示例#1
0
def validate_component_cli(component_types: Tuple[Type[BaseComponentAPI], ...],
                           boot_info: BootInfo) -> None:
    # Let the components do runtime validation
    for component_cls in component_types:
        try:
            component_cls.validate_cli(boot_info)
        except ValidationError as exc:
            parser.exit(message=str(exc))
示例#2
0
def main_entry(trinity_boot: BootFn, app_identifier: str,
               component_types: Tuple[Type[BaseComponentAPI], ...],
               sub_configs: Sequence[Type[BaseAppConfig]]) -> None:
    if is_prerelease():
        # this modifies the asyncio logger, but will be overridden by any custom settings below
        enable_warnings_by_default()

    for component_cls in component_types:
        component_cls.configure_parser(parser, subparser)

    argcomplete.autocomplete(parser)

    args = parser.parse_args()

    if not args.genesis and args.network_id not in PRECONFIGURED_NETWORKS:
        parser.error(
            f"Unsupported network id: {args.network_id}. To use a network besides "
            "mainnet, ropsten or goerli, you must supply a genesis file with a flag, like "
            "`--genesis path/to/genesis.json`, also you must specify a data "
            "directory with `--data-dir path/to/data/directory`")

    # The `common_log_level` is derived from `--log-level <Level>` / `-l <Level>` without
    # specifying any module. If present, it is used for both `stderr` and `file` logging.
    common_log_level = args.log_levels and args.log_levels.get(None)
    has_ambigous_logging_config = (
        (common_log_level is not None and args.stderr_log_level is not None)
        or (common_log_level is not None and args.file_log_level is not None))

    if has_ambigous_logging_config:
        parser.error(f"""\n
            Ambiguous logging configuration: The `--log-level (-l)` flag sets the
            log level for both file and stderr logging.
            To configure different log level for file and stderr logging,
            remove the `--log-level` flag and use `--stderr-log-level` and/or
            `--file-log-level` separately.
            Alternatively, remove the `--stderr-log-level` and/or `--file-log-level`
            flags to share one single log level across both handlers.
            """)

    trinity_config = load_trinity_config_from_parser_args(
        parser, args, app_identifier, sub_configs)

    ensure_data_dir_is_initialized(trinity_config)

    # +---------------+
    # | LOGGING SETUP |
    # +---------------+

    # Setup logging to stderr
    stderr_logger_level = (
        args.stderr_log_level if args.stderr_log_level is not None else
        (common_log_level if common_log_level is not None else logging.INFO))
    handler_stderr = setup_stderr_logging(stderr_logger_level)

    # Setup file based logging
    file_logger_level = (
        args.file_log_level if args.file_log_level is not None else
        (common_log_level if common_log_level is not None else logging.DEBUG))
    handler_file = setup_file_logging(trinity_config.logfile_path,
                                      file_logger_level)

    # Set the individual logger levels that have been specified.
    logger_levels = {} if args.log_levels is None else args.log_levels
    set_logger_levels(logger_levels)

    # get the root logger and set it to the level of the stderr logger.
    logger = logging.getLogger()
    logger.setLevel(stderr_logger_level)

    # This prints out the ASCII "trinity" header in the terminal
    display_launch_logs(trinity_config)

    # Setup the log listener which child processes relay their logs through
    log_listener = IPCListener(handler_stderr, handler_file)

    # Determine what logging level child processes should use.
    child_process_log_level = min(
        stderr_logger_level,
        file_logger_level,
        *logger_levels.values(),
    )

    boot_info = BootInfo(
        args=args,
        trinity_config=trinity_config,
        child_process_log_level=child_process_log_level,
        logger_levels=logger_levels,
        profile=bool(args.profile),
    )

    # Let the components do runtime validation
    for component_cls in component_types:
        try:
            component_cls.validate_cli(boot_info)
        except ValidationError as exc:
            parser.exit(message=str(exc))

    # Components can provide a subcommand with a `func` which does then control
    # the entire process from here.
    if hasattr(args, 'func'):
        args.func(args, trinity_config)
        return

    runtime_component_types = tuple(component_cls
                                    for component_cls in component_types
                                    if issubclass(component_cls, ComponentAPI))

    with log_listener.run(trinity_config.logging_ipc_path):

        processes = trinity_boot(boot_info)

        loop = asyncio.get_event_loop()

        def kill_trinity_with_reason(reason: str) -> None:
            kill_trinity_gracefully(trinity_config,
                                    logger,
                                    processes,
                                    reason=reason)

        component_manager_service = ComponentManager(
            boot_info,
            runtime_component_types,
        )
        manager = AsyncioManager(component_manager_service)

        loop.add_signal_handler(
            signal.SIGTERM,
            manager.cancel,
            'SIGTERM',
        )
        loop.add_signal_handler(
            signal.SIGINT,
            component_manager_service.shutdown,
            'CTRL+C',
        )

        try:
            loop.run_until_complete(manager.run())
        except BaseException as err:
            logger.error("Error during trinity run: %r", err)
            raise
        finally:
            kill_trinity_with_reason(component_manager_service.reason)
            if trinity_config.trinity_tmp_root_dir:
                shutil.rmtree(trinity_config.trinity_root_dir)