
            'water': 1,
            'air': 0
        },
                     T=30,
                     p=self.pamb)
        # cooling tower
        c64.set_attr(fluid={
            'water': 0,
            'TVP1': 0,
            'air': 1
        },
                     p=self.pamb,
                     T=self.Tamb)
        c65.set_attr(p=self.pamb + 0.0005)
        c66.set_attr(p=self.pamb, T=30)
        # power cycle
        c32.set_attr(Td_bp=-2)
        c34.set_attr(x=0.5)
        c1.set_attr(fluid={'water': 1, 'TVP1': 0, 'air': 0}, p=100, T=371)

        # steam generator pressure values
        c31.set_attr(p=103.56)
        c35.set_attr(p=103.42)

        # turbine pressure values
        c3.set_attr(p=33.61, m=38.969)
        c5.set_attr(p=18.58)
        c7.set_attr(p=17.1, T=371)
        c8.set_attr(p=7.98)
        c10.set_attr(p=2.73)
        c12.set_attr(p=0.96)
        c14.set_attr(p=0.29)

        # preheater pressure values
        c19.set_attr(p=14.755, state='l')
        c21.set_attr(p=9.9975, state='l')
        c23.set_attr(p=8.7012, state='l')
        c25.set_attr(state='l')

        c27.set_attr(p=125)
        c29.set_attr(p=112)

        # condensation
        c16.set_attr(p=0.08)

        # feedwater tank
        c26.set_attr(x=0)

        # a stable solution is generated for parts of the network
        self.nw.solve(mode='design')

        self.nw.del_conns(c19, c21, c23, c27, c29, c37, c42, c47, c52, c57)

        c19 = Connection(condpump, 'out1', lppre1_sub, 'in2', label='19')
        c20 = Connection(lppre1_sub, 'out2', lppre1, 'in2', label='20')
        c21 = Connection(lppre1, 'out2', lppre2_sub, 'in2', label='21')
        c22 = Connection(lppre2_sub, 'out2', lppre2, 'in2', label='22')
        c23 = Connection(lppre2, 'out2', lppre3_sub, 'in2', label='23')
        c24 = Connection(lppre3_sub, 'out2', lppre3, 'in2', label='24')

        c27 = Connection(fwp, 'out1', hppre1_sub, 'in2', label='27')
        c28 = Connection(hppre1_sub, 'out2', hppre1, 'in2', label='28')
        c29 = Connection(hppre1, 'out2', hppre2_sub, 'in2', label='29')
        c30 = Connection(hppre2_sub, 'out2', hppre2, 'in2', label='30')

        c37 = Connection(hppre2, 'out1', hppre2_sub, 'in1', label='37')
        c38 = Connection(hppre2_sub, 'out1', v1, 'in1', label='38')
        c42 = Connection(hppre1, 'out1', hppre1_sub, 'in1', label='42')
        c43 = Connection(hppre1_sub, 'out1', v2, 'in1', label='43')

        c47 = Connection(lppre3, 'out1', lppre3_sub, 'in1', label='47')
        c48 = Connection(lppre3_sub, 'out1', v3, 'in1', label='48')
        c52 = Connection(lppre2, 'out1', lppre2_sub, 'in1', label='52')
        c53 = Connection(lppre2_sub, 'out1', v4, 'in1', label='53')
        c57 = Connection(lppre1, 'out1', lppre1_sub, 'in1', label='57')
        c58 = Connection(lppre1_sub, 'out1', v5, 'in1', label='58')

        self.nw.add_conns(c19, c20, c21, c22, c23, c24, c27, c28, c29, c30,
                          c37, c38, c42, c43, c47, c48, c52, c53, c57, c58)

        # specification of missing parameters
        c19.set_attr(p=14.755)
        c21.set_attr(p=9.9975, state='l')
        c23.set_attr(p=8.7012, state='l')
        c27.set_attr(p=125)
        c29.set_attr(p=112)

        # solve final state
        self.nw.solve(mode='design')
示例#9
0
# mean geothermal temperature (mean value of ground feed and return flow)
Tgeo = 9.5

nw = Network(fluids=['water', 'R410A'],
             T_unit='C',
             p_unit='bar',
             h_unit='kJ / kg',
             m_unit='kg / s')

# %% components

cc = CycleCloser('cycle closer')

# heat pump system
cd = Condenser('condenser')
va = Valve('valve')
ev = HeatExchanger('evaporator')
cp = Compressor('compressor')

# geothermal heat collector
gh_in = Source('ground heat feed flow')
gh_out = Sink('ground heat return flow')
ghp = Pump('ground heat loop pump')

# heating system
hs_feed = Sink('heating system feed flow')
hs_ret = Source('heating system return flow')
hsp = Pump('heating system pump')

# %% connections
示例#10
0
# sources & sinks

close_cycle = CycleCloser('cycle closer')

sys_rf = Source('system return')
sys_ff = Sink('system feed')

sto_rf = Source('storage return')
sto_ff = Sink('storage feed')

# consumer system
cd = Condenser('condenser')

# evaporator system

valve = Valve('valve')
dr = Drum('drum')
ev = HeatExchanger('evaporator')
su = HeatExchanger('superheater')
pump_ev = Pump('evaporator reciculation pump')

# compressor-system

cp = Compressor('compressor 1')

# %% connections

# heating system interface

sys_IF = Connection(sys_rf, 'out1', cd, 'in2')
IF_sys = Connection(cd, 'out2', sys_ff, 'in1')
示例#11
0
    def setup(self):
        # %% network setup
        self.nw = Network(fluids=['water', 'NH3'],
                          T_unit='C',
                          p_unit='bar',
                          h_unit='kJ / kg',
                          m_unit='kg / s')

        # %% components
        # sources & sinks
        cc_coolant = CycleCloser('coolant cycle closer')
        cc_consumer = CycleCloser('consumer cycle closer')
        amb_in = Source('source ambient')
        amb_out = Sink('sink ambient')
        ic_in = Source('source intercool')
        ic_out = Sink('sink intercool')

        # consumer system
        cd = HeatExchanger('condenser')
        rp = Pump('recirculation pump')
        cons = HeatExchangerSimple('consumer')

        # evaporator system
        va = Valve('valve')
        dr = Drum('drum')
        ev = HeatExchanger('evaporator')
        su = HeatExchanger('superheater')
        pu = Pump('pump evaporator')

        # compressor-system
        cp1 = Compressor('compressor 1')
        cp2 = Compressor('compressor 2')
        he = HeatExchanger('intercooler')

        # busses
        self.power = Bus('total compressor power')
        self.power.add_comps({
            'comp': cp1,
            'base': 'bus'
        }, {
            'comp': cp2,
            'base': 'bus'
        })
        self.heat = Bus('total delivered heat')
        self.heat.add_comps({'comp': cd, 'char': -1})
        self.nw.add_busses(self.power, self.heat)

        # %% connections
        # consumer system
        c_in_cd = Connection(cc_coolant, 'out1', cd, 'in1')

        cb_rp = Connection(cc_consumer, 'out1', rp, 'in1')
        rp_cd = Connection(rp, 'out1', cd, 'in2')
        self.cd_cons = Connection(cd, 'out2', cons, 'in1')
        cons_cf = Connection(cons, 'out1', cc_consumer, 'in1')

        self.nw.add_conns(c_in_cd, cb_rp, rp_cd, self.cd_cons, cons_cf)

        # connection condenser - evaporator system
        cd_va = Connection(cd, 'out1', va, 'in1')

        self.nw.add_conns(cd_va)

        # evaporator system
        va_dr = Connection(va, 'out1', dr, 'in1')
        dr_pu = Connection(dr, 'out1', pu, 'in1')
        pu_ev = Connection(pu, 'out1', ev, 'in2')
        ev_dr = Connection(ev, 'out2', dr, 'in2')
        dr_su = Connection(dr, 'out2', su, 'in2')

        self.nw.add_conns(va_dr, dr_pu, pu_ev, ev_dr, dr_su)

        self.amb_in_su = Connection(amb_in, 'out1', su, 'in1')
        su_ev = Connection(su, 'out1', ev, 'in1')
        ev_amb_out = Connection(ev, 'out1', amb_out, 'in1')

        self.nw.add_conns(self.amb_in_su, su_ev, ev_amb_out)

        # connection evaporator system - compressor system
        su_cp1 = Connection(su, 'out2', cp1, 'in1')

        self.nw.add_conns(su_cp1)

        # compressor-system
        cp1_he = Connection(cp1, 'out1', he, 'in1')
        he_cp2 = Connection(he, 'out1', cp2, 'in1')
        cp2_c_out = Connection(cp2, 'out1', cc_coolant, 'in1')

        ic_in_he = Connection(ic_in, 'out1', he, 'in2')
        he_ic_out = Connection(he, 'out2', ic_out, 'in1')

        self.nw.add_conns(cp1_he, he_cp2, ic_in_he, he_ic_out, cp2_c_out)

        # %% component parametrization
        # condenser system
        x = np.array([
            0, 0.0625, 0.125, 0.1875, 0.25, 0.3125, 0.375, 0.4375, 0.5, 0.5625,
            0.6375, 0.7125, 0.7875, 0.9, 0.9875, 1, 1.0625, 1.125, 1.175,
            1.2125, 1.2375, 1.25
        ])
        y = np.array([
            0.0076, 0.1390, 0.2731, 0.4003, 0.5185, 0.6263, 0.7224, 0.8056,
            0.8754, 0.9312, 0.9729, 1.0006, 1.0203, 1.0158, 1.0051, 1.0000,
            0.9746, 0.9289, 0.8832, 0.8376, 0.7843, 0.7614
        ])
        rp.set_attr(eta_s=0.8,
                    design=['eta_s'],
                    offdesign=['eta_s_char'],
                    eta_s_char={
                        'char_func': CharLine(x, y),
                        'param': 'm'
                    })
        cons.set_attr(pr=1, design=['pr'], offdesign=['zeta'])

        # evaporator system
        x = np.linspace(0, 2.5, 26)
        y = np.array([
            0.000, 0.164, 0.283, 0.389, 0.488, 0.581, 0.670, 0.756, 0.840,
            0.921, 1.000, 1.078, 1.154, 1.228, 1.302, 1.374, 1.446, 1.516,
            1.585, 1.654, 1.722, 1.789, 1.855, 1.921, 1.986, 2.051
        ])
        kA_char1 = {'char_func': CharLine(x, y), 'param': 'm'}

        x = np.array([
            0.0100, 0.0400, 0.0700, 0.1100, 0.1500, 0.2000, 0.2500, 0.3000,
            0.3500, 0.4000, 0.4500, 0.5000, 0.5500, 0.6000, 0.6500, 0.7000,
            0.7500, 0.8000, 0.8500, 0.9000, 0.9500, 1.0000, 1.5000, 2.0000
        ])

        y = np.array([
            0.0185, 0.0751, 0.1336, 0.2147, 0.2997, 0.4118, 0.5310, 0.6582,
            0.7942, 0.9400, 0.9883, 0.9913, 0.9936, 0.9953, 0.9966, 0.9975,
            0.9983, 0.9988, 0.9992, 0.9996, 0.9998, 1.0000, 1.0008, 1.0014
        ])
        kA_char2 = {'char_func': CharLine(x, y), 'param': 'm'}
        ev.set_attr(pr1=1,
                    pr2=.999,
                    ttd_l=5,
                    design=['ttd_l'],
                    offdesign=['kA_char'],
                    kA_char1=kA_char1,
                    kA_char2=kA_char2)

        # no kA modification for hot side!
        x = np.array([0, 1])
        y = np.array([1, 1])
        kA_char1 = {'char_func': CharLine(x, y), 'param': 'm'}

        # characteristic line for superheater kA
        x = np.array(
            [0, 0.045, 0.136, 0.244, 0.43, 0.6, 0.7, 0.8, 0.9, 1, 1.1, 1.2])
        y = np.array(
            [0, 0.037, 0.112, 0.207, 0.5, 0.8, 0.85, 0.9, 0.95, 1, 1.04, 1.07])
        kA_char2 = {'char_func': CharLine(x, y), 'param': 'm'}
        su.set_attr(kA_char1=kA_char1,
                    kA_char2=kA_char2,
                    offdesign=['zeta1', 'zeta2', 'kA_char'])

        x = np.array([
            0, 0.0625, 0.125, 0.1875, 0.25, 0.3125, 0.375, 0.4375, 0.5, 0.5625,
            0.6375, 0.7125, 0.7875, 0.9, 0.9875, 1, 1.0625, 1.125, 1.175,
            1.2125, 1.2375, 1.25
        ])
        y = np.array([
            0.0076, 0.1390, 0.2731, 0.4003, 0.5185, 0.6263, 0.7224, 0.8056,
            0.8754, 0.9312, 0.9729, 1.0006, 1.0203, 1.0158, 1.0051, 1.0000,
            0.9746, 0.9289, 0.8832, 0.8376, 0.7843, 0.7614
        ])
        pu.set_attr(eta_s=0.8,
                    design=['eta_s'],
                    offdesign=['eta_s_char'],
                    eta_s_char={
                        'char_func': CharLine(x, y),
                        'param': 'm'
                    })

        # compressor system
        x = np.array([0, 0.4, 1, 1.2])
        y = np.array([0.5, 0.9, 1, 1.1])

        cp1.set_attr(eta_s=0.8,
                     design=['eta_s'],
                     offdesign=['eta_s_char'],
                     eta_s_char={
                         'char_func': CharLine(x, y),
                         'param': 'm'
                     })
        cp2.set_attr(eta_s=0.8,
                     design=['eta_s'],
                     offdesign=['eta_s_char'],
                     eta_s_char={
                         'char_func': CharLine(x, y),
                         'param': 'm'
                     })

        # characteristic line for intercooler kA
        x = np.linspace(0, 2.5, 26)
        y = np.array([
            0.0000, 0.2455, 0.3747, 0.4798, 0.5718, 0.6552, 0.7323, 0.8045,
            0.8727, 0.9378, 1.0000, 1.0599, 1.1176, 1.1736, 1.2278, 1.2806,
            1.3320, 1.3822, 1.4313, 1.4792, 1.5263, 1.5724, 1.6176, 1.6621,
            1.7058, 1.7488
        ])
        kA_char1 = {'char_func': CharLine(x, y), 'param': 'm'}

        x = np.linspace(0, 2.5, 26)
        y = np.array([
            0.000, 0.164, 0.283, 0.389, 0.488, 0.581, 0.670, 0.756, 0.840,
            0.921, 1.000, 1.078, 1.154, 1.228, 1.302, 1.374, 1.446, 1.516,
            1.585, 1.654, 1.722, 1.789, 1.855, 1.921, 1.986, 2.051
        ])
        kA_char2 = {'char_func': CharLine(x, y), 'param': 'm'}

        he.set_attr(kA_char1=kA_char1,
                    kA_char2=kA_char2,
                    offdesign=['zeta1', 'zeta2', 'kA_char'])

        # characteristic line for condenser kA
        x = np.linspace(0, 2.5, 26)
        y = np.array([
            0.0000, 0.2455, 0.3747, 0.4798, 0.5718, 0.6552, 0.7323, 0.8045,
            0.8727, 0.9378, 1.0000, 1.0599, 1.1176, 1.1736, 1.2278, 1.2806,
            1.3320, 1.3822, 1.4313, 1.4792, 1.5263, 1.5724, 1.6176, 1.6621,
            1.7058, 1.7488
        ])
        kA_char1 = {'char_func': CharLine(x, y), 'param': 'm'}

        x = np.linspace(0, 2.5, 26)
        y = np.array([
            0.000, 0.164, 0.283, 0.389, 0.488, 0.581, 0.670, 0.756, 0.840,
            0.921, 1.000, 1.078, 1.154, 1.228, 1.302, 1.374, 1.446, 1.516,
            1.585, 1.654, 1.722, 1.789, 1.855, 1.921, 1.986, 2.051
        ])
        kA_char2 = {'char_func': CharLine(x, y), 'param': 'm'}

        cd.set_attr(kA_char1=kA_char1,
                    kA_char2=kA_char2,
                    pr2=0.9998,
                    design=['pr2'],
                    offdesign=['zeta2', 'kA_char'])

        # %% connection parametrization
        # condenser system
        c_in_cd.set_attr(fluid={'water': 0, 'NH3': 1}, p=60)
        rp_cd.set_attr(T=60, fluid={'water': 1, 'NH3': 0}, p=10)
        self.cd_cons.set_attr(T=105)
        cd_va.set_attr(p=Ref(c_in_cd, 1, -0.01), Td_bp=-5, design=['Td_bp'])

        # evaporator system cold side
        pu_ev.set_attr(m=Ref(va_dr, 10, 0), p0=5)
        dr_su.set_attr(p0=5, T=5)
        su_cp1.set_attr(p=Ref(dr_su, 1, -0.05), Td_bp=5, design=['Td_bp', 'p'])

        # evaporator system hot side
        self.amb_in_su.set_attr(m=20, T=12, p=1, fluid={'water': 1, 'NH3': 0})
        su_ev.set_attr(p=Ref(self.amb_in_su, 1, -0.001), design=['p'])
        ev_amb_out.set_attr()

        # compressor-system
        cp1_he.set_attr(p=15)
        he_cp2.set_attr(T=40, p=Ref(cp1_he, 1, -0.01), design=['T', 'p'])
        ic_in_he.set_attr(p=1, T=20, m=5, fluid={'water': 1, 'NH3': 0})
        he_ic_out.set_attr(p=Ref(ic_in_he, 1, -0.002), design=['p'])
示例#12
0
# mean geothermal temperature (mean value of ground feed and return flow)
Tgeo = 9.5

nw = Network(fluids=['water', 'R410A'],
             T_unit='C',
             p_unit='bar',
             h_unit='kJ / kg',
             m_unit='kg / s')

# %% components

cc = CycleCloser('cycle closer')

# heat pump system
cd = Condenser('condenser')
va = Valve('valve')
ev = HeatExchanger('evaporator')
cp = Compressor('compressor')

# geothermal heat collector
gh_in = Source('ground heat feed flow')
gh_out = Sink('ground heat return flow')
ghp = Pump('ground heat loop pump')

# heating system
hs_feed = Sink('heating system feed flow')
hs_ret = Source('heating system return flow')
hsp = Pump('heating system pump')

# %% connections
示例#13
0
drum = Drum('drum')
eco = HeatExchanger('economizer')
ch = Sink('chimney')

# steam turbine part
turb_hp = Turbine('steam turbine high pressure')
cond_dh = Condenser('district heating condenser')
mp_split = Splitter('mp split')
turb_lp = Turbine('steam turbine low pressure')
cond = Condenser('condenser')
merge = Merge('merge')
pump1 = Pump('feed water pump 1')
pump2 = Pump('feed water pump 2')
ls_out = Sink('ls sink')
ls_in = Source('ls source')
mp_valve = Valve('mp valve')

# district heating
dh_in = Source('district heating backflow')
dh_out = Sink('district heating feedflow')

# cooling water
cw_in = Source('cooling water backflow')
cw_out = Sink('cooling water feedflow')

# %% connections
# gas turbine part
c_in = Connection(air, 'out1', comp, 'in1')
c_out = Connection(comp, 'out1', c_c, 'in1')
fuel_comp = Connection(CH4, 'out1', comp_fuel, 'in1')
comp_cc = Connection(comp_fuel, 'out1', c_c, 'in2')
示例#14
0
from tespy.tools import document_model

import matplotlib.pyplot as plt
import pandas as pd
import numpy as np

# %% network

fluids = ['water']

nw = Network(fluids=fluids, p_unit='bar', T_unit='C', h_unit='kJ / kg', iterinfo=False)

# %% components

# turbine part
valve_turb = Valve('turbine inlet valve')
turbine_hp = Turbine('high pressure turbine')
split = Splitter('extraction splitter')
turbine_lp = Turbine('low pressure turbine')

# condenser and preheater
cond = Condenser('condenser')
preheater = Condenser('preheater')
merge_ws = Merge('waste steam merge')
valve_pre = Valve('preheater valve')

# feed water
pump = Pump('pump')
steam_generator = HeatExchangerSimple('steam generator')

closer = CycleCloser('cycle closer')