def run_async_server():
    # ----------------------------------------------------------------------- #
    # initialize your data store
    # ----------------------------------------------------------------------- #
    store = ModbusSlaveContext(di=ModbusSequentialDataBlock(0, [17] * 100),
                               co=ModbusSequentialDataBlock(0, [17] * 100),
                               hr=ModbusSequentialDataBlock(0, [17] * 100),
                               ir=ModbusSequentialDataBlock(0, [17] * 100))
    store.register(CustomModbusRequest.function_code, 'cm',
                   ModbusSequentialDataBlock(0, [17] * 100))
    context = ModbusServerContext(slaves=store, single=True)

    # ----------------------------------------------------------------------- #
    # initialize the server information
    identity = ModbusDeviceIdentification()
    identity.VendorName = 'Pymodbus'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'http://github.com/bashwork/pymodbus/'
    identity.ProductName = 'Pymodbus Server'
    identity.ModelName = 'Pymodbus Server'
    identity.MajorMinorRevision = '2.2.0'

    # ----------------------------------------------------------------------- #
    # run the server you want
    # ----------------------------------------------------------------------- #
    StartTcpServer(context,
                   identity=identity,
                   address=("192.168.0.119", 5020),
                   custom_functions=[CustomModbusRequest])
Ejemplo n.º 2
0
def run_server():
    store = ModbusSlaveContext(di=ModbusSequentialDataBlock(0, [17] * 100),
                               co=ModbusSequentialDataBlock(0, [17] * 100),
                               hr=ModbusSequentialDataBlock(0, [17] * 100),
                               ir=ModbusSequentialDataBlock(0, [17] * 100))

    store.register(CustomModbusRequest.function_code, 'cm',
                   ModbusSequentialDataBlock(0, [17] * 100))
    context = ModbusServerContext(slaves=store, single=True)

    # ----------------------------------------------------------------------- #
    # initialize the server information
    # ----------------------------------------------------------------------- #
    # If you don't set this or any fields, they are defaulted to empty strings.
    # ----------------------------------------------------------------------- #
    identity = ModbusDeviceIdentification()
    identity.VendorName = 'Pymodbus'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'http://github.com/riptideio/pymodbus/'
    identity.ProductName = 'Pymodbus Server'
    identity.ModelName = 'Pymodbus Server'
    identity.MajorMinorRevision = '2.1.0'

    # ----------------------------------------------------------------------- #
    # run the server you want
    # ----------------------------------------------------------------------- #
    # Tcp:
    StartTcpServer(context,
                   identity=identity,
                   address=("localhost", 5020),
                   custom_functions=[CustomModbusRequest])
Ejemplo n.º 3
0
def sniff_modbus_rtu():
    store = ModbusSlaveContext(
        hr=ModbusSequentialDataBlock(0, [17]*100)
    )

    store.register(fc=301, fx='cm', datablock=ModbusSequentialDataBlock(0, [17] * 100))
    context = ModbusServerContext(slaves=store, single=True)

    identity = ModbusDeviceIdentification()
    identity.VendorName = 'ETRI'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'None'
    identity.ProductName = 'Sniffer'
    identity.ModelName = 'LabSlave'
    identity.MajorMinorRevision = '0.0.1'

    StartSerialServer(context, identity=identity, port="/dev/tty.usbserial-AK066TL5", framer=ModbusRtuFramer)
def run_async_server():
    # ----------------------------------------------------------------------- #
    # initialize your data store
    # ----------------------------------------------------------------------- #
    # The datastores only respond to the addresses that they are initialized to
    # Therefore, if you initialize a DataBlock to addresses from 0x00 to 0xFF,
    # a request to 0x100 will respond with an invalid address exception.
    # This is because many devices exhibit this kind of behavior (but not all)
    #
    #     block = ModbusSequentialDataBlock(0x00, [0]*0xff)
    #
    # Continuing, you can choose to use a sequential or a sparse DataBlock in
    # your data context.  The difference is that the sequential has no gaps in
    # the data while the sparse can. Once again, there are devices that exhibit
    # both forms of behavior::
    #
    #     block = ModbusSparseDataBlock({0x00: 0, 0x05: 1})
    #     block = ModbusSequentialDataBlock(0x00, [0]*5)
    #
    # Alternately, you can use the factory methods to initialize the DataBlocks
    # or simply do not pass them to have them initialized to 0x00 on the full
    # address range::
    #
    #     store = ModbusSlaveContext(di = ModbusSequentialDataBlock.create())
    #     store = ModbusSlaveContext()
    #
    # Finally, you are allowed to use the same DataBlock reference for every
    # table or you you may use a seperate DataBlock for each table.
    # This depends if you would like functions to be able to access and modify
    # the same data or not::
    #
    #     block = ModbusSequentialDataBlock(0x00, [0]*0xff)
    #     store = ModbusSlaveContext(di=block, co=block, hr=block, ir=block)
    #
    # The server then makes use of a server context that allows the server to
    # respond with different slave contexts for different unit ids. By default
    # it will return the same context for every unit id supplied (broadcast
    # mode).
    # However, this can be overloaded by setting the single flag to False
    # and then supplying a dictionary of unit id to context mapping::
    #
    #     slaves  = {
    #         0x01: ModbusSlaveContext(...),
    #         0x02: ModbusSlaveContext(...),
    #         0x03: ModbusSlaveContext(...),
    #     }
    #     context = ModbusServerContext(slaves=slaves, single=False)
    #
    # The slave context can also be initialized in zero_mode which means that a
    # request to address(0-7) will map to the address (0-7). The default is
    # False which is based on section 4.4 of the specification, so address(0-7)
    # will map to (1-8)::
    #
    #     store = ModbusSlaveContext(..., zero_mode=True)
    # ----------------------------------------------------------------------- #
    store = ModbusSlaveContext(di=ModbusSequentialDataBlock(0, [17] * 100),
                               co=ModbusSequentialDataBlock(0, [17] * 100),
                               hr=ModbusSequentialDataBlock(0, [17] * 100),
                               ir=ModbusSequentialDataBlock(0, [17] * 100))
    store.register(CustomModbusRequest.function_code, 'cm',
                   ModbusSequentialDataBlock(0, [17] * 100))
    context = ModbusServerContext(slaves=store, single=True)

    # ----------------------------------------------------------------------- #
    # initialize the server information
    # ----------------------------------------------------------------------- #
    # If you don't set this or any fields, they are defaulted to empty strings.
    # ----------------------------------------------------------------------- #
    identity = ModbusDeviceIdentification()
    identity.VendorName = 'Pymodbus'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'http://github.com/bashwork/pymodbus/'
    identity.ProductName = 'Pymodbus Server'
    identity.ModelName = 'Pymodbus Server'
    identity.MajorMinorRevision = '2.2.0'

    # ----------------------------------------------------------------------- #
    # run the server you want
    # ----------------------------------------------------------------------- #

    # TCP Server

    # StartTcpServer(context, identity=identity, address=("localhost", 5020),
    #                custom_functions=[CustomModbusRequest])

    # TCP Server with deferred reactor run

    # from twisted.internet import reactor
    # StartTcpServer(context, identity=identity, address=("localhost", 5020),
    #                defer_reactor_run=True)
    # reactor.run()

    # Server with RTU framer
    # StartTcpServer(context, identity=identity, address=("localhost", 5020),
    #                framer=ModbusRtuFramer)

    # UDP Server
    # StartUdpServer(context, identity=identity, address=("127.0.0.1", 5020))

    # RTU Server
    StartSerialServer(context,
                      identity=identity,
                      port='/dev/ttyp0',
                      framer=ModbusRtuFramer)
Ejemplo n.º 5
0
def run_async_server():
    # ----------------------------------------------------------------------- # 
    # initialize your data store
    # ----------------------------------------------------------------------- # 
    # The datastores only respond to the addresses that they are initialized to
    # Therefore, if you initialize a DataBlock to addresses from 0x00 to 0xFF,
    # a request to 0x100 will respond with an invalid address exception.
    # This is because many devices exhibit this kind of behavior (but not all)
    #
    #     block = ModbusSequentialDataBlock(0x00, [0]*0xff)
    #
    # Continuing, you can choose to use a sequential or a sparse DataBlock in
    # your data context.  The difference is that the sequential has no gaps in
    # the data while the sparse can. Once again, there are devices that exhibit
    # both forms of behavior::
    #
    #     block = ModbusSparseDataBlock({0x00: 0, 0x05: 1})
    #     block = ModbusSequentialDataBlock(0x00, [0]*5)
    #
    # Alternately, you can use the factory methods to initialize the DataBlocks
    # or simply do not pass them to have them initialized to 0x00 on the full
    # address range::
    #
    #     store = ModbusSlaveContext(di = ModbusSequentialDataBlock.create())
    #     store = ModbusSlaveContext()
    #
    # Finally, you are allowed to use the same DataBlock reference for every
    # table or you you may use a seperate DataBlock for each table.
    # This depends if you would like functions to be able to access and modify
    # the same data or not::
    #
    #     block = ModbusSequentialDataBlock(0x00, [0]*0xff)
    #     store = ModbusSlaveContext(di=block, co=block, hr=block, ir=block)
    #
    # The server then makes use of a server context that allows the server to
    # respond with different slave contexts for different unit ids. By default
    # it will return the same context for every unit id supplied (broadcast
    # mode).
    # However, this can be overloaded by setting the single flag to False
    # and then supplying a dictionary of unit id to context mapping::
    #
    #     slaves  = {
    #         0x01: ModbusSlaveContext(...),
    #         0x02: ModbusSlaveContext(...),
    #         0x03: ModbusSlaveContext(...),
    #     }
    #     context = ModbusServerContext(slaves=slaves, single=False)
    #
    # The slave context can also be initialized in zero_mode which means that a
    # request to address(0-7) will map to the address (0-7). The default is
    # False which is based on section 4.4 of the specification, so address(0-7)
    # will map to (1-8)::
    #
    #     store = ModbusSlaveContext(..., zero_mode=True)
    # ----------------------------------------------------------------------- # 
    store = ModbusSlaveContext(
        di=ModbusSequentialDataBlock(0, [17]*100),
        co=ModbusSequentialDataBlock(0, [17]*100),
        hr=ModbusSequentialDataBlock(0, [17]*100),
        ir=ModbusSequentialDataBlock(0, [17]*100))
    store.register(CustomModbusRequest.function_code, 'cm',
                   ModbusSequentialDataBlock(0, [17] * 100))
    context = ModbusServerContext(slaves=store, single=True)
    
    # ----------------------------------------------------------------------- # 
    # initialize the server information
    # ----------------------------------------------------------------------- # 
    # If you don't set this or any fields, they are defaulted to empty strings.
    # ----------------------------------------------------------------------- # 
    identity = ModbusDeviceIdentification()
    identity.VendorName = 'Pymodbus'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'http://github.com/bashwork/pymodbus/'
    identity.ProductName = 'Pymodbus Server'
    identity.ModelName = 'Pymodbus Server'
    identity.MajorMinorRevision = '2.2.0'
    
    # ----------------------------------------------------------------------- # 
    # run the server you want
    # ----------------------------------------------------------------------- # 

    # TCP Server

    StartTcpServer(context, identity=identity, address=("localhost", 5020),
                   custom_functions=[CustomModbusRequest])