# * DISPENSE WATER ------------------------------------------

# Program Variables
transfer_volume = 180
blowoff_volume = 0

soloSoft.getTip()
for i in range(1, 3):  # columns in 12 channel reservoir
    for j in range(1, 7):  # <- columns in corning 3635 clearUV
        soloSoft.aspirate(
            position="Position3",
            aspirate_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup().setColumn(
                i, transfer_volume
            ),
            aspirate_shift=[
                0,
                0,
                4,
            ],  # larger shift needed for 12 channel resevoir <- check this with new plate entries
            pre_aspirate=blowoff_volume,
        )
        soloSoft.dispense(
            position="Position6",
            dispense_volumes=Plate_96_Corning_3635_ClearUVAssay().setColumn(
                (((i - 1) * 6) + j), transfer_volume
            ),
            dispense_shift=[0, 0, 2],
            blowoff=blowoff_volume,
        )

# DISPENSE BUFFER ------------------------------------------
soloSoft = SoloSoft(
    filename="cherry_picking_test.hso",
    plateList=[
        "TipBox.50uL.Axygen-EV-50-R-S.tealbox",
        "Empty",
        "Empty",
        "Empty",
        "Empty",
        "Empty",
        "Empty",
        "Plate.96.Corning-3635.ClearUVAssay",
    ],
)

soloSoft.getTip()
soloSoft.aspirate(
    position="Position8",
    aspirate_volumes=Plate_96_Corning_3635_ClearUVAssay().setColumn(1, 50),
    aspirate_shift=[0, 0, 2],
)

for i in range(3):
    soloSoft.dispense(
        position="Position8",
        dispense_volumes=Plate_96_Corning_3635_ClearUVAssay().setColumn(2, 10),
        dispense_shift=[0, 0, 2],
    )

soloSoft.shuckTip()
soloSoft.savePipeline()
Esempio n. 3
0
        "TipBox.50uL.Axygen-EV-50-R-S.tealbox",
        "Empty",
    ],
)

# * STEP 1: Transfer Cells ------------------------------------------------------------
soloSoft.getTip(
)  # 200uL tips -> all transfers are same cells, OK to keep same tips for all of step 1
for i in range(1, 3):
    for j in range(1, 7):
        soloSoft.aspirate(
            position="Position3",
            aspirate_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup(
            ).setColumn(i, cell_transfer_volume),
            aspirate_shift=[0, 0, cell_aspirate_z_shift],
            pre_aspirate=cell_blowoff,
            mix_at_start=
            True,  # mix cells before aspirating them -> probably a good idea
            mix_volume=cell_mix_volume,
            mix_cycles=cell_num_mixes,
            dispense_height=cell_aspirate_z_shift,
        )
        soloSoft.dispense(
            position="Position4",
            dispense_volumes=Plate_96_Corning_3635_ClearUVAssay().setColumn(
                (6 * (i - 1)) + j, cell_transfer_volume),
            dispense_shift=[0, 0, default_z_shift],
            blowoff=cell_blowoff,
            # no need to mix because it will shake in the Hidex
        )

        # for testing
Esempio n. 4
0
        "Plate.96.PlateOne-1833-9600.ConicalBottomStorage",
        "Plate.96.PlateOne-1833-9600.ConicalBottomStorage",
        "TipBox.50uL.Axygen-EV-50-R-S.tealbox",
        "Empty",
    ],
)

soloSoft.getTip()

for i in range(12):
    soloSoft.aspirate(
        position="Position3",
        aspirate_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup().
        setColumn(aspirate_column, aspirate_volume),
        aspirate_shift=[0, 0, default_z_shift],
        pre_aspirate=default_blowoff,
        # mix_at_start=True,
        # mix_cycles=aspirate_num_mixes,
        # mix_volume=aspirate_mix_volume,
        # dispense_height=default_z_shift,
        syringe_speed=aspirate_syringe_speed,
    )
    soloSoft.dispense(
        position="Position3",
        dispense_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup().
        setColumn(dispense_column, aspirate_volume),
        dispense_shift=[0, 0, default_z_shift],
        blowoff=default_blowoff,
        syringe_speed=aspirate_syringe_speed,
    )

soloSoft.shuckTip()
        "Reservoir.12col.Agilent-201256-100.BATSgroup",
        "Empty",
        "Plate.96.Corning-3635.ClearUVAssay",
        "Plate.96.Corning-3635.ClearUVAssay",
        "TipBox.50uL.Axygen-EV-50-R-S.tealbox",
        "AgarPlate.40mL.OmniTray-242811.ColonyPicker",
    ],
)

# * STEP 1: Dispense diluent into whole plate -> MUST CHECK/REFILL BETWEEN CREATING EACH PLATE -------------
soloSoft.getTip()
# Don't dispense diluent into first column of each half plate -> will be pure stock
for i in range(2, 7):  # first half of the plate, columns 2-6
    soloSoft.aspirate(
        position="Position3",
        aspirate_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup().
        setColumn(media_aspirate_column, dilution_media_volume),
        aspirate_shift=[0, 0, 4],
    )
    soloSoft.dispense(
        position="Position6",
        dispense_volumes=Plate_96_Corning_3635_ClearUVAssay().setColumn(
            i, dilution_media_volume),
        dispense_shift=[0, 0, default_z_shift],
    )
media_aspirate_column += 1
for i in range(8, 13):  # second half of the plate, columns 8-12
    soloSoft.aspirate(
        position="Position3",
        aspirate_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup().
        setColumn(media_aspirate_column, dilution_media_volume),
        aspirate_shift=[0, 0, 4],
Esempio n. 6
0
        "Plate.96.Corning-3635.ClearUVAssay",
        "Plate.96.Corning-3635.ClearUVAssay",
        "Empty",
    ],
)

# * Fill 6 columns of empty 96 well plate (corning 3383 or Falcon - ref 353916) with fresh lb media (12 channel in Position 3, column 1)
soloSoft.getTip()
j = 1
for i in range(1, 7):
    soloSoft.aspirate(
        position="Position3",
        aspirate_volumes=Reservoir_12col_Agilent_201256_100_BATSgroup().setColumn(
            1, media_transfer_volume_s1
        ),
        aspirate_shift=[
            0,
            0,
            4,
        ],  # larger shift needed for 12 channel reservoir #TODO remeasure 12 channel reservoir depth
    )
    soloSoft.dispense(
        position="Position4",
        dispense_volumes=Plate_96_Corning_3635_ClearUVAssay().setColumn(
            i, media_transfer_volume_s1
        ),
        dispense_shift=[0, 0, 2],
    )

# * Fill first column of culture 10 fold dilution plate with fresh lb media
soloSoft.aspirate(